RESUMO
Objective: Balloon dilation of Eustachian tube (BDET) has been widely used as a minimally invasive treatment for obstructive Eustachian tube dysfunction (ETD). We used a Delphi consensus methodology to explore recommendations for clinical management of BDET in obstructive ETD. Procedure: A Delphi panel of 26 expert physicians of otology participated in two rounds of anonymous, iterative questionnaires. Consensus is defined as ≥ 70% of panelists agree with recommendation and disagreement as < 70% agree. The responses from the Delphi study were analyzed using both the content validity ratio and Kendall's coefficient of concordance. Results: The panel finally evaluated 26 topics, agreed 9 and did not reach consensus on 17 topics after 2 rounds. Although no consensus was reached on the postoperative follow-up period, a period of 12 months was most adopted. The Valsalva maneuver and questionnaire responses showed the highest agreement as postoperative assessment tools after BDET. Conclusion: Consensus was reached on some of the recommendations for the management of BEDT in obstructive ETD. The resultant agreement will provide directions for future research to describe standard postoperative management of BDET.
RESUMO
OBJECTIVE: This study aimed to compare the accuracy of two transferring methods, which are the intermediate splint made by computer-aided design (CAD)/computer-aided manufacturing (CAM) and the customized maxillary repositioning guide for orthognathic surgery. MATERIALS AND METHODS: Patient data regarding virtual surgical simulations were collected. For analyzing the accuracy, the postoperative cone-beam computed tomography and preoperative simulation data were superimposed. The x, y, and z coordinates were obtained at three landmarks in the maxillary dentition, and the linear and angular differences between the surgical simulation and the actual surgery were evaluated. RESULTS: Thirty-three patients were included in this study, 16 in the splint group and 17 in the guide group. One coordinate in the guide group and nine in the splint group showed errors of >2 mm, with a statistically significant difference. There was no significant difference between the two groups in the three-dimensional error distance at each reference point. In most measurements, the interquartile range of the guide group showed a narrower distribution than that of the splint group. CONCLUSION: It is more advantageous to use a customized maxillary repositioning guide than an intermediate splint made via CAD/CAM to obtain an accuracy within the 2 mm discrepancy range.
RESUMO
BACKGROUND: Relapses following orthognathic surgery have been reported to exceed 2% to 50%, depending on multiple factors. This study aimed to analyze the stability after orthognathic surgery in patients with mandibular ramus height asymmetry through 3D reconstruction using Cone-beam CT. METHODS: This retrospective cohort study investigated patients who underwent mandibular setback surgery using bilateral sagittal split ramus osteotomy. Three-dimensional CT scans were taken at three different time points. Evaluation of the postoperative stability involved measuring changes in the x, y, and z axes as well as roll and yaw rotations of the mandible at specific landmarks (B point, mental foramen) on 3D CT scans obtained immediately after surgery and 6-12 months postoperatively. They were categorized into four groups based on bilateral mandibular height asymmetry through Asymmetry index (AI). The one-way ANOVA was implemented to compare the intergroup differences and Tukey's post hoc test was employed. Additionally, the Pearson correlation coefficient was also calculated. RESULTS: A total of 24 patients were included in this study. The corresponding AI, representing the degree of asymmetry in both mandibles, were calculated as Group 1 was 1.25 ± 0.64%, Group 2 was 2.89 ± 0.47%, Group 3 was 5.03 ± 0.51%, and Group 4 was 9.40 ± 1.99%. The x-axis change in Group 4 was significantly larger at 1.71 mm compared to Group 1 at 0.64 mm. The mandibular roll, Group 4 showed a statistically significant increase at 1.33° compared to Group 1 at 0.35°. And there was a significant positive correlation observed between x-axis change and AI (p = 0.019), as well as between mandibular roll and AI (p = 0.025). CONCLUSION: After orthognathic surgery, stability was influenced by numerous factors, with the findings of this study suggesting that the degree of ramus height asymmetry in the mandible can be considered one contributing factor.
RESUMO
OBJECTIVE: To review a 3-year case series of endoscopic butterfly inlay cartilage myringoplasty performed by a single surgeon (W.S.K.) and analyze the clinical surgical outcomes. STUDY DESIGN: Retrospective study. SETTING: Tertiary care academic center. PATIENTS: We enrolled 60 ears with tympanic membrane (TM) perforation, receiving endoscopic inlay butterfly myringoplasty between 2019 and 2022. MAIN OUTCOMES AND MEASURES: We reviewed patients' demographics, size and location of TM perforation, operation time, complications, and postoperative pain evaluated by the numerical rating scale (NRS). We analyzed the graft uptake success rate in 5 weeks and the perforation closure rate in 4 months after surgery. We also compared the air-bone gap (ABG) before and after the surgery. RESULTS: Among the 60 ears included, the mean age was 57.0 years, and 78.3% (47 of 60) had small perforations. The average operation time was 48.9 ± 11.5 minutes, and the postoperative NRS was 2.0 ± 1.6. The immediate graft uptake success rate evaluated at postoperative 5 weeks was 96.7% (58 of 60), with myringitis occurring in three ears. Except for 11 patients lost to follow-up, the perforation closure rate evaluated at postoperative 4 months was 100% (49 of 49). The mean ABG significantly improved from preoperative status (8.87 ± 5.51 dB HL) to postoperative 4 months (6.22 ± 6.03 dB HL) ( p = 0.019). CONCLUSIONS: A single surgeon's success rate for endoscopic butterfly inlay cartilage myringoplasty was almost 100%. This surgical procedure is safe and effective, with a high graft success rate.
Assuntos
Endoscopia , Miringoplastia , Perfuração da Membrana Timpânica , Humanos , Perfuração da Membrana Timpânica/cirurgia , Miringoplastia/métodos , Feminino , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Endoscopia/métodos , Resultado do Tratamento , Adulto , Idoso , Cartilagem/transplanteRESUMO
PURPOSE: Single-sided deafness (SSD) presents significant challenges for patients, including compromised sound localization, reduced speech recognition, and often, tinnitus. These issues are typically addressed using interventions such as cochlear implantation (CI) and bone conduction implant (BCI). However, evidence regarding the efficacy of BCI in reducing tinnitus in SSD patients remains limited. This study explored the ability of a novel active transcutaneous BCI (Bonebridge BCI602) to alleviate tinnitus in SSD patients. STUDY DESIGN: Prospective cohort multicenter study. SETTING: Tertiary referral hospitals. METHODS: A prospective multicenter study of 30 SSD patients was conducted. The patients were divided into two groups: those with (n = 19) and without (n = 11) tinnitus. Audiometric assessments, subjective questionnaires including the Abbreviated Profile of Hearing Aid Benefit (APHAB) and the Bern Benefit in Single-Sided Deafness (BBSS), and tinnitus evaluations with the Tinnitus Handicap Inventory (THI) and tinnitogram were conducted before and after BCI surgery. RESULTS: THI scores after surgery were significantly reduced in SSD patients with tinnitus. Subjective satisfaction improved in both the tinnitus and non-tinnitus groups; however, the former group exhibited a significantly greater improvement in the APHAB questionnaire score. According to tinnitograms, the loudness of tinnitus decreased, particularly in patients with ipsilateral tinnitus. Patients with residual hearing had greater reductions in their THI scores. However, three patients without residual hearing had a relative worsening of tinnitus after surgery. CONCLUSION: The Bonebridge BCI602 effectively reduced tinnitus in SSD patients, particularly in those with residual hearing. Subjective satisfaction improved in both the tinnitus and non-tinnitus groups. These findings demonstrate the therapeutic potential of BCI for managing SSD and associated tinnitus.
Assuntos
Condução Óssea , Perda Auditiva Unilateral , Zumbido , Humanos , Estudos Prospectivos , Masculino , Zumbido/cirurgia , Zumbido/fisiopatologia , Feminino , Pessoa de Meia-Idade , Perda Auditiva Unilateral/reabilitação , Perda Auditiva Unilateral/cirurgia , Perda Auditiva Unilateral/fisiopatologia , Adulto , Idoso , Resultado do Tratamento , Auxiliares de Audição , Inquéritos e QuestionáriosRESUMO
This study aims to analyse the volumetric changes in brain MRI after cochlear implantation (CI), focusing on the speech perception in postlingually deaf adults. We conducted a prospective cohort study with 16 patients who had bilateral hearing loss and received unilateral CI. Based on the surgical side, patients were categorized into left and right CI groups. Volumetric T1-weighted brain MRI were obtained before and one year after the surgery. To overcome the artifact caused by the internal device in post-CI scan, image reconstruction method was newly devised and applied using the contralateral hemisphere of the pre-CI MRI data, to run FreeSurfer. We conducted within-subject template estimation for unbiased longitudinal image analysis, based on the linear mixed effect models. When analyzing the contralateral cerebral hemisphere before and after CI, a substantial increase in superior frontal gyrus and superior temporal gyrus (STG) volumes was observed in the left CI group. A positive correlation was observed in the STG and post-CI word recognition score in both groups. As far as we know, this is the first study attempting longitudinal brain volumetry based on post-CI MRI scans. We demonstrate that better auditory performance after CI is associated with structural restoration in central auditory structures.
Assuntos
Implante Coclear , Surdez , Imageamento por Ressonância Magnética , Percepção da Fala , Humanos , Masculino , Feminino , Implante Coclear/métodos , Percepção da Fala/fisiologia , Imageamento por Ressonância Magnética/métodos , Surdez/fisiopatologia , Surdez/cirurgia , Surdez/diagnóstico por imagem , Adulto , Pessoa de Meia-Idade , Estudos Prospectivos , Idoso , Implantes CoclearesRESUMO
Closed treatment of mandibular condylar fractures has been used for its indications based on the fracture site, fracture status, and patient age. Posttreatment mandibular condyle size is associated with mandibular function; however, a few studies have reported bone remodeling patterns and volume changes in the condyle and glenoid fossa after mandibular condylar head fractures (CHFs). Therefore, volumetric changes in the mandibular condyle and glenoid fossa were analyzed in the present study, and bone remodeling patterns were evaluated after mandibular CHFs. The present study included 16 condyles from 12 patients who received closed treatment for CHF. After reconstruction of a 3-dimensional skull model, including the mandible, using computed tomography data taken immediately after injury and 6 months after treatment, volume changes in the mandibular condyle and glenoid fossa were analyzed. The condylar volume increased by 0.32±0.66 cm3 during the 6-month healing period without statistical significance (P=0.093). Regarding the glenoid fossa, the fossa showed a statistically significant volume increase of 0.41±0.59 cm3 (P=0.021), and 12 glenoid fossae (75%) showed downward bone apposition; however, no change or only mild bone resorption was observed in 4 glenoid fossae (25%). The results of this study indicated that the volume changes in the mandibular condyle after closed treatment of a mandibular CHF are not significant, and the glenoid fossa adapts to the displaced mandibular condyle through downward growth accompanied by volume increase.
RESUMO
BACKGROUND AND OBJECTIVES: Additional needs refer to specific requirements or support for individuals with disabilities or syndromes. Intellectual ability is a crucial outcome determinant of a cochlear implant. The social quotient (SQ) is an indirect predictor of intellectual capacity and social skills. This study aimed to investigate the clinical significance of the SQ on children with additional needs who received cochlear implants. Subjects and. METHODS: This study included 24 patients with diagnosed developmental delays and syndromes, who demonstrated SQ scores of <70. Preoperative social skills were evaluated using the SQ. All patients underwent cochlear implantation (CI) surgery before 7 years of age. Outcomes were evaluated using the Infant-Toddler Meaningful Auditory Integration Scale (IT-MAIS) and Categories of Auditory Performance (CAP) scores. Data were collected through a retrospective chart review. RESULTS: Children were categorized into three groups based on their SQ. There were no correlations between the preoperative SQ and IT-MAIS or CAP scores at 2 and 5 years of follow-up postoperatively. The CI outcomes of children with low SQ (<70) differed from those with normal development (SQ>70). In the low-SQ group, inner ear anomalies were observed in 10 (41.7%) patients. Although not statistically significant, these children exhibited a trend of lower average outcomes than children without inner ear anomalies. CONCLUSIONS: CI outcomes in children with additional needs positively affected auditory performance. Postoperative auditory and language skills tended to improve slowly in children with additional needs and a lower SQ. Over time, development gradually became more comparable to the other groups of children. However, this improvement was less than that observed in children without additional needs. Our findings support CI for children with additional needs as part of long-term auditory rehabilitation following surgery.
RESUMO
Eustachian tube balloon dilatation (ETBD) has shown promising results in the treatment of ET dysfunction (ETD); however, recurrent symptoms after ETBD frequently occur in patients with refractory ETD. The excessive pressure of balloon catheter during ETBD may induce the tissue hyperplasia and fibrotic changes around the injured mucosa. Sirolimus (SRL), an antiproliferative agent, inhibits tissue proliferation. An SRL-coated balloon catheter was fabricated using an ultrasonic spray coating technique with a coating solution composed of SRL, purified shellac, and vitamin E. This study aimed to investigate effectiveness of ETBD with a SRL-coated balloon catheter to prevent tissue proliferation in the rat ET after ETBD. In 21 Sprague-Dawley rats, the left ET was randomly divided into the control (drug-free ETBD; n = 9) and the SRL (n = 9) groups. All rats were sacrificed for histological examination immediately after and at 1 and 4 weeks after ETBD. Three rats were used to represent the normal ET. The SRL-coated ETBD significantly suppressed tissue proliferation caused by mechanical injuries compared with the control group. ETBD with SRL-coated balloon catheter was effective and safe to maintain ET luminal patency without tissue proliferation at the site of mechanical injuries for 4 weeks in a rat ET model.
Assuntos
Otopatias , Tuba Auditiva , Humanos , Ratos , Animais , Dilatação/métodos , Ratos Sprague-Dawley , Cateterismo/métodos , Otopatias/terapia , Otopatias/diagnóstico , Resultado do TratamentoRESUMO
OBJECTIVE: To investigate the long-term educational and occupational status of prelingually bilateral deaf children who received a cochlear implant (CI) before the age of 7, and to identify factors that influence these outcomes. STUDY DESIGN: Retrospective chart review. SETTING: Single tertiary care center. METHODS: Seventy-one children who underwent CI surgery from 2000 to 2007 were included. The latest education and occupation status and word recognition score (WRS) were analyzed. RESULTS: The mean age at the time of surgery and the current age was 3.9 and 22.4 years. The age at CI showed a negative correlation with WRS. All subjects had graduated from high school or obtained an equivalent educational qualification. General high school graduates showed a higher WRS than those who attended a special education high school. The college entrance rate of CI patients (74.6% %) was comparable to that of the general population (72.5%). Subjects who went to college had a significantly better WRS than those who did not (51.4% vs 19.3%). Excluding 30 subjects currently enrolled in college, 26 (62%) of the remaining 41 were currently employed and engaged in various vocational activities, of which most (21 out of 26, 81%) were employed through vocational training institutes, or via special recruitment policy for the disabled. CONCLUSION: The long-term use of CI in prelingually deaf children enables not only speech perception but also produces comparable levels of education and employment to those of the general population. A good WRS and supportive policy were related to these successful outcomes.
Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Percepção da Fala , Criança , Humanos , Pré-Escolar , Adolescente , Adulto Jovem , Adulto , Estudos Retrospectivos , Surdez/cirurgia , Surdez/reabilitação , EmpregoRESUMO
OBJECTIVE: To investigate the safety and efficacy of a novel active transcutaneous bone conduction implant (BCI) device for patients with single-sided deafness (SSD). STUDY DESIGN: Prospective cohort study. SETTING: Tertiary referral hospitals. METHODS: This prospective multicenter study was conducted at 15 institutions nationwide. Thirty adult (aged ≥19 years) SSD patients were recruited. They underwent implantation of an active transcutaneous BCI device (Bonebridge BCI602). Objective outcomes included aided pure-tone thresholds, aided speech discrimination scores (SDSs), and the Hearing in Noise Test (HINT) and sound localization test results. The Bern Benefit in Single-Sided Deafness (BBSS) questionnaire, the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire, and the Tinnitus Handicap Inventory (THI) were used to measure subjective benefits. RESULTS: The mean aided pure-tone threshold was 34.2 (11.3), mean (SD), dB HL at 500 to 4000 Hz. The mean total BBSS score was 27.5 (13.8). All APHAB questionnaire domain scores showed significant improvements: ease of communication, 33.6 (23.2) versus 22.6 (21.3), P = .025; reverberation, 44.8 (16.6) versus 32.8 (15.9), P = .002; background noise, 55.5 (23.6) versus 35.2 (18.1), P < .001; and aversiveness, 36.7 (22.8) versus 25.8 (21.4), P = .028. Moreover, the THI scores were significantly reduced [47.4 (30.1) versus 31.1 (27.0), P = .003]. Congenital SSD was a significant factor of subjective benefit (-11.643; 95% confidence interval: -21.946 to -1.340). CONCLUSION: The BCI602 active transcutaneous BCI device can provide functional hearing gain without any adverse effects and is a feasible option for acquired SSD patients with long-term deafness.
Assuntos
Surdez , Auxiliares de Audição , Percepção da Fala , Zumbido , Adulto , Humanos , Estudos Prospectivos , Condução Óssea , Audição , Surdez/cirurgia , Resultado do TratamentoRESUMO
Life-threatening airway obstruction is a major concern in patients with Pierre-Robin sequence. Tongue-lip adhesion (TLA) has been used to manage airway obstruction. The authors present the case of a female neonate with Pierre-Robin sequence who presented with airway obstruction and a cleft palate. She underwent a TLA procedure with modified tongue base suspension (TBS). Endoscopy was used to check and control the traction of the tongue base to enable unobstructed self-ventilation. Positive outcomes including improved O2 saturation and weight gain were noted. The effectiveness of TLA was enhanced by using TBS with real-time endoscopy to evaluate the oropharyngeal airway space required to alleviate airway obstruction. The use of endoscopy enabled us to check and determine how much the tongue base should be tracted by manipulating the tongue anteriorly and posteriorly. The authors report transoral endoscopy-assisted TLA and modified TBS.
Assuntos
Obstrução das Vias Respiratórias , Laringe , Síndrome de Pierre Robin , Recém-Nascido , Humanos , Feminino , Síndrome de Pierre Robin/cirurgia , Língua/cirurgia , Endoscopia , Resultado do TratamentoRESUMO
BACKGROUND: Mandibular condyle remodeling and displacement are post-orthognathic surgery concerns that can potentially lead to occlusal issues after bilateral sagittal split ramus osteotomy. This retrospective study examined the relationship between condylar volume changes and position alterations after surgery in patients with skeletal class II and III malocclusions using cone-beam CT. METHODS: The study included 16 patients (6 with Class II malocclusion, 10 with Class III malocclusion) who underwent bilateral sagittal split ramus osteotomy at Chonnam National University Hospital. Cone-beam CT data were collected at three specific time points: before surgery, immediately after surgery, and approximately 6 months post-surgery. Mandibular movement was measured using InVivoDental 5.4.6. ITK-SNAP 3.8.0 was used to assessed condylar volume changes post-surgery. Condyle positions were evaluated in four parts with RadiAnt DICOM Viewer 4.6.9. Statistical analyses were performed using the SPSS version 23. RESULTS: Considering both Class II and III malocclusion, a 2.91% volume reduction was noted immediately and at 6 months after surgery. Both Class II and III cases demonstrated a decrease in superior joint space by -0.59 mm and medial joint space by -1.09 mm. No significant correlation was found between this process and condylar volume change. CONCLUSIONS: The mandibular condyle volume decreased, and superior-medial movement of the condyle was detected in patients with Class II and III malocclusion immediately and at 6 months after surgery with no volume-position correlation.
RESUMO
Background: Video head impulse tests (vHITs), assessing the vestibulo-ocular reflex (VOR), may be helpful in the differential diagnosis of acute dizziness. We aimed to investigate vHITs in patients with acute posterior circulation stroke (PCS) to examine whether these findings could exhibit significant abnormalities based on lesion locations, and to evaluate diagnostic value of vHIT in differentiating dizziness between PCS and vestibular neuritis (VN). Methods: We prospectively recruited consecutive 80 patients with acute PCS and analyzed vHIT findings according to the presence of dorsal brainstem stroke (DBS). We also compared vHIT findings between PCS patients with dizziness and a previously studied VN group (n = 29). Receiver operating characteristic (ROC) analysis was performed to assess the performance of VOR gain and its asymmetry in distinguishing dizziness between PCS and VN. Results: Patients with PCS underwent vHIT within a median of 2 days from stroke onset. Mean horizontal VOR gain was 0.97, and there was no significant difference between PCS patients with DBS (n = 15) and without (n = 65). None exhibited pathologic overt corrective saccades. When comparing the PCS group with dizziness (n = 40) to the VN group (n = 29), patients with VN demonstrated significantly lower mean VOR gains in the ipsilesional horizontal canals (1.00 vs. 0.57, p < 0.001). VOR gain and their asymmetry effectively differentiated dizziness in the PCS from VN groups, with an area under the ROC curve of 0.86 (95% CI 0.74-0.98) and 0.91 (95% CI 0.83-0.99, p < 0.001), respectively. Conclusion: Significantly abnormal vHIT results were rare in patients with acute PCS, even in the presence of DBS. Moreover, vHIT effectively differentiated dizziness between PCS and VN, highlighting its potential for aiding differential diagnosis of acute dizziness.
RESUMO
Reactive oxygen species (ROS)-sensitive polymer nanoparticles were synthesized for tumor targeting of an anticancer drug, doxorubicin (DOX). For this purpose, chitosan-methoxy poly(ethylene glycol) (mPEG) (ChitoPEG)-graft copolymer was synthesized and then DOX was conjugated to the backbone of chitosan using a thioketal linker. Subsequently, the chemical structure of the DOX-conjugated ChitoPEG copolymer (ChitoPEGthDOX) was confirmed via 1H nuclear magnetic resonance (NMR) spectra. Nanoparticles of the ChitoPEGthDOX conjugates have spherical shapes and a size of approximately 100 nm. Transmission electron microscopy (TEM) has shown that ChitoPEGthDOX nanoparticles disintegrate in the presence of hydrogen peroxide and the particle size distribution also changes from a monomodal/narrow distribution pattern to a multi-modal/wide distribution pattern. Furthermore, DOX is released faster in the presence of hydrogen peroxide. These results indicated that ChitoPEGthDOX nanoparticles have ROS sensitivity. The anticancer activity of the nanoparticles was evaluated using AT84 oral squamous carcinoma cells. Moreover, DOX-resistant AT84 cells were prepared in vitro. DOX and its nanoparticles showed dose-dependent cytotoxicity in both DOX-sensitive and DOX-resistant AT84 cells in vitro. However, DOX itself showed reduced cytotoxicity against DOX-resistant AT84 cells, while the nanoparticles showed almost similar cytotoxicity to DOX-sensitive and DOX-resistant AT84 cells. This result may be due to the inhibition of intracellular delivery of free DOX, while nanoparticles were efficiently internalized in DOX-resistant cells. The in vivo study of a DOX-resistant AT84 cell-bearing tumor xenograft model showed that nanoparticles have higher antitumor efficacy than those found in free DOX treatment. These results may be related to the efficient accumulation of nanoparticles in the tumor tissue, i.e., the fluorescence intensity in the tumor tissue was stronger than that of any other organs. Our findings suggest that ChitoPEGthDOX nanoparticles may be a promising candidate for ROS-sensitive anticancer delivery against DOX-resistant oral cancer cells.
RESUMO
BACKGROUND: The present study describes the treatment of patients at a tertiary institution who experienced device failure after Cochlear Implantation (CI), as well as identifying prodromic symptoms that could assist in the timely identification and management of device failure. STUDY DESIGN: Retrospective database review (January 2000-May 2017). SETTING: Single tertiary hospital. METHODS: Factors recorded included the etiology of hearing loss; age at first and revision CI surgeries; surgical information, including operation time and approach; electrical outcomes after implantation; device implanted; symptoms of device failure; history of head trauma; and audiologic outcomes as determined by categories of auditory performance (CAP). RESULTS: From January 2000 to May 2017, 1431 CIs were performed, with 27 (1.9%) undergoing revision surgeries due to device failure. The most common etiology of hearing loss was idiopathic (12/27), followed by cochlear hypoplasia (5/27). Mean age at initial CI was 11.8 (1-72) years, with 21 being pre-lingual and 6 being post-lingual. Of the total devices initially implanted, 80.5% were from Cochlear, 15.9% from MED-EL, and 3.5% from Advanced Bionics. The failure rates of these devices were 1.3%, 3.1%, and 10.0%, respectively. The most suggestive symptom of device failure was intermittent loss of signal. Mean CAP scores were 5.17 before reimplantation and 5.54 and 5.81 at 1- and 3-years, respectively, after reimplantation. CONCLUSION: The most suggestive symptom preceding device failure was intermittent loss of signal. Patients who present with this symptom should undergo electrical examination for suspected device failure. Audiologic outcomes showed continuous development despite revision surgeries.
Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva , Humanos , Implante Coclear/efeitos adversos , Estudos Retrospectivos , Perda Auditiva/etiologia , Perda Auditiva/cirurgia , Implantes Cocleares/efeitos adversos , Reoperação , Falha de EquipamentoRESUMO
OBJECTIVE: To analyze the long-term auditory performance after cochlear implantation (CI) and identify anatomical features of Mondini dysplasia associated with post-CI outcomes. STUDY DESIGN: Retrospective study. SETTING: Tertiary care academic center. PATIENTS: We enrolled 49 ears with Mondini dysplasia who underwent CI with more than 7 years of follow-up and age at CI- and sex-matched control group with radiologically normal inner ears. MAIN OUTCOMES AND MEASURES: The development of auditory skills after CI was evaluated using word recognition scores (WRSs). The anatomical features were measured based on temporal bone computed tomography and magnetic resonance imaging, involving the width of the bony cochlear nerve canal (BCNC), cochlear basal turn, enlarged vestibular aqueduct, cochlear height, and diameter of the cochlear nerve (CN). RESULTS: CI in ears with Mondini dysplasia showed comparable benefits and improvement of auditory performance to controls during the 7 years of follow-up. In Mondini dysplasia, four (8.2%) ears showed narrow BCNC (<1.4 mm) with poorer WRS (58 ± 17%) than those with normal-sized BCNC, which had WRS (79 ± 10%) comparable to that of the control group (77 ± 14%). In Mondini dysplasia, the maximum ( r = 0.513, p < 0.001) and minimum ( r = 0.328, p = 0.021) CN diameters had positive correlations with post-CI WRS. The maximum CN diameter ( ß = 48.347, p < 0.001) and BCNC width ( ß = 12.411, p = 0.041) were significant factors that influence the post-CI WRS in multiple regression analysis. CONCLUSIONS: Preoperative anatomical evaluation, especially BCNC status and CN integrity, may serve as predictive markers for post-CI performance.
Assuntos
Implante Coclear , Orelha Interna , Perda Auditiva Neurossensorial , Criança , Humanos , Implante Coclear/métodos , Estudos Retrospectivos , Perda Auditiva Neurossensorial/diagnóstico por imagem , Perda Auditiva Neurossensorial/cirurgia , Perda Auditiva Neurossensorial/patologia , Orelha Interna/cirurgia , Cóclea/cirurgia , Nervo Coclear/cirurgiaRESUMO
Purpose: This study investigated the anatomical and histological characteristics of the rat Eustachian tube (E-tube) and the feasibility of Eustachian tubography in a rat model. Materials and methods: Fifteen male Wistar rats were used in this study, and the bilateral E-tubes of each rat were examined. Ten E-tubes were used for anatomical studies, another ten for histological analysis, and the other ten for Eustachian tubography. Five rats were euthanized and decapitated, and ten E-tubes were dissected to describe the anatomy of the E-tube. Ten E-tube specimens obtained from five other rats were sectioned to investigate E-tube histology. Eustachian tubography was performed on the bilateral E-tubes of the other five rats using the trans-tympanic approach. Results: The rat E-tubes consisted of bony and membranous parts. Cartilage and bone tissue covered only the bony part. The E-tubes' mean diameter and overall length were 2.97 âmm and 4.96 âmm, respectively. The tympanic orifices' mean diameter was 1.21 âmm. The epithelium of E-tubes was mainly composed of pseudostratified ciliated and goblet cells. Eustachian tubography was successfully performed on both sides of the E-tube for each rat. The technical success rate was 100%, the average running time was 4.9 âmin, and no procedure-related complications occurred. On tubography images, the E-tube, tympanic cavity, and nasopharynx could be identified because of the visualization of bony landmarks. Conclusion: In this study, we described the anatomical and histological features of rat E-tubes. With the aid of these findings, E-tube angiography was successfully performed using a transtympanic approach. These results will facilitate further investigation of E-tube dysfunction.
RESUMO
BACKGROUND: Computer-aided design and manufacturing (CAD/CAM) is widely used in clinical practice. This technology may change existing methods for mandibular fracture management. PURPOSE: The purpose of this in-vitro study was to determine if the reduction for mandibular symphysis fracture can be performed without maxillomandibular fixation (MMF) using 3-dimensional (3D)-printed template. STUDY DESIGN, SETTING, AND SAMPLE: This in-vitro study was designed as a proof-of-concept. The sample was composed of 20 existing pairs of intraoral scan and computed tomography (CT) data. A mandibular model stereolithography (STL) file was created by merging the STL file obtained for the bimaxillary dentitions with the CT DICOM file, and this was set as the original model. Using the original model, a STL file of a fracture model of the mandibular symphysis was created using CAD. A template similar to a wafer or an implant guide was manufactured to restore original occlusion, and the mandibular fracture model was reduced and fixed using the 3D-printed template and wire. This was set as the experimental group. The 3D coordinate system error was measured at 6 landmarks and statistically compared using scan data between models of the groups. PREDICTOR/EXPOSURE/INDEPENDENT VARIABLES: Reduction techniques with MMF or without MMF using guide template for mandibular fracture model. MAIN OUTCOME VARIABLE(S): The 3D coordinate system error (mm). COVARIATES: The position of landmarks. ANALYSES: The Mann-Whitney U test, student's t-test, and the Kruskal-Wallis test were used to analyze the coordinate errors between the landmarks. A P value of < .05 was considered statistically significant. RESULTS: The 3D error value of the control and experimental group were 1.06 ± 0.63 mm (range: 0.11 to 2.92 mm) and 0.96 ± 0.48 mm (range: 0.2 to 2.95 mm), respectively. There was no statistical difference between the control and experimental group. There was a statistically significant difference in the lower 2 and lower 3 landmarks compared to the upper 1 (P = .001 and .000, respectively) before and after the reduction in the experimental group. CONCLUSION AND RELEVANCE: This study demonstrates that the reduction using a 3D-printed guide template for the mandibular symphysis fracture could be possible even without the MMF.
Assuntos
Fraturas Mandibulares , Impressão Tridimensional , Humanos , Fraturas Mandibulares/diagnóstico por imagem , Fraturas Mandibulares/cirurgia , Técnicas de Fixação da Arcada Osseodentária , Desenho Assistido por Computador , Fixação de FraturaRESUMO
Absorbable magnesium (Mg) stents have an attractive biocompatibility and rapid degradation rate, but their degradable behavior and efficacy in the Eustachian tube (ET) have not yet been investigated. In this study, the degradable behavior of the Mg stent in artificial nasal mucus was evaluated. The Mg stents in the porcine ET model were also investigated to evaluate their safety and efficacy. Four Mg stents were placed into the four ETs of two pigs. The mass loss rate of the Mg stents gradually decreased over time. The decrease rates were 30.96% at one week, 49.00% at two weeks, and 71.80% at four weeks. On the basis of histological findings, the thickness of submucosal tissue hyperplasia and the degree of inflammatory cell infiltration significantly decreased at four weeks compared with two weeks. Biodegradation of the Mg stent occurred before tissue proliferative reactions, and the ET patency was successfully maintained without stent-induced tissue hyperplasia at four weeks. The Mg stent that biodegrades rapidly seems to be effective and safe in porcine ET. Further investigation is required to verify the optimal stent shape and indwell period in the ET.