Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
JACC Cardiovasc Interv ; 16(20): 2479-2497, 2023 10 23.
Artigo em Inglês | MEDLINE | ID: mdl-37879802

RESUMO

Artificial intelligence, computational simulations, and extended reality, among other 21st century computational technologies, are changing the health care system. To collectively highlight the most recent advances and benefits of artificial intelligence, computational simulations, and extended reality in cardiovascular therapies, we coined the abbreviation AISER. The review particularly focuses on the following applications of AISER: 1) preprocedural planning and clinical decision making; 2) virtual clinical trials, and cardiovascular device research, development, and regulatory approval; and 3) education and training of interventional health care professionals and medical technology innovators. We also discuss the obstacles and constraints associated with the application of AISER technologies, as well as the proposed solutions. Interventional health care professionals, computer scientists, biomedical engineers, experts in bioinformatics and visualization, the device industry, ethics committees, and regulatory agencies are expected to streamline the use of AISER technologies in cardiovascular interventions and medicine in general.


Assuntos
Inteligência Artificial , Humanos , Resultado do Tratamento
2.
Heart Rhythm ; 20(12): 1669-1673, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37591366

RESUMO

BACKGROUND: Same-day discharge (SDD) after cardiovascular procedures is rapidly gaining ground. OBJECTIVE: We sought to evaluate the safety of SDD after transvenous lead extraction (TLE). METHODS: We performed a retrospective chart review of patients who underwent elective TLE between January 2020 and October 2021 at our institution. The primary outcome was SDD, and major procedural complications and readmissions within 30 days of the procedure were secondary outcomes. RESULTS: In this analysis of 111 patients who underwent elective TLE, 80 patients (72%) were discharged on the same day (SDD group) while 31 patients (28%) stayed overnight (overnight group). Lead malfunction was the most common indication for TLE in both groups. Patients in the overnight group were more likely to have a lead dwell time of ≤10 years than those in the SDD group (38.7% vs 20% of all leads in each group; P = .042), have laser sheaths used for extraction and a higher number of leads extracted. No major complications were reported in both groups. In a multivariate analysis, lower body mass index and the use of laser sheath during TLE were predictors of overnight stay. Patients who underwent a procedure using advanced extraction techniques were 3.5 times more likely to stay overnight (95% confidence interval 1.27-9.78; P = .016). CONCLUSION: In appropriately selected patients undergoing elective lead extraction, SDD is feasible and safe. Higher body mass index, fewer extracted leads, shorter lead dwell times (<10 years), and less frequent use of laser-powered extraction sheaths were associated with an increased likelihood of SDD.


Assuntos
Desfibriladores Implantáveis , Alta do Paciente , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos
3.
PLoS One ; 18(3): e0281423, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36867601

RESUMO

INTRODUCTION: Coronary artery bypass graft surgery (CABG) is an intervention in patients with extensive obstructive coronary artery disease diagnosed with invasive coronary angiography. Here we present and test a novel application of non-invasive computational assessment of coronary hemodynamics before and after bypass grafting. METHODS AND RESULTS: We tested the computational CABG platform in n = 2 post-CABG patients. The computationally calculated fractional flow reserve showed high agreement with the angiography-based fractional flow reserve. Furthermore, we performed multiscale computational fluid dynamics simulations of pre- and post-CABG under simulated resting and hyperemic conditions in n = 2 patient-specific anatomies 3D reconstructed from coronary computed tomography angiography. We computationally created different degrees of stenosis in the left anterior descending artery, and we showed that increasing severity of native artery stenosis resulted in augmented flow through the graft and improvement of resting and hyperemic flow in the distal part of the grafted native artery. CONCLUSIONS: We presented a comprehensive patient-specific computational platform that can simulate the hemodynamic conditions before and after CABG and faithfully reproduce the hemodynamic effects of bypass grafting on the native coronary artery flow. Further clinical studies are warranted to validate this preliminary data.


Assuntos
Reserva Fracionada de Fluxo Miocárdico , Hiperemia , Humanos , Constrição Patológica , Ponte de Artéria Coronária , Vasos Coronários , Angiografia Coronária
4.
Sci Rep ; 13(1): 4656, 2023 03 21.
Artigo em Inglês | MEDLINE | ID: mdl-36944850

RESUMO

This study sought to investigate the role of triggering receptor expressed on myeloid cells-1 (TREM-1) in the mechanotransduction signaling pathways that link low shear stress with inflammation. Human coronary artery endothelial cells, human coronary artery smooth muscle cells, and THP-1 monocytes were co-cultured and exposed to varying endothelial shear stress (ESS) conditions: low (5 ± 3 dynes/cm2), medium (10 ± 3 dynes/cm2), and high (15 ± 3 dynes/cm2). We showed that low ESS increased the expression of TREM-1 by the cultured cells leading to increased production of inflammatory mediators and matrix-degrading enzymes, whereas high ESS did not have a significant effect in the expression of TREM-1 and inflammatory mediators. Furthermore, TREM-1 transcriptional inhibition with siRNA in endothelial cells, smooth muscle cells, and monocytes exposed to low ESS, led to a significant reduction in the production of vascular inflammatory mediators and matrix-degrading enzymes. Additionally, we identified the transcription factors that appear to upregulate the TREM-1 gene expression in response to low ESS. To the best of our knowledge, this is the first study to investigate the pathophysiologic association and molecular pathways that link low ESS, TREM-1, and inflammation using a sophisticated in-vitro model of atherosclerosis. Future studies on animals and humans are warranted to investigate the potential of TREM-1 inhibitors as adjunctive anti-atherosclerotic therapies.


Assuntos
Aterosclerose , Mecanotransdução Celular , Transdução de Sinais , Receptor Gatilho 1 Expresso em Células Mieloides , Humanos , Aterosclerose/metabolismo , Células Endoteliais/metabolismo , Inflamação/metabolismo , Mediadores da Inflamação/metabolismo , Receptor Gatilho 1 Expresso em Células Mieloides/metabolismo
5.
Front Endocrinol (Lausanne) ; 13: 780872, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35721716

RESUMO

Background: Obesity affects the course of critical illnesses. We aimed to estimate the association of obesity with the severity and mortality in coronavirus disease 2019 (COVID-19) patients. Data Sources: A systematic search was conducted from the inception of the COVID-19 pandemic through to 13 October 2021, on databases including Medline (PubMed), Embase, Science Web, and Cochrane Central Controlled Trials Registry. Preprint servers such as BioRxiv, MedRxiv, ChemRxiv, and SSRN were also scanned. Study Selection and Data Extraction: Full-length articles focusing on the association of obesity and outcome in COVID-19 patients were included. Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines were used for study selection and data extraction. Our Population of interest were COVID-19 positive patients, obesity is our Intervention/Exposure point, Comparators are Non-obese vs obese patients The chief outcome of the study was the severity of the confirmed COVID-19 positive hospitalized patients in terms of admission to the intensive care unit (ICU) or the requirement of invasive mechanical ventilation/intubation with obesity. All-cause mortality in COVID-19 positive hospitalized patients with obesity was the secondary outcome of the study. Results: In total, 3,140,413 patients from 167 studies were included in the study. Obesity was associated with an increased risk of severe disease (RR=1.52, 95% CI 1.41-1.63, p<0.001, I2 = 97%). Similarly, high mortality was observed in obese patients (RR=1.09, 95% CI 1.02-1.16, p=0.006, I2 = 97%). In multivariate meta-regression on severity, the covariate of the female gender, pulmonary disease, diabetes, older age, cardiovascular diseases, and hypertension was found to be significant and explained R2 = 40% of the between-study heterogeneity for severity. The aforementioned covariates were found to be significant for mortality as well, and these covariates collectively explained R2 = 50% of the between-study variability for mortality. Conclusions: Our findings suggest that obesity is significantly associated with increased severity and higher mortality among COVID-19 patients. Therefore, the inclusion of obesity or its surrogate body mass index in prognostic scores and improvement of guidelines for patient care management is recommended.


Assuntos
COVID-19 , COVID-19/complicações , Feminino , Hospitalização , Humanos , Obesidade/complicações , Obesidade/epidemiologia , Pandemias , Respiração Artificial
6.
JACC Case Rep ; 4(6): 325-335, 2022 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-35495558

RESUMO

Left main coronary artery stenting requires rigorous planning and optimal execution. This case series presents a new approach to left main stenting guided by preprocedural patient-specific computational simulations. Three patients with significant left main artery disease underwent simulation-guided intervention using a novel stent scaffold purpose-built for large coronary arteries. (Level of Difficulty: Advanced.).

7.
Pharmacol Ther ; 238: 108182, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35390422

RESUMO

Triggering receptor expressed on myeloid cells-1 (TREM-1) is a transmembrane protein expressed on endothelial cells, white blood cells, smooth muscle cells and platelets. TREM-1 plays an important role in innate immunity. TREM-1 activation pathways are implicated both in sepsis and in non-infectious inflammatory conditions, including atherosclerosis. TREM-1 enhances the subendothelial lipid accumulation and expression of pro-inflammatory cytokines and matrix-degrading enzymes, thereby promoting inflammation and plaque destabilization. TREM-1 inhibitors attenuate the inflammatory process in the atherosclerotic plaque, leading to plaque stabilization. This review focuses on the role of TREM-1 in the pathophysiology of atherosclerosis and the effects of TREM-1 inhibition in the natural history of the disease.


Assuntos
Aterosclerose , Placa Aterosclerótica , Aterosclerose/tratamento farmacológico , Aterosclerose/metabolismo , Citocinas/metabolismo , Células Endoteliais/metabolismo , Humanos , Lipídeos , Placa Aterosclerótica/metabolismo , Receptor Gatilho 1 Expresso em Células Mieloides/metabolismo
8.
Thromb Res ; 211: 106-113, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35149395

RESUMO

Venous thromboembolism (VTE) in pregnancy, consisting of deep venous thrombosis (DVT) and pulmonary embolism (PE), is a major factor of maternal mortality. Several patient-specific risk factors along with the physiologic changes of pregnancy promote a state of hypercoagulability in pregnant women. Detailed assessment of all pregnant women can establish a risk profile that would guide clinical decisions, and balance potential therapeutic benefits with side effects. Differentiating between physiologic changes of pregnancy and symptoms of VTE can be challenging and warrants meticulous clinical evaluation. Timely and accurate diagnosis of VTE with proper imaging is essential for its management, and systemic anticoagulation remains the cornerstone of VTE prevention and therapy. Furthermore, advanced invasive treatment options such as inferior vena cava filters and thrombectomy can be considered for complex cases. Importantly, the risk of systemic anticoagulation should be balanced against the risk of VTE-associated morbidity and mortality for mother and fetus, and an informed decision should be made. In this review, we present an up-to-date overview of VTE management in pregnancy and the postpartum period.


Assuntos
Embolia Pulmonar , Trombofilia , Filtros de Veia Cava , Tromboembolia Venosa , Anticoagulantes/uso terapêutico , Feminino , Humanos , Gravidez , Embolia Pulmonar/etiologia , Fatores de Risco , Trombofilia/tratamento farmacológico , Filtros de Veia Cava/efeitos adversos , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/tratamento farmacológico
9.
Sci Rep ; 11(1): 16486, 2021 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-34389748

RESUMO

Patient-specific and lesion-specific computational simulation of bifurcation stenting is an attractive approach to achieve individualized pre-procedural planning that could improve outcomes. The objectives of this work were to describe and validate a novel platform for fully computational patient-specific coronary bifurcation stenting. Our computational stent simulation platform was trained using n = 4 patient-specific bench bifurcation models (n = 17 simulations), and n = 5 clinical bifurcation cases (training group, n = 23 simulations). The platform was blindly tested in n = 5 clinical bifurcation cases (testing group, n = 29 simulations). A variety of stent platforms and stent techniques with 1- or 2-stents was used. Post-stenting imaging with micro-computed tomography (µCT) for bench group and optical coherence tomography (OCT) for clinical groups were used as reference for the training and testing of computational coronary bifurcation stenting. There was a very high agreement for mean lumen diameter (MLD) between stent simulations and post-stenting µCT in bench cases yielding an overall bias of 0.03 (- 0.28 to 0.34) mm. Similarly, there was a high agreement for MLD between stent simulation and OCT in clinical training group [bias 0.08 (- 0.24 to 0.41) mm], and clinical testing group [bias 0.08 (- 0.29 to 0.46) mm]. Quantitatively and qualitatively stent size and shape in computational stenting was in high agreement with clinical cases, yielding an overall bias of < 0.15 mm. Patient-specific computational stenting of coronary bifurcations is a feasible and accurate approach. Future clinical studies are warranted to investigate the ability of computational stenting simulations to guide decision-making in the cardiac catheterization laboratory and improve clinical outcomes.


Assuntos
Prótese Vascular , Simulação por Computador , Doença da Artéria Coronariana/cirurgia , Stents , Implante de Prótese Vascular , Doença da Artéria Coronariana/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Cuidados Pré-Operatórios/métodos , Desenho de Prótese/métodos , Microtomografia por Raio-X
10.
Sci Rep ; 11(1): 12252, 2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112841

RESUMO

The structural morphology of coronary stents (e.g. stent expansion, lumen scaffolding, strut apposition, tissue protrusion, side branch jailing, strut fracture), and the local hemodynamic environment after stent deployment are key determinants of procedural success and subsequent clinical outcomes. High-resolution intracoronary imaging has the potential to enable the geometrically accurate three-dimensional (3D) reconstruction of coronary stents. The aim of this work was to present a novel algorithm for 3D stent reconstruction of coronary artery stents based on optical coherence tomography (OCT) and angiography, and test experimentally its accuracy, reproducibility, clinical feasibility, and ability to perform computational fluid dynamics (CFD) studies. Our method has the following steps: 3D lumen reconstruction based on OCT and angiography, stent strut segmentation in OCT images, packaging, rotation and straightening of the segmented struts, planar unrolling of the segmented struts, planar stent wireframe reconstruction, rolling back of the planar stent wireframe to the 3D reconstructed lumen, and final stent volume reconstruction. We tested the accuracy and reproducibility of our method in stented patient-specific silicone models using micro-computed tomography (µCT) and stereoscopy as references. The clinical feasibility and CFD studies were performed in clinically stented coronary bifurcations. The experimental and clinical studies showed that our algorithm (1) can reproduce the complex spatial stent configuration with high precision and reproducibility, (2) is feasible in 3D reconstructing stents deployed in bifurcations, and (3) enables CFD studies to assess the local hemodynamic environment within the stent. Notably, the high accuracy of our algorithm was consistent across different stent designs and diameters. Our method coupled with patient-specific CFD studies can lay the ground for optimization of stenting procedures, patient-specific computational stenting simulations, and research and development of new stent scaffolds and stenting techniques.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/cirurgia , Imageamento Tridimensional , Stents , Cirurgia Assistida por Computador , Tomografia de Coerência Óptica , Algoritmos , Angiografia Coronária , Doença da Artéria Coronariana/patologia , Vasos Coronários/patologia , Humanos , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/métodos , Tomografia de Coerência Óptica/métodos , Microtomografia por Raio-X
11.
Sci Rep ; 11(1): 8728, 2021 04 22.
Artigo em Inglês | MEDLINE | ID: mdl-33888765

RESUMO

Left main (LM) coronary artery bifurcation stenting is a challenging topic due to the distinct anatomy and wall structure of LM. In this work, we investigated computationally and experimentally the mechanical performance of a novel everolimus-eluting stent (SYNERGY MEGATRON) purpose-built for interventions to large proximal coronary segments, including LM. MEGATRON stent has been purposefully designed to sustain its structural integrity at higher expansion diameters and to provide optimal lumen coverage. Four patient-specific LM geometries were 3D reconstructed and stented computationally with finite element analysis in a well-validated computational stent simulation platform under different homogeneous and heterogeneous plaque conditions. Four different everolimus-eluting stent designs (9-peak prototype MEGATRON, 10-peak prototype MEGATRON, 12-peak MEGATRON, and SYNERGY) were deployed computationally in all bifurcation geometries at three different diameters (i.e., 3.5, 4.5, and 5.0 mm). The stent designs were also expanded experimentally from 3.5 to 5.0 mm (blind analysis). Stent morphometric and biomechanical indices were calculated in the computational and experimental studies. In the computational studies the 12-peak MEGATRON exhibited significantly greater expansion, better scaffolding, smaller vessel prolapse, and greater radial strength (expressed as normalized hoop force) than the 9-peak MEGATRON, 10-peak MEGATRON, or SYNERGY (p < 0.05). Larger stent expansion diameters had significantly better radial strength and worse scaffolding than smaller stent diameters (p < 0.001). Computational stenting showed comparable scaffolding and radial strength with experimental stenting. 12-peak MEGATRON exhibited better mechanical performance than the 9-peak MEGATRON, 10-peak MEGATRON, or SYNERGY. Patient-specific computational LM stenting simulations can accurately reproduce experimental stent testing, providing an attractive framework for cost- and time-effective stent research and development.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/administração & dosagem , Doença da Artéria Coronariana/tratamento farmacológico , Desenho de Equipamento , Humanos
12.
Photochem Photobiol ; 97(4): 826-836, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33386640

RESUMO

Photochemo and photodynamic therapies are minimally invasive approaches for the treatment of cancers and powerful weapons for competing bacterial resistance to antibiotics. Synthetic and naturally occurring quinazolinones are considered privileged anticancer and antibacterial agents, with several of them to have emerged as commercially available drugs. In the present study, applying a single-step green microwave irradiation mediated protocol we have synthesized eleven quinazolinon-4(3H)-ones, from cheap readily available anthranilic acids, in very good yields and purity. These products were irradiated in the presence of pBR322 plasmid DNA under UVB, UVA and visible light. Four of the compounds proved to be very effective DNA photocleavers, at low concentrations, being time and concentration dependent as well as pH independent. Participation of reactive oxygen species was related to the substitution of quinazolinone derivatives. 6-Nitro-quinazolinone in combination with UVA irradiation was found to be in vitro photodestructive for three cell lines; glioblastoma (U87MG and T98G) and mainly melanoma (A-375). Thus, certain appropriately substituted quinazolinones may serve as new lead photosensitizers for the development of promising biotechnological applications and as novel photochemo and photodynamic therapeutics.


Assuntos
Melanoma , Antibacterianos/farmacologia , Linhagem Celular , Humanos , Quinazolinonas/farmacologia , Relação Estrutura-Atividade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA