Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 10(4): e0122409, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25879570

RESUMO

PURPOSE: Ahmed glaucoma valve (AGV) implant is an aqueous shunt device used to control intraocular pressure in glaucoma. Implant failure results from impervious encapsulation of the shunt plate causing increased hydraulic resistance and raised intraocular pressure. We hypothesized that deregulation of fibrosis pathway contributes to capsular resistance. We tested this by studying fibrosis related gene expression in failed AGV implants. METHODS: Differential gene expression was examined in failed AGV capsules and compared to normal control tenon. Following total RNA extraction, 84 key genes in fibrosis pathway were examined by real-time PCR using RT2 Profiler PCR Array. Relative gene expression was calculated using ΔΔCt method. Gene specific TaqMan assays were used to validate select genes with ≥2 fold differential expression in the array expression profile. RESULTS: We observed differential expression in several genes in the fibrosis pathway. Almost half (39/84) of examined genes showed ≥2 fold differential expression in majority of capsules examined on the array. TaqMan assays for select genes including CCN2 (CTGF), THBS1, SERPINE1, THBS2, COL3A1, MMP3, and IL1A in an increased validation sample set showed significant changes in expression (p value from <0.001 to 0.022) at a high frequency in concurrence with our array results. CONCLUSIONS: Pathway-focused analyses identified candidate genes with altered expression providing molecular evidence for deregulation of the fibrosis pathway in AGV failure.


Assuntos
Fibrose/genética , Expressão Gênica , Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reação em Cadeia da Polimerase em Tempo Real , Adulto Jovem
2.
Middle East Afr J Ophthalmol ; 21(2): 182-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24791112

RESUMO

In this brief communication, we present the steps used to establish a web-based congenital glaucoma registry at our institution. The contents of a case report form (CRF) were developed by a group of glaucoma subspecialists. Information Technology (IT) specialists used Lime Survey softwareTM to create an electronic CRF. A MY Structured Query Language (MySQL) server was used as a database with a virtual machine operating system. Two ophthalmologists and 2 IT specialists worked for 7 hours, and a biostatistician and a data registrar worked for 24 hours each to establish the electronic CRF. Using the CRF which was transferred to the Lime survey tool, and the MYSQL server application, data could be directly stored in spreadsheet programs that included Microsoft Excel, SPSS, and R-Language and queried in real-time. In a pilot test, clinical data from 80 patients with congenital glaucoma were entered into the registry and successful descriptive analysis and data entry validation was performed. A web-based disease registry was established in a short period of time in a cost-efficient manner using available resources and a team-based approach.


Assuntos
Glaucoma/epidemiologia , Sistema de Registros/estatística & dados numéricos , Custos e Análise de Custo , Glaucoma/congênito , Glaucoma/economia , Humanos , Internet/economia , Internet/estatística & dados numéricos , Estudos Prospectivos , Arábia Saudita/epidemiologia , Software , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA