1.
Transl Vis Sci Technol ; 10(10): 14, 2021 08 12.
Artigo em Inglês | MEDLINE | ID: mdl-34705041

RESUMO

Purpose: To report on the safety and efficacy of the 256-channel Intelligent Micro Implant Eye epiretinal prosthesis system (IMIE 256). Methods: The IMIE 256 implants were implanted in the right eyes of five subjects with end-stage retinitis pigmentosa. Following implantation, the subjects underwent visual rehabilitation training for 90 days, and their visual performance was evaluated using the grating visual acuity test, Tumbling E visual acuity test, direction of motion, square localization, and orientation and mobility test. To evaluate the safety of the IMIE 256, all adverse events were recorded. Results: Subjects performed significantly better on all evaluations with the IMIE 256 system on as compared with the performance at baseline or with the system off. There was a steady improvement in performance at each observation interval, indicating that the training and/or practice helped the subjects use the IMIE 256. There were two serious adverse events-electrode array movement and low intraocular pressure in one subject, which resolved with surgery. There were no other adverse events observed except those expected in the course of postoperative healing. Conclusions: These results show an improved safety and efficacy profile compared with that of the Argus II implant. Further clinical trials are needed to confirm these results in a larger number of subjects and over longer durations. Translational Relevance: To our knowledge, this study reports the first in-human data from a high-density (256 electrodes) epiretinal implant to restore sight to a subset of blind patients.


Assuntos
Retinose Pigmentar , Próteses Visuais , Eletrodos Implantados , Humanos , Retina , Acuidade Visual
2.
Conf Proc IEEE Eng Med Biol Soc ; 2005: 7114-7, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-17281915

RESUMO

This work presents a new multi-site probe array applied with parylene technology, used for neural prostheses to record high-level cognitive neural signals. Instead of inorganic materials (e.g. silicon dioxide, silicon nitride), the electrodes and conduction traces on probes are insulated by parylene, which is a polymer material with high electrical resistivity, mechanical flexibility, biocompatibility and easy deposition process. As a result, the probes exhibit better electrical and mechanical properties. The all dry process is demonstrated to fabricate these probe arrays with monolithically integrated parylene flexible cables using double-side-polished (DSP) wafers. With the parylene flexible cables, the probes can be easily assembled to a high density 3-D array for chronic implantation.

SELEÇÃO DE REFERÊNCIAS