1.
Blood Purif ; 51(2): 138-146, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34034259

RESUMO

INTRODUCTION: Medium cutoff (MCO) membranes represent an interesting innovation in the field of hemodialysis. Given the correlation between large (PM >25 kDa) middle molecules (LMM) and clinical outcomes, the possibility to broaden the spectrum of solutes removed in hemodialysis with MCO membranes introduces a new perspective for end-stage kidney disease patients. Due to low diffusion coefficients of LMM, the use of convection is required to maximize extracorporeal clearance. High convective rates are achieved with high-flux membranes in hemodiafiltration, a technique not available in the US. In case of the MCO membrane, remarkable clearances of LMM are achieved combining the permeability of the membrane with a significant amount of internal convection. The mechanism of filtration-backfiltration inside the dialyzer enables effective removal of LMM in a technique called expanded hemodialysis (HDx). Given such theoretical explanation, it is important to demonstrate the blood and ultrafiltration rheology inside the MCO dialyzer. METHOD: This study for the first time describes flow dynamic parameters and internal cross-filtration, thanks to specific radiology and nuclear imaging techniques. RESULTS: Flow dynamic analysis of the blood and dialysate compartment confirms excellent distribution of velocities and an excellent matching of blood and dialysate. Average blood flow velocity allows for wall shear rates adequate to avoid protein stagnation at the blood membrane interface and increase in blood viscosity. Cross-filtration analysis demonstrates a remarkable filtration/backfiltration flux reaching values >30 mL/min at a blood flow of 300 mL/min and zero net filtration. CONCLUSION: The MCO dialyzer Theranova 400 appears to have a design optimized to perform expanded hemodialysis (HDx).


Assuntos
Hemodiafiltração , Falência Renal Crônica , Rins Artificiais , Soluções para Diálise , Humanos , Membranas Artificiais , Diálise Renal/métodos
2.
Blood Purif ; 48(1): 18-24, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31039563

RESUMO

BACKGROUND: Recent innovations in biomaterials technology have led to the development of innovative sorbents adopted as adsorbing devices in the field of extracorporeal blood purification therapies. As removal mechanism, adsorption allows to remove specific molecules, selectively binding them to sorbent materials. In addition to the material properties, a quintessential aspect influencing device properties is blood flow distribution within the sorbent particles. OBJECTIVES: In order to adequately characterize the potential adsorbing properties for an effective blood purification therapy, an in vitro study assessing the fluid dynamics inside 3 new cartridges, HA130, HA230 and HA330 (Jafron, Zhuhai City, -China) was conducted through CT imaging technique. -Methods: The cartridges were placed in vertical position in the CT -gantry. Dye solution was circulated through the cartridges at 250 mL/min, longitudinal sections, 0.5 cm thick, were recorded for 60 s. Furthermore, an in vitro test was conducted to build pressure drop profiles. Blood was circulated at a different flow rate, 100-400 mL/min, step 50 mL/min. Pre and post cartridges pressures were acquired and pressure drop calculated. RESULTS: Sequential images demonstrated an excellent distribution of the flow inside the cartridges. Average flow velocity was 0.37 cm/s for the 3 cartridges. HA130 had a homogeneous flow profile along the entire length of the device; HA230 and HA330 showed minimal differences between central and peripheral regions. Pressure drop profiles resulted linear, increasing proportionally with blood flow rate and packing density. CONCLUSIONS: We may conclude that the structural and functional design of the studied cartridges is adequate for haemoperfusion with no channelling phenomena. This ensures maximum and optimal utilization of the sorbent contained in the devices.


Assuntos
Circulação Extracorpórea , Hemofiltração , Hidrodinâmica , Tomografia Computadorizada por Raios X , Circulação Extracorpórea/instrumentação , Circulação Extracorpórea/métodos , Hemofiltração/instrumentação , Hemofiltração/métodos , Humanos , Tomografia Computadorizada por Raios X/métodos