RESUMO
BACKGROUND: Myocardial scar correlates with clinical outcomes. Traditionally, late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is used to detect and quantify scar. In this prospective study using LGE CMR as reference, the authors hypothesized that nonlinear ultrasound imaging, namely, power modulation, can detect and quantify myocardial scar in selected patients with previous myocardial infarction. In addition, given the different histopathology between ischemic and nonischemic scar, a further aim was to test the diagnostic performance of this echocardiographic technique in unselected consecutive individuals with ischemic and nonischemic LGE or no LGE on CMR. METHODS: Seventy-one patients with previous myocardial infarction underwent power modulation echocardiography following CMR imaging (group A). Subsequently, 101 consecutive patients with or without LGE on CMR, including individuals with nonischemic LGE, were scanned using power modulation echocardiography (group B). RESULTS: In group A, echocardiography detected myocardial scar in all 71 patients, with good scar volume agreement with CMR (bias = -1.9 cm3; limits of agreement [LOA], -8.0 to 4.2 cm3). On a per-segment basis, sensitivity was 82%, specificity 97%, and accuracy 92%. Sensitivity was higher in the inferior and posterior segments and lower in the anterior and lateral walls. In group B, on a per-subject basis, the sensitivity of echocardiography was 62% (91% for ischemic and 30% for nonischemic LGE), with specificity and accuracy of 89% and 72%, respectively. The bias for scar volume between modalities was 5.9 cm3, with LOA of 34.6 to 22.9 cm3 (bias = -1.9 cm3 [LOA, -11.4 to 7.6 cm3] for ischemic LGE, and bias = 18.9 cm3 [LOA, -67.4 to 29.7.6 cm3] for nonischemic LGE). CONCLUSIONS: Power modulation echocardiography can detect myocardial scar in both selected and unselected individuals with previous myocardial infarction and has good agreement for scar volume quantification with CMR. In an unselected cohort with nonischemic LGE, sensitivity is low.
Assuntos
Cicatriz , Infarto do Miocárdio , Humanos , Cicatriz/diagnóstico por imagem , Gadolínio , Meios de Contraste/farmacologia , Estudos Prospectivos , Valor Preditivo dos Testes , Miocárdio/patologia , Ecocardiografia/métodos , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico , Imageamento por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodosAssuntos
Valva Aórtica/diagnóstico por imagem , Doenças das Valvas Cardíacas/diagnóstico , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Ecocardiografia Transesofagiana , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de PróteseRESUMO
BACKGROUND: Myocardial scar appears brighter compared with normal myocardium on echocardiography because of differences in tissue characteristics. The aim of this study was to test how different ultrasound pulse characteristics affect the brightness contrast (i.e., contrast ratio [CR]) between tissues of different acoustic properties, as well as the accuracy of assessing tissue volume. METHODS: An experimental in vitro "scar" model was created using overheated and raw pieces of commercially available bovine muscle. Two-dimensional and three-dimensional ultrasound scanning of the model was performed using combinations of ultrasound pulse characteristics: ultrasound frequency, harmonics, pulse amplitude, steady pulse (SP) emission, power modulation (PM), and pulse inversion modalities. RESULTS: On both two-dimensional and three-dimensional imaging, the CR between the "scar" and its adjacent tissue was higher when PM was used. PM, as well as SP ultrasound imaging, provided good "scar" volume quantification. When tested on 10 "scars" of different size and shape, PM resulted in lower bias (-9.7 vs 54.2 mm3) and narrower limits of agreement (-168.6 to 149.2 mm3 vs -296.0 to 404.4 mm3, P = .03). The interobserver variability for "scar" volume was better with PM (intraclass correlation coefficient = 0.901 vs 0.815). Two-dimensional and three-dimensional echocardiography with PM and SP was performed on 15 individuals with myocardial scar secondary to infarction. The CR was higher on PM imaging. Using cardiac magnetic resonance as a reference, quantification of myocardial scar volume showed better agreement when PM was used (bias, -645 mm3; limits of agreement, -3,158 to 1,868 mm3) as opposed to SP (bias, -1,138 mm3; limits of agreement, -5,510 to 3,233 mm3). CONCLUSIONS: The PM modality increased the CR between tissues with different acoustic properties in an experimental in vitro "scar" model while allowing accurate quantification of "scar" volume. By applying the in vitro findings to humans, PM resulted in higher CR between scarred and healthy myocardium, providing better scar volume quantification than SP compared with cardiac magnetic resonance.
Assuntos
Cicatriz , Ecocardiografia Tridimensional , Animais , Bovinos , Cicatriz/diagnóstico por imagem , Meios de Contraste , Coração , Humanos , Imageamento por Ressonância Magnética , Miocárdio/patologiaRESUMO
AIM: To investigate the prevalence and prognostic impact of right heart failure and right ventricular-arterial uncoupling in Corona Virus Infectious Disease 2019 (COVID-19) complicated by an Acute Respiratory Distress Syndrome (ARDS). METHODS: Ninety-four consecutive patients (mean age 64 years) admitted for acute respiratory failure on COVID-19 were enrolled. Coupling of right ventricular function to the pulmonary circulation was evaluated by a comprehensive trans-thoracic echocardiography with focus on the tricuspid annular plane systolic excursion (TAPSE) to systolic pulmonary artery pressure (PASP) ratio RESULTS: The majority of patients needed ventilatory support, which was noninvasive in 22 and invasive in 37. There were 25 deaths, all in the invasively ventilated patients. Survivors were younger (62 ± 13 vs. 68 ± 12 years, p = 0.033), less often overweight or usual smokers, had lower NT-proBNP and interleukin-6, and higher arterial partial pressure of oxygen (PaO2)/fraction of inspired O2 (FIO2) ratio (270 ± 104 vs. 117 ± 57 mmHg, p < 0.001). In the non-survivors, PASP was increased (42 ± 12 vs. 30 ± 7 mmHg, p < 0.001), while TAPSE was decreased (19 ± 4 vs. 25 ± 4 mm, p < 0.001). Accordingly, the TAPSE/PASP ratio was lower than in the survivors (0.51 ± 0.22 vs. 0.89 ± 0.29 mm/mmHg, p < 0.001). At univariate/multivariable analysis, the TAPSE/PASP (HR: 0.026; 95%CI 0.01-0.579; p: 0.019) and PaO2/FIO2 (HR: 0.988; 95%CI 0.988-0.998; p: 0.018) ratios were the only independent predictors of mortality, with ROC-determined cutoff values of 159 mmHg and 0.635 mm/mmHg, respectively. CONCLUSIONS: COVID-19 ARDS is associated with clinically relevant uncoupling of right ventricular function from the pulmonary circulation; bedside echocardiography of TAPSE/PASP adds to the prognostic relevance of PaO2/FIO2 in ARDS on COVID-19.
Assuntos
COVID-19/complicações , COVID-19/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/virologia , Síndrome do Desconforto Respiratório/mortalidade , Síndrome do Desconforto Respiratório/virologia , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/mortalidade , Idoso , COVID-19/epidemiologia , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Prevalência , Prognóstico , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Síndrome do Desconforto Respiratório/diagnóstico por imagem , Síndrome do Desconforto Respiratório/fisiopatologia , SARS-CoV-2 , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/fisiopatologiaRESUMO
INTRODUCTION: Little is still known about the prognostic impact of incident arrhythmias in hospitalized patients with COVID-19. The aim of this study was to evaluate the incidence and predictors of sustained tachyarrhythmias in hospitalized patients with COVID-19, and their potential association with disease severity and in-hospital mortality. MATERIALS AND METHODS: This was a retrospective multicenter observation study including consecutive patients with laboratory confirmed COVID-19 admitted to emergency department of ten Italian Hospitals from 15 February to 15 March 2020. The prevalence and the type of incident sustained arrhythmias have been collected. The correlation between the most prevalent arrhythmias and both baseline characteristics and the development of ARDS and in-hospital mortality has been evaluated. RESULTS: 414 hospitalized patients with COVID-19 (66.9 ± 15.0 years, 61.1% male) were included in the present study. During a median follow-up of 28 days (IQR: 12-45), the most frequent incident sustained arrhythmia was AF (N: 71; 17.1%), of which 50 (12.1%) were new-onset and 21 (5.1%) were recurrent, followed by VT (N: 14, 3.4%) and supraventricular arrhythmias (N: 5, 1.2%). Incident AF, both new-onset and recurrent, did not affect the risk of severe adverse events including ARDS and death during hospitalization; in contrast, incident VT significantly increased the risk of in-hospital mortality (RR: 2.55; P: .003). CONCLUSIONS: AF is the more frequent incident tachyarrhythmia; however, it not seems associated to ARDS development and death. On the other hand, incident VT is a not frequent but independent predictor of in-hospital mortality among hospitalized COVID-19 patients.
Assuntos
Fibrilação Atrial/epidemiologia , COVID-19/mortalidade , Mortalidade Hospitalar , Síndrome do Desconforto Respiratório/epidemiologia , Taquicardia Supraventricular/epidemiologia , Taquicardia Ventricular/epidemiologia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/epidemiologia , COVID-19/fisiopatologia , Feminino , Hospitalização , Humanos , Incidência , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Prognóstico , Recidiva , Insuficiência Renal Crônica/epidemiologia , Síndrome do Desconforto Respiratório/fisiopatologia , Estudos Retrospectivos , Índice de Gravidade de DoençaRESUMO
BACKGROUND: Three-dimensional (3D) echocardiography is fundamental for left ventricular (LV) assessment. The aim of this study was to determine discrepancies in 3D LV endocardial tracings and suggest tracing guidance. METHODS: Forty-five 3D LV echocardiographic data sets were traced by three experienced operators, from different centers, according to predefined guidelines. The 3D meshes were compared with one another, and the endocardial areas of discrepancies were identified. A discussion and retracing protocol was used to reduce discrepancies. For each data set, an average 3D mesh was produced (reference mesh). Subsequently, four novice operators, divided into two groups, traced 20 of the data sets. Two operators followed the tracing protocol and two did not. RESULTS: The intraclass correlation coefficients among the three experienced operators for end-diastolic volume, end-systolic volume, and ejection fraction were 0.952, 0.955, and 0.932. The absolute distances between tracings were 1.11 ± 0.45 mm. The highest tracing discrepancies were at the apical cap and anterior and anterolateral walls in end-diastole and end-systole and also at the basal anteroseptum in end-systole. Agreement with the reference meshes was better for the novice operators who followed the guidance (10.9 ± 17.3 mL, 10.2 ± 14.7 mL, and -2.2 ± 4.1% for end-diastolic volume, end-systolic volume, and ejection fraction) compared with those who did not (16.3 ± 16.4 mL, 17.0 ± 16.0 mL, and -4.2 ± 4.1%, respectively). CONCLUSIONS: Comparing 3D LV tracings, the endocardial areas that are the most difficult to delineate were identified. The suggested protocol for LV tracing resulted in very good agreement among operators. The reference 3D meshes are available for online testing and ranking of LV tracing algorithms.
Assuntos
Algoritmos , Ecocardiografia Tridimensional/normas , Endocárdio/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio/complicações , Disfunção Ventricular Esquerda/diagnóstico , Função Ventricular Esquerda/fisiologia , Feminino , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia , Reprodutibilidade dos Testes , Volume Sistólico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologiaRESUMO
BACKGROUND: Current hypertension management guidelines do not recommend drug treatment in subjects with blood pressure (BP) in the high-normal range due to the risk of side effects of the currently available antihypertensive agents that overcomes the possible benefit. Nutraceuticals are free from relevant side effects and could be a valuable strategy for the treatment of these patients. AIM: The objective of this study was to compare the efficacy of two nutraceutical compositions given by the combination of policosanol, red yeast rice extract, berberine, folic acid and coenzyme Q(10) with or without Orthosiphon stamineus in lowering the BP and lipid profile. METHODS: Thirty patients with grade 1 essential hypertension and low cardiovascular risk were analysed. At the end of a run-in period, patients were divided into two study arms and assigned to receive the nutraceutical combination with and without Orthosiphon stamineus. All participants underwent 24-hour ambulatory BP monitoring at the end of the run-in period and of the 4-week treatment with each of the two different nutraceutical combinations. RESULTS: In patients treated with Orthosiphon stamineus a significant reduction of mean 24-hour systolic and diastolic BP levels compared with baseline values was registered and the smoothness index calculated for systolic and diastolic BP showed a more reliable and homogeneous effect on BP over 24 hours. In contrast, nutraceutical treatment without Orthosiphon stamineus was not associated with a significant reduction of BP. CONCLUSIONS: Our results show that the addition of Orthosiphon stamineus to the combination of nutraceuticals confers an antihypertensive effect that allows a surprisingly effective 24-hour BP control in hypertensive patients.