Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Biochem ; 312(2): 208-16, 2003 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-12531207

RESUMO

Yessotoxin (YTX) treatment of MCF-7 cells results in the accumulation of a 100-kDa fragment of E-cadherin (ECRA(100)) without a parallel loss of the intact protein in cytosoluble extracts. As a consequence, concentration-dependent increases in the total immunoreactivity detectable by anti-E-cadherin antibodies relative to controls (RTI) and in the relative immunoreactivity of ECRA(100) (RI) are observed. These responses have been exploited to develop a functional assay to measure YTX in samples from contaminated mussels by a three-step procedure, consisting of (i) treatment of MCF-7 cells with YTX standard in the concentration range 0-1nM and of unknown samples; (ii) preparation of cellular extracts, fractionation of proteins by polyacrylamide gel electrophoresis under denaturing conditions, and immunoblotting with anti-E-cadherin antibodies, followed by densitometric analyses of autoradiographies and calculation of RI of ECRA(100) and of RTI of the samples; and (iii) interpolation of the YTX concentrations in unknown samples on standard curves, by the RI of ECRA(100) and the RTI of the samples. The procedure has been used to measure yessotoxins in contaminated mussel samples, and the results obtained show that this functional assay is very sensitive (limit of detection of about 100ng equivalent YTX/g of digestive gland), and robust, as (i) it is insensitive to matrix effects in the range of toxin concentrations relevant for risk assessment to protect humans from exposure to YTX, (ii) calculations are based on a molecular parameter (the RI of ECRA(100)) which is not affected by errors in sample preparation, (iii) it can be performed by the use of antibodies commercially available from different companies, and (iv) it does not show an absolute need of calibration by a pure standard within each assay.


Assuntos
Bivalves/química , Éteres Cíclicos/análise , Contaminação de Alimentos , Oxocinas/análise , Animais , Anticorpos/imunologia , Bivalves/anatomia & histologia , Caderinas/análise , Caderinas/metabolismo , Técnicas de Cultura de Células , Sobrevivência Celular , Cromatografia Líquida de Alta Pressão , Sistema Digestório/química , Eletroforese em Gel de Poliacrilamida , Éteres Cíclicos/imunologia , Éteres Cíclicos/farmacologia , Venenos de Moluscos , Oxocinas/imunologia , Oxocinas/farmacologia , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA