Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Glob Cardiol Sci Pract ; 2024(4): e202439, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-39351475

RESUMO

Introduction: There are worldwide reports that hospital admissions for acute coronary syndrome (ACS) have declined during the COVID-19 pandemic. Chios is a Greek island with only one confirmed coronavirus case during the lockdown. This study aimed to compare admissions for ACS in Chios General Hospital, Greece, between the COVID-19 lockdown period and the same period in the previous year. Methods: Retrospective record analysis of an isolated insular population referring to the only district hospital on the island. ACS incidence, type, and complications were recorded and compared between 26/02/2020-04/05/2020 and between 26/02/2019-04/05/2019. Results: ACS hospital admissions in 2020 were 1.72/10,000 inhabitants vs. 1.03/10,000 inhabitants in 2019 (p = 0.317). No differences in ACS type, duration from symptom onset to first medical contact, hemodynamic status, left ventricular function at discharge, or complications were recorded. Conclusion: The incidence of ACS did not decrease and the prognosis was not worse during the COVID-19 pandemic in a strictly isolated Greek insular population not overwhelmed by coronavirus cases.

2.
J Med Case Rep ; 18(1): 263, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38807243

RESUMO

BACKGROUND: Pneumomediastinum and pneumorrachis are rare complications following epidural analgesia, that can either be asymptomatic or rarely can produce mild to moderate severity symptoms. Most reported cases regarding the presentation of these two entities with epidural analgesia concern asymptomatic patients, however there are cases reporting post-dural puncture headache and respiratory manifestations. CASE PRESENTATION: We present a case where a combined lumbar epidural and spinal anesthesia was performed using the loss of resistance to air technique (LOR), on a 78-year-old Greek (Caucasian) male undergoing a total hip replacement. Despite being hemodynamically stable throughout the operation, two hours following epidural analgesia the patient manifested a sudden drop in blood pressure and heart rate that required the administration of adrenaline to counter. Pneumomediastinum, pneumorrachis and paravertebral soft tissue emphysema were demonstrated in a Computed Tomography scan. We believe that injected air from the epidural space and surrounding tissues slowly moved towards the mediastinum, stimulating the para-aortic ganglia causing parasympathetic stimulation and therefore hypotension and bradycardia. CONCLUSION: Anesthesiologists should be aware that epidural analgesia using the LOR to technique injecting air could produce a pneumomediastinum and pneumorrachis, which in turn could produce hemodynamic instability via parasympathetic stimulation.


Assuntos
Analgesia Epidural , Artroplastia de Quadril , Enfisema Mediastínico , Pneumorraque , Humanos , Masculino , Enfisema Mediastínico/etiologia , Enfisema Mediastínico/diagnóstico por imagem , Idoso , Analgesia Epidural/efeitos adversos , Pneumorraque/etiologia , Pneumorraque/diagnóstico por imagem , Artroplastia de Quadril/efeitos adversos , Hemodinâmica , Tomografia Computadorizada por Raios X , Raquianestesia/efeitos adversos
4.
Hellenic J Cardiol ; 2023 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-37634870

RESUMO

INTRODUCTION: Chios Mastiha essential oil (CMO) is a natural product extracted from the resin of Mastiha, possessing antioxidant, anti-microbial, anti-ulcer, anti-neoplastic, and cholesterol-lowering capabilities in vitro, and its hypolipidemic effect was confirmed in animal studies. Yet, there are no randomized, placebo-controlled clinical studies in the literature regarding CMO's hypolipidemic effects in humans. A prospective, randomized, placebo-controlled study was designed to study the hypolipidemic effect of CMO capsules on healthy volunteers with elevated cholesterol. METHODS: 192 healthy volunteers were screened and 160 of them with total cholesterol> 200 mg/dl participated in the study. They were randomized with a 2:1 ratio of receiving CMO capsules (200 mg mastiha-oil/capsule) and placebo for 8 weeks respectively. 113 patients received CMO and 47 were randomized in the control group, and all of them completed the follow-up period. RESULTS: After 8 weeks of CMO administration, total and LDL cholesterol were significantly lower in the CMO compared to the placebo group 215.2 ± 27.5 vs 237.0 ± 27.9 mg/dl (p < 0.001) and 135.0 ± 26.1 vs 153.0 ± 23.3 mg/dl (p < 0.001) respectively. No gastrointestinal adverse events or liver or renal toxicity were reported. Additionally, in the CMO group total cholesterol was significantly decreased by 20.6 mg/dl (9%), LDL by 18.1 mg/dl (12%), triglycerides by 21.8 mg/dl (15%), and glucose by 4.6 mg/dl (5%) and HDL was increased by 2.4 mg/dl (5%), compared to their baseline values. CONCLUSION: The MASTIHA-OIL study showed the efficacy and safety of CMO in reduction of total and LDL cholesterol after 8 weeks of administration in healthy volunteers with elevated cholesterol levels.

11.
Int J Bioprint ; 5(1): 173, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32782980

RESUMO

The field of three-dimensional (3D) bioprinting is rapidly emerging as an additive manufacturing method for tissue and organ fabrication. The demand for tissues and organ transplants is ever increasing, although donors are not as readily available. Consequently, tissue engineering is gaining much attention to alleviate this problem. The process of achieving well-structured 3D bioprinted constructs using hydrogel bioinks depends on symmetrical precision, regulated flow rates, and viability of cells. Even with the mentioned parameters optimized, the printed structures need additional refining by removing excessive liquids, as peptide hydrogel bioprints encapsulate water. However, it is challenging to eliminate the confined fluids without compromising the printing process. In this paper, we introduced a vacuum system to our 3D bioprinting robotic arm and thus optimized the printing quality for complex and refined 3D scaffolds. Moreover, the proposed vacuum system supports printing with cells. Our results show improved printing resolution which facilitates the printing of higher and more stable structures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA