Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Stud Health Technol Inform ; 310: 434-438, 2024 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-38269840

RESUMO

Decompressive craniectomy (DC) is a surgical procedure where a portion of the skull is removed to relieve potentially fatal brain swelling. As the swelling can take months to subside, the patient is discharged from an acute care facility to recover prior to cranioplasty (reconstruction surgery). Cranioplasty is associated with complications due to infection, seizure, haematoma and death. The interval between these surgeries is potentially a modifiable risk factor to reduce the rate of complication. We aim to allow clinicians to remotely monitor patients to facilitate an optimal pre-operative review. We have developed a platform technology encompassing a 'smart' device fitted into a skullcap to measure physiological parameters, such as changes in brain swelling, and a clinician portal that allows remote viewing of the patients' physiological data. The use of patient generated data during the transition between craniectomy and cranioplasty has the potential to significantly improve neurorehabilitation outcomes for patients.


Assuntos
Edema Encefálico , Humanos , Craniotomia , Cuidados Críticos , Alta do Paciente , Pacientes
2.
J Clin Neurosci ; 71: 251-256, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31677900

RESUMO

This report describes a novel method for occipitocervical fixation using a patient-specific, 3D-printed implant and tools. A 79-year-old female presented with progressive neck pain due to a pathologic fracture of C1. DICOM data was used to 3D-print 1:1 scale biomodels of the occipitocervical spine for pre-operative planning, patient education, and intraoperative reference. The surgeon collaborated with engineers to design and 3D-print a titanium patient-specific implant (PSI) and a stereotactic drill guide for occipitocervical screw fixation. The surgical plan specified the occipitocervical "neutral" position, screw sizes, entry points, and trajectories. The PSI was pre-contoured to match the posterior occipitocervical bony spine and reproduce the planned occipitocervical "neutral" position. Stereotactic portholes for screw fixation were integrated into the PSI. The planned "neutral" position was achieved by intraoperatively matching the occipitocervical alignment to the PSI. Screw placement under fluoroscopy was simplified using the stereotactic drill guide. There were no intraoperative or postoperative complications. At 6-month follow up, our patient reported resolution of symptoms and demonstrated satisfactory occipitocervical alignment without evidence of implant dysfunction. Our experience demonstrates that preoperative planning can be combined with biomodelling and 3D-printing to develop patient-specific tools and implants that are viable for occipitocervical fixation surgery.


Assuntos
Articulação Atlantoccipital/cirurgia , Impressão Tridimensional , Fusão Vertebral/instrumentação , Fusão Vertebral/métodos , Técnicas Estereotáxicas , Idoso , Parafusos Ósseos , Feminino , Humanos , Imageamento Tridimensional/métodos , Modelos Anatômicos , Fraturas da Coluna Vertebral/cirurgia , Cirurgia Assistida por Computador/métodos
3.
J Clin Neurosci ; 71: 43-50, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31843436

RESUMO

Pre-surgical planning using 3D-printed BioModels enables the preparation of a "patient-specific" kit to assist instrumented spinal fusion surgery. This approach has the potential to decrease operating time while also offering logistical benefits and cost savings for healthcare. We report our experience with this method in 129 consecutive patients undergoing minimally invasive transforaminal lumbar interbody fusion (MIS TLIF) over 27 months at a single centre and performed by a single surgeon. Patient imaging and surgical planning software were used to manufacture a 3D-printed patient-specific MIS TLIF kit for each patient consisting of a 1:1 scale spine BioModel, stereotactic K-wire guide, osteotomy guide, and retractors. Pre-selected pedicle screws, rods, and cages were sourced and supplied with the patient-specific kit. Additional implants were available on-shelf to address a size discrepancy between the kit implant and intraoperative measurements. Each BioModel was used pre-operatively for surgical planning, patient consent and education. The BioModel was sterilised for intraoperative reference and navigation purposes. Efficiency measures included operating time (153 ±â€¯44 min), sterile tray usage (14 ±â€¯3), fluoroscopy screening time (57.2 ±â€¯23.7 s), operative waste (19 ±â€¯8 L contaminated, 116 ±â€¯30 L uncontaminated), and median hospital stay (4 days). The pre-selected kit implants exactly matched intraoperative measurements for 597/639 pedicle screws, 249/258 rods, and 46/148 cages. Pedicle screw placement accuracy was 97.8% (625/639) on postoperative CT. Complications included one intraoperative dural tear, no blood products administered, and six reoperations. Our experience demonstrates a viable application of patient-specific 3D-printed solutions and provides a benchmark for studies of efficiency in spinal fusion surgery.


Assuntos
Imageamento Tridimensional/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Modelos Anatômicos , Medicina de Precisão/instrumentação , Fusão Vertebral/métodos , Cirurgia Assistida por Computador/métodos , Adulto , Feminino , Humanos , Vértebras Lombares/cirurgia , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Medicina de Precisão/métodos , Reoperação , Resultado do Tratamento
4.
Eur Spine J ; 28(Suppl 2): 18-24, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-29992449

RESUMO

PURPOSE: Despite the variety of "off-the-shelf" implants and instrumentation, outcomes following revision lumbosacral surgery are inconstant. Revision fusion surgery presents a unique set of patient-specific challenges that may not be adequately addressed using universal kits. This study aims to describe how patient-specific factors, surgeon requirements, and healthcare efficiencies were integrated to design and manufacture anatomically matched surgical tools and implants to complement a minimally invasive posterior approach for revision lumbar fusion surgery. METHODS: A 72-year-old woman presented with sciatica and a complex L5-S1 pseudoarthrosis 12 months after L2-S1 fixation surgery for symptomatic degenerative scoliosis. Patient computed tomography data were used to develop 1:1 scale biomodels of the bony lumbosacral spine for pre-operative planning, patient education, and intraoperative reference. The surgeon collaborated with engineers and developed a patient-specific 3D-printed titanium lumbosacral fixation implant secured by L2-L5, S2, and iliac screws. Sizes and trajectories for the S2 and iliac screws were simulated using biomodelling to develop a stereotactic 3D-printed drill guide. Self-docking 3D-printed nylon tubular retractors specific to patient tissue depth and bony anatomy at L5-S1 were developed for a minimally invasive transforaminal approach. The pre-selected screws were separately sourced, bundled with the patient-specific devices, and supplied as a kit to the hospital before surgery. RESULTS: At 6-month follow-up, the patient reported resolution of symptoms. No evidence of implant dysfunction was observed on radiography. CONCLUSION: Pre-operative planning combined with biomodelling and 3D printing is a viable process that enables surgical techniques, equipment, and implants to meet patient and surgeon-specific requirements for revision lumbar fusion surgery.


Assuntos
Vértebras Lombares/cirurgia , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Próteses e Implantes , Reoperação/instrumentação , Idoso , Feminino , Humanos , Reoperação/métodos , Escoliose/cirurgia , Fusão Vertebral/efeitos adversos , Fusão Vertebral/métodos
5.
J Clin Neurosci ; 56: 192-198, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30017594

RESUMO

Atlantoaxial transarticular screw fixation is an effective technique for arthrodesis. Surgical accuracy is critical due to the unique anatomy of the atlantoaxial region. Intraoperative aids such as computer-assisted navigation and drilling templates offer trajectory guidance but do not eliminate screw malposition. This study reports the operative and clinical performance of a novel process utilising biomodelling and 3D printing to develop patient specific solutions for posterior transarticular atlantoaxial fixation surgery. Software models and 3D printed 1:1 scale biomodels of the patient's bony atlantoaxial spine were developed from computed tomography data for surgical planning. The surgeon collaborated with a local medical device manufacturer using AnatomicsC3D to design patient specific titanium posterior atlantoaxial fixation implants using transarticular and posterior C1 arch screws. Software enabled the surgeon to specify screw trajectories, screw sizes, and simulate corrected atlantoaxial alignment allowing patient specific stereotactic drill guides and titanium posterior fixation implants to be manufactured using 3D printing. Three female patients with unilateral atlantoaxial osteoarthritis were treated using patient specific implants. Transarticular screws were placed using a percutaneous technique with fluoroscopy and neural monitoring. No screw malposition and no neural or vascular injuries were observed. Average operating and fluoroscopy times were 126.0 ±â€¯4.1 min and 36.7 ±â€¯11.5 s respectively. Blood loss was <50 ml per patient and length of stay was 4-6 days. Clinical and radiographic follow up data indicate satisfactory outcomes in all patients. This study demonstrates a safe, accurate, efficient, and relatively inexpensive process to stabilise the atlantoaxial spine using transarticular screws.


Assuntos
Articulação Atlantoaxial/cirurgia , Parafusos Ósseos , Modelagem Computacional Específica para o Paciente , Impressão Tridimensional , Fusão Vertebral/métodos , Idoso , Feminino , Humanos
6.
World Neurosurg ; 111: 1-5, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29223522

RESUMO

BACKGROUND: Advances in minimally invasive interbody fusion have greatly enhanced surgeons' capability to correct adult spinal deformity with reduced morbidity. However, the feasibility of such approaches is limited in patients with previous osteoporotic fractures as the resultant vertebral deformity renders the end plate geometry incongruous with conventional interbody implants. Current 3-dimensional (3D) printing technology offers a novel solution by fabricating custom-made implants tailored to individual anatomy. We present the results of a patient with osteoporotic lumbar fractures treated by such technology. CASE DESCRIPTION: A 74-year-old woman, with previous osteoporotic fractures at L2 and L3 resulting in concave deformity of the end plates, presented with intractable radiculopathy secondary to lateral recess and foraminal stenosis (L2-3 and L3-4). A minimally invasive lateral lumbar interbody fusion at L2-3 and L3-4 was considered favorable, but due to the associated vertebral collapse, off-the-shelf implants were not compatible with patient anatomy. In silico simulation based on preoperative computed tomography (CT) imaging was thus conducted to design customized cages to cater for the depressed recipient end plates and vertebral loss. The design was converted to implantable titanium cages through 3D additive manufacturing. At surgery, a tight fit between the implants and the targeted disk space was achieved. Postoperative CT scan confirmed excellent implant-end plate matching and restoration of lost disk space. The patient began to ambulate from postoperative day 1 and at 6-month follow-up resolution of radicular symptoms and CT evidence of interbody fusion were recorded. CONCLUSIONS: 3D-printed custom-made interbody cages can help overcome the difficulties in deformity correction secondary to osteoporotic fractures.


Assuntos
Aparelhos Ortopédicos , Fraturas por Osteoporose/terapia , Impressão Tridimensional , Idoso , Simulação por Computador , Desenho de Equipamento , Feminino , Humanos , Fraturas por Osteoporose/complicações , Fraturas por Osteoporose/diagnóstico por imagem , Radiculopatia/etiologia , Fusão Vertebral , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/cirurgia , Titânio , Tomografia Computadorizada por Raios X , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA