Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Heart Rhythm ; 2024 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-39284399

RESUMO

BACKGROUND: Atrioventricular block (AVB) is a frequent initial presentation of cardiac sarcoidosis (CS), but dangerous ventricular arrhythmias (VA) can occur. Despite the scarcity of data, guidelines recommend implantable cardioverter-defibrillator (ICD) rather than a pacemaker implantation whenever a device is needed. OBJECTIVE: In this study, we aimed to establish predictors for sustained VA in patients with CS presenting with pacing indication because of an AVB. METHODS: We prospectively enrolled 112 patients with CS. Excluding those with VA, 82 patients remained and were divided into 2 groups: 34 individuals with AVB as initial presentation and 48 with other symptoms as first presentation (OSF). Both groups were compared for clinical characteristics, rates of VA, left ventricular assist device (LVAD) implantation, heart transplantation, and mortality. RESULTS: During follow-up, VA was detected in 50% in the AVB and 10.4% in the OSF group (P = .001). Death, LVAD implantation, and heart transplantation occurred in 11.8% in AVB group vs 10.4% in the OSF group (P = .847). Late gadolinium enhancement (LGE) was equally observed in both groups: 70% vs 70.5% (P = .966), whereas more patients in the AVB group exhibited abnormal positron emission tomography (PET) uptake: 86.2% vs 54.3% (P = .007). In multivariate analysis, AVB (hazard ratio [HR], 25.15), right ventricular (RV) LGE in cardiovascular magnetic resonance (CMR) (HR, 7.39) were predictors for VA occurrence, whereas the use of immunosuppressive therapy was associated with less VA (HR, 0.26). CONCLUSIONS: Patients with CS presenting with AVB have a high risk of sustained VA. Although immunosuppressive drugs may reduce the occurrence of VA, ICD implantation is reasonable, especially in case of RV LGE.

2.
Curr Cardiol Rep ; 26(9): 903-910, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-39023800

RESUMO

PURPOSE OF REVIEW: Cardiovascular magnetic resonance (CMR) imaging excels in providing detailed three-dimensional anatomical information together with excellent soft tissue contrast and has already become a valuable tool for diagnostic evaluation, electrophysiological procedure (EP) planning, and therapeutical stratification of atrial or ventricular rhythm disorders. CMR-based identification of ablation targets may significantly impact existing concepts of interventional electrophysiology. In order to exploit the inherent advantages of CMR imaging to the fullest, CMR-guided ablation procedures (EP-CMR) are justly considered the ultimate goal. RECENT FINDINGS: Electrophysiological cardiovascular magnetic resonance (EP-CMR) interventional procedures have more recently been introduced to the CMR armamentarium: in a single-center series of 30 patients, an EP-CMR guided ablation success of 93% has been reported, which is comparable to conventional ablation outcomes for typical atrial flutter and procedure and ablation time were also reported to be comparable. However, moving on from already established workflows for the ablation of typical atrial flutter in the interventional CMR environment to treatment of more complex ventricular arrhythmias calls for technical advances regarding development of catheters, sheaths and CMR-compatible defibrillator equipment. CMR imaging has already become an important diagnostic tool in the standard clinical assessment of cardiac arrhythmias. Previous studies have demonstrated the feasibility and safety of performing electrophysiological interventional procedures within the CMR environment and fully CMR-guided ablation of typical atrial flutter can be implemented as a routine procedure in experienced centers. Building upon established workflows, the market release of new, CMR-compatible interventional devices may finally enable targeting ventricular arrhythmias.


Assuntos
Ablação por Cateter , Imagem por Ressonância Magnética Intervencionista , Humanos , Ablação por Cateter/métodos , Imagem por Ressonância Magnética Intervencionista/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/terapia
3.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38646922

RESUMO

AIMS: High-power-short-duration (HPSD) ablation is an effective treatment for atrial fibrillation but poses risks of thermal injuries to the oesophagus and vagus nerve. This study aims to investigate incidence and predictors of thermal injuries, employing machine learning. METHODS AND RESULTS: A prospective observational study was conducted at Leipzig Heart Centre, Germany, excluding patients with multiple prior ablations. All patients received Ablation Index-guided HPSD ablation and subsequent oesophagogastroduodenoscopy. A machine learning algorithm categorized ablation points by atrial location and analysed ablation data, including Ablation Index, focusing on the posterior wall. The study is registered in clinicaltrials.gov (NCT05709756). Between February 2021 and August 2023, 238 patients were enrolled, of whom 18 (7.6%; nine oesophagus, eight vagus nerve, one both) developed thermal injuries, including eight oesophageal erythemata, two ulcers, and no fistula. Higher mean force (15.8 ± 3.9 g vs. 13.6 ± 3.9 g, P = 0.022), ablation point quantity (61.50 ± 20.45 vs. 48.16 ± 19.60, P = 0.007), and total and maximum Ablation Index (24 114 ± 8765 vs. 18 894 ± 7863, P = 0.008; 499 ± 95 vs. 473 ± 44, P = 0.04, respectively) at the posterior wall, but not oesophagus location, correlated significantly with thermal injury occurrence. Patients with thermal injuries had significantly lower distances between left atrium and oesophagus (3.0 ± 1.5 mm vs. 4.4 ± 2.1 mm, P = 0.012) and smaller atrial surface areas (24.9 ± 6.5 cm2 vs. 29.5 ± 7.5 cm2, P = 0.032). CONCLUSION: The low thermal lesion's rate (7.6%) during Ablation Index-guided HPSD ablation for atrial fibrillation is noteworthy. Machine learning based ablation data analysis identified several potential predictors of thermal injuries. The correlation between machine learning output and injury development suggests the potential for a clinical tool to enhance procedural safety.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Esôfago , Traumatismos do Nervo Vago , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Masculino , Feminino , Esôfago/lesões , Esôfago/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Pessoa de Meia-Idade , Traumatismos do Nervo Vago/etiologia , Traumatismos do Nervo Vago/epidemiologia , Incidência , Idoso , Aprendizado de Máquina , Fatores de Risco , Alemanha/epidemiologia , Queimaduras/epidemiologia , Queimaduras/etiologia , Fatores de Tempo , Resultado do Tratamento , Veias Pulmonares/cirurgia , Nervo Vago
4.
Sci Rep ; 14(1): 8974, 2024 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-38637577

RESUMO

Fully CMR-guided electrophysiological interventions (EP-CMR) have recently been introduced but data on the optimal CMR imaging protocol are scarce. This study determined the clinical utility of 3D non-selective whole heart steady-state free precession imaging using compressed SENSE (nsWHcs) for automatic segmentation of cardiac cavities as the basis for targeted catheter navigation during EP-CMR cavo-tricuspid isthmus ablation. Fourty-two consecutive patients with isthmus-dependent right atrial flutter underwent EP-CMR radiofrequency ablations. nsWHcs succeeded in all patients (nominal scan duration, 98 ± 10 s); automatic segmentation/generation of surface meshes of right-sided cavities exhibited short computation times (16 ± 3 s) with correct delineation of right atrium, right ventricle, tricuspid annulus and coronary sinus ostium in 100%, 100%, 100% and 95%, respectively. Point-by-point ablation adhered to the predefined isthmus line in 62% of patients (26/42); activation mapping confirmed complete bidirectional isthmus block (conduction time difference, 136 ± 28 ms). nsWHcs ensured automatic and reliable 3D segmentation of targeted endoluminal cavities, multiplanar reformatting and image fusion (e.g. activation time measurements) and represented the basis for precise real-time active catheter navigation during EP-CMR ablations of isthmus-dependent right atrial flutter. Hence, nsWHcs can be considered a key component in order to advance EP-CMR towards the ultimate goal of targeted substrate-based ablation procedures.


Assuntos
Flutter Atrial , Ablação por Cateter , Humanos , Flutter Atrial/diagnóstico por imagem , Flutter Atrial/cirurgia , Telas Cirúrgicas , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Arritmias Cardíacas , Resultado do Tratamento
6.
Int J Cardiovasc Imaging ; 40(2): 213-224, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37891450

RESUMO

PURPOSE: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. METHODS: MVP patients with indication for surgery due to severe mitral regurgitation (n = 19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. RESULTS: MVP patients (54 ± 10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096 ± 78ms vs. 994 ± 54ms and 33.9 ± 5.6% vs. 25.9 ± 3.1%, respectively, p < 0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE + in LV and PM was identified in 5 (26.3%) patients, while DB-LGE + was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE + in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs. 36.8%, p = 0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p = 0.029). CONCLUSIONS: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.


Assuntos
Prolapso da Valva Mitral , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/cirurgia , Músculos Papilares/patologia , Ventrículos do Coração , Meios de Contraste , Valor Preditivo dos Testes , Gadolínio , Fibrose , Imagem Cinética por Ressonância Magnética
7.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37960936

RESUMO

AIMS: Low-voltage areas (LVAs) found during left atrial (LA) electroanatomical mapping are increasingly targeted by radiofrequency catheter ablation (RFCA) on top of pulmonary vein isolation to improve arrhythmia-free survival in patients with atrial fibrillation (AF). However, pre-procedural prediction of LVAs remains challenging. The purpose of the present study was to describe the association between parameters of LA function and dimensions, respectively, derived from pre-procedural cardiovascular magnetic resonance (CMR) imaging, and the presence of LVAs on LA voltage mapping. METHODS AND RESULTS: Patients who underwent first-time RFCA for paroxysmal or persistent AF and who were in stable sinus rhythm during pre-procedural CMR imaging were included in this study. Cardiovascular magnetic resonance-derived parameters of LA function and dimensions were calculated. Low-voltage areas were defined as areas with bipolar voltage amplitudes of ≤0.5 mV on electroanatomical mapping. In total, 259 consecutive patients were included in this analysis. Low-voltage areas were found in 25 of 259 patients (9.7%). Compared with those without LVAs, patients with LVAs were significantly older, were more likely to be female, had a higher CHA2DS2-VASc score, had larger LA volumes, and had a lower LA total emptying fraction (TEF). In multivariate analysis, only LA TEF [odds ratio (OR) 0.885, 95% confidence interval (CI) 0.846-0.926, P < 0.001] and the CHA2DS2-VASc score (OR 1.507, 95% CI 1.115-2.038, P = 0.008) remained independently associated with the presence of LVAs. CONCLUSION: Left atrial TEF and the CHA2DS2-VASc score were independently associated with the presence of LVAs found during LA electroanatomical mapping. These findings may help to improve pre-procedural prediction of pro-arrhythmogenic LVAs and to improve peri-procedural patient management.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento por Ressonância Magnética , Apêndice Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/métodos
8.
Res Sq ; 2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37292932

RESUMO

Purpose: Mitral valve prolapse (MVP) is associated with left ventricle (LV) fibrosis, including the papillary muscles (PM), which is in turn linked to malignant arrhythmias. This study aims to evaluate comprehensive tissue characterization of the PM by cardiovascular magnetic resonance (CMR) imaging and its association with LV fibrosis observed by intraoperative biopsies. Methods: MVP patients with indication for surgery due to severe mitral regurgitation (n=19) underwent a preoperative CMR with characterization of the PM: dark-appearance on cine, T1 mapping, conventional bright blood (BB) and dark blood (DB) late gadolinium enhancement (LGE). CMR T1 mapping was performed on 21 healthy volunteers as controls. LV inferobasal myocardial biopsies were obtained in MVP patients and compared to CMR findings. Results: MVP patients (54±10 years old, 14 male) had a dark-appearance of the PM with higher native T1 and extracellular volume (ECV) values compared with healthy volunteers (1096±78ms vs 994±54ms and 33.9±5.6% vs 25.9±3.1%, respectively, p<0.001). Seventeen MVP patients (89.5%) had fibrosis by biopsy. BB-LGE+ in LV and PM was identified in 5 (26.3%) patients, while DB-LGE+ was observed in LV in 9 (47.4%) and in PM in 15 (78.9%) patients. DB-LGE+ in PM was the only technique that showed no difference with detection of LV fibrosis by biopsy. Posteromedial PM was more frequently affected than the anterolateral (73.7% vs 36.8%, p=0.039) and correlated with biopsy-proven LV fibrosis (Rho 0.529, p=0.029). Conclusions: CMR imaging in MVP patients referred for surgery shows a dark-appearance of the PM with higher T1 and ECV values compared with healthy volunteers. The presence of a positive DB-LGE at the posteromedial PM by CMR may serve as a better predictor of biopsy-proven LV inferobasal fibrosis than conventional CMR techniques.

9.
J Am Heart Assoc ; 12(6): e027971, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36892055

RESUMO

Cardiac sarcoidosis can mimic any cardiomyopathy in different stages. Noncaseating granulomatous inflammation can be missed, because of the nonhomogeneous distribution in the heart. The current diagnostic criteria show discrepancies and are partly nonspecific and insensitive. Besides the diagnostic pitfalls, there are controversies in the understanding of the causes, genetic and environmental background, and the natural evolution of the disease. Here, we review the current pathophysiological aspects and gaps that are relevant for future cardiac sarcoidosis diagnostics and research.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Humanos , Miocardite/diagnóstico , Cardiomiopatias/diagnóstico , Cardiomiopatias/genética , Cardiomiopatias/terapia , Sarcoidose/diagnóstico , Sarcoidose/terapia , Sarcoidose/complicações , Coração
10.
Int J Cardiol ; 376: 147-153, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36791965

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) imaging allows to combine pulmonary perfusion measurements and pulmonary venous angiography during a single-session examination with both imaging modules representing the basis for accurate diagnosis and therapeutic stratification of pulmonary vein (PV) stenosis. The present study investigated the clinical utility of dynamic pulmonary perfusion imaging integrated into a comprehensive CMR protocol for the evaluation of patients with suspected PV stenosis. METHODS: 162 patients with clinically suspected PV stenosis after catheter ablation of atrial fibrillation underwent a combined single-session CMR examination (cardiac cine imaging, dynamic pulmonary perfusion, and three-dimensional PV angiography). CMR angiography was used for visual grading of PV stenoses; dynamic pulmonary perfusion imaging was evaluated per lung lobe visually and quantitatively. RESULTS: All PV stenosis ≥90% showed a visible perfusion deficit of the corresponding lung lobe (60/60, 100%) while all PVs with luminal narrowing <50% exhibited normal pulmonary perfusion (680/680, 100%). However, every third 70-89% stenosis showed a normal pulmonary perfusion (10/31, 32%) while every fourth 50-69% PV stenosis was associated with hypoperfusion of the corresponding lung lobe (9/39, 23%). For quantitative pulmonary perfusion measurements, ROC analysis demonstrated high discriminatory power regarding PV stenosis detection with the highest AUC values for time-to-peak enhancement (cut-off value, 8.5 s). CONCLUSIONS: The combination of CMR angiography and CMR pulmonary perfusion allowed for assessment of the anatomical degree of PV stenosis and its hemodynamic impact on the pulmonary parenchymal level. Thus, the proposed comprehensive CMR protocol provided an efficient diagnostic work-up of patients with suspected PV stenosis.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Constrição Patológica , Veias Pulmonares/cirurgia , Angiografia por Ressonância Magnética/métodos , Pulmão , Perfusão , Espectroscopia de Ressonância Magnética
11.
Europace ; 25(3): 1068-1076, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36581450

RESUMO

AIMS: Left bundle branch area pacing (LBBAP) can be technically challenging and fluoroscopy-intense. Three-dimensional electroanatomical mapping (EAM) facilitates non-fluoroscopic lead navigation and electrogram mapping. We sought to prospectively evaluate the feasibility, safety, and outcomes of routine EAM-guided LBBAP in patients with structural heart disease (SHD) and advanced conduction abnormalities. METHODS AND RESULTS: Consecutive patients with SHD and conduction abnormalities who underwent an attempt at EAM-guided LBBAP were included. The feasibility, safety, procedural, and mid-term outcomes were evaluated. Electrical, echocardiographic, and clinical parameters were assessed at implantation and last follow-up. Thirty-two patients (68 ± 18 years; 19% female) were included, of which 75% had intrinsic QRS > 150 ms, 53% left bundle branch block, and 25% right bundle branch block. Primary EAM-guided LBBAP was successful in 29 patients (91%). The procedural duration was 95 (70-110) min, total fluoroscopy time 0.93 (0.40-1.73) min, and total fluoroscopy dose 35.4 (20.5-77.2) cGy cm2. Paced QRS duration (QRSd) was significantly shorter than intrinsic QRSd (121.9 ± 10.7 vs. 159.2 ± 34.4 ms; P < 0.001) and remained stable during the mean follow-up of 7.0 ± 5.9 months. The LBBAP capture threshold was 0.57 ± 0.23 V/0.4 ms at implantation and remained low during follow-up (0.58 ± 0.18 V/0.5 ± 0.2 ms; P = 0.877). Overall left ventricular ejection fraction improved significantly from 44.2 ± 14.3% at baseline to 49.4 ± 13.1% at follow-up (P = 0.009), New York Heart Association class from 2.4 ± 0.6 to 1.8 ± 0.6 (P = 0.002), respectively. No complications occurred that required intervention. CONCLUSION: Routine near-zero fluoroscopy EAM-guided LBBAP can safely be performed in patients with SHD and advanced conduction abnormalities with high success rates and favourable mid-term outcomes. Further studies are needed to investigate whether the use of EAM improves the overall outcome of conduction system pacing and to identify specific patient populations who benefit the most from EAM-guided lead implantation.


Assuntos
Marca-Passo Artificial , Humanos , Feminino , Masculino , Estimulação Cardíaca Artificial/métodos , Volume Sistólico , Eletrocardiografia/métodos , Função Ventricular Esquerda , Doença do Sistema de Condução Cardíaco , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Fascículo Atrioventricular , Resultado do Tratamento
12.
Magn Reson Med ; 89(5): 2005-2013, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36585913

RESUMO

PURPOSE: To evaluate a silent MR active catheter tracking sequence that allows conducting catheter interventions with low acoustic noise levels. METHODS: To reduce the acoustic noise associated with MR catheter tracking, we implemented a technique previously used in conventional MRI. The gradient waveforms are modified to reduce the sound pressure level (SPL) and avoid acoustic resonances of the MRI system. The efficacy of the noise reduction was assessed by software-predicted SPL and verified by measurements. Furthermore, the quality of the catheter tracking signal was assessed in a phantom experiment and during interventional cardiovascular MRI sessions targeted at isthmus-related flutter ablation. RESULTS: The maximum measured SPL in the scanner room was 104 dB(A) for real-time imaging, and 88 dB(A) and 69 dB(A) for conventional and silent tracking, respectively. The SPL measured at different positions in the MR suite using silent tracking were 65-69 dB(A), and thus within the range of a normal conversation. Equivalent signal quality and tracking accuracy were obtained using the silent variant of the catheter tracking sequence. CONCLUSION: Our results indicate that silent MR catheter tracking capabilities are identical to conventional catheter tracking. The achieved acoustic noise reduction comes at no penalty in terms of tracking quality or temporal resolution, improves comfort and safety, and can overcome the need for MR-compatible communication equipment and background noise suppression during the actual interventional procedure.


Assuntos
Imagem por Ressonância Magnética Intervencionista , Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Catéteres , Software , Imagem por Ressonância Magnética Intervencionista/métodos , Imagens de Fantasmas
13.
Eur Radiol ; 33(1): 339-347, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35984513

RESUMO

OBJECTIVES: In patients of advanced age, the feasibility of myocardial ischemia testing might be limited by age-related comorbidities and falling compliance abilities. Therefore, we aimed to test the accuracy of 3D cardiac magnetic resonance (CMR) stress perfusion in the elderly population as compared to reference standard fractional flow reserve (FFR). METHODS: Fifty-six patients at age 75 years or older (mean age 79 ± 4 years, 35 male) underwent 3D CMR perfusion imaging and invasive coronary angiography with FFR in 5 centers using the same study protocol. The diagnostic accuracy of CMR was compared to a control group of 360 patients aged below 75 years (mean age 61 ± 9 years, 262 male). The percentage of myocardial ischemic burden (MIB) relative to myocardial scar burden was further analyzed using semi-automated software. RESULTS: Sensitivity, specificity, and positive and negative predictive values of 3D perfusion CMR deemed similar for both age groups in the detection of hemodynamically relevant (FFR < 0.8) stenosis (≥ 75 years: 86%, 83%, 92%, and 75%; < 75 years: 87%, 80%, 82%, and 85%; p > 0.05 all). While MIB was larger in the elderly patients (15% ± 17% vs. 9% ± 13%), the diagnostic accuracy of 3D CMR perfusion was high in both elderly and non-elderly populations to predict pathological FFR (AUC: 0.906 and 0.866). CONCLUSIONS: 3D CMR perfusion has excellent diagnostic accuracy for the detection of hemodynamically relevant coronary stenosis, independent of patient age. KEY POINTS: • The increasing prevalence of coronary artery disease in elderly populations is accompanied with a larger ischemic burden of the myocardium as compared to younger individuals. • 3D cardiac magnetic resonance perfusion imaging predicts pathological fractional flow reserve in elderly patients aged ≥ 75 years with high diagnostic accuracy. • Ischemia testing with 3D CMR perfusion imaging has similarly high accuracy in the elderly as in younger patients and it might be particularly useful when other non-invasive techniques are limited by aging-related comorbidities and falling compliance abilities.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico , Imagem de Perfusão do Miocárdio/métodos , Índice de Gravidade de Doença , Angiografia Coronária/métodos , Valor Preditivo dos Testes , Perfusão , Espectroscopia de Ressonância Magnética
14.
J Cardiovasc Magn Reson ; 24(1): 70, 2022 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-36503589

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis represents a rare but serious complication following radiofrequency ablation of atrial fibrillation with a comprehensive diagnosis including morphological stenosis grading together with the assessment of its functional consequences being imperative within the relatively narrow window for therapeutic intervention. The present study determined the clinical utility of a combined, single-session cardiovascular magnetic resonance (CMR) imaging protocol integrating pulmonary perfusion and PV angiographic assessment for pre-procedural planning and follow-up of patients referred for interventional PV stenosis treatment. METHODS: CMR examinations (cine imaging, dynamic pulmonary perfusion, three-dimensional PV angiography) were performed in 32 consecutive patients prior to interventional treatment of PV stenosis and at 1-day and 3-months follow-up. Degree of PV stenosis was visually determined on CMR angiography; visual and quantitative analysis of pulmonary perfusion imaging was done for all five lung lobes. RESULTS: Interventional treatment of PV stenosis achieved an acute procedural success rate of 90%. Agreement between visually evaluated pulmonary perfusion imaging and the presence or absence of a ≥ 70% PV stenosis was nearly perfect (Cohen's kappa, 0.96). ROC analysis demonstrated high discriminatory power of quantitative pulmonary perfusion measurements for the detection of ≥ 70% PV stenosis (AUC for time-to-peak enhancement, 0.96; wash-in rate, 0.93; maximum enhancement, 0.90). Quantitative pulmonary perfusion analysis proved a very large treatment effect attributable to successful PV revascularization already after 1 day. CONCLUSION: Integration of CMR pulmonary perfusion imaging into the clinical work-up of patients with PV stenosis allowed for efficient peri-procedural stratification and follow-up evaluation of revascularization success.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Estenose de Veia Pulmonar , Humanos , Estenose de Veia Pulmonar/diagnóstico por imagem , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/terapia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Constrição Patológica/etiologia , Constrição Patológica/patologia , Constrição Patológica/cirurgia , Valor Preditivo dos Testes , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Pulmão/diagnóstico por imagem , Espectroscopia de Ressonância Magnética
15.
Int J Cardiol Heart Vasc ; 38: 100939, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35024429

RESUMO

INTRODUCTION: Preprocedural cardiovascular magnetic resonance (CMR) or computed tomography (CT) imaging of the left atrium/pulmonary veins is usually employed to guide catheter ablation of atrial fibrillation (AFCA). Incidental findings (IFs) are common on cardiac imaging prior to AFCA. However, previous studies have mainly focused on extracardiac IFs detected on CT scan. We aimed to assess the prevalence of relevant cardiac and extracardiac IFs on routine preprocedural CMR in a large patient cohort scheduled for first-time AFCA and report its impact on clinical decision-making and management. METHODS AND RESULTS: We included 2000 consecutive patients (62 ± 10 years; 59% male) who underwent CMR prior to first-time AFCA between April 2015 and March 2019. Among these patients 172 (8.6%) had a total of 184 major IFs. Detection of major IFs resulted in cancellation of the scheduled AFCA procedure in 88 patients (4.4%). Forty-two patients (2.1%) have never been ablated, 46 (2.3%) underwent postponed AFCA after a median time of 83 (32-213) days. The remaining 84 patients (4.2%) underwent an individualized approach to AFCA. The most common major IFs were accessory or anomalous PVs in 76 (3.8%), extracardiac abnormalities suspicious of malignancy in 29 (1.5%), and positive stress perfusion imaging in 19 (7.2% of 261 tested) patients. In 19 patients (1.0%) preprocedural CMR provided the diagnosis of a previously unknown structural cardiac disease. CONCLUSIONS: Unexpected relevant findings on routine preprocedural CMR affected clinical decision-making and management in 8.6% of patients scheduled for first-time AFCA. However, whether preprocedural CMR imaging may improve overall clinical outcome needs to be addressed in future research.

16.
Europace ; 24(1): 12-19, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34279613

RESUMO

AIMS: To establish a cardiovascular magnetic resonance (CMR)-based prediction model for complete systolic left ventricular ejection fraction (LVEF) recovery for the distinction of 'arrhythmia-induced' from 'arrhythmia-mediated' cardiomyopathy in patients with atrial tachyarrhythmias. METHODS AND RESULTS: Two hundred and fifty-three tachyarrhythmia patients referred for catheter ablation were enrolled and underwent CMR baseline imaging; patients with a reduced LVEF <50% at baseline and CMR imaging at 3-month follow-up after successful rhythm restoration constituted the final study population (n = 134). CMR at baseline consisted of standard functional cine imaging, determination of extracellular volume, and late gadolinium enhancement (LGE) imaging; follow-up CMR comprised standard functional cine imaging. Left ventricular end-diastolic volume index (LVEDVI) measurements were categorized in 'opposite', 'normal', and 'enlarged'. At follow-up, 80% (107/134) presented with complete LVEF recovery, while in 20% (27/134) persistent LVEF impairment was observed. LVEDVI and LGE were independent predictors of complete LVEF recovery with LGE adding significant incremental value on logistic regression modelling. Model-derived probabilities for complete LVEF recovery in LVEDVI categories of opposite, normal, and enlarged for LGE negativity and positivity were 94%, 85%, and 29% and 77%, 55%, and 8%, respectively. CONCLUSION: CMR-derived assessment of LVEDVI category and LGE allowed for identification of arrhythmia-induced cardiomyopathy with acceptable discriminative performance. Probabilities for complete LVEF recovery for the combination of opposite LVEDVI/LGE negativity and enlarged LVEDVI/LGE positivity were 94% and 8%, respectively. The CMR-based prediction model of complete LVEF recovery can be used to perform upfront stratification in atrial tachyarrhythmia-related LVEF impairment.


Assuntos
Meios de Contraste , Gadolínio , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Volume Sistólico , Taquicardia , Função Ventricular Esquerda
17.
JACC Case Rep ; 3(16): 1756-1759, 2021 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-34825204

RESUMO

A 25-year-old male patient with highly symptomatic, monomorphic, premature ventricular contractions presented for repeat ablation after failed endocardial ablation. Three weeks after excessive endocardial and epicardial ablation on the left ventricular summit, the patient was admitted again with tamponade following a pseudoaneurysm on the ablation site. (Level of Difficulty: Advanced.).

18.
J Cardiovasc Magn Reson ; 23(1): 87, 2021 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-34233708

RESUMO

BACKGROUND: Four-dimensional cardiovascular magnetic resonance (CMR) flow assessment (4D flow) allows to derive volumetric quantitative parameters in mitral regurgitation (MR) using retrospective valve tracking. However, prior studies have been conducted in functional MR or in patients with congenital heart disease, thus, data regarding the usefulness of 4D flow CMR in case of a valve pathology like mitral valve prolapse (MVP) are scarce. This study aimed to evaluate the clinical utility of cine-guided valve segmentation of 4D flow CMR in assessment of MR in MVP when compared to standardized routine CMR and transthoracic echocardiography (TTE). METHODS: Six healthy subjects and 54 patients (55 ± 16 years; 47 men) with MVP were studied. TTE severity grading used a multiparametric approach resulting in mild/mild-moderate (n = 12), moderate-severe (n = 12), and severe MR (n = 30). Regurgitant volume (RVol) and regurgitant fraction (RF) were also derived using standard volumetric CMR and 4D flow CMR datasets with direct measurement of regurgitant flow (4DFdirect) and indirect calculation using the formula: mitral valve forward flow - left ventricular outflow tract stroke volume (4DFindirect). RESULTS: There was moderate to strong correlation between methods (r = 0.59-0.84, p < 0.001), but TTE proximal isovelocity surface area (PISA) method showed higher RVol as compared with CMR techniques (PISA vs. CMR, mean difference of 15.8 ml [95% CI 9.9-21.6]; PISA vs. 4DFindirect, 17.2 ml [8.4-25.9]; PISA vs. 4DFdirect, 27.9 ml [19.1-36.8]; p < 0.001). Only indirect CMR methods (CMR vs. 4DFindirect) showed moderate to substantial agreement (Lin's coefficient 0.92-0.97) without significant bias (mean bias 1.05 ± 26 ml [- 50 to 52], p = 0.757). Intra- and inter-observer reliability were good to excellent for all methods (ICC 0.87-0.99), but with numerically lower coefficient of variation for indirect CMR methods (2.5 to 12%). CONCLUSIONS: In the assessment of patients with MR and MVP, cine-guided valve segmentation 4D flow CMR is feasible and comparable to standard CMR, but with lower RVol when TTE is used as reference. 4DFindirect quantification has higher intra- and inter-technique agreement than 4DFdirect quantification and might be used as an adjunctive technique for cross-checking MR quantification in MVP.


Assuntos
Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença
19.
Eur Heart J Case Rep ; 5(4): ytab094, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34124545

RESUMO

BACKGROUND: Interventricular septal perforation is an extremely rare complication of radiofrequency ablation (RFA), with an incidence of 1%. The most common mechanism is a 'steam pop', which can be described as 'mini-explosions' of gas bubbles. Data for percutaneous repair of cardiac perforations due to RFA are limited. CASE SUMMARY: A 78-year-old female patient was referred to our department for the treatment of two iatrogenic ventricular septal defects (VSDs) following radiofrequency ablation (RFA) of premature ventricular contractions. One week post-ablation, chest pain and progressive dyspnoea occurred. Transthoracic echocardiography detected a VSD, diameter 10 mm. Hence, iatrogenic, RFA-related myocardial injury was considered the most likely cause of VSD, and the patient was referred to our tertiary care centre for surgical repair. Cardiovascular magnetic resonance (CMR) imaging demonstrated border-zone oedema of the VSD only and confirmed the absence of necrotic tissue boundaries, and the patient was deemed suitable for percutaneous device closure. Laevocardiography identified an additional, smaller muscular defect that cannot be explained by analysing the Carto-Map. Both defects could be successfully closed percutaneously using two Amplatzer VSD occluder devices. DISCUSSION: In conclusion, this case demonstrates a successful percutaneous closure of a VSD resulting from RFA using an Amplatzer septal occluder device. CMR might improve tissue characterization of the VSD borders and support the decision if to opt for interventional or surgical closure.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA