Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Dent Mater ; 38(3): 549-553, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34972580

RESUMO

OBJECTIVE: Bulk-fill resin composites are a special group of restorative materials designed to reduce chair time needed to insert a direct composite restoration. However, other factors determine the clinical success of a restorative material. Clinically the major reasons for failure of direct restorations are secondary caries and fracture of the restoration or the tooth itself. In the long-term composite resin restorations in posterior teeth may be prone to wear. As bulk-fill materials have their own composition that will determine their mechanical properties, the wear resistance may be affected as well. The aim of this in vitro study was to evaluate the wear of bulk-fill composites in comparison with a conventional hybrid composite. The null hypothesis was that there are no differences between the four bulk-fill materials and one traditional highly filled nanohybrid composite for posterior use when subjected to a two-body wear rate test and hardness measurement. METHODS: Four bulk-fill composites SDR Smart Dentin Replacement (SDR), X-tra base (XBA), FiltekBulk Fill (FUP), Dual-Curing Bulk Composite (FBFL) and conventional nanohybrid resin composite Grandio (GDO) subjected to a two-body wear test against a stainless steel (SS) antagonist wheel. Scanning Electron Microscopy analysis was performed to detect the surface alterations. Microhardness of all samples was tested (n = 5) with a Vickers diamond indenter (5 indentations in each specimen). One-way ANOVA and Tukey's post hoc test (P < 0.01) were used to analyze differences in wear values. The hardness data were submitted to one-way ANOVA test, followed by the Tukey post hoc test (α = 0.05). T-test was applied to compare wear rate in time interval between one day and one month. RESULTS: The highest wear rate values were recorded for SDR and the lowest wear rate values were for GDO. Hardness was the highest for GDO and the lowest for FBFL. SIGNIFICANCE: The bulk-fill composites have a higher wear rate and lower hardness than the conventional nanohybrid composite, making them less suitable for stress-bearing restorations.


Assuntos
Resinas Compostas , Materiais Dentários , Dureza , Teste de Materiais
2.
J Oral Rehabil ; 48(10): 1129-1134, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34320246

RESUMO

BACKGROUND: Little is known about the effect of the type of splint material, heat-cured PMMA (HC) or chemical-cured PMMA (CC) on the wear of opposing tooth surfaces. OBJECTIVE: The aim of this in vitro study was to evaluate two-body wear of dentin, enamel, glass-ceramic or one of four resin composites when opposing splint materials, namely ProBase HC and CC. METHODS: The two-body wear of bovine dentine, bovine enamel, glass-ceramic IPS e.max CAD (EMAX) and four composites (Filtek Z250 [Z250], Clearfil AP-X [AP-X], Clearfil Majesty Posterior [CMP], Filtek Supreme XTE [FSE]) opposing three antagonists (HC and CC and stainless steel as control) were evaluated in the ACTA wear machine. In addition, all the surfaces were evaluated with scanning electron microscopy. RESULTS: The highest average wear was observed in the case of dentin. The lowest average wear was found EMAX. In every case-except for EMAX-the wear rate was higher with HC than with CC (all differences being statistically significant). CONCLUSIONS: The level of wear of enamel, dentin and various resin composites was higher in contact with HC than in CC, the wear of dentin being the highest. In the case of a patient with no or little tooth wear or whose teeth are restored with composite material or glass-ceramic, the splint HC might be preferred because of its better durability. However, when the splint is in contact with opposing dentin preservation of the dentin, CC might be the best choice.


Assuntos
Desgaste de Restauração Dentária , Desgaste dos Dentes , Animais , Bovinos , Resinas Compostas , Esmalte Dentário , Humanos , Teste de Materiais , Placas Oclusais , Propriedades de Superfície , Desgaste dos Dentes/terapia
3.
Front Neurol ; 10: 170, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30890999

RESUMO

Objectives: The aim is to describe the process of translating the smartphone application BruxApp into Polish within the context of an ongoing multicenter project on awake bruxism (AB) epidemiology. Material and Methods: An ongoing cooperation involving 11 universities is based on the adoption of the smartphone-based EMA protocol to collect real time report of AB behaviors in the natural environment. The English version of BruxApp is adopted as a template for the multi-language translation, according to a step-by-step procedure led by mother-tongue experts in the field. A dedicated web platform for translation (viz., POEditor) is used. The process of translation into Polish is here described as an example. Results: There are two software versions available, viz., BruxApp and BruxApp Research. For both versions, back translation from Polish to English was performed to verify the accuracy of the translation procedure. The validity of the translation has been confirmed by the perfect agreement between the original and back-translated English versions, and the Polish version of BruxApp can thus be introduced in the clinical and research setting to get deeper into the study of AB epidemiology in Poland. Conclusions: As far as clinical studies are concerned, the described strategy to record data can be very useful-patients can acknowledge their habits, monitor changes over time, and implement remedial measures. In the field of research, BruxApp makes it possible to collect and store a huge amount of data about the epidemiology of different forms of awake bruxism, both at the individual level and at the population level.

4.
Eur J Oral Sci ; 127(2): 156-161, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30609131

RESUMO

Little is known about the wear rate of enamel and dentin opposing resin composite following restoration of the occlusal surface in patients with tooth wear. Hence, the aim of this in vitro study was to evaluate the wear of enamel and dentin surfaces when opposing each of three resin composites in a two-body and three-body wear test. The two-body and three-body wear of dentin, enamel, and three resin composites (Clearfil AP-X, Filtek Z250, and Filtek Supreme) opposing four antagonists (stainless steel and three resin composites) were evaluated using the ACTA wear machine. In addition, all the surfaces were evaluated with scanning electron microscopy. The results showed the lowest wear rate in enamel and the highest in dentine, with the composite showing intermediate wear rates. The three-body wear results were not affected by the antagonist and showed pure wear caused by the abrasive food medium. The in vitro enamel/composite wear ratio was 2.5. The results show that tooth wear accelerates as soon as enamel disappears and dentin is exposed to composite resin. Therefore, it is important to protect dentin with a restorative material.


Assuntos
Resinas Compostas/química , Materiais Dentários/química , Desgaste de Restauração Dentária/estatística & dados numéricos , Teste de Materiais/métodos , Dureza , Humanos , Técnicas In Vitro , Metacrilatos/química , Propriedades de Superfície
5.
Cranio ; 36(5): 304-310, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28792365

RESUMO

OBJECTIVE: To assess the frequency and age distribution of Axis I and Axis II diagnoses among Polish patients with temporomandibular disorders (TMD). METHOD: One hundred sixty-three (n = 163) consecutive adult patients seeking TMD treatment were assessed based on the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) guidelines. Descriptive statistics on the frequency of diagnoses and mean age of the diagnostic groups was performed. RESULT: Frequency of muscle disorders, disc displacements, and other joint disorders was 56.9, 48.9, and 31%, respectively. Disc displacement was the most common diagnosis in younger patients. Severe somatization and depression were shown in 11.9 and 15.8% of patients, respectively. Only 10.5% of the patients showed severe pain-related impairment. Females tended to have higher psychosocial scores than males. DISCUSSION: The frequency of Axis I TMD diagnoses in Polish patients is similar to other populations, whereas Axis II findings slightly differ from previous reports from other countries.


Assuntos
Dor Facial/etiologia , Transtornos da Articulação Temporomandibular/epidemiologia , Adulto , Distribuição por Idade , Feminino , Humanos , Masculino , Polônia/epidemiologia , Índice de Gravidade de Doença , Fatores Sexuais , Transtornos da Articulação Temporomandibular/complicações , Transtornos da Articulação Temporomandibular/diagnóstico
6.
J Prosthodont ; 26(4): 284-288, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26646470

RESUMO

PURPOSE: The prevalence of temporomandibular disorders (TMD) in the general Polish population has not yet been thoroughly investigated. The aim of this study was to determine how frequently Polish young adults demonstrated the signs and symptoms of TMD, and how often they were aware of these. MATERIALS AND METHODS: The study involved 260 volunteers of approximately 18 years of age (and with an F:M ratio of 2.8), who had completed the Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) questionnaire in its internationally accepted Polish version. The volunteers were students from three randomly selected high schools in Kraków, Poland. Following the clinical examinations, all participants received none or one or more of the RDC/TMD axis I diagnoses on one or both sides: muscle disorders (group I), disk displacements (group II), arthralgia, osteoarthritis, and osteoarthrosis (group III). Classification on RDC/TMD axis II involved pain-related impairment (Graded Chronic Pain Severity, from 0: no TMD pain in the prior 6 months, to IV: high disability-severely limiting), depression, and somatization levels (normal, moderate, severe). RESULTS: On the RDC/TMD axis I, 69 (26.5%) of the participants received one or more of the possible diagnoses. Awareness of TMD was present in 20 (7.7%) people from that group, in the form of self-complaints. The difference between females and males was statistically significant (p  = 0.0013). On the RDC/TMD axis II assessment, a diagnosis of pain, depression, or somatization was given in 38 (14.6%) cases from that group. CONCLUSION: Muscle disorders were most frequently diagnosed in the group of Polish young adults, and the prevalence of the disease did not differ across similar groups of young people.


Assuntos
Dor Facial/epidemiologia , Transtornos da Articulação Temporomandibular/epidemiologia , Adolescente , Avaliação da Deficiência , Dor Facial/etiologia , Feminino , Humanos , Masculino , Medição da Dor , Polônia/epidemiologia , Prevalência , Inquéritos e Questionários , Transtornos da Articulação Temporomandibular/diagnóstico , Adulto Jovem
7.
Dent Mater ; 31(2): 134-40, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25498520

RESUMO

OBJECTIVE: Nowadays direct and indirect resin composites are frequently applied to build up the occlusion when extensive tooth wear took place. To achieve long-lasting restorations it is essential to obtain knowledge about their interactions due to occlusal contacts. Therefore, the two- and three-body wear between frequently used direct and indirect resin composites was investigated. MATERIALS AND METHODS: The two- and three-body wear of three direct resin composites and three indirect resin composites, with Clearfil AP-X, Filtek Z250, and Filtek Supreme XT as antagonists, were measured, using the ACTA wear device. The wear rates were determined and the surfaces were evaluated with SEM. RESULTS: The most remarkable outcome was that the two-body wear rate of the different composites opposing the Z250 wheel were significantly higher. Furthermore, it was shown that the three-body wear rate was independent on the antagonist and in general higher than the two-body wear rate. CONCLUSIONS: To reduce abrasion of the opposing resin composite surface the resin composite fillers should consist of a softer glass, e.g. barium glass or in case of a harder filler the size should be reduced to nano-size.


Assuntos
Resinas Compostas/química , Desgaste de Restauração Dentária , Metacrilatos/química , Dureza , Técnicas In Vitro , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA