Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
2.
J Interv Card Electrophysiol ; 66(1): 27-38, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35072829

RESUMO

BACKGROUND: Arrhythmic death is very common among patients with structural heart disease, and it is estimated that in European countries, 1 per 1000 inhabitants yearly dies for sudden cardiac death (SCD), mainly as a result of ventricular arrhythmias (VA). The scar is the result of cardiac remodelling process that occurs in several cardiomyopathies, both ischemic and non-ischemic, and is considered the perfect substrate for re-entrant and non-re-entrant arrhythmias. METHODS: Our aim was to review published evidence on the histological and electrophysiological properties of myocardial scar and to review the central role of cardiac magnetic resonance (CMR) in assessing ventricular arrhythmias substrate and its potential implication in risk stratification of SCD. RESULTS: Scarring process affects both structural and electrical myocardial properties and paves the background for enhanced arrhythmogenicity. Non-uniform anisotropic conduction, gap junctions remodelling, source to sink mismatch and refractoriness dispersion are some of the underlining mechanisms contributing to arrhythmic potential of the scar. All these mechanisms lead to the initiation and maintenance of VA. CMR has a crucial role in the evaluation of patients suffering from VA, as it is considered the gold standard imaging test for scar characterization. Mounting evidences support the use of CMR not only for the definition of gross scar features, as size, localization and transmurality, but also for the identification of possible conducting channels suitable of discrete ablation. Moreover, several studies call out the CMR-based scar characterization as a stratification tool useful in selecting patients at risk of SCD and amenable to implantable cardioverter-defibrillator (ICD) implantation. CONCLUSIONS: Scar represents the substrate of ventricular arrhythmias. CMR, defining scar presence and its features, may be a useful tool for guiding ablation procedures and for identifying patients at risk of SCD amenable to ICD therapy.


Assuntos
Cardiomiopatias , Desfibriladores Implantáveis , Humanos , Cicatriz/diagnóstico por imagem , Cicatriz/patologia , Vento , Arritmias Cardíacas/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/terapia , Morte Súbita Cardíaca/prevenção & controle , Fatores de Risco
3.
Minerva Cardioangiol ; 59(1): 9-15, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21285927

RESUMO

AIM: The aim of this study was to assess if knowing the interatrial conduction time is useful to better program atrioventricular delay in sequential pacing. The study proposes a new echo-Doppler method to measure interatrial conduction time, correlating it with electrophysiological measures. METHODS: The new method was tested in 30 subjects who underwent electrophysiological study. Interatrial conduction time by new method was taken during atrial pacing as the interval between the artefact of electrocardiogram pacing, shown on screen echo, and the onset of the A wave of the echo-Doppler mitral inflow. The electrophysiological measures were obtained, in the same subjects and at the same time, by a decapolar catheter in coronary sinus as intervals between the artefact of atrial pacing and the first positive left atrial deflection at proximal (C7C8) and distal (C1C2) electrodes. RESULTS: Echo-Doppler mean time was 114±12 ms, electrophysiological time was 107±14 ms at C7C8 and 124±11 ms at C1C2. Statistical analysis showed a good correlation (r=0.92, P<0.001) and accord (mean difference=6.6 ms) between the two methods. CONCLUSION: The new method to measure interatrial conduction time is consistent with the electrophysiological method; it could be particularly useful in programming the best AV delay in sequential and biventricular pacing, to avoid atrial contraction against a closed mitral valve.


Assuntos
Função Atrial , Ecocardiografia Doppler , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Ital Heart J ; 2(6): 468-71, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11453585

RESUMO

The present case report describes the diagnosis of a concealed bypass tract in the right lateral wall revealed by electrophysiologic evaluation performed in a patient with rare palpitations. A iatrogenic right bundle branch block (RBBB) caused the occurrence of an incessant atrioventricular reentrant tachycardia. The disappearance of the RBBB determined a very difficult induction of the tachycardia that, when induced, showed a shorter cycle length and ventriculoatrial interval than those observed during RBBB tachycardia. The presence of a RBBB ipsilateral to the right free wall accessory pathway provided a critical delay within the circuit thus allowing the bypass tract to recover excitability. This relevant delay also allows the sinus beat to initiate and stabilize the tachycardia thus rendering it incessant.


Assuntos
Bloqueio de Ramo/complicações , Doença Iatrogênica , Taquicardia por Reentrada no Nó Atrioventricular/etiologia , Adulto , Humanos , Masculino
5.
J Cardiovasc Electrophysiol ; 12(5): 529-35, 2001 May.
Artigo em Inglês | MEDLINE | ID: mdl-11386512

RESUMO

INTRODUCTION: The site of origin of idiopathic ventricular tachycardia (VT) arising from the left ventricular outflow tract (LVOT) may be closely related to the aortic valve leaflets, and radiofrequency (RF) delivery potentially can damage them. Intracardiac echocardiography (ICE) can identify accurately the ablation electrode and anatomic landmarks, and contact with the endocardium can be easily assessed. The aim of this study was to define the utility and the accuracy of ICE in guiding RF ablation of idiopathic VT of the LVOT. METHODS AND RESULTS: Five consecutive patients (all men; mean age 20.4 years, range 16 to 25) symptomatic for idiopathic VT underwent RF ablation. A 9-French, in-sheath catheter with a 9-MHz ultrasound transducer was inserted through the femoral vein and positioned in the His-bundle region or right ventricular outflow tract to provide a clear view of the aortic root. Local earliest ventricular activation during tachycardia and pace mapping were used to identify the ablation site. Idiopathic VT was ablated successfully in all patients using a median of two RF pulses, delivered during tachycardia. High-resolution images of the aortic valve and ablation electrode were achievable in all cases. Direct vision of ablation electrode-endocardial contact in the outflow tract was assessed easily in all patients. CONCLUSION: Idiopathic VT of the LVOT can be treated successfully with RF ablation. ICE can accurately guide catheter ablation and identify anatomic landmarks, endocardial contact, and ablation electrode movement.


Assuntos
Ablação por Cateter , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Taquicardia Ventricular/patologia , Taquicardia Ventricular/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Procedimentos Cirúrgicos Cardíacos/instrumentação , Ecocardiografia/estatística & dados numéricos , Eletrocardiografia , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Taquicardia Ventricular/diagnóstico por imagem , Ultrassonografia de Intervenção , Obstrução do Fluxo Ventricular Externo/diagnóstico por imagem
7.
Ann Ist Super Sanita ; 37(3): 435-41, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11889961

RESUMO

The use of monophasic action potential (MAP) recordings has been of important value during atrial fibrillation to understand the possibility of local pacing capture during the arrhythmia, while MAP and refractoriness determination after sinus rhythm restoration have highlighted the issue of electrophysiological remodeling owing to rate. Moreover the contemporary recording of MAP and refractoriness at the same atrial sites permitted to better understand the behavior of the ERP/MAP ratio in these patients. Local atrial pacing capture has been demonstrated in humans with chronic atrial fibrillation and suggests the presence of re-entrant circuits with large excitable gaps. The studies about atrial remodeling have shown a shortening of atrial ERP or monophasic action potential duration after cardioversion of persistent AF, while discordant results have been observed for what it concerns refractoriness adaptation to rate. Finally, the recording of a mean ERP/MAP90 ratio < 1 at all the pacing cycle lengths, indicates that no post-repolarization refractoriness was present after cardioversion of persistent atrial fibrillation.


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrofisiologia , Humanos
8.
J Am Coll Cardiol ; 36(7): 2234-41, 2000 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11127466

RESUMO

OBJECTIVES: The aim of our study was to verify the effect of oral administration of verapamil on atrial electrophysiologic characteristics after cardioversion of persistent atrial fibrillation (AF) in humans. BACKGROUND: Discordant findings have been reported regarding the efficacy of verapamil in preventing the electrical remodeling induced by AF. METHODS: We determined the effective refractory periods (ERPs) at five pacing cycle lengths (300 to 700 ms) and in five right atrial sites after internal cardioversion of persistent AF (mean duration 238.1+/-305.9 days) in 19 patients. Nine patients received oral verapamil (240 mg/day) starting four weeks before the electrophysiologic study, whereas the other 10 patients were in pharmacologic washout. RESULTS: The mean ERPs were 202.0+/-22.7 ms in the washout group and 189.3+/-18.5 ms in the verapamil group (p < 0.0001). The degree of adaptation of refractoriness to rate was similar in the two groups (mean slope value in the washout group and verapamil group: 0.07+/-0.03 and 0.08+/-0.05, respectively), showing a normal or nearly normal adaptation to rate in the majority of the paced sites in both groups. The mean ERP was slightly longer in the septum than in the lateral wall and in the roof, both in the washout and verapamil groups. CONCLUSIONS: In patients with persistent AF, long-term administration of verapamil before internal cardioversion resulted in 1) shortening of atrial ERPs; 2) no change in refractoriness dispersion within the right atrium; and 3) no change in atrial ERP adaptation to rate.


Assuntos
Antiarrítmicos/farmacologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Cardioversão Elétrica , Átrios do Coração/efeitos dos fármacos , Sistema de Condução Cardíaco/efeitos dos fármacos , Verapamil/farmacologia , Administração Oral , Idoso , Antiarrítmicos/administração & dosagem , Função Atrial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Verapamil/administração & dosagem
9.
Ital Heart J ; 1(8): 521-31, 2000 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10994932

RESUMO

In the last few years many studies have been performed to better understand the pathophysiological nature of atrial fibrillation (AF). These recent observations provide new insights into the initiation and perpetuation of AF, underlying the importance of the pulmonary veins as major sources of atrial triggers and introducing new concepts such as atrial electrical remodeling and spatial heterogeneity of the electrophysiologic characteristics of this arrhythmia. The purpose of this review was to provide current knowledge about AF electrophysiology in an effort to unite old models and new concepts.


Assuntos
Fibrilação Atrial/fisiopatologia , Técnicas Eletrofisiológicas Cardíacas , Sistema de Condução Cardíaco/fisiopatologia , Animais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/patologia , Sistema Nervoso Autônomo/fisiopatologia , Humanos
10.
Eur Heart J ; 21(10): 848-55, 2000 May.
Artigo em Inglês | MEDLINE | ID: mdl-10781357

RESUMO

BACKGROUND: Low energy internal cardioversion is a safe and effective procedure to restore sinus rhythm in patients with atrial fibrillation refractory to external cardioversion. However the procedure is invasive and fluoroscopy is mandatory. Aim of the study To assess the efficacy, safety and tolerability of a new simplified procedure of low energy internal cardioversion. METHODS: Twenty-five consecutive patients (19 males and 6 females) with persistent atrial fibrillation were submitted to low energy internal cardioversion using a step-up protocol (in steps of 50 V, starting from 300 V). A large surface area lead (cathode) was positioned in the oesophagus, 45 cm from the nasal orifice. A second large surface area lead (anode) was positioned in the right atrium. A quadripolar lead was positioned at the right ventricular apex to achieve ventricular synchronization and back-up pacing. Oesophageal endoscopy was performed within 24 h of the end of the procedure and repeated after 48 h, if injury to the oesophageal mucosa had occurred. RESULTS: Sinus rhythm was restored in 23 patients (92%) with a mean delivered energy of 15.74 J (range 5-27) and a mean impedance of 48 Omega. In two patients, endoscopy revealed that small burns had occurred in the oesophageal mucosa. Such lesions spontaneously healed after 48 h. CONCLUSIONS: This new technique of performing low energy internal cardioversion is effective and safe and avoids the positioning of a lead in the coronary sinus or in the left pulmonary artery, thereby simplifying the procedure.


Assuntos
Fibrilação Atrial/terapia , Ecocardiografia Transesofagiana , Cardioversão Elétrica/métodos , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
11.
J Interv Card Electrophysiol ; 4 Suppl 1: 65-8, 2000 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-10590491

RESUMO

At least 50% of patients who received an ICD have been treated with antiarrhythmic drugs (AAD). The potential indications for combining antiarrhythmic drugs and ICD are generally the following: reduction of the number of episodes of ventricular tachycardia or ventricular fibrillation and therefore of the number of shocks, improving patient's quality of life and extending the battery life of the ICD, prevention of supraventricular arrhythmias and/or control of their rate, lengthening of the tachycardia cycle length to allow ventricular tachycardia conversion by antitachycardia pacing and reduction of the number of episodes of syncope. Although previous papers reported conflicting results about pharmacologic therapy in reducing the frequency of iCD shocks, some recent randomized prospective studies showed the efficacy of pharmacologic therapy in reducing the frequency of ICD shocks. The use of antiarrhythmic drugs can have also adverse effect: an increase in the defibrillation threshold, an increase in the pacing threshold and an increase in the VT cycle length leading to detection failure. We have also to consider that some advantages derived from antiarrhythmic drugs can be reached by the new devices with atrial sensing and pacing and/or the possibility of atrial defibrillation or by using catheter ablation as adjunctive therapy to ICD. For these reasons, the concomitant use of antiarrhythmic drugs and ICD should be evaluated in each patient in relation to specific clinical and electrophysiologic features including: the frequency, the rate and the clinical presentation of the ventricular arrhythmia, the effect of the selected drug on the defibrillation threshold, the defibrillation threshold at the implant, the effect of the selected drug on the ventricular function and the likelihood of proarrhythmic events.


Assuntos
Antiarrítmicos/administração & dosagem , Desfibriladores Implantáveis , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Ensaios Clínicos como Assunto , Terapia Combinada , Feminino , Humanos , Masculino , Prognóstico , Análise de Sobrevida , Taquicardia Ventricular/mortalidade , Resultado do Tratamento , Fibrilação Ventricular/mortalidade
12.
J Interv Card Electrophysiol ; 3(1): 45-51, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10354975

RESUMO

BACKGROUND: Discomfort related to low-energy internal cardioversion (LEIC) represents a real problem in patients (pts) with atrial fibrillation (AF). The aim of our study was to verify if a single shock could restore sinus rhythm (SR) with a lower discomfort for the pt. METHODS: Thirty pts with chronic AF were randomized to receive a single 350 V shock (15 pts) or multiple shocks of increasing energy (15 pts). Three leads were positioned, respectively, in the coronary sinus and in the lateral right wall for shock delivery, and in the right ventricular apex for R wave synchronization. Truncated, biphasic shocks were used. In the first group a single 350 V shock was directly delivered and a second 400 V shock was given only if SR has not been restored. In the second group, beginning at 50 volts the voltage was increased in steps of 50 volts until SR restoration. No patient was sedated. After each shock the pts were asked to rate their discomfort on a scale of 1 to 5 (1 = not perceived, 5 = severe discomfort). RESULTS: SR was restored in all the subjects. In group 1 SR was obtained in 12/15 (80%) pts with the first 350 V (8.1 +/- 0.8 joules) shock, while the remaining 3 patients required the second 400 V (10.2 +/- 0.3 joules) shock. In group 2 the mean atrial defibrillation threshold was 346.7 +/- 1029.7 volts (8.0 +/- 101.5 joules). Then discomfort score was 2.5 +/- 0.6 in group 1 and 3.3 +/- 10.6 in group 2 (p < 0.01). CONCLUSIONS: A single shock of 350 V restores SR in the majority of pts with chronic AF; by use this new approach, LEIC is tolerated better than the multiple shocks step-up protocol.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Doença Crônica , Estimulação Elétrica , Feminino , Frequência Cardíaca , Humanos , Masculino , Concentração Máxima Permitida , Pessoa de Meia-Idade , Resultado do Tratamento
13.
G Ital Cardiol ; 29(2): 107-14, 1999 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-10088065

RESUMO

OBJECTIVES: The aims of our study were to define the spatial extension of local atrial pacing capture (LAPC) in the right lateral atrial wall and to verify the effects of antiarrhythmic drugs on capture extension. BACKGROUND: Recently, LAPC during spontaneous chronic atrial fibrillation (AF) has been demonstrated directly in humans, but no systematic attempt has been made to evaluate its spatial extension. METHODS: The study was conducted in 14 consecutive patients with chronic AF, nine of whom were taking antiarrhythmic drugs. A Franz catheter for pacing and monophasic action potential recording was positioned in the lateral right atrial wall. An octopolar recording lead was positioned about 10 mm apart. The presence of atrial capture and its extension (number of captured bipolar pairs) were evaluated during decremental pacing. RESULTS: Forty-eight atrial capture attempts were made. LAPC was achieved in all the performed attempts. The AF types immediately before capture were type 1 in 35 (73%) and type 2 in 13 (27%) episodes. In 32 episodes, the capture was lost within 15 seconds and in the remaining 16 pacing was stopped after 15 seconds of stable capture. In 26 episodes, capture extended radially up to 4 cm from the pacing site, in 18 up to 3 cm, in 3 up 1 cm and in 1 up 1 cm. The mean extension in patients being treated with antiarrhythmic drugs was significantly greater than what was seen in untreated patients (3.8 +/- 0.4 vs 2.9 +/- 0.7 cm, p < 0.00001). Capture loss was less frequently observed when all four of the bipolar recording sites had been captured (13/25, 52% vs 19/23, 82%, respectively, p = 0.05). CONCLUSIONS: LAPC in the lateral right atrial wall extends over a radius of 30-40 mm in the majority of capture episodes and is greater in patients treated with antiarrhythmic drugs. Our results suggest that, at least theoretically, simultaneous multisite pacing could be used to terminate AF. Moreover, a reduction in the atrial defibrillation threshold could be expected performing low-energy internal cardioversion during LPC.


Assuntos
Fibrilação Atrial/fisiopatologia , Estimulação Cardíaca Artificial , Idoso , Análise de Variância , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Estimulação Cardíaca Artificial/métodos , Estimulação Cardíaca Artificial/estatística & dados numéricos , Distribuição de Qui-Quadrado , Doença Crônica , Eletrocardiografia/efeitos dos fármacos , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Eletrocardiografia/estatística & dados numéricos , Eletrodos , Eletrofisiologia , Feminino , Átrios do Coração/efeitos dos fármacos , Átrios do Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade
14.
Circulation ; 98(25): 2860-5, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-9860788

RESUMO

BACKGROUND: In animal models, induced atrial fibrillation shortens the atrial effective refractory period (ERP) and reverses its physiological adaptation to rate. It is not clear whether this process, known as "electrical remodeling," occurs in humans. METHODS AND RESULTS: We determined the ERPs, at 5 pacing cycle lengths (300 to 700 ms) and in 5 right atrial sites, after internal cardioversion of chronic atrial fibrillation in 25 patients (14 in pharmacological washout and 11 on amiodarone). The ERPs were 195.5+/-18.8 ms in the washout and 206.3+/-17.9 ms in the amiodarone patients (P<0.0001). ERPs were closely correlated with the stimulation rates (r=0.95 in the washout and r=0.94 in the amiodarone group), and slope values indicating a normal (>/=0.07) or nearly normal (0.05 to 0.06) adaptation of ERP to rate were found in 77% of the 84 paced sites. The mean ERP was shorter in the lateral wall (198.1+/-17.9 ms) than in the atrial roof (203.3+/-21.5 ms) and in the septum (210.5+/-20.0 ms) (P<0.03). After 4 weeks of sinus rhythm, the mean ERP, determined again in 8 patients (4 in wash-out and 4 on amiodarone), was significantly increased compared with the basal study (221. 4+/-21.4 versus 197.8+/-18.3 ms, P<0.0001). CONCLUSIONS: After cardioversion of chronic atrial fibrillation, (1) atrial ERP adaptation to rate was normal or nearly normal in the majority of the cases, (2) a significant dispersion of refractoriness between different right atrial sites was present, and (3) ERPs were significantly increased after 4 weeks of sinus rhythm in both washout and amiodarone patients.


Assuntos
Fibrilação Atrial/fisiopatologia , Função do Átrio Direito/fisiologia , Cardioversão Elétrica , Adaptação Fisiológica , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Estimulação Cardíaca Artificial , Doença Crônica , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade
15.
Pacing Clin Electrophysiol ; 21(11 Pt 2): 2178-81, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9825314

RESUMO

BACKGROUND: The effectiveness of cardiac pacing in preventing vasovagal syncope remains controversial. However, DDI pacing with rate hysteresis has been reported to prevent the recurrence of cardioinhibitory vasovagal syncope in up to 35% of affected subjects and to reduce the overall incidence of syncopal episodes in the others. Recently, DDD pacing with a new promising rate drop response function (Medtronic Thera-I model 7960) has become available in clinical practice. AIM OF THE STUDY: The aim of the present open trial was to test the effectiveness of this new pacing modality in patients with cardioinhibitory vasovagal syncope. STUDY POPULATION AND METHODS: The study population included 20 patients (12 males and 8 females; mean age 61.1 +/- 14 yrs) with recurrent syncope (mean number of prior episode = 6.8, range 5-11) and cardioinhibitory responses during two head-up tilt tests: the first diagnostic and the second during drug therapy with either beta-blockade or etilephrine. The study patients were randomized to receive either DDI pacing with rate hysteresis (8 patients) or DDD pacing with rate drop response function (11 patients). The head-up tilt test performed 1 month after pacemaker implantation was positive in 3 of 12 patients (25%) with DDD pacing with rate drop response function and in 5 of 8 patients (62.5%) with DDI pacing with rate hysteresis. The mean duration of follow-up was 17.7 +/- 7.4 months. During follow-up no patients with a DDD pacemaker with rate drop response function had syncope, while 3 of 8 patients with a DDI pacemaker with rate hysteresis had recurrence of syncope (P < 0.05). CONCLUSIONS: These data suggest that DDD pacing with rate drop response function is effective in cardioinhibitory vasovagal syncope and may be preferable to DDI pacing with rate hysteresis.


Assuntos
Estimulação Cardíaca Artificial/métodos , Marca-Passo Artificial , Síncope Vasovagal/prevenção & controle , Feminino , Seguimentos , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Síncope Vasovagal/diagnóstico , Teste da Mesa Inclinada , Fatores de Tempo
16.
Pacing Clin Electrophysiol ; 21(11 Pt 2): 2420-5, 1998 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9825360

RESUMO

Electroencephalographic (EEG) monitoring was performed during head-up tilt testing (HUT) in a group of 63 consecutive patients (27 males, 36 females, mean age 41.5 years) with a history of recurrent syncope of unknown origin despite extensive clinical and laboratory evaluation. Syncope occurred in 27/63 patients (42.8%) during HUT and was cardioinhibitory in 11/27 (40.7%) and vasodepressor in 16/27 (59.3%). All patients with a negative response to HUT had no significant EEG modifications. In patients with vasodepressor syncope a generalized high amplitude 4-5 Hz (theta range) slowing of EEG activity appeared at the onset of syncope, followed by an increase in brain wave amplitude with a reduction of frequency at 1.5-3 Hz (delta range). The return to the supine position was associated with brain wave amplitude reduction and frequency increase to 4-5 Hz, followed by restoration of a normal EEG pattern and arousal (mean total duration of syncope 23.2 s). In patients with cardioinhibitory syncope, a generalized high amplitude EEG slowing in the theta range was noted at the onset of syncope, followed by a brain wave amplitude increase and slowing in the delta range. A sudden reduction of brain wave amplitude ensued leading to the disappearance of electroencephalographic activity ("flat" EEG). The return to the supine position was not followed by immediate resolution of EEG abnormalities or consciousness recovery, both occurring after a longer time interval (mean total duration of syncope 41.4 s). EEG monitoring during HUT allowed the recording and systematic description of electroencephalographic abnormalities developing in the course of tilt induced vasovagal syncope.


Assuntos
Encéfalo/fisiopatologia , Eletroencefalografia , Síncope Vasovagal/fisiopatologia , Adulto , Pressão Sanguínea , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Decúbito Dorsal/fisiologia , Síncope Vasovagal/diagnóstico , Teste da Mesa Inclinada
17.
G Ital Cardiol ; 28(7): 788-96, 1998 Jul.
Artigo em Italiano | MEDLINE | ID: mdl-9773304

RESUMO

BACKGROUND: The purpose of our study was to evaluate the efficacy and safety of intracavitary cardioversion (IC) with either high (HEIC) or low (LEIC) energy in patients with chronic atrial fibrillation (AF) refractory to external cardioversion. METHODS: Forty patients underwent IC with either high (30 pts) or low energy (10 pts); HEIC was performed by delivering one or more shocks between one electrode of the lead positioned in the right atrium and a back plate. The following energy values were used in sequence: 100, 200, 300 joules. In LEIC shocks were delivered between two custom-made decapolar leads (one in the coronary sinus and another one in the right lateral atrial wall) beginning from 50 Volts and increasing the voltage by steps of 50 Volts. Another catheter in the right ventricular apex was used for ventricular synchronization. RESULTS: Sinus rhythm was restored in 24/30 (80%) patients undergoing HEIC and in 10/10 (100%) patients undergoing LEIC. No serious or permanent complications occurred. CONCLUSIONS: HEIC and LEIC are effective in patients with AF refractory to external cardioversion. Both the procedures seem to be safe.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Adulto , Idoso , Análise de Variância , Antiarrítmicos/administração & dosagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Doença Crônica , Terapia Combinada , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/estatística & dados numéricos , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
18.
J Cardiovasc Electrophysiol ; 9(8 Suppl): S170-6, 1998 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-9727694

RESUMO

Low-energy intra-atrial defibrillation is a new therapeutic option for restoring sinus rhythm in patients with atrial fibrillation (AF). The success rate is quite high when right atrium-coronary sinus or right atrium-pulmonary artery electrode configurations are used, although the former is associated with a slightly lower defibrillation threshold. Several issues regarding the safety and tolerability of the procedure remain unresolved. Our experience and that of others indicate that low-energy intra-atrial cardioversion is safe even during exercise, provided the shock is well synchronized with the QRS and the preshock RR interval is > 500 msec. Reported defibrillation thresholds in patients with persistent AF range from 4 to 8 J, and shocks of this type inevitably are associated with some degree of discomfort. Measures aimed at lowering the defibrillation threshold (e.g., use of biphasic waveforms, antiarrhythmic pretreatment, and use of a single effective shock, as opposed to the multiple shocks delivered in research settings) can be expected to increase patient tolerance and extend the indications for low-energy intra-atrial cardioversion. The procedure currently is indicated for patients with persistent AF who are resistant to external defibrillation unable or unwilling to undergo general anesthesia. The procedure could be expanded to patients affected by obesity in whom the efficacy of external cardioversion is lower.


Assuntos
Fibrilação Atrial/terapia , Cardioversão Elétrica/métodos , Fibrilação Atrial/fisiopatologia , Cardioversão Elétrica/efeitos adversos , Átrios do Coração/fisiopatologia , Humanos
19.
Am Heart J ; 135(4): 671-6, 1998 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-9539484

RESUMO

BACKGROUND: Head-up tilt testing is widely used in the clinical assessment of patients with unexplained syncope. However, the lack of a standard methodology and the conflicting results concerning sensitivity and specificity of the procedure have prompted further studies to define a more cost-effective approach for tilt testing. OBJECTIVES: Our clinical investigation was undertaken to assess the diagnostic value in unexplained syncope of a simple and time-saving protocol for head-up tilt testing, including low-dose sublingual isosorbide dinitrate administration. PATIENTS AND METHODS: A group of 73 consecutive patients (43 women and 30 men, mean age 39.6+/-21.8 years) with unexplained syncope despite conventional clinical cardiovascular and neurologic assessment and 10 asymptomatic control subjects underwent head-up tilt testing with isosorbide dinitrate challenge. Participants were tilted at 60 degrees for 30 minutes without medication; if no symptoms occurred, 1.25 mg of isosorbide dinitrate was administered sublingually and tilting was continued for an additional 15 minutes. RESULTS: During the drug-free phase of the test 14 (19.2%) patients had syncope. After isosorbide dinitrate administration syncope occurred in another 28 patients (38.3%); minor symptoms in association with hypotension developed in 10 (13.7%) patients. The test result was negative in all control subjects. The positive rate and specificity of head-up tilt testing with isosorbide dinitrate provocation were 57.5% and 100%, respectively. CONCLUSIONS: This new practical diagnostic procedure was found to be fairly sensitive and clearly specific in inducing a vasovagal reflex in patients with syncope of uncertain origin. Consequently, such approach could give a significant contribution in the diagnostic workup of these patients.


Assuntos
Dinitrato de Isossorbida/administração & dosagem , Postura , Síncope/diagnóstico , Vasodilatadores/administração & dosagem , Administração Sublingual , Adulto , Pressão Sanguínea/efeitos dos fármacos , Bradicardia/induzido quimicamente , Bradicardia/fisiopatologia , Diagnóstico Diferencial , Relação Dose-Resposta a Droga , Ecocardiografia Doppler , Eletrocardiografia Ambulatorial , Eletroencefalografia , Feminino , Seguimentos , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipotensão/induzido quimicamente , Hipotensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Síncope/etiologia , Síncope/fisiopatologia , Fatores de Tempo
20.
Pacing Clin Electrophysiol ; 21(12): 2641-50, 1998 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-9894655

RESUMO

The aims of the study were to verify the efficacy and safety of low energy internal cardioversion (LEIC) in patients with persistent atrial fibrillation (AF) and to identify the factors affecting the atrial defibrillation threshold (ADT). Forty-nine patients with persistent (lasting > or = 10 days) AF underwent LEIC. In each patient, two 6 Fr custom-made catheters with large active surface areas were positioned in the coronary sinus (cathode) and the lateral right wall (anode), respectively, for shock delivery, and a tetrapolar lead was placed in the right ventricular apex for R wave synchronization. Truncated, biphasic (3 ms + 3 ms), exponential shocks were used, beginning at 50 V and increasing in steps of 50 V until sinus rhythm had been restored. Mild sedation (diazepam 5 mg i.v.) was administered to 12 patients. Sinus rhythm was restored in all the subjects with mean voltage and energy levels of 352.0 +/- 80.3 V and 8.2 +/- 3.4 J, respectively. The ADT in patients pretreated with amiodarone (6.4 +/- 1.8 J) was lower than that of patients who had not received any antiarrhythmic drugs (9.2 +/- 3.7) (P = 0.04). No ventricular arrhythmias were induced by any of the atrial shocks, and no other complications were observed. During a mean follow-up of 162.9 +/- 58.7 days, AF recurred in 21 (43%) patients; 71% of these occurred in the first week after cardioversion. LEIC is effective in restoring sinus rhythm in patients with persistent AF. The technique seems to be safe and does not require general anesthesia or, in most cases, sedation. Patients pretreated with amiodarone have lower ADTs.


Assuntos
Fibrilação Atrial/terapia , Cateterismo Cardíaco , Cardioversão Elétrica , Adulto , Idoso , Idoso de 80 Anos ou mais , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Ecocardiografia Transesofagiana , Eletrocardiografia , Feminino , Testes de Função Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Propafenona/uso terapêutico , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA