RESUMO
Unfortunately, during pathological conditions resulting in chronic hemolysis cell-free hemoglobin (Hb) is released into the circulation that releases free heme, resulting in several complications. One approach to prevent these toxicities is the administration of supplemental scavenger proteins, haptoglobin (Hp) and hemopexin (Hpx). The goal of this body of work is to objectively measure the levels of vascular reactivity and inflammatory profiles after an infusion of acellular hemoglobin in animals that were given a coadministration of PEGylated human apohemoglobin (PEG-apoHb), a hemopexin (Hpx)-mimetic that can scavenge free heme from hemoglobin, together with human plasma-derived Hp that can scavenge dimerized Hb. Using intravital microscopy, Golden Syrian hamsters instrumented with a dorsal window chamber were used to evaluate the in vivo effects of four experimental groups that were then challenged with a hypovolemic injection (10% of the animal's blood volume) of human Hb (hHb, 5 g/dL). The four experimental groups consisted of: 1) lactated Ringer's solution (control), 2) PEG-apoHb only, 3) Hp only, and 4) PEG-apoHb + Hp. The microvascular hemodynamics (diameter and flow) in arterioles and venules were recorded at baseline, 20 min after treatment, and 20 min after hHb challenge. Systemic parameters (blood pressure and heart rate), blood gases (pH, Pco2, and Po2), blood parameters (Hb concentration and hematocrit), and multiorgan functionality/inflammation were also measured. Our results suggest that coadministration of PEG-apoHb + Hp as a booster before the infusion of acellular hemoglobin significantly prevented vasoconstriction in the microcirculation, significantly increased the number of functional capillaries, and significantly reduced inflammation.NEW & NOTEWORTHY Coadministration of PEGylated human apohemoglobin (PEG-apoHb)-a hemopexin (Hpx) mimetic that can scavenge free heme-and human plasma-derived haptoglobin (Hp) that can scavenge hemoglobin (Hb), reduces microcirculatory dysfunction and cardiac and kidney inflammation in a Hb-challenge model.
Assuntos
Haptoglobinas , Hemoglobinas , Hemopexina , Inflamação , Mesocricetus , Microcirculação , Polietilenoglicóis , Animais , Haptoglobinas/administração & dosagem , Haptoglobinas/farmacologia , Haptoglobinas/metabolismo , Microcirculação/efeitos dos fármacos , Hemoglobinas/metabolismo , Hemoglobinas/administração & dosagem , Inflamação/tratamento farmacológico , Hemopexina/metabolismo , Hemopexina/administração & dosagem , Masculino , Polietilenoglicóis/administração & dosagem , Polietilenoglicóis/farmacologia , Cricetinae , HumanosRESUMO
Lung transplantation is hampered by the lack of suitable donors. Previously, donors that were thought to be marginal or inadequate were discarded. However, new and exciting technology, such as ex vivo lung perfusion (EVLP), offers lung transplant providers extended assessment for marginal donor allografts. This dynamic assessment platform has led to an increase in lung transplantation and has allowed providers to use donors that were previously discarded, thus expanding the donor pool. Current perfusion techniques use cellular or acellular perfusates, and both have distinct advantages and disadvantages. Perfusion composition is critical to maintaining a homeostatic environment, providing adequate metabolic support, decreasing inflammation and cellular death, and ultimately improving organ function. Perfusion solutions must contain sufficient protein concentration to maintain appropriate oncotic pressure. However, current perfusion solutions often lead to fluid extravasation through the pulmonary endothelium, resulting in inadvertent pulmonary edema and damage. Thus, it is necessary to develop novel perfusion solutions that prevent excessive damage while maintaining proper cellular homeostasis. Here, we describe the application of a polymerized human hemoglobin (PolyhHb)-based oxygen carrier as a perfusate and the protocol in which this perfusion solution can be tested in a model of rat EVLP. The goal of this study is to provide the lung transplant community with key information in designing and developing novel perfusion solutions, as well as the proper protocols to test them in clinically relevant translational transplant models.
Assuntos
Hemoglobinas , Transplante de Pulmão , Pulmão , Perfusão , Animais , Ratos , Transplante de Pulmão/métodos , Hemoglobinas/química , Perfusão/métodos , Pulmão/metabolismo , Humanos , Oxigênio/metabolismo , Substitutos Sanguíneos/farmacologia , Substitutos Sanguíneos/química , Masculino , Soluções para Preservação de Órgãos/químicaRESUMO
The biodistribution of many therapeutics is controlled by the immune system. In addition, some molecules are cytotoxic when not encapsulated inside of larger cellular structures, such as hemoglobin (Hb) encapsulation inside of red blood cells (RBCs). To counter immune system recognition and cytotoxicity, drug delivery systems based on red blood cell membrane fragments (RBCMFs) have been proposed as a strategy for creating immunoprivileged therapeutics. However, the use of RBCMFs for drug delivery applications requires purification of RBCMFs at large scale from lysed RBCs free of their intracellular components. In this study, we were able to successfully use tangential flow filtration (TFF) to remove >99% of cell-free Hb from lysed RBCs at high concentrations (30%-40% v/v), producing RBCMFs that were 2.68 ± 0.17 µm in diameter. We were also able to characterize the RBCMFs more thoroughly than prior work, including measurement of particle zeta potential, along with individual TFF diacycle data on the cell-free Hb concentration in solution and time per diacycle, as well as concentration and size of the RBCMFs. In addition to purifying RBCMFs from lysed RBCs, we utilized a hypertonic solution to reseal purified RBCMFs encapsulating a model protein (Hb) to yield resealed Hb-encapsulated RBC ghosts (Hb-RBCGs). TFF was then compared against centrifugation as an alternative method for removing unencapsulated Hb from Hb-RBCGs, and the effects that each washing method on the resulting Hb-RBCG biophysical properties was assessed.
RESUMO
Human serum albumin (HSA) is currently used as a plasma expander (PE) to increase blood volume during hypovolemic conditions, such as blood loss. However, its effectiveness is suboptimal in septic shock and burn patients due to their enhanced endothelial permeability, resulting in HSA extravasation into the tissue space leading to edema, and deposition of toxic HSA-bound metabolites. Hence, to expand HSA's applicability toward treating patients with compromised endothelial permeability, HSA has been previously polymerized to increase its molecular size thus compartmentalizing the polymerized HSA (PolyHSA) molecules in the vascular space. Previous studies bracketed PolyHSA between 100 kDa and 0.2 µm. In this research, PolyHSA was synthesized at two cross-link densities 43:1 and 60:1 (i.e., molar ratios of glutaraldehyde to HSA) and subsequently fractionated via tangential flow filtration (TFF) into two narrower brackets: bracket A (500 kDa and 0.2 µm) and bracket B (50-500 kDa). PolyHSA within the same size bracket at different cross-link densities exhibited similar solution viscosity, zeta potential, and osmolality but differed in hydrodynamic diameter. At the same cross-link density, the PolyHSA A bracket showed higher viscosity, lowered zeta potential, and a larger hydrodynamic diameter compared with the PolyHSA B bracket while maintaining osmolality. Interestingly, PolyHSA 43:1 B, PolyHSA 60:1 A, and PolyHSA 60:1 B brackets exhibited colloid osmotic pressure similar to HSA, indicating their potential to serve as PEs.
RESUMO
INTRODUCTION: The demand for red blood cells (RBCs) is on the rise due to the increasing diagnosis of chronic diseases such as sickle cell anemia, malaria, and thalassemia. Despite many commercial attempts, there are no U.S. FDA-approved artificial RBCs for use in humans. Existing RBC substitutes have employed various strategies to transport oxygen, extend the circulation time, and reduce organ toxicity, but none have replicated the natural protective mechanisms of RBCs, which prevent hemoglobin (Hb) dimerization and heme iron oxidation. Lumbricus terrestris (earthworm) erythrocruorin (LtEc) is a naturally occurring extracellular hemoglobin (Hb) with promising attributes: large molecular diameter (30 nm), high molecular weight (3.6 MDa), low auto-oxidation rate, and limited nitric oxide-scavenging properties. These characteristics make LtEc an ideal candidate as an RBC substitute. However, LtEc has a significant drawback, its short circulatory half-life. To address this issue, we explored thiol-mediated surface PEGylation of LtEc (PEG-LtEc) at varying polyethylene glycol (PEG) surface coverages. Increasing PEG surface coverage beyond 40% destabilizes LtEc into smaller subunits that are 1/12th the size of LtEc. Therefore, we evaluated two PEG surface coverage options: PEG-LtEc-0.2 (20% PEGylation) and PEG-LtEc-1.0 (100% PEGylation). METHODS: We conducted experiments using golden Syrian hamsters with dorsal window chambers and catheters to assess the efficacy of these solutions. We measured microvascular parameters, organ function, cerebral blood flow, circulation time, mean arterial pressure, heart rate, and blood gases and performed histology to screen for toxicity. CONCLUSION: Our findings indicate that both PEG-LtEc molecules offer significant benefits in restoring microvascular parameters, organ function, cerebral blood flow, and circulation time compared to LtEc alone. Notably, PEG-LtEc-1.0 showed superior microvascular perfusion, although it exhibited a higher rate of auto-oxidation compared to PEG-LtEc-0.2. These results underscore the advantages of PEGylation in terms of tissue perfusion and organ health while highlighting its limitations.
Assuntos
Eritrócitos , Hemoglobinas , Oligoquetos , Animais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Hemoglobinas/química , Hemoglobinas/metabolismo , Hemoglobinas/farmacologia , Teste de Materiais , Microcirculação , Oligoquetos/química , Oxirredução , Tamanho da Partícula , Polietilenoglicóis/química , Polietilenoglicóis/farmacologia , Eritrócitos/metabolismo , MesocricetusRESUMO
The widespread adoption of high-calorie, high-fat, high-sucrose diets (HFHSD) has become a global health concern, particularly due to their association with cardiovascular diseases and metabolic disorders. These comorbidities increase susceptibility to severe outcomes from viral infections and trauma, with trauma-related incidents significantly contributing to global mortality rates. This context underscores the critical need for a reliable blood supply. Recent research has focused on high molecular weight (MW) polymerized human hemoglobin (PolyhHb) as a promising alternative to red blood cells (RBCs), showing encouraging outcomes in previous studies. Given the overlap of metabolic disorders and trauma-related health issues, it is crucial to assess the potential toxicity of PolyhHb transfusions, particularly in models that represent these vulnerable populations. This study evaluated the effects of PolyhHb exchange transfusion in guinea pigs that had developed metabolic disorders due to a 12-week HFHSD regimen. The guinea pigs, underwent a 20â¯% blood volume exchange transfusion with either PolyhHb or the lower molecular weight polymerized bovine hemoglobin, Oxyglobin. Results revealed that both PolyhHb and Oxyglobin transfusions led to liver damage, with a more pronounced effect observed in HFHSD-fed animals. Additionally, markers of cardiac dysfunction indicated signs of cardiac injury in both the HFHSD and normal diet groups following the Oxyglobin transfusion. This study highlights how pre-existing metabolic disorders can exacerbate the potential side effects of hemoglobin-based oxygen carriers (HBOCs). Importantly, the newer generation of high MW PolyhHb showed lower cardiac toxicity compared to the earlier generation low MW PolyhHb, known as Oxyglobin, even in models with pre-existing endothelial and metabolic challenges.
Assuntos
Doenças Cardiovasculares , Hemoglobinas , Doenças Metabólicas , Peso Molecular , Animais , Hemoglobinas/metabolismo , Hemoglobinas/farmacologia , Cobaias , Masculino , Modelos Animais de Doenças , Dieta Hiperlipídica/efeitos adversos , Humanos , Substitutos Sanguíneos/farmacologiaRESUMO
Virion-mediated outbreaks are imminent and despite rapid responses, continue to cause adverse symptoms and death. Therefore, tunable, sensitive, high-throughput assays are needed to help diagnose future virion-mediated outbreaks. Herein, it is developed a tunable in situ assay to selectively enrich virions and extracellular vesicles (EVs) and simultaneously detect antigens and nucleic acids at a single-particle resolution. The Biochip Antigen and RNA Assay (BARA) enhanced sensitivities compared to quantitative reverse-transcription polymerase chain reaction (qRT-PCR), enabling the detection of virions in asymptomatic patients, genetic mutations in single virions, and enabling the continued long-term expression of viral RNA in the EV-enriched subpopulation in the plasma of patients with post-acute sequelae of the coronavirus disease of 2019 (COVID-19). BARA revealed highly accurate diagnoses of COVID-19 by simultaneously detecting the spike glycoprotein and nucleocapsid-encoding RNA in saliva and nasopharyngeal swab samples. Altogether, the single-particle detection of antigens and viral RNA provides a tunable framework for the diagnosis, monitoring, and mutation screening of current and future outbreaks.
RESUMO
Alpha-alpha diaspirin-crosslinked human hemoglobin (DCLHb or ααHb) was a promising early generation red blood cell (RBC) substitute. The DCLHb was developed through a collaborative effort between the United States Army and Baxter Healthcare. The core design feature underlying its development was chemical stabilization of the tetrameric structure of hemoglobin (Hb) to prevent Hb intravascular dimerization and extravasation. DCLHb was developed to resuscitate warfighters on the battlefield, who suffered from life-threatening blood loss. However, extensive research revealed toxic side effects associated with the use of DCLHb that contributed to high mortality rates in clinical trials. This study explores whether scavenging Hb and heme via the apohemoglobin-haptoglobin (apoHb-Hp) complex can reduce DCLHb associated toxicity. Awake Golden Syrian hamsters were equipped with a window chamber model to characterize the microcirculation. Each group was first infused with either Lactated Ringer's or apoHb-Hp followed by a hypovolemic infusion of 10% of the animal's blood volume of DCLHb. Our results indicated that animals pretreated with apoHb-Hb exhibited improved microhemodynamics vs the group pretreated with Lactated Ringer's. While systemic acute inflammation was observed regardless of the treatment group, apoHb-Hp pretreatment lessened those effects with a marked reduction in IL-6 levels in the heart and kidneys compared to the control group. Taken together, this study demonstrated that utilizing a Hb and heme scavenger protein complex significantly reduces the microvasculature effects of ααHb, paving the way for improved HBOC formulations. Future apoHb-Hp dose optimization studies may identify a dose that can completely neutralize DCLHb toxicity.
Assuntos
Haptoglobinas , Hemoglobinas , Animais , Hemoglobinas/farmacologia , Hemoglobinas/metabolismo , Humanos , Haptoglobinas/metabolismo , Masculino , Mesocricetus , Apoproteínas/química , Apoproteínas/farmacologia , Substitutos Sanguíneos/farmacologia , Substitutos Sanguíneos/química , Reagentes de Ligações Cruzadas/química , CricetinaeRESUMO
Normothermic ex vivo lung perfusion (EVLP) can resuscitate marginal lung allografts to increase organs available for transplantation. During normothermic perfusion, cellular metabolism is more active compared with subnormothermic perfusion, creating a need for an oxygen (O 2 ) carrier in the perfusate. As an O 2 carrier, red blood cells (RBCs) are a scarce resource and are susceptible to hemolysis in perfusion circuits, thus releasing cell-free hemoglobin (Hb), which can extravasate into the tissue space, thus promoting scavenging of nitric oxide (NO) and oxidative tissue damage. Fortunately, polymerized human Hb (PolyhHb) represents a synthetic O 2 carrier with a larger molecular diameter compared with Hb, preventing extravasation, and limiting adverse reactions. In this study, a next-generation PolyhHb-based perfusate was compared to both RBC and asanguinous perfusates in a rat EVLP model. During EVLP, the pulmonary arterial pressure and pulmonary vascular resistance were both significantly higher in lungs perfused with RBCs, which is consistent with RBC hemolysis. Lungs perfused with PolyhHb demonstrated greater oxygenation than those perfused with RBCs. Post-EVLP analysis revealed that the PolyhHb perfusate elicited less cellular damage, extravasation, iron tissue deposition, and edema than either RBCs or colloid control. These results show promise for a next-generation PolyhHb to maintain lung function throughout EVLP.
Assuntos
Substitutos Sanguíneos , Hemoglobinas , Transplante de Pulmão , Perfusão , Ratos Sprague-Dawley , Hemoglobinas/administração & dosagem , Animais , Transplante de Pulmão/métodos , Transplante de Pulmão/efeitos adversos , Ratos , Perfusão/métodos , Humanos , Substitutos Sanguíneos/farmacologia , Masculino , Pulmão , Oxigênio/metabolismo , Aloenxertos , Hemólise/efeitos dos fármacos , EritrócitosRESUMO
The molecular heterogeneity of extracellular vesicles (EVs) and the co-isolation of physically similar particles, such as lipoproteins (LPs), confounds and limits the sensitivity of EV bulk biomarker characterization. Herein, we present a single-EV and particle (siEVP) protein and RNA assay (siEVP PRA) to simultaneously detect mRNAs, miRNAs, and proteins in subpopulations of EVs and LPs. The siEVP PRA immobilizes and sorts particles via positive immunoselection onto micropatterns and focuses biomolecular signals in situ. By detecting EVPs at a single-particle resolution, the siEVP PRA outperformed the sensitivities of bulk-analysis benchmark assays for RNA and protein. To assess the specificity of RNA detection in complex biofluids, EVs from various glioma cell lines were processed with small RNA sequencing, whereby two mRNAs and two miRNAs associated with glioblastoma multiforme (GBM) were chosen for cross-validation. Despite the presence of single-EV-LP co-isolates in serum, the siEVP PRA detected GBM-associated vesicular RNA profiles in GBM patient siEVPs. The siEVP PRA effectively examines intravesicular, intervesicular, and interparticle heterogeneity with diagnostic promise.
Assuntos
Vesículas Extracelulares , Glioblastoma , MicroRNAs , Humanos , Vesículas Extracelulares/genética , Vesículas Extracelulares/metabolismo , Lipopolissacarídeos , MicroRNAs/genética , MicroRNAs/metabolismo , RNA Mensageiro , Lipoproteínas , Glioblastoma/diagnóstico , Glioblastoma/genéticaRESUMO
Polymerized human hemoglobin (PolyhHb) has shown promise in preclinical hemorrhagic shock settings. Different synthetic and purification schemes can control the size of PolyhHbs, yet research is lacking on the impact of polymerized hemoglobin size on tissue oxygenation following hemorrhage and resuscitation in specialized animal models that challenge their resuscitative capabilities. Pre-existing conditions that compromise the vasculature and end organs, such as the liver, may limit the effectiveness of resuscitation and exacerbate the toxicity of these molecules, which is an important but minimally explored therapeutic dimension. In this study, we compared the effective oxygen delivery of intermediate molecular weight PolyhHb (PolyhHb-B3; 500-750 kDa) to high molecular weight PolyhHb (PolyhHb-B4; 750 kDa-0.2 µm) for resuscitative effectiveness in guinea pig models subjected to hemorrhagic shock. We evaluated how the size of PolyhHb impacts hemodynamics and tissue oxygenation in normal guinea pigs and guinea pigs on an atherogenic diet. We observed that while PolyhHb-B3 and -B4 equivalently restore hemodynamic parameters of normal-dieted guinea pigs, high-fat-dieted guinea pigs resuscitated with PolyhHb-B4 have lower mean arterial pressures, impaired tissue oxygenation, and higher plasma lactate levels than those receiving PolyhHb-B3. We characterized the plasma of these animals following resuscitation and found that despite similar oxygen delivery kinetics, circulating PolyhHb-B3 and -B4 demonstrated a size-dependent increase in the plasma viscosity, consistent with impaired perfusion in the PolyhHb-B4 transfusion group. We conclude that intermediate-sized PolyhHbs (such as -B3) are ideal for further research given the effective resuscitation of hemorrhagic shock based on tissue oxygenation in hypercholesterolemic guinea pigs.
Assuntos
Hipercolesterolemia , Choque Hemorrágico , Humanos , Cobaias , Animais , Choque Hemorrágico/tratamento farmacológico , Hipercolesterolemia/tratamento farmacológico , Oxigênio , Hemodinâmica , HemoglobinasRESUMO
Tumor-associated immune cells play a crucial role in cancer progression. Myeloid-derived suppressor cells (MDSCs), for example, are immature innate immune cells that infiltrate the tumor to exert immunosuppressive activity and protect cancer cells from the host's immune system and/or cancer-specific immunotherapies. While tumor-associated immune cells have emerged as a promising therapeutic target, efforts to counter immunosuppression within the tumor niche have been hampered by the lack of approaches that selectively target the immune cell compartment of the tumor, to effectively eliminate "tumor-protecting" immune cells and/or drive an "anti-tumor" phenotype. Here we report on a novel nanotechnology-based approach to target tumor-associated immune cells and promote "anti-tumor" responses in a murine model of breast cancer. Engineered extracellular vesicles (EVs) decorated with ICAM-1 ligands and loaded with miR-146a and Glut1, were biosynthesized (in vitro or in vivo) and administered to tumor-bearing mice once a week for up to 5 weeks. The impact of this treatment modality on the immune cell compartment and tumor progression was evaluated via RT-qPCR, flow cytometry, and histology. Our results indicate that weekly administration of the engineered EVs (i.e., ICAM-1-decorated and loaded with miR-146a and Glut1) hampered tumor progression compared to ICAM-1-decorated EVs with no cargo. Flow cytometry analyses of the tumors indicated a shift in the phenotype of the immune cell population toward a more pro-inflammatory state, which appeared to have facilitated the infiltration of tumor-targeting T cells, and was associated with a reduction in tumor size and decreased metastatic burden. Altogether, our results indicate that ICAM-1-decorated EVs could be a powerful platform nanotechnology for the deployment of immune cell-targeting therapies to solid tumors.
RESUMO
Hemolysis (i.e., red blood cell lysis) can increase circulatory levels of cell-free hemoglobin (Hb) and its degradation by-products, namely heme (h) and iron (Fe). Under homeostasis, minor increases in these three hemolytic by-products (Hb/h/Fe) are rapidly scavenged and cleared by natural plasma proteins. Under certain pathophysiological conditions, scavenging systems become overwhelmed, leading to the accumulation of Hb/h/Fe in the circulation. Unfortunately, these species cause various side effects such as vasoconstriction, hypertension, and oxidative organ damage. Therefore, various therapeutics strategies are in development, ranging from supplementation with depleted plasma scavenger proteins to engineered biomimetic protein constructs capable of scavenging multiple hemolytic species. In this review, we briefly describe hemolysis and the characteristics of the major plasma-derived protein scavengers of Hb/h/Fe. Finally, we present novel engineering approaches designed to address the toxicity of these hemolytic by-products.
Assuntos
Heme , Hemólise , Humanos , Heme/metabolismo , Hemólise/fisiologia , Ferro , Haptoglobinas/metabolismo , Haptoglobinas/uso terapêutico , Hemoglobinas/metabolismoRESUMO
The present study aimed to compare the ability of tense (T) and relaxed (R) quaternary state polymerized human hemoglobin (PolyhHb) to restore hemodynamics after severe trauma in a rat model, and to assess their relative toxicity in a guinea pigs (GPs). To assess the efficacy of these PolyhHbs in restoring hemodynamics, Wistar rats were subjected to traumatic brain injury (TBI) followed by hemorrhagic shock (HS). Animals were separated into 3 groups based on the resuscitation solution: Whole blood, T-state or R-state PolyhHb, and followed for 2 hours after resuscitation. For toxicity evaluation, GPs were subjected to HS and the hypovolemic state was maintained for 50 minutes. Then, the GPs were divided randomly into 2 groups, and reperfused with T- or R-state PolyhHb. Rats resuscitated with blood and T-state PolyhHb had a higher recovery of MAP at 30 min after resuscitation when compared to R-state PolyhHb, demonstrating the greater ability of T-state PolyhHb to restore hemodynamics compared to R-state PolyhHb. Resuscitation with R-state PolyhHb in GPs increased markers of liver damage and inflammation, kidney injury and systemic inflammation compared to the T-state PolyhHb group. Finally, increased levels of cardiac damage markers, such as troponin were observed, indicating greater cardiac injury in GPs resuscitated with R-state PolyhHb. Therefore, our results showed that T-state PolyhHb exhibited superior efficacy in a model of TBI followed by HS in rats, and presented reduced vital organ toxicity in GPs, when compared to R-state PolyhHb.
Assuntos
Lesões Encefálicas Traumáticas , Choque Hemorrágico , Animais , Cobaias , Humanos , Ratos , Modelos Animais de Doenças , Hemoglobinas , Oxigênio , Ratos WistarRESUMO
Hemoglobin (Hb) based oxygen carriers (HBOCs) are designed to minimize the toxicity of extracellular Hb, while preserving its high oxygen-carrying capacity for oxygen delivery to cells. Polymerized human Hb (PolyHb) is a novel type of nanosized HBOC synthesized via glutaraldehyde-mediated crosslinking of free Hb, and which preserves the predominant quaternary state during the crosslinking reaction (low oxygen affinity tense (T) quaternary state PolyHb is synthesized at 0% Hb oxygen saturation, and high oxygen affinity relaxed (R) quaternary state PolyHb is synthesized at 100% Hb oxygen saturation). Major potential applications for PolyHbs, and HBOCs in general, include oxygenation of bioreactor systems containing large liver cell masses, and ex-vivo perfusion preservation of explanted liver grafts. The toxicity of these compounds toward liver cells must be evaluated before testing their use in these complex systems for oxygen delivery. Herein, we characterized the effect of PolyHbs on the hepatoma cell line HepG2/C3A, used as a model hepatocyte and as a cell line used in some investigational bioartificial liver support devices. HepG2/C3A cells were incubated in cell culture media containing PolyHbs or unmodified Hb at concentrations up to 50 mg/mL and for up to 6 days. PolyHbs were well tolerated at a dose of 10 mg/mL, with no significant decrease in cell viability; however, proliferation was inhibited as much as 10-fold after 6 days of exposure at 50 mg/mL. Secretion of albumin, and urea, as well as glucose and ammonia removal were measured in presence of 10 mg/mL of PolyHbs or unmodified Hb. In addition, methoxy- and ethoxy-resorufin deacetylase (MROD and EROD) activities, which reflect cytochrome P450 metabolism, were measured. R-state PolyHb displayed improved or intact activity in 3 out of 7 functions compared to unmodified Hb. T-state PolyHb displayed improved or intact activity in 4 out of 7 functions compared to unmodified Hb. Thus, PolyHbs, both in the R-state and T-state, are safer to use at a concentration of 10 mg/mL as compared to unmodified Hb in static culture liver-related applications.
RESUMO
Due to several limitations associated with blood transfusion, such as the relatively short shelf life of stored blood, low risk of developing acute immune hemolytic reactions and graft-versus-host disease, many strategies have been developed to synthesize hemoglobin-based oxygen carriers (HBOCs) as universal red blood cell (RBC) substitutes. Recently, zeolite imidazole framework-8 (ZIF-8), a metal-organic framework, has attracted considerable attention as a protective scaffold for encapsulation of hemoglobin (Hb). Despite the exceptional thermal and chemical stability of ZIF-8, the major impediments to implementing ZIF-8 for Hb encapsulation are the structural distortions associated with loading large quantities of Hb in the scaffold as the Hb molecule has a larger hydrodynamic diameter than the pore size of ZIF-8. Therefore to reduce the structural distortion caused by Hb encapsulation, we established and optimized a continuous-injection method to synthesize nanoparticle (NP) encapsulated polymerized bovine Hb (PolybHb) using ZIF-8 precursors (ZIF-8P-PolybHb NPs). The synthesis method was further modified by adding EDTA as a chelating agent, which reduced the ZIF-8P-PolybHb NP size to <300 nm. ZIF-8P-PolybHb NPs exhibited lower oxygen affinity (36.4 ± 3.2 mm Hg) compared to unmodified bovine Hb, but was similar in magnitude to unencapsulated PolybHb. The use of the chemical cross-linker glutaraldehyde to polymerize bovine Hb resulted in the low Hill coefficient of PolybHb, indicating loss of Hb's oxygen binding cooperativity, which could be a limitation when using PolybHb as an oxygen carrier for encapsulation inside the ZIF-8 matrix. ZIF-8P-PolybHb NPs exhibited slower oxygen offloading kinetics compared to unencapsulated PolybHb, demonstrating successful encapsulation of PolybHb. ZIF-8P-PolybHb NPs also exhibited favorable antioxidant properties when exposed to H2O2. Incorporation of PolybHb into the ZIF-8 scaffold resulted in reduced cytotoxicity towards human umbilical vein endothelial cells compared to unloaded ZIF-8 NPs and ZIF-8 NPs loaded with bovine Hb. We envisage that such a monodisperse and biocompatible HBOC with low oxygen affinity and antioxidant properties may broaden its use as an RBC substitute.
Assuntos
Substitutos Sanguíneos , Estruturas Metalorgânicas , Nanopartículas , Zeolitas , Humanos , Estruturas Metalorgânicas/farmacologia , Antioxidantes/farmacologia , Zeolitas/farmacologia , Células Endoteliais/metabolismo , Peróxido de Hidrogênio , Hemoglobinas/farmacologia , Hemoglobinas/química , Imidazóis , Substitutos Sanguíneos/farmacologia , Substitutos Sanguíneos/química , Oxigênio/química , Eritrócitos/metabolismoRESUMO
Hemoglobin-based oxygen carriers (HBOCs) are being developed to overcome limitations associated with transfusion of donated red blood cells (RBCs) such as potential transmission of blood-borne pathogens and limited ex vivo storage shelf-life. Annelid erythrocruorin (Ec) derived from the worm Lumbricus terrestris (Lt) is an acellular mega-hemoglobin that has shown promise as a potential HBOC due to the large size of its oligomeric structure, thus overcoming limitations of unmodified circulating cell-free hemoglobin (Hb). With a large molecular weight of 3.6 MDa compared to 64.5 kDa for human Hb (hHb) and 144 oxygen-binding globin subunits compared to the 4 globin subunits of hHb, LtEc does not extravasate from the circulation to the same extent as hHb. LtEc is stable in the circulation without RBC membrane encapsulation and has a lower rate of auto-oxidation compared to acellular hHb, which allows the protein to remain functional for longer periods of time in the circulation compared to HBOCs derived from mammalian Hbs. Surface coatings, such as poly(ethylene glycol) (PEG) and oxidized dextran (Odex), have been investigated to potentially reduce the immune response and improve the circulation time of LtEc in vivo. Polydopamine (PDA) is a hydrophilic, biocompatible, bioinspired polymer coating used for biomedical nanoparticle assemblies and coatings and has previously been investigated for the surface coating of hHb. PDA is typically synthesized via the self-polymerization of dopamine (DA) under alkaline (pH > 8.0) conditions. However, at pH > 8.0, the oligomeric structure of LtEc begins to dissociate. Therefore, in this study, we investigated a photocatalytic method of PDA polymerization on the surface of LtEc using 9-mesityl-10-methylacridinium tetrafluoroborate (Acr-Mes) to drive PDA polymerization under physiological conditions (pH 7.4, 25 °C) over 2, 5, and 16 h in order to preserve the size and structure of LtEc. The resulting structural, biophysical, and antioxidant properties of PDA surface-coated LtEc (PDA-LtEc) was characterized using various techniques. PDA-LtEc showed an increase in measured particle size, molecular weight, and surface ζ-potential with increasing reaction time from t = 2 to 16 h compared to unmodified LtEc. PDA-LtEc reacted for 16 h was found to have reduced oxygen-binding cooperativity and slower deoxygenation kinetics compared to PDA-LtEc with lower levels of polymerization (t = 2 h), but there was no statistically significant difference in oxygen affinity. The thickness of the PDA coating can be controlled and in turn the biophysical properties can be tuned by changing various reaction conditions. PDA-LtEc was shown to demonstrate an increased level of antioxidant capacity (ferric iron reduction and free-radical scavenging) when synthesized at a reaction time of t = 16 h compared to LtEc. These antioxidant properties may prove beneficial for oxidative protection of PDA-LtEc during its time in the circulation. Hence, we believe that PDA-LtEc is a promising oxygen therapeutic for potential use in transfusion medicine applications.
Assuntos
Antioxidantes , Substitutos Sanguíneos , Animais , Humanos , Antioxidantes/farmacologia , Antioxidantes/química , Oxigênio/química , Substitutos Sanguíneos/farmacologia , Substitutos Sanguíneos/química , Hemoglobinas/química , Polímeros/química , Mamíferos/metabolismoRESUMO
Red blood cell (RBC) substitutes tested in late-phase clinical trials contained low-molecular-weight hemoglobin species (<500 kDa), resulting in vasoconstriction, hypertension, and oxidative tissue injury; therefore, contributing to poor clinical outcomes. This work aims to improve the safety profile of the RBC substitute, polymerized human hemoglobin (PolyhHb), via in vitro and in vivo screening of PolyhHb fractionated into four molecular weight brackets (50-300 kDa [PolyhHb-B1]; 100-500 kDa [PolyhHb-B2]; 500-750 kDa [PolyhHb-B3]; and 750 kDa to 0.2 µm [PolyhHb-B4]) using a two-stage tangential flow filtration purification process. Analysis showed that PolyhHb's oxygen affinity, and haptoglobin binding kinetics decreased with increasing bracket size. A 25% blood-for-PolyhHb exchange transfusion guinea pig model suggests that hypertension and tissue extravasation decreased with increasing bracket size. PolyhHb-B3 demonstrated extended circulatory pharmacokinetics, no renal tissue distribution, no aberrant blood pressure, or cardiac conduction effects, and may therefore be appropriate material for further evaluation.
Assuntos
Substitutos Sanguíneos , Hemoglobinas , Humanos , Animais , Cobaias , Hemoglobinas/química , Oxigênio/metabolismo , Polimerização , Substitutos Sanguíneos/farmacologia , Eritrócitos/metabolismoRESUMO
Ex vivo lung perfusion (EVLP) is a method of organ preservation to expand the donor pool by allowing organ assessment and repair. Perfusion solution composition is crucial to maintaining and improving organ function during EVLP. EVLP compared perfusates supplemented with either polymeric human serum albumin (PolyHSA) or standard human serum albumin (HSA). Rat heart-lung blocks underwent normothermic EVLP (37°C) for 120 minutes using perfusate with 4% HSA or 4% PolyHSA synthesized at a 50:1 or 60:1 molar ratio of glutaraldehyde to PolyHSA. Oxygen delivery, lung compliance, pulmonary vascular resistance (PVR), wet-to-dry ratio, and lung weight were measured. Perfusion solution type (HSA or PolyHSA) significantly impacted end-organ metrics. Oxygen delivery, lung compliance, and PVR were comparable among groups ( P > 0.05). Wet-to-dry ratio increased in the HSA group compared to the PolyHSA groups (both P < 0.05) suggesting edema formation. Wet-to-dry ratio was most favorable in the 60:1 PolyHSA-treated lungs compared to HSA ( P < 0.05). Compared to using HSA, PolyHSA significantly lessened lung edema. Our data confirm that the physical properties of perfusate plasma substitutes significantly impact oncotic pressure and the development of tissue injury and edema. Our findings demonstrate the importance of perfusion solutions and PolyHSA is an excellent candidate macromolecule to limit pulmonary edema. http://links.lww.com/ASAIO/A980.
Assuntos
Transplante de Pulmão , Humanos , Animais , Ratos , Transplante de Pulmão/métodos , Pulmão , Perfusão/métodos , Albumina Sérica Humana , Preservação de Órgãos/métodos , OxigênioRESUMO
For the past thirty years, hemoglobin-based oxygen carriers (HBOCs) have been under development as a red blood cell substitute. Side-effects such as vasoconstriction, oxidative injury, and cardiac toxicity have prevented clinical approval of HBOCs. Recently, high molecular weight (MW) polymerized human hemoglobin (PolyhHb) has shown positive results in rats. Studies have demonstrated that high MW PolyhHb increased O2 delivery, with minimal effects on blood pressure, without vasoconstriction, and devoid of toxicity. In this study, we used guinea pigs to evaluate the efficacy and safety of high MW PolyhHb, since like humans guinea pigs cannot produce endogenous ascorbic acid, which limits the capacity of both species to deal with oxidative stress. Hence, this study evaluated the efficacy and safety of resuscitation from severe hemorrhagic shock with high MW PolyhHb, fresh blood, and blood stored for 2 weeks. Animals were randomly assigned to each experimental group, and hemorrhage was induced by the withdrawal of 40% of the blood volume (BV, estimated as 7.5% of body weight) from the carotid artery catheter. Hypovolemic shock was maintained for 50 min. Resuscitation was implemented by infusing 25% of the animal's BV with the different treatments. Hemodynamics, blood gases, total hemoglobin, and lactate were not different before hemorrhage and during shock between groups. The hematocrit was lower for the PolyhHb group compared to the fresh and stored blood groups after resuscitation. Resuscitation with stored blood had lower blood pressure compared to fresh blood at 2 h. There was no difference in mean arterial pressure between groups at 24 h. Resuscitation with PolyhHb was not different from fresh blood for most parameters. Resuscitation with PolyhHb did not show any remarkable change in liver injury, inflammation, or cardiac damage. Resuscitation with stored blood showed changes in liver function and inflammation, but no kidney injury or systemic inflammation. Resuscitation with stored blood after 24 h displayed sympathetic hyper-activation and signs of cardiac injury. These results suggest that PolyhHb is an effective resuscitation alternative to blood. The decreased toxicities in terms of cardiac injury markers, vital organ function, and inflammation following PolyhHb resuscitation in guinea pigs indicate a favorable safety profile. These results are promising and support future studies with this new generation of PolyhHb as alternative to blood when blood is unavailable.