1.
New Solut ; : 10482911241259515, 2024 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-38847133

RESUMO

The annual occupational doses for workers at the Ghana Research Reactor-1 facility were assessed for the period 2018-2021. The dose records of monitored staff were retrieved and analysis done for dose distribution and collective effective doses. Thermoluminiscent dosimeters were used to monitor the occupational exposures. The dosimeters were evaluated for the cumulative radiation dose levels using the Harshaw 6600 TLD reader system. Annual dose of 1.52 mSv/year was the maximum acquired by an individual. An annual average effective dose range of 0.20-1.36 mSv was determined for all workers. The annual total collective effective dose was established to be in the range of 0.40-10.08 man-Sv. The 20 mSv annual limit for occupational exposure was not exceeded for monitored workers. The assessment shows that the GHARR-1 facility, in terms of radiation health effects, is a favorable environment for workers since exposures are mostly below occupational exposure limit.

2.
Radiat Prot Dosimetry ; 199(17): 2053-2060, 2023 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-37491996

RESUMO

This study aimed at assessing patient's peak skin doses (PSD) during fluoroscopy cardiac procedures and proposed a look up table to enhance patient's dose management. Perspex phantom and thermoluminescent dosemeters (TLD) were irradiated for different dose levels with X-ray equipment (Philips Azurion 7). It was found that PSD measures were higher than the kerma at the interventional reference point [K (IRP)] reported with factors 1.55, 1.75 and 2.88 for anterior posterior (AP0o), left anterior oblique (LAO45o) and right anterior oblique (RAO45o), respectively. The equations describing the correlation between the PSD measured kerma area product and cumulative air kerma were found with R-square values of 0.98 and 0.99, respectively. The statistical analysis shows a strong linear correlation between PSD and K (IRP) (P-value = 0.05). It was also found that 27% of the patients population considered in this work, received a skin dose higher than the threshold of deterministic effect of 2 Gy and a look up table with the equation of fitness were proposed to be implemented in the facility for K (IRP) higher than 500 mGy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA