Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sci Adv ; 7(32)2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34362737

RESUMO

In stretchable electronics, high-resolution stretchable interfacing at a mild temperature is considered as a great challenge and has not been achieved yet. This study presents a stretchable anisotropic conductive film (S-ACF) that can electrically connect high-resolution stretchable circuit lines to other electrodes whether they are rigid, flexible, or stretchable. The key concepts of this study are (i) high-resolution (~50 µm) but low-contact resistance (0.2 ohm in 0.25 mm2) interfacing by periodically embedding conductive microparticles in thermoplastic film, (ii) low-temperature interfacing through the formation of chemical bonds between the S-ACF and the substrates, (iii) economical interfacing by selectively patterning the S-ACF, and (iv) direct interfacing of chips by using the adhesion of the thermoplastic matrix. We integrate light-emitting diodes on the patterned S-ACF and demonstrate stable light operation at large biaxial areal stretching (εxy = 70%).

2.
Adv Mater ; 33(31): e2100299, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34155682

RESUMO

Although various stretchable optoelectronic devices have been reported, omni-directionally stretchable transparent circuit lines have been a great challenge. Cracks are engineered and fabricated to be highly conductive patterned metal circuit lines in which gold (Au) grids are embedded. Au is deposited selectively in the cracks to form a grid without any junction between the grid lines. Since each grid line is expandable under stretching, the circuit lines are stretchable in all the directions. This study shows that a thin coating of aluminum on the oxide surface enables precise control of the cracks (crack density, crack depth) in the oxide layer. High optical transparency and high stretchability can be achieved simultaneously by controlling the grid density in the circuit line. Light-emitting diodes are integrated directly on the circuit lines and stable operation is demonstrated under 100% stretching.

3.
Adv Mater ; 32(22): e1907477, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32319128

RESUMO

Although structural coloring and photoluminescence (PL) have been investigated for radiation-responsive color change, electroluminescence (EL) has not been used for the radiation-responsive system. An electro-photoluminescence (EPL) color change is presented here. The phosphors in the alternating current electroluminescence (ACEL) act simultaneously as electro-luminophores and photo-luminophores. The EPL chromaticity is systematically investigated depending on the ACEL frequency and UV intensity. It is found that the PL variation depending on UV intensity is the mechanism of the EPL color change. It is revealed that EL and PL can be controlled independently in the low electric field so that the EPL chromaticity can be adjusted by a linear combination of the EL color and the PL color. The EPL color-changing device is used as a deformable visual encryption system and a soft skin for a soft robotic rover, imitating the concealment and signaling functions in nature.

4.
J Environ Radioact ; 100(9): 746-51, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19188006

RESUMO

Greenhouse experiments were performed to investigate the root uptake of radionuclides following their acute soil deposition during the growth of several food crops. For this purpose, the soil under the standing plants was contaminated without any direct contamination of their stems or leaves. The intention of this design was to differentiate foilar uptake and root uptake subsequent to a radionuclide deposition during the vegetation period. Soil-to-plant transfer of a radionuclide was quantified with its aggregated transfer factors specified for the time periods from deposition until harvest (T(ag)(a), m(2)kg(-1)). Deposition time-dependent T(ag)(a) values of Mn, Co, Sr and Cs for selected crop species were measured in an acid sandy soil. For rice and Chinese cabbage, HTO experiments were also carried out using this soil. Particularly for rice, experiments with various paddy soils were also performed for (90)Sr and (137)Cs. The obtained T(ag)(a) values varied considerably with the radionuclides, plant species, and times of deposition. Recommendations about, and limitations in, the use of the T(ag)(a) values were discussed.


Assuntos
Raízes de Plantas/metabolismo , Plantas Comestíveis/metabolismo , Poluentes Radioativos do Solo/metabolismo , Solo/análise , Radioisótopos de Césio/análise , Radioisótopos de Césio/metabolismo , Modelos Teóricos , Folhas de Planta/metabolismo , Poluentes Radioativos do Solo/análise , Radioisótopos de Estrôncio/análise , Radioisótopos de Estrôncio/metabolismo
5.
Appl Radiat Isot ; 58(5): 579-83, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12735975

RESUMO

We developed an ultralow-level background gamma-ray spectrometer, using active and passive shield devices at the same time. Cosmic-ray-induced background is suppressed by means of active shield devices consisting of plastic scintillating plates of 50mm thick and anti-coincidence electronic system. The observed background rate was 0.34 s(-1) (=0.12s(-1) per 100 cm(3) Ge volume) for energy regions between 50 and 3000 ke V. The detection efficiency curve for 10(3)ml Marinelli beaker samples is obtained over all the energy regions. The advantages of the method are demonstrated by measuring the activity of 137Cs in powdered milk sample prepared without taking any chemical procedure. The MDA for 137Cs is estimated to be (17+/-1.7)mBq at a confidence level of 95% and it is about a factor of 10 lower than the MDA obtained from the previous cryostat assembly with 10-cm thick lead shielding.


Assuntos
Poluentes Ambientais/análise , Análise de Alimentos/instrumentação , Proteção Radiológica/instrumentação , Radioisótopos/análise , Espectrometria gama/instrumentação , Animais , Radioisótopos de Césio/análise , Radiação Cósmica , Análise de Alimentos/métodos , Contaminação Radioativa de Alimentos/análise , Germânio , Leite/química , Pós , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA