Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Arch Cardiol Mex ; 90(2): 142-147, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32897265

RESUMO

In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Vasos Coronários/cirurgia , Desenho de Prótese , Stents , Animais , Ligas de Cromo/química , Doença da Artéria Coronariana/cirurgia , Cães , Fluoroscopia , Humanos , Modelos Animais , Coelhos
2.
Gac Med Mex ; 156(4): 279-285, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32831335

RESUMO

INTRODUCTION: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. OBJECTIVE: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs' antiproliferative activity and histological results. METHOD: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. RESULTS: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. CONCLUSIONS: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


INTRODUCCIÓN: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. OBJETIVO: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. MÉTODO: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. RESULTADOS: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. CONCLUSIONES: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Assuntos
Stents Farmacológicos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Animais , Modelos Animais de Doenças , Feminino , Seguimentos , Masculino , Microscopia , Desenho de Prótese , Coelhos , Espectrofotometria Infravermelho , Suínos
3.
Gac. méd. Méx ; 156(4): 276-282, Jul.-Aug. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1249911

RESUMO

Abstract Introduction: A drug-eluting coronary stent is being developed at the National Institute of Cardiology of Mexico for the treatment of ischemic heart disease. Objective: To establish the best animal model for the tests, to show the advances in the drug-eluting stent prototype, to assess two drugs’ antiproliferative activity and histological results. Method: Smooth muscle cell culture tests were performed in order to assess sirolimus and paclitaxel antiproliferative properties. The drugs were encapsulated inside the polymeric matrix of the stents. Rabbits and pigs were used as animal models. Results: Sirolimus and paclitaxel showed an inhibitory effect, which was higher for the latter. Infrared spectroscopy and light and optical microscopy showed that the drug/polymer layer properly adhered to the stent. At a four-week follow-up, both animal models showed satisfactory clinical evolution and adequate histological response, although the porcine model was shown to be more suitable for future protocols. Conclusions: Preliminary tests of the drug-eluting stent provided bases for the development of a study protocol with an adequate number of pigs and with clinical angiographic and histopathological three-month follow-up.


Resumen Introducción: En el Instituto Nacional de Cardiología de México se desarrolla una endoprótesis (stent) coronaria liberadora de fármacos para el tratamiento de la cardiopatía isquémica. Objetivo: Establecer el mejor modelo animal para las pruebas, mostrar los avances en el prototipo del stent liberador de fármacos, evaluar la actividad antiproliferativa de dos fármacos y los resultados histológicos. Método: Se realizaron cultivos de células de músculo liso para evaluar las propiedades antiproliferativas de sirolimus y paclitaxel. Los fármacos fueron encapsulados en el interior de la matriz polimérica de los stents. Se emplearon conejos y cerdos como modelos animales. Resultados: Sirolimus y paclitaxel mostraron efecto inhibitorio, mayor en el segundo. La espectroscopia infrarroja y la microscopia óptica y electrónica mostraron que la capa del polímero con el fármaco se adhería adecuadamente al stent. A las cuatro semanas de seguimiento, ambos modelos animales mostraron evolución clínica satisfactoria y adecuada respuesta histológica, si bien el modelo porcino resultó más conveniente para protocolos futuros. Conclusiones: Las pruebas preliminares del stent liberador de fármaco brindó bases para desarrollar el protocolo con un número adecuado en cerdos y con seguimiento clínico angiográfico e histopatológico a tres meses.


Assuntos
Animais , Masculino , Feminino , Coelhos , Paclitaxel/administração & dosagem , Sirolimo/administração & dosagem , Stents Farmacológicos , Desenho de Prótese , Espectrofotometria Infravermelho , Suínos , Seguimentos , Modelos Animais de Doenças , Microscopia
4.
Arch. cardiol. Méx ; 90(2): 142-147, Apr.-Jun. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1131023

RESUMO

Abstract In this paper, we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing, and mechanic trials, we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 μm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion, and safety, as well as endothelial attachment, thrombogenicity, and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion, and complete endothelial attach. Furthermore, we obtained a good post-implant balloon withdrawal, functional integrity, and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


Resumen En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 μm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Humanos , Animais , Cães , Coelhos , Desenho de Prótese , Stents , Vasos Coronários/cirurgia , Doença da Artéria Coronariana/cirurgia , Fluoroscopia , Ligas de Cromo/química , Modelos Animais
5.
Arch Cardiol Mex ; 90(2): 163-168, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32459214

RESUMO

In this paper we describe our coronary stent (INC-1) design and development, the way that we found the specific characteristics needed for our device including biophysics aspects, design, finite element testing, manufacturing and mechanic trials we submitted and animal models experiences. The stent platform was cobalt-chromium L605 (Co-Cr), with struts thickness of 80 µm, balloon expandable. We placed the coronary stent INC-1 on a rabbit and dog models so we can evaluate efficacy and security of the device in relationship to its biomechanical properties including navigation capacity, traceability, symmetric expansion and safety. As well as endothelial attachment, thrombogenicity and lack of involvement of secondary branches in these models. We succeeded in efficacy and safety of the device after fluoroscopy-guided implant proving excellent capacity of release system, traceability, fluoroscopic visualization, symmetric expansion and complete endothelial attach. Also, we obtained a good post-implant balloon withdrawal, functional integrity and no vascular complications. We observed adequate clinical evolution 3 weeks after the stent implantation.


En esta publicación se describen el diseño y el desarrollo de un stent coronario (INC-1), la forma en que se determinaron las características biofísicas deseadas, el diseño y las pruebas computacionales por elemento finito, su fabricación, así como las pruebas mecánicas a las que se sometió el prototipo y por último las primeras experiencias en modelos animales. La plataforma del stent desarrollado fue de cobalto y cromo L605 (Co-Cr), con struts de 80 µm de grosor, expandido por balón. La colocación del stent coronario INC-1 se realizó en un modelo de conejo y uno canino con el objetivo de evaluar el éxito técnico y de seguridad del stent en relación con las propiedades biomecánicas (capacidad de navegación, maniobrabilidad, expansión simétrica del stent) y de seguridad (fijación a la pared vascular y ausencia de compromiso de ramas secundarias y formación de trombos en el momento de la colocación del stent en el modelo animal). Se obtuvo éxito técnico y de seguridad del stent después del implante guiado por fluoroscopia, lo que demostró adecuada capacidad del sistema liberador, excelente maniobrabilidad, adecuada visualización fluoroscópica, expansión simétrica y fijación completa a la pared vascular, capacidad para retirar el balón desinflado después del implante, e integridad funcional y sin complicaciones vasculares. La evolución clínica fue favorable a tres semanas del seguimiento planeado.


Assuntos
Doença da Artéria Coronariana/cirurgia , Desenho de Prótese , Stents , Animais , Modelos Animais de Doenças , Cães , Fluoroscopia , Humanos , Coelhos
6.
Chest ; 158(4): 1669-1679, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32343966

RESUMO

BACKGROUND: OSA conveys worse clinical outcomes in patients with coronary artery disease. The STOP-BANG score is a simple tool that evaluates the risk of OSA and can be added to the large number of clinical variables and scores that are obtained during the management of patients with myocardial infarction (MI). Currently, machine learning (ML) is able to select and integrate numerous variables to optimize prediction tasks. RESEARCH QUESTION: Can the integration of STOP-BANG score with clinical data and scores through ML better identify patients who experienced an in-hospital cardiovascular event after acute MI? STUDY DESIGN AND METHODS: This is a prospective observational cohort study of 124 patients with acute MI of whom the STOP-BANG score classified 34 as low (27.4%), 30 as intermediate (24.2%), and 60 as high (48.4%) OSA-risk patients who were followed during hospitalization. ML implemented feature selection and integration across 47 variables (including STOP-BANG score, Killip class, GRACE score, and left ventricular ejection fraction) to identify those patients who experienced an in-hospital cardiovascular event (ie, death, ventricular arrhythmias, atrial fibrillation, recurrent angina, reinfarction, stroke, worsening heart failure, or cardiogenic shock) after definitive MI treatment. Receiver operating characteristic curves were used to compare ML performance against STOP-BANG score, Killip class, GRACE score, and left ventricular ejection fraction, independently. RESULTS: There were an increasing proportion of cardiovascular events across the low, intermediate, and high OSA risk groups (P = .005). ML selected 7 accessible variables (ie, Killip class, leukocytes, GRACE score, c reactive protein, oxygen saturation, STOP-BANG score, and N-terminal prohormone of B-type natriuretic peptide); their integration outperformed all comparators (area under the curve, 0.83 [95% CI, 0.74-0.90]; P < .01). INTERPRETATION: The integration of the STOP-BANG score into clinical evaluation (considering Killip class, GRACE score, and simple laboratory values) of subjects who were admitted for an acute MI because of ML can significantly optimize the identification of patients who will experience an in-hospital cardiovascular event.


Assuntos
Doenças Cardiovasculares/etiologia , Aprendizado de Máquina , Infarto do Miocárdio/complicações , Medição de Risco/métodos , Idoso , Doenças Cardiovasculares/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Apneia Obstrutiva do Sono/complicações
7.
Rev Invest Clin ; 72(1): 32-36, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32132738

RESUMO

BACKGROUND: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. METHODS: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. PRESENTATION OF CASES: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. CONCLUSIONS: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Assuntos
Isquemia Miocárdica/cirurgia , Desenho de Prótese , Stents , Adulto , Idoso , Seguimentos , Humanos , Masculino , México , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Projetos Piloto , Resultado do Tratamento , Ultrassonografia
8.
Rev. invest. clín ; 72(1): 32-36, Jan.-Feb. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1251832

RESUMO

ABSTRACT Background: The cost of performing a percutaneous coronary intervention is considerably high for the patient as well as for health systems, which have promoted the development of local technology to help meet the need for these devices. Methods: The INC-01 bare-metal stent was developed at the National Institute of Cardiology in Mexico City and was first implanted on porcine models with technical success in 100% of the evaluated parameters. Presentation of Cases: We present the first three cases of patients with ischemic heart disease, to whom the INC-01 bare-metal stent was implanted. Intracoronary ultrasonography was performed post-stent implantation, showing all the characteristics of implant success during evaluation and clinical follow-up. Conclusions: Angiography and intracoronary ultrasound were carried out demonstrating that the INC-01 bare-metal stent has physical, biological, and histological characteristics similar to those found in commercial metallic stents.


Assuntos
Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Desenho de Prótese , Stents , Isquemia Miocárdica/cirurgia , Projetos Piloto , Seguimentos , Ultrassonografia , Resultado do Tratamento , Isquemia Miocárdica/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , México
9.
Arch. cardiol. Méx ; 87(2): 144-150, Apr.-Jun. 2017. graf
Artigo em Inglês | LILACS | ID: biblio-887507

RESUMO

Abstract: Mexico has been positioned as the country with the highest mortality attributed to myocardial infarction among the members of the Organization for Economic Cooperation and Development. This rate responds to multiple factors, including a low rate of reperfusion therapy and the absence of a coordinated system of care. Primary angioplasty is the reperfusion method recommended by the guidelines, but requires multiple conditions that are not reached at all times. Early pharmacological reperfusion of the culprit coronary artery and early coronary angiography (pharmacoinvasive strategy) can be the solution to the logistical problem that primary angioplasty rises. Several studies have demonstrated pharmacoinvasive strategy as effective and safe as primary angioplasty ST-elevation myocardial infarction, which is postulated as the choice to follow in communities where access to PPCI is limited. The Mexico City Government together with the National Institute of Cardiology have developed a pharmaco-invasive reperfusion treatment program to ensure effective and timely reperfusion in STEMI. The model comprises a network of care at all three levels of health, including a system for early pharmacological reperfusion in primary care centers, a digital telemedicine system, an inter-hospital transport network to ensure primary angioplasty or early percutaneous coronary intervention after fibrinolysis and a training program with certification of the health care personal. This program intends to reduce morbidity and mortality associated with myocardial infarction.


Resumen: México se ha posicionado como el país con mayor mortalidad atribuible al infarto del miocardio entre los países de la Organización de Cooperación y Desarrollo Económico. Esta tasa responde a múltiples factores, incluyendo una baja tasa de reperfusión y la ausencia de un sistema único y coordinado para la atención del infarto. Aun cuando la angioplastia es el método de reperfusión recomendado, requiere un sistema coordinado con personal entrenado y recursos materiales, condiciones que no siempre pueden ser alcanzadas. La reperfusión farmacológica temprana, seguida de angiografía coronaria temprana (estrategia farmacoinvasiva) es la solución al problema logístico que representa la angioplastia primaria. Múltiples estudios han demostrado que la estrategia farmacoinvasiva es tan segura y efectiva como la angioplastia primaria en el infarto agudo del miocardio con elevación del segmento ST, y se plantea como la estrategia de elección en comunidades donde el acceso a angioplastia está limitado por factores económicos, geográficos o socioculturales. El gobierno de la Ciudad de México en conjunto con el Instituto Nacional de Cardiología ha desarrollado un programa de estrategia farmacoinvasiva para asegurar la reperfusión temprana en el infarto del miocardio. El modelo comprende una red de atención en los 3 niveles, incluyendo un sistema de reperfusión farmacológica en centros de primer contacto, transferencia de electrocardiogramas mediante telemedicina entre el primer nivel y el Instituto Nacional de Cardiología, una red de transporte interhospitalario y un programa de entrenamiento y educación continua. El objetivo de este programa es reducir la morbilidad y la mortalidad asociadas al infarto del miocardio.


Assuntos
Humanos , Reperfusão Miocárdica , Infarto do Miocárdio/cirurgia , Cardiologia/métodos , Cardiologia/tendências , Terapia Combinada , México , Infarto do Miocárdio/tratamento farmacológico
10.
Echocardiography ; 34(6): 947-948, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28370558

RESUMO

A 58-year-old male with a history of a soft tissue sarcoma in remission presented with a 2 weeks history of progressive dyspnea. Transthoracic echocardiography showed right ventricular dilation; right ventricular systolic pressure (RVSP) of 110 mm Hg, and a lobulated mass in the right ventricular outflow tract (RVOT) causing obstruction. Microbubble contrast was administered showing perfusion within the mass, which suggested malignancy. A CT pulmonary angiogram (CTPA) confirmed the presence of the mass in the RVOT without evidence of pulmonary embolism. This case demonstrates the importance of the multimodality imaging approach for the differential diagnosis of masses in the RVOT.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Ecocardiografia/métodos , Neoplasias Cardíacas/complicações , Neoplasias Cardíacas/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem , Obstrução do Fluxo Ventricular Externo/etiologia , Meios de Contraste , Diagnóstico Diferencial , Ventrículos do Coração/diagnóstico por imagem , Humanos , Aumento da Imagem/métodos , Masculino , Microbolhas , Pessoa de Meia-Idade
11.
Arch Cardiol Mex ; 87(2): 144-150, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28169119

RESUMO

Mexico has been positioned as the country with the highest mortality attributed to myocardial infarction among the members of the Organization for Economic Cooperation and Development. This rate responds to multiple factors, including a low rate of reperfusion therapy and the absence of a coordinated system of care. Primary angioplasty is the reperfusion method recommended by the guidelines, but requires multiple conditions that are not reached at all times. Early pharmacological reperfusion of the culprit coronary artery and early coronary angiography (pharmacoinvasive strategy) can be the solution to the logistical problem that primary angioplasty rises. Several studies have demonstrated pharmacoinvasive strategy as effective and safe as primary angioplasty ST-elevation myocardial infarction, which is postulated as the choice to follow in communities where access to PPCI is limited. The Mexico City Government together with the National Institute of Cardiology have developed a pharmaco-invasive reperfusion treatment program to ensure effective and timely reperfusion in STEMI. The model comprises a network of care at all three levels of health, including a system for early pharmacological reperfusion in primary care centers, a digital telemedicine system, an inter-hospital transport network to ensure primary angioplasty or early percutaneous coronary intervention after fibrinolysis and a training program with certification of the health care personal. This program intends to reduce morbidity and mortality associated with myocardial infarction.


Assuntos
Infarto do Miocárdio/cirurgia , Reperfusão Miocárdica , Cardiologia/métodos , Cardiologia/tendências , Terapia Combinada , Humanos , México , Infarto do Miocárdio/tratamento farmacológico
12.
Arthritis Rheumatol ; 67(11): 2837-44, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26245885

RESUMO

OBJECTIVE: Although blood bank-based studies have shown that rheumatoid arthritis (RA)-related autoantibodies are present before the onset of RA, information on their positive predictive value (PPV) for development of RA in healthy individuals is scarce. This study was undertaken to assess the 5-year PPV of serum IgM rheumatoid factor (IgM-RF) and anti-cyclic citrullinated peptide (anti-CCP) for the development of RA among healthy relatives of patients with RA. METHODS: Healthy relatives of RA patients were invited to participate in a cohort study. At baseline, information on participants' medical history was obtained, and serum levels of IgM-RF and anti-CCP antibodies were determined (by nephelometry and second-generation anti-CCP enzyme-linked immunosorbent assay, respectively). The subjects were followed up every 4 months via a structured interview (Community Oriented Program for Control of Rheumatic Diseases [COPCORD] questionnaire). When the COPCORD questionnaire indicated possible arthritis, subjects underwent an in-office rheumatology assessment including joint count. The study end point was defined as fulfillment of the American College of Rheumatology criteria for RA. RESULTS: Eight hundred nineteen initially healthy relatives of 252 patients with RA were included (69% female, 41% offspring, mean ± SD age 35 ± 12 years). Eleven (1.3%) were positive for both anti-CCP-2 and RF, 12 (1.5%) only for anti-CCP-2, and 16 (2%) only for RF. RA developed in 17 (2.1%) of the relatives during the 5-year followup (3,313 person-years for the seronegative group and 60.8 person-years for the anti-CCP-2-positive group). The PPV was 64% when both anti-CCP-2 and RF were positive and 58% when only anti-CCP-2 was positive. Offspring of patients with RA had an independent 3-fold increased risk of developing RA. CONCLUSION: Results of the present study indicate that the magnitude of risk for developing RA in healthy relatives of patients with RA can be estimated using simple routine laboratory tests.


Assuntos
Artrite Reumatoide/diagnóstico , Autoanticorpos/sangue , Imunoglobulina M/sangue , Peptídeos Cíclicos/imunologia , Fator Reumatoide/imunologia , Adulto , Artrite Reumatoide/sangue , Artrite Reumatoide/imunologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Inquéritos e Questionários , Adulto Jovem
13.
J Rheumatol ; 40(7): 1069-73, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23729804

RESUMO

OBJECTIVE: Data on when to stop use of biological agents in rheumatoid arthritis (RA) are scant. We assessed the length of remission and the rate of clinical relapse in patients with RA who had to discontinue treatment with tocilizumab (TCZ) because of the ending of longterm (5 yrs) open-label clinical trials. METHODS: All patients at 2 participating centers in Mexico were in remission, defined as Disease Activity Score 28 ≤ 2.6, with no swollen joints at the time of the last TCZ infusion. Patients were followed thereafter every 8 weeks for 12 months or until relapse. Relapse was defined as the presence of ≥ 1 swollen joint. Doses of methotrexate and antiinflammatory drugs were not changed during the followup period. RESULTS: Forty-five patients were analyzed, 87% were women (mean age 52 yrs, mean disease duration 14 yrs). During the 12 months of followup, 44% of patients maintained remission. Relapses occurred in 56% of patients: 14 during the first 3 months after the last TCZ administration. Retreatment using other agents achieved low disease activity or remission. CONCLUSION: Longterm clinical remission is possible in a number of patients with RA after suspension of TCZ. This effect has also been reported with other biologic agents. Additional data are required to support recommendations for discontinuing a biological agent after achieving remission.


Assuntos
Anticorpos Monoclonais Humanizados/uso terapêutico , Antirreumáticos/uso terapêutico , Artrite Reumatoide/tratamento farmacológico , Indução de Remissão , Adulto , Idoso , Quimioterapia Combinada , Feminino , Humanos , Masculino , Metotrexato/uso terapêutico , Pessoa de Meia-Idade , Recidiva , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA