Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
HLA ; 93(6): 436-444, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30838802

RESUMO

The lymphocyte crossmatch is currently the only cell-based compatibility assay performed by histocompatibility laboratories for transplant purposes. While in many transplant programs the complement-dependent cytotoxicity crossmatch (CDCXM) remains in use, when available, the flow cytometry crossmatch (FCXM) is the method of choice because of its superior sensitivity and specificity. Unfortunately, the maintenance and cost of a flow cytometer is a considerable limitation for small histocompatibility laboratories. Therefore, in this study, we evaluated the use of the Cellometer Vision CBA image cytometer (Nexcelom Bioscience LLC, Lawrence, Massachusetts) as an alternative instrument to perform the crossmatch assay. The 3-color FCXM protocol was modified into two separate 2-color panel image cytometry crossmatches (IXMs), one for T cells and one for B cells. After initial serum and cell incubation, a cocktail consisting of PE/Cy5-conjugated anti-human CD3 or CD19 and PE-conjugated anti-human IgG F(ab')2 was added to the T cell and B cell panels, respectively. The final cell preparation was added to a separate counting chamber. Images were captured using the Cellometer Vision CBA, an image cytometer designed for cell counting, size analysis and fluorescence intensity measurement. Thirty-nine IXMs were performed and compared with the FCXM. We obtained a concordance sensitivity of 94.1% and 100% and specificity of 100% and 88.9% for T cells and B cells, respectively. The linearity of the system was verified using dilutions of a sample containing known donor-specific anti-HLA antibodies (DSA) against the target cells. This feasibility study demonstrates that the FCXM test could be easily adapted to the Cellometer Vision CBA image cytometer without compromising specificity and sensitivity. The low instrumentation cost, minimal maintenance, and simple operation allow for efficient implementation or transition from the FCXM to the IXM method.


Assuntos
Citometria de Fluxo/métodos , Teste de Histocompatibilidade/métodos , Citometria por Imagem/métodos , Alelos , Cor , Testes Imunológicos de Citotoxicidade/métodos , Antígenos HLA/imunologia , Humanos , Imunoglobulina G/química , Modelos Lineares , Linfócitos/citologia , Fenótipo , Valor Preditivo dos Testes , Sensibilidade e Especificidade
2.
J Fluoresc ; 24(4): 983-9, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24740550

RESUMO

In recent years, the lipoaspirate collected from adipose tissue has been seen as a valuable source of adipose-derived mesenchymal stem cells for autologous cellular therapy. For multiple applications, adipose-derived mesenchymal stem cells are isolated from the stromal vascular fraction (SVF) of adipose tissue. Because the fresh stromal vascular fraction typically contains a heterogeneous mixture of cells, determining cell concentration and viability is a crucial step in preparing fraction samples for downstream processing. Due to a large amount of cellular debris contained in the SVF sample, as well as counting irregularities standard manual counting can lead to inconsistent results. Advancements in imaging and optics technologies have significantly improved the image-based cytometric analysis method. In this work, we validated the use of fluorescence-based image cytometry for SVF concentration and viability measurement, by comparing to standard flow cytometry and manual hemocytometer. The concentration and viability of freshly collected canine SVF samples are analyzed, and the results highly correlated between all three methods, which validated the image cytometry method for canine SVF analysis, and potentially for SVF from other species.


Assuntos
Fluorescência , Citometria por Imagem/métodos , Células Estromais/citologia , Animais , Automação , Sobrevivência Celular , Cães
3.
J Vis Exp ; (76)2013 Jun 19.
Artigo em Inglês | MEDLINE | ID: mdl-23851941

RESUMO

Studies of the cellular pathogenesis mechanisms of pathogenic yeasts such as Candida albicans, Histoplasma capsulatum, and Cryptococcus neoformans commonly employ infection of mammalian hosts or host cells (i.e. macrophages) followed by yeast quantification using colony forming unit analysis or flow cytometry. While colony forming unit enumeration has been the most commonly used method in the field, this technique has disadvantages and limitations, including slow growth of some fungal species on solid media and low and/or variable plating efficiencies, which is of particular concern when comparing growth of wild-type and mutant strains. Flow cytometry can provide rapid quantitative information regarding yeast viability, however, adoption of flow cytometric detection for pathogenic yeasts has been limited for a number of practical reasons including its high cost and biosafety considerations. Here, we demonstrate an image-based cytometric methodology using the Cellometer Vision (Nexcelom Bioscience, LLC) for the quantification of viable pathogenic yeasts in co-culture with macrophages. Our studies focus on detection of two human fungal pathogens: Histoplasma capsulatum and Candida albicans. H. capsulatum colonizes alveolar macrophages by replicating within the macrophage phagosome, and here, we quantitatively assess the growth of H. capsulatum yeasts in RAW 264.7 macrophages using acridine orange/propidium iodide staining in combination with image cytometry. Our method faithfully recapitulates growth trends as measured by traditional colony forming unit enumeration, but with significantly increased sensitivity. Additionally, we directly assess infection of live macrophages with a GFP-expressing strain of C. albicans. Our methodology offers a rapid, accurate, and economical means for detection and quantification of important human fungal pathogens in association with host cells.


Assuntos
Candida albicans/isolamento & purificação , Histoplasma/isolamento & purificação , Citometria por Imagem/métodos , Micologia/métodos , Animais , Candida albicans/citologia , Candidíase/microbiologia , Contagem de Colônia Microbiana/métodos , Histoplasma/citologia , Histoplasmose/microbiologia , Humanos , Citometria por Imagem/instrumentação , Macrófagos/microbiologia , Camundongos , Micologia/instrumentação
4.
J Microbiol Methods ; 91(3): 468-76, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22985717

RESUMO

The objective of this study was to develop an image-based cytometric methodology for the quantification of viable pathogenic yeasts, which can offer increased sensitivity and efficiency when compared to the traditional colony forming unit (CFU) assay. Live/dead yeast quantification by flow cytometry has been previously demonstrated, however, adoption of flow cytometric detection of pathogenic yeasts has been limited for a number of practical reasons including its high cost and biosafety considerations. Our studies focus on detection of two human fungal pathogens: Histoplasma capsulatum and Candida albicans. H. capsulatum colonizes alveolar macrophages by replicating within the macrophage phagosome. Here, we quantitatively assess the growth of H. capsulatum yeasts within RAW 264.7 macrophages using acridine orange/propidium iodide staining in combination with Cellometer image-based cytometry; this method faithfully recapitulates growth trends as measured by traditional CFU enumeration, but with significantly increased sensitivity. Additionally, we directly assess infection of bone marrow-derived macrophages with a GFP-expressing strain of C. albicans. To demonstrate that image-based cytometry can be used as a tool to assess the susceptibility of fungi to antifungal drugs, we perform dose response experiments with the antifungal drugs amphotericin B and itraconazole and show that image-based cytometry allows rapid assessment of the kinetics of cytotoxicity induced by these antifungals. Our methodology offers a rapid, accurate, and economical means for detection and quantification of important human fungal pathogens, either alone or in association with host cells.


Assuntos
Candida albicans/crescimento & desenvolvimento , Candidíase/microbiologia , Contagem de Colônia Microbiana/métodos , Citometria de Fluxo/métodos , Histoplasma/crescimento & desenvolvimento , Histoplasmose/microbiologia , Citometria por Imagem/métodos , Animais , Antifúngicos/farmacologia , Candida albicans/citologia , Candida albicans/efeitos dos fármacos , Candida albicans/isolamento & purificação , Histoplasma/citologia , Histoplasma/efeitos dos fármacos , Histoplasma/isolamento & purificação , Humanos , Macrófagos Alveolares/microbiologia , Camundongos , Testes de Sensibilidade Microbiana , Viabilidade Microbiana/efeitos dos fármacos
5.
J Fluoresc ; 22(5): 1301-11, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22718197

RESUMO

The ability to accurately measure cell viability is important for any cell-based research. Traditionally, viability measurements have been performed using trypan blue exclusion method on hemacytometer, which allowed researchers to visually distinguish viable from nonviable cells. However, the trypan blue method is often limited to only cell lines or primary cells that have been rigorously purified. In the recent years, small desktop image-based cell counters have been developed for rapid cell concentration and viability measurement due to advances in imaging and optics technologies as well as novel fluorescent stains. In this work, we employed the Cellometer image-based cytometer to demonstrate the ability to simplify viability detection compared to the current methods. We compared various fluorescence viability detection methods using single- or dual-staining technique. Single-staining method using nucleic acid stains including ethidium bromide, propidium iodide, 7AAD, DAPI, Sytox Green and Sytox Red, and enzymatic stains including CFDA and Calcein AM were performed. All stains produced comparable results to trypan blue exclusion method for cell line samples. Dual-staining method using AO/PI, CFDA/PI, Calcein AM/PI and Hoechst 33342/PI that enumerates viable and non-viable cells was tested on primary cell samples with high debris contents. This method allowed exclusion of cellular debris and non-nucleated cells from analysis, which can eliminate the need to perform purification step during sample preparation, and improves the efficiency of viability detection method. Overall, these image-based fluorescent cell counters can simplify assay procedures as well as capture images for visual confirmation.


Assuntos
Citometria por Imagem/métodos , Coloração e Rotulagem/métodos , Sobrevivência Celular , DNA/metabolismo , Enzimas/metabolismo , Corantes Fluorescentes/metabolismo , Humanos , Células Jurkat , Leucócitos Mononucleares/citologia , Reprodutibilidade dos Testes , Baço/citologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA