Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 61
Filtrar
1.
Talanta ; 234: 122672, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34364473

RESUMO

An Enzyme Linked ImmunoMagnetic Electrochemical assay (ELIME) was developed for the detection of the hepatitis A virus (HAV). This system is based on the use of new polydopamine-modified magnetic nanobeads as solid support for the immunochemical chain, and an array of 8 screen-printed electrodes as a sensing platform. Enzymatic-by-product is quickly measured by differential pulse voltammetry. For this purpose, all analytical parameters were optimized; in particular, different blocking reagents were evaluated in order to minimize the nonspecific interaction of bioreagents. Using the ELIME assays, a quantitative determination of HAV can be achieved with a detection limit of 1·10-11 IU mL-1 and a working range between 10-10 - 5 × 10-7 IU mL-1. The cross-reactivity of the commercial monoclonal antibodies against HAV used in ELIME assays was tested for Coxsackie B4, resulting very low. The sensitivity was also investigated and compared with spectrophotometric sandwich ELISA. The average relative standard deviation (RSD) of the ELIME method was less than 5% for the assays performed on the same day, and 7% for the measurements made on different days. The proposed system was applied to the cell culture of HAV, which title was quantified by Real-Time Quantitative Reverse Transcription PCR (RT¬qPCR). To compare the results, a correlation between the units used in ELIME (IU mL-1) and those used in RT¬qPCR (genome mL-1) was established using a HAV-positive sample, resulting in 1 IU mL-1-10-4 gen mL-1 (R2 = 0.978). The ELIME tool exhibits good stability and high biological selectivity for HAV antigen detection and was successfully applied for the determination of HAV in tap water.


Assuntos
Vírus da Hepatite A , Bioensaio , Vírus da Hepatite A/genética , Reação em Cadeia da Polimerase em Tempo Real , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade
2.
Biosens Bioelectron ; 159: 112203, 2020 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-32364935

RESUMO

A novel amperometric algae-based biosensor was developed for the detection of photosynthetic herbicides in river water. The green photosynthetic algae Chlamydomonas reinhardtii was immobilized on carbon black modified screen-printed electrodes, exploiting carbon black as smart nanomaterial to monitor changes in algae oxygen evolution during the photosynthetic process. The decrease of oxygen evolution, occurring in the presence of herbicides, results in a decrease of current signals by means of amperometric measurements, in an analyte concentration dependent manner. Atrazine as case study herbicide was detected in a concentration range of 0.1 and 50 µM, with a linear range from 0.1 to 5 µM and a detection limit of 1 nM. No interference was observed in presence of 100 ppb arsenic, 20 ppb copper, 5 ppb cadmium, 10 ppb lead, 10 ppb bisphenol A, and 1 ppb paraoxon, tested as safety limits. A ~25% matrix effect and satisfactory recovery values of 107 ± 10% and 96 ± 8% were obtained in river water for 3 and 5 µM of atrazine, respectively. Stability studies were also performed obtaining a high working stability up to 10 h and repeatability with an RSD of 1.1% (n = 12), as well as a good storage stability up to 3 weeks.


Assuntos
Técnicas Biossensoriais/métodos , Herbicidas/análise , Microalgas/química , Nanopartículas , Oxigênio/análise , Fuligem/química , Atrazina/análise , Técnicas Eletroquímicas , Reprodutibilidade dos Testes , Rios/química , Poluentes Químicos da Água/análise
3.
J Hazard Mater ; 373: 483-492, 2019 07 05.
Artigo em Inglês | MEDLINE | ID: mdl-30947038

RESUMO

In this study we reported the development of a paper-based algal biosensor for the optical detection of nanoencapsulated-atrazine, a forefront nanoformulated herbicide with a high effective post-emergence herbicidal activity. In particular, the unicellular green photosynthetic algae Chlamydomonas reinhardtii was immobilised on a paper substrate soaked with an agar thin film and placed in a glass optical measurement cell, obtaining a totally environmental-friendly device. Nanoencapsulated-atrazine was detected by following the variable fluorescence (1-VJ) parameter, which decreased inversely proportional to the herbicide concentrations, in a range between 0.5 and 200 nM, indicating a linear relationship in the measured dose-response curves and a detection limit of 4 pM. Interference studies resulted in a very slight interference in presence of 2 ppm copper and 10 ppb arsenic at safety limits, as well as a slight matrix effect and a satisfactory recovery value of 96 ± 5% for 75 nM nanoencapsulated-atrazine in tap water. Stability studies were also performed obtaining a good storage stability up to 3 weeks. Results demonstrated the suitability of the proposed paper-based optical biosensor as a valid support in smart agriculture for on site, environmental friendly, cost effective and sensitive nanoencapsulated-atrazine analysis.


Assuntos
Atrazina/análise , Técnicas Biossensoriais , Chlamydomonas reinhardtii , Herbicidas/análise , Nanoestruturas , Papel
4.
Biosens Bioelectron ; 127: 150-154, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30597433

RESUMO

Polybrominated diphenyl ethers (PBDEs) are a type of flame retardants which are currently banned in EU and USA due their hazardousness for humans and mammals. However, these compounds were highly used during more than 30 years and still persist in the environment since they are resistant to degradation. Herein we present a biosensor for the detection of PBDEs using screen printed carbon electrodes (SPCEs) based on the electrochemical monitoring of water oxidation reaction (WOR) catalyzed by iridium oxide (IV) nanoparticles (IrO2 NPs). Our assay shows a limit of detection of 21.5 ppb of PBDE in distilled water. We believe that such an IrO2 NPs-based electrocatalytic sensing system can lead to a rapid, sensitive, low cost and miniaturizable device for the detection of PBDEs.


Assuntos
Técnicas Biossensoriais , Monitoramento Ambiental , Retardadores de Chama/isolamento & purificação , Éteres Difenil Halogenados/isolamento & purificação , Carbono/química , Catálise , Retardadores de Chama/efeitos adversos , Retardadores de Chama/toxicidade , Éteres Difenil Halogenados/química , Éteres Difenil Halogenados/toxicidade , Humanos , Irídio/química , Nanopartículas/química , Bifenil Polibromatos/química , Água/química
5.
Biosens Bioelectron ; 126: 640-646, 2019 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-30522085

RESUMO

Herein, we report an impedimetric DNA-based aptamer sensor for a single-step detection of B. anthracis spore simulant (B. cereus spore). Specifically, we designed a miniaturized label-free aptasensor for B. cereus spores based on a gold screen-printed electrode functionalized with B. cereus spores-binding aptamer (BAS-6R). Several parameters were optimized to fabricate the aptasensor such as the concentration of DNA aptamer solution (0.5 µM), the time (48 h), the temperature (4 °C), and the pH (7.5) for aptamer immobilization on the working electrode surface. Once the aptasensor was developed, it was tested against B. cereus spores 14579 evaluating the effect of incubation time and MgCl2 concentration. Under the optimized conditions (incubation time equal to 3 h and absence of MgCl2), B. cereus spores 14579 were detected with a linear range between 104 CFU/ml and 5 × 106 CFU/ml and a detection limit of 3 × 103 CFU/ml. Furthermore, the study of selectivity toward B. cereus 11778, B. subtilis, Legionella pneumophila, and Salmonella Typhimurium has demonstrated the capability of this sensor to detect B. cereus spores, proving the suitability of the DNA-based sensing element combined with a portable instrument for a label-free measurement on site of B. anthracis spore simulant.


Assuntos
Aptâmeros de Nucleotídeos/química , Bacillus anthracis/isolamento & purificação , Técnicas Biossensoriais , Esporos Bacterianos/isolamento & purificação , Bacillus anthracis/patogenicidade , Técnicas Eletroquímicas , Ouro/química , Humanos , Esporos Bacterianos/patogenicidade
6.
Talanta ; 189: 365-369, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30086932

RESUMO

Bioassays based on enzyme inhibition are analytical tools widely employed for inhibitor analysis. Beside the conventional analytical techniques such as chromatography and mass spectrometry, these bioassays are cost-effective, easy to use, and suitable for in situ measurement but they are often characterised by a quite narrow linear range. Herein, we report a novel graphical method based on integrated Michaelis-Menten equation, valid for all types of reversible inhibition, which provides an extended linear range. The suitability of this innovative approach was demonstrated in the case of fluoride quantification using a colorimetric bioassay based on acetylcholinesterase inhibition. The "half time reaction", estimated by the progress curve of cholinesterase inhibition, was plotted versus the fluoride inhibitor concentration, observing an extended linear range up to 5 mM, instead of 0.6 mM using initial rate measurements. The applicability of this new concept was further demonstrated in the case of catalase enzyme inhibited by cyanide. Furthermore, it was demonstrated that fixed substrate conversion at level of 10-50% allows determination of inhibitor concentration in a wide linear range with high precision and in short time of analysis. This novel theoretical and practical approach allows for the extension of the linear range without any further experiments, with several advantages including low reagent consumption, reduced waste generation and time of measurement.


Assuntos
Técnicas Biossensoriais/métodos , Inibidores da Colinesterase/análise , Inibidores Enzimáticos/análise , Acetilcolinesterase/metabolismo , Técnicas Biossensoriais/economia , Custos e Análise de Custo , Cinética
7.
Talanta ; 188: 50-57, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30029405

RESUMO

Cortisol is a steroidal hormone and an important stress marker. Free serum cortisol concentration has been identified to correlate well with free salivary cortisol. In this present work an electrochemical immunosensor was developed to determine cortisol concentration within the physiological concentration range found in human saliva. The immunosensor is based on a direct competitive enzyme linked immunoassay using a home-made cortisol-alkaline phosphatase (AP) conjugate synthesized in our laboratory with disposable graphite screen-printed electrodes (SPEs). 1-nalphtyl phosphate (1-NP) was used as an enzymatic substrate and a square wave voltammetry (SWV) for electrochemical detection. To study method suitability for use with saliva samples, calibration curves were performed both in buffer and saliva. In buffer standard samples showed a limit of detection (LOD) of 0.6 ng/ml and working range (WR) of 0.2-44.6 ng/ml with good reproducibility (RSD 10%). Saliva matrix effect was removed effectively with Salivette Cortisol collection device (polyethylene) and a calibration curve showed similar characteristics as in buffer with LOD 1.7 ng/ml and WR 0.5-55.1 ng/ml (RSD 8%) demonstrating the possibility to determine human salivary cortisol within the desired human physiological range. Spiked saliva samples were analyzed with the developed immunosensor presenting excellent 92-114% recovery. Comparison to liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method showed strong 0.90 correlation between methods indicating good accuracy of the developed immunosensor.


Assuntos
Técnicas Eletroquímicas/métodos , Ensaio de Imunoadsorção Enzimática/métodos , Hidrocortisona/análise , Saliva/química , Fosfatase Alcalina/química , Animais , Anticorpos Monoclonais/imunologia , Carbono/química , Bovinos , Eletrodos , Cabras , Humanos , Hidrocortisona/química , Hidrocortisona/imunologia , Limite de Detecção , Camundongos , Naftalenos/química , Naftóis/química , Compostos Organofosforados/química , Reprodutibilidade dos Testes
8.
Anal Chem ; 90(13): 8196-8201, 2018 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-29874046

RESUMO

The development of rapid, cost-effective, and single-step methods for the detection of small molecules is crucial for improving the quality and efficiency of many applications ranging from life science to environmental analysis. Unfortunately, current methodologies still require multiple complex, time-consuming washing and incubation steps, which limit their applicability. In this work we present a competitive DNA-based platform that makes use of both programmable DNA-switches and antibodies to detect small target molecules. The strategy exploits both the advantages of proximity-based methods and structure-switching DNA-probes. The platform is modular and versatile and it can potentially be applied for the detection of any small target molecule that can be conjugated to a nucleic acid sequence. Here the rational design of programmable DNA-switches is discussed, and the sensitive, rapid, and single-step detection of different environmentally relevant small target molecules is demonstrated.


Assuntos
Anticorpos/imunologia , Técnicas Biossensoriais/métodos , Sondas de DNA/química , Imunoensaio/métodos , Animais , Sequência de Bases , Técnicas Biossensoriais/economia , Análise Custo-Benefício , Sondas de DNA/genética , Imunoensaio/economia , Ácido Caínico/análogos & derivados , Ácido Caínico/análise , Ácido Caínico/imunologia , Limite de Detecção , Fatores de Tempo
9.
Talanta ; 179: 186-192, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29310220

RESUMO

The recent goal of sustainability in analytical chemistry has boosted the development of eco-designed analytical tools to deliver fast and cost-effective analysis with low economic and environmental impact. Due to the recent focus in sustainability, we report the use of low-cost filter paper as a sustainable material to print silver electrodes and to load reagents for a reagent-free electrochemical detection of chloride in biological samples, namely serum and sweat. The electrochemical detection of chloride ions was carried out by exploiting the reaction of the analyte (i.e. chloride) with the silver working electrode. During the oxidation wave in cyclic voltammetry the silver ions are produced, thus they react with chloride ions to form AgCl, while in the reduction wave, the following reaction occurs: AgCl + e- -->Ag + Cl-. These reactions at the electrode surface resulted in anodic/cathodic peaks directly proportional to the chloride ions in solution. Chloride ions were detected with the addition of only 10µL of the sample on the paper-based electrochemical cell, obtaining linearity up to 200mM with a detection limit equal to 1mM and relative standard deviation lower than 10%. The accuracy of the sensor was evaluated in serum and sweat samples, with percentage recoveries between 93 ± 10 and 108 ± 8%. Moreover, the results achieved with the paper-based device were positively compared with those obtained by using the gold standard method (Ion Selective Electrode) adopted in routine clinical analyses.


Assuntos
Técnicas Biossensoriais/métodos , Cloretos/análise , Técnicas Eletroquímicas/métodos , Fitas Reagentes/análise , Soro/química , Suor/química , Técnicas Biossensoriais/economia , Calibragem , Técnicas Eletroquímicas/economia , Humanos , Eletrodos Seletivos de Íons , Limite de Detecção , Oxirredução , Papel , Fitas Reagentes/economia , Prata/química
10.
Sensors (Basel) ; 17(8)2017 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-28820458

RESUMO

Abstract:Salmonella has represented the most common and primary cause of food poisoning in many countries for at least over 100 years. Its detection is still primarily based on traditional microbiological culture methods which are labor-intensive, extremely time consuming, and not suitable for testing a large number of samples. Accordingly, great efforts to develop rapid, sensitive and specific methods, easy to use, and suitable for multi-sample analysis, have been made and continue. Biosensor-based technology has all the potentialities to meet these requirements. In this paper, we review the features of the electrochemical immunosensors, genosensors, aptasensors and phagosensors developed in the last five years for Salmonella detection, focusing on the critical aspects of their application in food analysis.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Análise de Alimentos , Microbiologia de Alimentos , Doenças Transmitidas por Alimentos , Humanos , Salmonella
11.
Chem Sci ; 8(2): 914-920, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28572901

RESUMO

Here we demonstrate the rational design of a new class of DNA-based nanoswitches which are allosterically regulated by specific biological targets, antibodies and transcription factors, and are able to load and release a molecular cargo (i.e. doxorubicin) in a controlled fashion. In our first model system we rationally designed a stem-loop DNA-nanoswitch that adopts two mutually exclusive conformations: a "Load" conformation containing a doxorubicin-intercalating domain and a "Release" conformation containing a duplex portion recognized by a specific transcription-factor (here Tata Binding Protein). The binding of the transcription factor pushes this conformational equilibrium towards the "Release" state thus leading to doxorubicin release from the nanoswitch. In our second model system we designed a similar stem-loop DNA-nanoswitch for which conformational change and subsequent doxorubicin release can be triggered by a specific antibody. Our approach augments the current tool kit of smart drug release mechanisms regulated by different biological inputs.

12.
Anal Chim Acta ; 959: 15-42, 2017 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-28159104

RESUMO

Through the years, scientists have developed cutting-edge technologies to make (bio)sensors more convenient for environmental analytical purposes. Technological advancements in the fields of material science, rational design, microfluidics, and sensor printing, have radically shaped biosensor technology, which is even more evident in the continuous development of sensing systems for the monitoring of hazardous chemicals. These efforts will be crucial in solving some of the problems constraining biosensors to reach real environmental applications, such as continuous analyses in field by means of multi-analyte portable devices. This review (with 203 refs.) covers the progress between 2010 and 2015 in the field of technologies enabling biosensor applications in environmental analysis, including i) printing technology, ii) nanomaterial technology, iii) nanomotors, iv) biomimetic design, and (v) microfluidics. Next section describes futuristic cutting-edge technologies that are gaining momentum in recent years, which furnish highly innovative aspects to biosensing devices.


Assuntos
Técnicas Biossensoriais , Monitoramento Ambiental , Microfluídica , Nanoestruturas
13.
Biosens Bioelectron ; 93: 46-51, 2017 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-27839735

RESUMO

Paper-based microfluidic devices are gaining large popularity because of their uncontested advantages of simplicity, cost-effectiveness, limited necessity of laboratory infrastructure and skilled personnel. Moreover, these devices require only small volumes of reagents and samples, provide rapid analysis, and are portable and disposable. Their combination with electrochemical detection offers additional benefits of high sensitivity, selectivity, simplicity of instrumentation, portability, and low cost of the total system. Herein, we present the first example of an integrated paper-based screen-printed electrochemical biosensor device able to quantify nerve agents. The principle of this approach is based on dual electrochemical measurements, in parallel, of butyrylcholinesterase (BChE) enzyme activity towards butyrylthiocholine with and without exposure to contaminated samples. The sensitivity of this device is largely improved using a carbon black/Prussian Blue nanocomposite as a working electrode modifier. The proposed device allows an entirely reagent-free analysis. A strip of a nitrocellulose membrane, that contains the substrate, is integrated with a paper-based test area that holds a screen-printed electrode and BChE. Paraoxon, chosen as nerve agent simulant, is linearly detected down to 3µg/L. The use of extremely affordable manufacturing techniques provides a rapid, sensitive, reproducible, and inexpensive tool for in situ assessment of nerve agent contamination. This represents a powerful approach for use by non-specialists, that can be easily broadened to other (bio)systems.


Assuntos
Técnicas Biossensoriais , Substâncias para a Guerra Química/isolamento & purificação , Agentes Neurotóxicos/isolamento & purificação , Paraoxon/isolamento & purificação , Butirilcolinesterase/química , Butiriltiocolina/química , Substâncias para a Guerra Química/química , Técnicas Eletroquímicas , Humanos , Dispositivos Lab-On-A-Chip , Agentes Neurotóxicos/toxicidade , Papel , Paraoxon/química
14.
Anal Bioanal Chem ; 408(26): 7299-309, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27251198

RESUMO

We report a screen-printed electrode (SPE) modified with a dispersion of carbon black (CB) and chitosan by drop casting. A cyclic voltammetry technique towards ferricyanide, caffeic acid, hydroquinone, and thiocholine was performed and an improvement of the electrochemical response with respect to bare SPE as well as SPE modified only with chitosan was observed. The possibility to detect thiocholine at a low applied potential with high sensitivity was exploited and an acetylcholinesterase (AChE) biosensor was developed. A dispersion of CB, chitosan, and AChE was used to fabricate this biosensor in one step by drop casting. The enzymatic activity of the immobilized AChE was determined measuring the enzymatic product thiocholine at +300 mV. Owing to the capability of organophosphorus pesticides to inhibit AChE, this biosensor was used to detect these pollutants, and paraoxon was taken as model compound. The enzyme inhibition was linearly related to the concentration of paraoxon up to 0.5 µg L(-1), and a low detection limit equal to 0.05 µg L(-1) (calculated as 10% of inhibition) was achieved. This biosensor was challenged for paraoxon detection in drinking waters with satisfactory recovery values. The use of AChE embedded in a dispersion of CB and chitosan allowed an easy and fast production of a sensitive biosensor suitable for paraoxon detection in drinking waters at legal limit levels. Graphical Abstract Biosensors based on screen-printed electrodes modified with Acetylcholinesterase, Carbon Black, and Chitosan for organophosphorus pesticide detection.


Assuntos
Acetilcolinesterase/química , Técnicas Biossensoriais/instrumentação , Quitosana/química , Electrophorus , Paraoxon/análise , Fuligem/química , Poluentes Químicos da Água/análise , Animais , Técnicas Biossensoriais/métodos , Inibidores da Colinesterase/análise , Água Potável/análise , Eletrodos , Electrophorus/metabolismo , Enzimas Imobilizadas/química , Inseticidas/análise , Limite de Detecção
15.
Anal Chim Acta ; 919: 78-84, 2016 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-27086102

RESUMO

Herein we describe a novel reagentless paper-based electrochemical phosphate sensor, manufactured with a simple and inexpensive approach. By following three easy steps, consisting of wax patterning, paper chemical modification, and electrode screen-printing, the filter paper provides an effective electroanalytical platform to sense phosphate ions in standard solutions and real samples (river water). The electrochemical properties of the paper-based platform were evaluated, firstly, by using ferricyanide as a redox mediator, proving no analyte-entrapment due to the cellulose lattice. Then, the reference colorimetric method for phosphate ions, which is based on the formation of phosphomolybdic complex, was successfully adapted to a reagentless electrochemically paper-based platform. This novel and highly sustainable configuration readily allows for the determination of phosphate ions with high reproducibility and long storage stability, achieving a detection limit of 4 µM over a wide linear range up to 300 µM. This in-house approach would be able to generically develop an affordable in situ and user-friendly sensing device without the addition of any reagent, to be applied for a broad range of analytes.

16.
Talanta ; 150: 440-8, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26838428

RESUMO

In this study, we report a novel assay for the combined on site detection of aflatoxin B1 (AFB1) and ochratoxin A (OTA), through a colorimetric biosensing system for AFB1 and a fluorimetric detection for OTA, exploiting the capability of the portable fibre optic spectrometer to perform both analyses. AFB1 was detected using the acetylcholinesterase (AChE) enzyme that is inhibited by this toxin, and the degree of inhibition was quantified by the Ellman's spectrophotometric method, obtaining a detection limit of 10 µg L(-1). OTA quantification was performed by monitoring its intrinsic fluorescence in methanol, reaching a detection limit of 0.1 µg L(-1). In order to successfully apply the analytical tool in the food analysis, immunoaffinity columns were used. Clean-up and quantification of both AFB1 and OTA in millet samples was obtained by HPLC-dedicated AflaOchra-Test HPLC™ (Vicam™) and Afla-OtaCLEAN™ (LC-Tech) immunoaffinity columns, followed by absorption/fluorescence detection. Millet samples which were fortified with both OTA (50 µg kg(-1)) and AFB1 (20 µg kg(-1)), gave recovery values of 100 ± 6% for OTA, and 110 ± 10% for AFB1, using AflaOchra-Test HPLC™. Single OTA clean-up and quantification in wine samples was obtained, using an OchraTest immunoaffinity column (Vicam™), reaching a detection limit of 0.3 µg L(-1) and recovery values between 80% and 120%. These results demonstrated the possibility of employing a single clean-up and a cost-effective, and easy to use analytical system for both AFB1 and OTA detection at µg kg(-1) (ppb) level. Furthermore, in the case of positive samples, they could be analysed further, using standard chromatographic procedures, without any additional clean-up step, since the same extraction procedure of standard method is proposed in our method.


Assuntos
Aflatoxina B1/análise , Análise de Alimentos/instrumentação , Contaminação de Alimentos/análise , Ocratoxinas/análise , Dispositivos Ópticos , Artefatos , Técnicas Biossensoriais , Colorimetria , Fluorometria , Metanol/química , Milhetes/química , Fibras Ópticas , Análise Espectral , Fatores de Tempo , Vinho/análise
17.
Environ Sci Technol ; 49(13): 7934-9, 2015 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-26066782

RESUMO

An automatable flow system for the continuous and long-term monitoring of the phosphate level has been developed using an amperometric detection method based on the use of a miniaturized sensor. This method is based on the monitoring of an electroactive complex obtained by the reaction between phosphate and molybdate that is consequently reduced at the electrode surface. The use of a screen-printed electrode modified with carbon black nanoparticles (CBNPs) leads to the quantification of the complex at low potential, because CBNPs are capable of electrocatalitically enhancing the phosphomolybdate complex reduction at +125 mV versus Ag/AgCl without fouling problems. The developed system also incorporates reagents and waste storage and is connected to a portable potentiostat for rapid detection and quantification of phosphate. Main analytical parameters, such as working potential, reagent concentration, type of cell, and flow rate, were evaluated and optimized. This system was characterized by a low detection limit (6 µM). Interference studies were carried out. Good recovery percentages comprised between 89 and 131.5% were achieved in different water sources, highlighting its suitability for field measurements.


Assuntos
Análise Custo-Benefício , Nanopartículas/química , Fosfatos/análise , Impressão/economia , Impressão/métodos , Fuligem/análise , Técnicas Eletroquímicas/economia , Eletrodos , Espectrofotometria
18.
Talanta ; 141: 267-72, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-25966413

RESUMO

We report a sensor for phosphate detection based on screen-printed electrodes modified with carbon black nanoparticles. The phosphate was measured in amperometric mode via electrochemical reduction of molybdophosphate complex. Carbon black nanoparticles demonstrated the ability to quantify the molybdophosphate complex at a low applied potential. Some analytical parameters such as the working solution (sulfuric acid 0.1M), applied potential (0.125V vs Ag/AgCl), and molybdate concentration (1mM) were optimized. Using these conditions, a linear range of 0.5-100µM was observed with a detection limit of 0.1µM, calculated as three times the standard deviation of the blank divided by the slope of calibration curve. The system was challenged in drinking, river, aquarium, and waste water samples yielding satisfactory recovery values in accordance with a spectrophotometric reference method which demonstrated the suitability of the screen-printed electrode modified with carbon black nanoparticles coupled with the use of molybdate to detect phosphate in water samples.


Assuntos
Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Nanopartículas/química , Fosfatos/análise , Calibragem , Carbono/química , Desenho de Equipamento , Concentração de Íons de Hidrogênio , Limite de Detecção , Molibdênio/química , Ácidos Fosfóricos/química , Espectrofotometria/métodos , Águas Residuárias/análise , Água/análise
19.
Chem Commun (Camb) ; 51(41): 8668-71, 2015 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-25908115

RESUMO

A new microengine-based built-in-platform exploiting a surprising dual action with solution mixing and control of the reaction parameters, has been applied for accelerating chemical reactions (organophosphorous nerve agents hydrolysis) and electrochemical detection of non-hazardous by-product (p-nitrophenol) using printable sensor strip.

20.
Sensors (Basel) ; 15(2): 4353-67, 2015 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-25688587

RESUMO

In this work a novel bioassay for mustard agent detection was proposed. The bioassay is based on the capability of these compounds to inhibit the enzyme choline oxidase. The enzymatic activity, which is correlated to the mustard agents, was electrochemically monitored measuring the enzymatic product, hydrogen peroxide, by means of a screen-printed electrode modified with Prussian Blue nanoparticles. Prussian Blue nanoparticles are able to electrocatalyse the hydrogen peroxide concentration reduction at low applied potential (-50 mV vs. Ag/AgCl), thus allowing the detection of the mustard agents with no electrochemical interferences. The suitability of this novel bioassay was tested with the nitrogen mustard simulant bis(2-chloroethyl)amine and the sulfur mustard simulants 2-chloroethyl ethyl sulfide and 2-chloroethyl phenyl sulfide. The bioassay proposed in this work allowed the detection of mustard agent simulants with good sensitivity and fast response, which are excellent premises for the development of a miniaturised sensor well suited for an alarm system in case of terrorist attacks.


Assuntos
Oxirredutases do Álcool/metabolismo , Bioensaio/métodos , Ferrocianetos/química , Nanopartículas/química , Eletrodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA