Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Materials (Basel) ; 17(14)2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39063817

RESUMO

This study investigates the influence of heat treatments on the corrosion behaviour of CuSn10 tin bronze, additively manufactured using Laser Powder Bed Fusion (LPBF). LPBF enables the creation of finely structured, anisotropic microstructures, whose corrosion behaviour is not yet well understood. After production, specimens were heat-treated at 320 °C, 650 °C, and in a two-stage treatment at 800 °C and 400 °C, followed by hardness and microstructure analysis. Corrosion tests were conducted using linear polarisation, salt spray, and immersion tests. The results show that heat treatments at 320 °C and 650 °C have no significant effect on the corrosion rate, while the two-stage treatment shows a slight improvement in corrosion resistance. Differences in microstructure and hardness were observed, with higher treatment temperatures leading to grain growth and tin precipitates. The formation of a passive protective layer was detected after 30 h of OCP measurement. Results from other studies on corrosion behaviour were partially reproducible. Differences could be attributed to varying chemical compositions and manufacturing parameters. These findings contribute to the understanding of the effects of heat treatments on the corrosion resistance of additively manufactured tin bronze and provide important insights for future applications in corrosive environments.

2.
Materials (Basel) ; 17(4)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38399149

RESUMO

The influence of Ti on the behavior of hot ductility was examined in four different Ti-containing micro-alloyed steels with a constant content of Nb. Thermomechanical investigations using a dilatometer were carried out to simulate the conditions during casting and cooling in the strand of a continuous caster with temperatures in the range of 650-1100 °C, strain rates of 0.01 s-1 and 0.001 s-1, and reheating rates between 60 and 180 Kmin-1. To understand the fracture mechanism, optical (LOM) and scanning electron microscopy (SEM), elemental analysis via energy dispersive X-ray spectroscopy (EDX), MatCalc "Scheil-Guilliver" calculations, and precipitation kinetics calculations were carried out for the critical conditions, showing low hot ductility between Ar3 and Ae3 temperatures and a brittle to ductile transition temperature at 900 °C. The existence of TiNb(CN), thin ferrite formation, and grain boundary sliding (GBs) due to limited dynamic recrystallization (DRX) has been documented and discussed. As a result, the reheating rate has no sufficient effect on the ductility. The existence of Nb-rich TiNb(CN) of sizes below ~1 µm triggers brittle fracture by increasing the frequency of micro-voids around grain boundaries. It can be stated that if the conditions in the hot ductility trough are avoided, the addition of Ti and high strain support minimize the risk of crack formation.

3.
J Funct Biomater ; 14(8)2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37623664

RESUMO

Biocompatible polymers such as polymethyl methacrylate (PMMA), despite fulfilling biomedical aspects, lack the mechanical strength needed for hard-tissue implant applications. This gap can be closed by using composites with metallic reinforcements, as their adaptable mechanical properties can overcome this problem. Keeping this in mind, novel Ti-mesh-reinforced PMMA composites were developed. The influence of the orientation and volume fraction of the mesh on the mechanical properties of the composites was investigated. The composites were prepared by adding Ti meshes between PMMA layers, cured by hot-pressing above the glass transition temperature of PMMA, where the interdiffusion of PMMA through the spaces in the Ti mesh provided sufficient mechanical clamping and adhesion between the layers. The increase in the volume fraction of Ti led to a tremendous improvement in the mechanical properties of the composites. A significant anisotropic behaviour was analysed depending on the direction of the mesh. Furthermore, the shaping possibilities of these composites were investigated via four-point bending tests. High shaping possibility was found for these composites when they were shaped at elevated temperature. These promising results show the potential of these materials to be used for patient-specific implant applications.

4.
Materials (Basel) ; 15(23)2022 Nov 24.
Artigo em Inglês | MEDLINE | ID: mdl-36499870

RESUMO

Research and industry are calling for additively manufactured multi-materials, as these are expected to create more efficient components, but there is a lack of information on corrosion resistance, especially since there is a risk of bimetallic corrosion with two metallic components. In this study, the corrosion behaviour of a multi-material made of 316L and CuSn10 is investigated before and after a stress relief annealing using linear sweep voltammetry. For this purpose, a compromise had to be found in the heat treatment parameters in order to be able to treat both materials together. In addition, additively manufactured and rolled samples were investigated and used as a reference. Interaction of the two materials in the multi-material could be demonstrated, but further investigations are necessary to clearly assess the behaviour. In particular, the transition region of the two materials should be investigated. In this study, a stress relief heat treatment at 400 °C caused a slight improvement in the corrosion resistance and reduced the scatter of the measurements significantly. No significant difference was measured between the additively produced and rolled samples.

5.
Materials (Basel) ; 15(11)2022 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-35683198

RESUMO

In this study, the evolution of mechanical properties, microstructure, and residual stresses during selective laser melting of CuSn10 components was studied. To provide a proper material model for the simulations, various CuSn10 parts were manufactured using selective laser melting and examined. The manufactured parts were also used to validate the developed model. Subsequently, a sequentially coupled thermal-mechanical FEM model was developed using the Ansys software package. The developed model was able to deliver the mechanical properties, residual stresses, and microstructure of the additively manufactured components. Due to introducing some simplifications to the model, a calibration factor was applied to adjust the simulation results. However, the developed model was validated and showed a good agreement with the experimental results, such as measured residual stresses using the hole drilling method, as well as mechanical properties of manufactured parts. Moreover, the developed material model was used to simulate the microstructure of manufactured CuSn10. A fine-grain microstructure with an average diameter of 19 ± 11 µm and preferred orientation in the Z-direction, which was the assembly direction, was obtained.

6.
ACS Appl Mater Interfaces ; 10(6): 5967-5977, 2018 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-29338177

RESUMO

Titanium (Ti) is the most widely used metal in biomedical applications because of its biocompatibility; however, the significant difference in the mechanical properties between Ti and the surrounding tissues results in stress shielding which is detrimental for load-bearing tissues. In the current study, to attenuate the stress shielding effect, a new processing route was developed. It aimed at growing thick poly(methyl methacrylate) (PMMA) layers grafted on Ti substrates to incorporate a polymer component on Ti implants. However, the currently available methods do not allow the development of thick polymeric layers, reducing significantly their potential uses. The proposed route consists of an alkali activation of Ti substrates followed by a surface-initiated atom transfer radical polymerization using a phosphonic acid derivative as a coupling agent and a polymerization initiator and malononitrile as a polymerization activator. The average thickness of the grown PMMA layers is approximately 1.9 µm. The Ti activation-performed in a NaOH solution-leads to a porous sodium titanate interlayer with a hierarchical structure and an open microporosity. It promotes the covalent grafting reaction because of high hydroxyl groups' content and enables establishing a further mechanical interlocking between the growing PMMA layer and the Ti substrate. As a result, the produced graduated structure possesses high Ti/PMMA adhesion strength (∼260 MPa). Moreover, the PMMA layer is (i) thicker compared to those obtained with the previously reported techniques (∼1.9 µm), (ii) stable in a simulated body fluid solution, and (iii) biocompatible. This strategy opens new opportunities toward hybrid prosthesis with adjustable mechanical properties with respect to host bone properties for personalized medicines.

7.
Materials (Basel) ; 6(11): 5118-5130, 2013 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-28788380

RESUMO

Cold drawing is widely applied in the industrial production of seamless tubes, employed for various mechanical applications. During pre-processing, deviations in tools and their adjustment lead to inhomogeneities in the geometry of the tubes and cause a gradient in residuals. In this paper a three dimensional finite element (3D-FE)-model is presented which was developed to calculate the change in wall thickness, eccentricity, ovality and residual macro-stress state of the tubes, produced by cold drawing. The model simulates the drawing process of tubes, drawn with and without a plug. For finite element modelling, the commercial software package Abaqus was used. To validate the model, neutron strain imaging measurements were performed on the strain imaging instrument SALSA at the Institute Laue Langevin (ILL, Grenoble, France) on a series of SF-copper tubes, drawn under controlled laboratory conditions, varying the drawing angle and the plug geometry. It can be stated that there is sufficient agreement between the finite element method (FEM)-calculation and the neutron stress determination.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA