Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 95
Filtrar
1.
Eur Heart J Cardiovasc Imaging ; 21(7): 805-813, 2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-31501858

RESUMO

BACKGROUND: Wave intensity analysis (WIA) in the aorta offers important clinical and mechanistic insight into ventriculo-arterial coupling, but is difficult to measure non-invasively. We performed WIA by combining standard cardiovascular magnetic resonance (CMR) flow-velocity and non-invasive central blood pressure (cBP) waveforms. METHODS AND RESULTS: Two hundred and six healthy volunteers (age range 21-73 years, 47% male) underwent sequential phase contrast CMR (Siemens Aera 1.5 T, 1.97 × 1.77 mm2, 9.2 ms temporal resolution) and supra-systolic oscillometric cBP measurement (200 Hz). Velocity (U) and central pressure (P) waveforms were aligned using the waveform foot, and local wave speed was calculated both from the PU-loop (c) and the sum of squares method (cSS). These were compared with CMR transit time derived aortic arch pulse wave velocity (PWVtt). Associations were examined using multivariable regression. The peak intensity of the initial compression wave, backward compression wave, and forward decompression wave were 69.5 ± 28, -6.6 ± 4.2, and 6.2 ± 2.5 × 104 W/m2/cycle2, respectively; reflection index was 0.10 ± 0.06. PWVtt correlated with c or cSS (r = 0.60 and 0.68, respectively, P < 0.01 for both). Increasing age decade and female sex were independently associated with decreased forward compression wave (-8.6 and -20.7 W/m2/cycle2, respectively, P < 0.01) and greater wave reflection index (0.02 and 0.03, respectively, P < 0.001). CONCLUSION: This novel non-invasive technique permits straightforward measurement of wave intensity at scale. Local wave speed showed good agreement with PWVtt, and correlation was stronger using the cSS than the PU-loop. Ageing and female sex were associated with poorer ventriculo-arterial coupling in healthy individuals.


Assuntos
Aorta , Análise de Onda de Pulso , Adulto , Idoso , Aorta/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Feminino , Humanos , Espectroscopia de Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Adulto Jovem
2.
Physiol Meas ; 39(10): 104003, 2018 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-30192235

RESUMO

OBJECTIVE: Hypertension is associated with reduced cerebral blood flow, but it is not known how this impacts on wave dynamics or potentially relates to arterial morphology. Given the location of the internal carotid artery (ICA) and risks associated with invasive measurements, wave dynamics in this artery have not been extensively assessed in vivo. This study explores the feasibility of studying wave dynamics in the internal carotid artery non-invasively. APPROACH: Normotensive, uncontrolled and controlled hypertensive participants were recruited (daytime ambulatory blood pressure <135/85 mmHg and >135/85 mmHg, respectively; n = 38). Wave intensity, reservoir pressure and statistical shape analyses were performed on the right ICA and ascending aorta high-resolution phase-contrast magnetic resonance angiography data. MAIN RESULTS: Wave speed in the aorta was significantly lower in normotensive compared to hypertensive participants (6.7 ± 1.8 versus 11.2 ± 6.2 m s-1 for uncontrolled and 11.8 ± 4.6 m s-1 for controlled hypertensives, p = 0.02), whilst there were no differences in wave speed in the ICA. There were no significant differences between the groups for the wave intensity or reservoir pressure. Interestingly, a significant association between the anatomy of the ICA and wave energy (FCW and size, r 2 = 0.12, p = 0.04) was found. SIGNIFICANCE: This study shows it is feasible to study wave dynamics in the ICA non-invasively. Whilst changes in aortic wave speed confirmed an expected increase in arterial stiffness, this was not observed in the ICA. This might suggest a protective mechanism in the cerebral circulation, in conjunction with the effect of vessel tortuosity. Furthermore, it was observed that ICA shape correlated with wave energy but not wave speed.


Assuntos
Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/fisiopatologia , Hipertensão/diagnóstico por imagem , Hipertensão/fisiopatologia , Angiografia por Ressonância Magnética/métodos , Aorta/diagnóstico por imagem , Aorta/patologia , Aorta/fisiopatologia , Determinação da Pressão Arterial , Artéria Carótida Interna/patologia , Estudos de Viabilidade , Feminino , Humanos , Hipertensão/patologia , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade
4.
J Hum Hypertens ; 31(5): 305-312, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-28004730

RESUMO

Little is known about how aortic waveform parameters vary with ethnicity and lifestyle factors. We investigated these issues in a large, population-based sample. We carried out a cross-sectional analysis of 4798 men and women, aged 50-84 years from Auckland, New Zealand. Participants were 3961 European, 321 Pacific, 266 Maori and 250 South Asian people. We assessed modifiable lifestyle factors via questionnaires, and measured body mass index (BMI) and brachial blood pressure (BP). Suprasystolic oscillometry was used to derive aortic pressure, from which several haemodynamic parameters were calculated. Heavy alcohol consumption and BMI were positively related to most waveform parameters. Current smokers had higher levels of aortic augmentation index than non-smokers (difference=3.7%, P<0.0001). Aortic waveform parameters, controlling for demographics, antihypertensives, diabetes and cardiovascular disease (CVD), were higher in non-Europeans than in Europeans. Further adjustment for brachial BP or lifestyle factors (particularly BMI) reduced many differences but several remained. Despite even further adjustment for mean arterial pressure, pulse rate, height and total:high-density lipoprotein cholesterol, compared with Europeans, South Asians had higher levels of all measured aortic waveform parameters (for example, for backward pressure amplitude: ß=1.5 mm Hg; P<0.0001), whereas Pacific people had 9% higher loge (excess pressure integral) (P<0.0001). In conclusion, aortic waveform parameters varied with ethnicity in line with the greater prevalence of CVD among non-white populations. Generally, this was true even after accounting for brachial BP, suggesting that waveform parameters may have increased usefulness in capturing ethnic variations in cardiovascular risk. Heavy alcohol consumption, smoking and especially BMI may partially contribute to elevated levels of these parameters.


Assuntos
Aorta/fisiopatologia , Doenças Cardiovasculares/etnologia , Análise de Onda de Pulso , Idoso , Idoso de 80 Anos ou mais , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Índice de Massa Corporal , Estudos Transversais , Etnicidade , Feminino , Hemodinâmica/fisiologia , Humanos , Estilo de Vida/etnologia , Masculino , Pessoa de Meia-Idade , Nova Zelândia/epidemiologia , Análise de Onda de Pulso/métodos , Análise de Onda de Pulso/estatística & dados numéricos , Fatores de Risco , Fumar/epidemiologia
5.
Diabetologia ; 56(9): 2021-33, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23760677

RESUMO

AIMS/HYPOTHESIS: We have previously reported a high prevalence of non-alcoholic fatty liver disease (NAFLD) among women with previous gestational diabetes mellitus (pGDM). We wanted to confirm that intrahepatocellular lipid (IHCL) is associated with pGDM independently of adiposity and determine: (1) if VLDL metabolism is dysregulated; and (2) the extent to which NAFLD and IHCL account for the dysmetabolic phenotype in pGDM. METHODS: We analysed data from a cohort of 234 women (114 with pGDM) and identified effects of pGDM on lipid and glucoregulation that were independent of ultrasound-diagnosed NAFLD. We then measured IHCL by MR spectroscopy in a representative subgroup (n = 36) and conducted detailed metabolic studies (IVGTT, VLDL apolipoprotein B [apoB] kinetics and palmitate turnover) and measurement of regional body fat by MRI to demonstrate effects of IHCL that were independent of a history of pGDM. RESULTS: pGDM was associated with increased IHCL (p = 0.04) after adjustment for adiposity. Independently of IHCL, pGDM was associated with a lower IVGTT disposition index (p = 0.02) and acute insulin response to glucose (pGDM+/NAFLD-, 50% lower; pGDM+/NAFLD+, 36% lower; effect of pGDM, p = 0.03), increased VLDL apoB pool size (pGDM+/NAFLD-, 3.1-fold higher; pGDM+/NAFLD+, 1.2-fold higher; effect of pGDM, p = 0.02) and, at borderline significance (p = 0.05), increased rate of VLDL apoB synthesis. CONCLUSIONS/INTERPRETATION: pGDM is associated with increased IHCL independently of adiposity. The increased liver fat contributes to the phenotype, but pGDM status is independently associated with diminished insulin secretion and (shown for the first time) augmented VLDL metabolism. IHCL with pGDM may compound a dysmetabolic phenotype.


Assuntos
Diabetes Gestacional/metabolismo , Insulina/metabolismo , Lipoproteínas VLDL/metabolismo , Fígado/metabolismo , Adulto , Diabetes Mellitus Tipo 2/metabolismo , Fígado Gorduroso/metabolismo , Feminino , Humanos , Resistência à Insulina/fisiologia , Hepatopatia Gordurosa não Alcoólica , Gravidez
6.
Health Technol Assess ; 14(46): 131-172, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20923611

RESUMO

BACKGROUND: Influenza viruses are thought to be spread by droplets, but the role of aerosol dissemination is unclear and has not been assessed by previous studies. Oxygen therapy, nebulised medication and ventilatory support are treatments used in clinical practice to treat influenzal infection are thought to generate droplets or aerosols. OBJECTIVES: Evaluation of the characteristics of droplet/aerosol dispersion around delivery systems during non-invasive ventilation (NIV), oxygen therapy, nebuliser treatment and chest physiotherapy by measuring droplet size, geographical distribution of droplets, decay in droplets over time after the interventions were discontinued. METHODS: Three groups were studied: (1) normal controls, (2) subjects with coryzal symptoms and (3) adult patients with chronic lung disease who were admitted to hospital with an infective exacerbation. Each group received oxygen therapy, NIV using a vented mask system and a modified circuit with non-vented mask and exhalation filter, and nebulised saline. The patient group had a period of standardised chest physiotherapy treatment. Droplet counts in mean diameter size ranges from 0.3 to > 10 µm were measured with an counter placed adjacent to the face and at a 1-m distance from the subject/patient, at the height of the nose/mouth of an average health-care worker. RESULTS: NIV using a vented mask produced droplets in the large size range (> 10 µm) in patients (p = 0.042) and coryzal subjects (p = 0.044) compared with baseline values, but not in normal controls (p = 0.379), but this increase in large droplets was not seen using the NIV circuit modification. Chest physiotherapy produced droplets predominantly of > 10 µm (p = 0.003), which, as with NIV droplet count in the patients, had fallen significantly by 1 m. Oxygen therapy did not increase droplet count in any size range. Nebulised saline delivered droplets in the small- and medium-size aerosol/droplet range, but did not increase large-size droplet count. CONCLUSIONS: NIV and chest physiotherapy are droplet (not aerosol)-generating procedures, producing droplets of > 10 µm in size. Due to their large mass, most fall out on to local surfaces within 1 m. The only device producing an aerosol was the nebuliser and the output profile is consistent with nebuliser characteristics rather than dissemination of large droplets from patients. These findings suggest that health-care workers providing NIV and chest physiotherapy, working within 1 m of an infected patient should have a higher level of respiratory protection, but that infection control measures designed to limit aerosol spread may have less relevance for these procedures. These results may have infection control implications for other airborne infections, such as severe acute respiratory syndrome and tuberculosis, as well as for pandemic influenza infection.


Assuntos
Aerossóis , Surtos de Doenças/prevenção & controle , Vírus da Influenza A Subtipo H1N1 , Influenza Humana/prevenção & controle , Influenza Humana/transmissão , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Intervalos de Confiança , Feminino , Saúde Global , Humanos , Influenza Humana/epidemiologia , Influenza Humana/terapia , Masculino , Pessoa de Meia-Idade , Nebulizadores e Vaporizadores , Oxigenoterapia/efeitos adversos , Oxigenoterapia/métodos , Modalidades de Fisioterapia/efeitos adversos , Doença Pulmonar Obstrutiva Crônica , Respiração Artificial/efeitos adversos , Respiração Artificial/métodos , Risco , Medição de Risco , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave , Adulto Jovem
7.
Eur J Clin Nutr ; 63(11): 1360-7, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19707224

RESUMO

OBJECTIVES: To analyze whether a decreased sensitivity to adrenaline in women with earlier gestational diabetes (GDM) explains the impairment in the thermogenic response to food (=post-prandial thermogenesis (PPT)) that is observed in these women at future risk of obesity and type II diabetes. SUBJECTS/METHODS: Ten normal-weight women with previous GDM and 10 controls matched for body weight, all with normal glucose tolerance, had insulin sensitivity, PPT and the thermogenic response to an adrenaline infusion measured. RESULTS: Insulin sensitivity was similar in the previous GDM compared with control groups: (mean+/-s.e.m.) 29.1+/-3.2 vs 30.9+/-1.6 mg/l/min. The early (0-30 min) PPT response was diminished and delayed in women with previous GDM compared with controls: (10+/-2 vs 15+/-1 kJ, P=0.04); time constant for PPT (median (interquartile range)) (57 (47-79) vs 29 (25-49) min, P=0.01). The overall PPT response and the thermogenic response to adrenaline were not significantly different between the groups. The 30 min and 2 h PPT response correlated positively and significantly with the increment in energy expenditure as a result of the adrenaline infusion (rho=+0.65; P=0.04 and rho=+0.71; P=0.02, respectively) in women with previous GDM only. There was no correlation between adrenaline and insulin sensitivity. CONCLUSIONS: There is no evidence of diminished adrenaline sensitivity but a positive relationship exists between PPT and sensitivity to adrenaline in women with previous GDM. The mechanism is not mediated through insulin resistance. This relationship may predispose these normal-weight at-risk women to future weight gain.


Assuntos
Agonistas Adrenérgicos/farmacologia , Diabetes Mellitus Tipo 2/epidemiologia , Diabetes Gestacional/fisiopatologia , Epinefrina/farmacologia , Termogênese/fisiologia , Adulto , Glicemia/análise , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/etiologia , Diabetes Gestacional/metabolismo , Feminino , Humanos , Insulina/sangue , Insulina/metabolismo , Período Pós-Prandial , Gravidez , Medição de Risco , Fatores de Risco , Termogênese/efeitos dos fármacos , Aumento de Peso
8.
Med Biol Eng Comput ; 47(2): 207-10, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19198913

RESUMO

Both impedance analysis and wave intensity analysis are used to separate measured pressure and flow waveforms into their forward and backward components. The separation is sensitive to the characteristic impedance or wave speed determined from the data. In all other aspects, the results are identical.


Assuntos
Modelos Cardiovasculares , Fluxo Pulsátil/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Interpretação Estatística de Dados , Humanos , Resistência Vascular/fisiologia
9.
Proc Inst Mech Eng H ; 222(4): 403-16, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18595353

RESUMO

Previous studies based on measurements made in the ascending aorta have demonstrated that it can be useful to separate the arterial pressure P into a reservoir pressure P* generated by the windkessel effect and a wave pressure p generated by the arterial waves: P = P*+p. The separation in these studies was relatively straightforward since the flow into the arterial system was measured. In this study the idea is extended to measurements of pressure and velocity at sites distal to the aortic root where flow into the arterial system is not known. P* is calculated from P at an arbitrary location in a large artery by fitting the pressure fall-off in diastole to an exponential function and assuming that p is proportional to the flow into the arterial system. A local reservoir velocity U* that is proportional to P* is also defined. The separation algorithm is applied to in vivo human and canine data and to numerical data generated using a one-dimensional model of pulse wave propagation in the larger conduit arteries. The results show that the proposed algorithm is reasonably robust, allowing for the separation of the measured pressure and velocity into reservoir and wave pressures and velocities. Application to data measured simultaneously in the aorta of the dog shows that the reservoir pressure is fairly uniform along the aorta, a test of self-consistency of the assumptions leading to the algorithm. Application to data generated with a validated numerical model indicates that the parameters derived by fitting the pressure data are close to the known values which were used to generate the numerical data. Finally, application to data measured in the human thoracic aorta indicates the potential usefulness of the separation.


Assuntos
Artérias/fisiologia , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Modelos Cardiovasculares , Fluxo Pulsátil/fisiologia , Animais , Simulação por Computador , Humanos
10.
Artigo em Inglês | MEDLINE | ID: mdl-18002549

RESUMO

The development of a electrochemical tissue perfusion sensor is presented. The sensor is a platinum/platinum ring-disc microelectrode that relies on the principle of collector-generator to monitor mass transport within its vicinity. Tissue perfusion is a mass transport mechanism that describes the movement of respiratory gases, nutrients and metabolites in tissue. The sensor's capability of detecting perfusion at the cellular level in a continuous fashion is unique. This sensor will provide insight into the way nutrients and metabolites are transported in tissue especially in cases were perfusion is low such as in wounds or ischemic tissue. We present experimental work for the development and testing of the sensors in vitro. Experimental flow recordings in free steam solutions as well as the flow through tissue-like media are shown. Tests on post operative human tissue are also presented. The sensor's feature such as the continuous recoding capacities, spatial resolution and the measurement range from ml/min to microl/min are highlighted.


Assuntos
Microeletrodos , Pele/metabolismo , Transporte Biológico , Difusão , Eletroquímica , Humanos , Pele/irrigação sanguínea
11.
Med Biol Eng Comput ; 45(12): 1201-10, 2007 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17710460

RESUMO

In a previous paper we demonstrated that the linear portion of the pressure-velocity loop (PU-loop) corresponding to early systole could be used to calculate the local wave speed. In this paper we extend this work to show that determination of the time at which the PU-loop first deviates from linearity provides a convenient way to determine the arrival time of reflected waves (Tr). We also present a new technique using the PU-loop that allows for the determination of wave speed and Tr simultaneously. We measured pressure and flow in elastic tubes of different diameters, where a strong reflection site existed at known distances away form the measurement site. We also measured pressure and flow in the ascending aorta of 11 anaesthetised dogs where a strong reflection site was produced through total arterial occlusion at four different sites. Wave speed was determined from the initial slope of the PU-loop and Tr was determined using a new algorithm that detects the sampling point at which the initial linear part of the PU-loop deviates from linearity. The results of the new technique for detecting Tr were comparable to those determined using the foot-to-foot and wave intensity analysis methods. In elastic tubes Tr detected using the new algorithm was almost identical to that detected using wave intensity analysis and foot-to-foot methods with a maximum difference of 2%. Tr detected using the PU-loop in vivo highly correlated with that detected using wave intensity analysis (r (2) = 0.83, P < 0.001). We conclude that the new technique described in this paper offers a convenient and objective method for detecting Tr, and allows for the dynamic determination of wave speed and Tr, simultaneously.


Assuntos
Algoritmos , Velocidade do Fluxo Sanguíneo/fisiologia , Pressão Sanguínea/fisiologia , Modelos Cardiovasculares , Animais , Aorta/fisiologia , Cães , Fluxo Pulsátil , Reologia , Pressão Ventricular/fisiologia
12.
Bull Math Biol ; 69(4): 1233-54, 2007 May.
Artigo em Inglês | MEDLINE | ID: mdl-17334872

RESUMO

We present a dynamical model of lipoprotein metabolism derived by combining a cascading process in the blood stream and cellular level regulatory dynamics. We analyse the existence and stability of equilibria and show that this low-dimensional, nonlinear model exhibits bistability between a low and a high cholesterol state. A sensitivity analysis indicates that the intracellular concentration of cholesterol is robust to parametric variations while the plasma cholesterol can vary widely. We show how the dynamical response to time-dependent inputs can be used to diagnose the state of the system. We also establish the connection between parameters in the system and medical and genetic conditions.


Assuntos
Lipoproteínas/metabolismo , Modelos Biológicos , Transporte Biológico , Humanos , Hiperlipoproteinemia Tipo II/metabolismo , Lipase/metabolismo , Lipoproteínas/sangue , Dinâmica não Linear , Doença de Tangier/metabolismo
13.
J Biomech ; 40(8): 1794-805, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17045276

RESUMO

Blood flow in the circle of Willis (CoW) is modelled using the 1-D equations of pressure and flow wave propagation in compliant vessels. The model starts at the left ventricle and includes the largest arteries that supply the CoW. Based on published physiological data, it is able to capture the main features of pulse wave propagation along the aorta, at the brachiocephalic bifurcation and throughout the cerebral arteries. The collateral ability of the complete CoW and its most frequent anatomical variations is studied in normal conditions and after occlusion of a carotid or vertebral artery (VA). Our results suggest that the system does not require collateral pathways through the communicating arteries to adequately perfuse the brain of normal subjects. The communicating arteries become important in cases of missing or occluded vessels, the anterior communicating artery (ACoA) being a more critical collateral pathway than the posterior communicating arteries (PCoAs) if an internal carotid artery (ICA) is occluded. Occlusions of the VAs proved to be far less critical than occlusions of the ICAs. The worst scenario in terms of reduction in the mean cerebral outflows is a CoW without the first segment of an anterior cerebral artery combined with an occlusion of the contralateral ICA. Furthermore, in patients without any severe occlusion of a carotid or VA, the direction of flow measured at the communicating arteries corresponds to the side of the CoW with an absent or occluded artery. Finally, we study the effect of partial occlusions of the communicating arteries on the cerebral flows, which again confirms that the ACoA is a more important collateral pathway than the PCoAs if an ICA is occluded.


Assuntos
Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Circulação Cerebrovascular , Transtornos Cerebrovasculares/fisiopatologia , Círculo Arterial do Cérebro/anormalidades , Círculo Arterial do Cérebro/fisiopatologia , Modelos Cardiovasculares , Animais , Humanos
14.
Comput Methods Biomech Biomed Engin ; 9(6): 353-61, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17145669

RESUMO

Blood flow in the largest arteries of the arm up to the digital arteries is numerically modelled using the one-dimensional equations of pressure and flow wave propagation in compliant vessels. The model can be applied to different anatomies of arterial networks and can simulate compression of arteries, these allowing us to simulate the modified Allen's test (MAT) and to assess its suitability for the detection of sufficient collateral flow in the hand if radial blood supply is interrupted. The test measures blood flow in the superficial palmar arch before and during compression of the radial artery. The absence of reversal flow in the palmar arch with the compression indicates insufficient collateral flow and is referred to as a positive MAT. This study shows that small calibres of the superficial palmar arch and insufficient compression of the radial artery can lead to false-positive results. Measurement of the drop in digital systolic pressures with compression of the radial artery has proved to be a more sensitive test to predict the presence of sufficient ulnar collateral flow in networks with small calibres of the superficial palmar arch. However, this study also shows that digital pressure measurements can fail in detecting enough collateral flow if the radial artery is insufficiently compressed.


Assuntos
Circulação Colateral , Simulação por Computador , Mãos/irrigação sanguínea , Modelos Biológicos , Mãos/fisiologia , Humanos , Artéria Radial/fisiologia
15.
Philos Trans A Math Phys Eng Sci ; 364(1843): 1407-22, 2006 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-16766352

RESUMO

In soft tissues, large molecules such as proteoglycans trapped in the extracellular matrix (ECM) generate high levels of osmotic pressure to counter-balance external pressures. The semi-permeable matrix and fixed negative charges on these molecules serve to promote the swelling of tissues when there is an imbalance of molecular concentrations. Structural molecules, such as collagen fibres, form a network of stretch-resistant matrix, which prevents tissue from over-swelling and keeps tissue integrity. However, collagen makes little contribution to load bearing; the osmotic pressure in the ECM is the main contributor balancing external pressures. Although there have been a number of studies on tissue deformation, there is no rigorous analysis focusing on the contribution of the osmotic pressure in the ECM on the viscoelastic behaviour of soft tissues. Furthermore, most previous works were carried out based on the assumption of infinitesimal deformation, whereas tissue deformation is finite under physiological conditions. In the current study, a simplified mathematical model is proposed. Analytic solutions for solute distribution in the ECM and the free-moving boundary were derived by solving integro-differential equations under constant and dynamic loading conditions. Osmotic pressure in the ECM is found to contribute significantly to the viscoelastic characteristics of soft tissues during their deformation.


Assuntos
Tecido Conjuntivo/fisiologia , Proteínas da Matriz Extracelular/fisiologia , Matriz Extracelular/fisiologia , Mecanotransdução Celular/fisiologia , Modelos Biológicos , Equilíbrio Hidroeletrolítico/fisiologia , Animais , Simulação por Computador , Elasticidade , Humanos , Pressão Osmótica , Estresse Mecânico , Viscosidade
16.
Conf Proc IEEE Eng Med Biol Soc ; 2006: 867-70, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17946867

RESUMO

Pulse wave velocity is related to arterial stiffness. Pulse wave velocity changes with age and disease and is a useful indicator of cardiovascular disease. Different methods are used for evaluating pulse wave velocity in systemic vessels, but none is applicable to coronary arteries. In this study we first compare values of wave speed (c) calculated from measurements of pressure (P) and velocity (U) using different analytical methods: PU-loop, beta stiffness parameter, characteristic impedance, foot-to-foot method, and the sum of squares (Sigma(2)), a novel way of calculating the wave speed (calculated from the square root of the sum of the ratio of the dP(2) and dU(2) over a complete cardiac cycle). Results from human measurements using Doppler ultrasound on carotid arteries show good correlation between the PU-loop method, beta stiffness parameter and Sigma(2). Characteristic impedance calculations show the greatest variation of all methods. The Sigma(2) method was further assessed in vitro for use in coronary vessels. Pressure and velocity measurements were obtained from human coronary arteries following angiographic studies. The measurements were made invasively by co-locating two wires with pressure and velocity transducers. Pressure and velocity data in the left anterior descending, circumflex, left main stem and right coronary arteries were acquired simultaneously along with the ECG signal. Wave speed was calculated using Sigma(2). Wave intensity analysis was used to determine forward and backward traveling waves at different times in different locations, for which wave speed, approximate distance and timings between waves need to be known.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Determinação da Pressão Arterial/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/fisiologia , Diagnóstico por Computador/métodos , Modelos Cardiovasculares , Fluxo Pulsátil/fisiologia , Adulto , Simulação por Computador , Humanos , Masculino , Ultrassonografia
17.
J Biomech ; 38(4): 647-55, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15713284

RESUMO

We examine the effects of arterial occlusion on the pressure, velocity and the reflected waves in the ascending aorta using wave intensity analysis. In 11 anaesthetised, open-chested dogs, snares were used to produce total arterial occlusion at 4 sites: the upper descending aorta at the level of the aortic valve (thoracic); the lower thoracic aorta at the level of the diaphragm (diaphragm); the abdominal aorta between the renal arteries (abdominal) and the left iliac artery, 2 cm downstream from the aorta iliac bifurcation (iliac). Pressure and flow in the ascending aorta were measured, and data were collected before and during the occlusion. During thoracic and diaphragm occlusions a significant increase in mean aortic pressure (46% and 23%) and in wave speed (25% and 10%) was observed, while mean flow rate decreased significantly (23% and 17%). Also, the reflected compression wave arrived significantly earlier (45% and 15%) and its peak intensity was significantly greater (257% and 125%), all compared with control. Aortic occlusion distal to the renal arteries, however, caused an indiscernible change in the pressure and velocity waveforms, and in the intensities and timing of the waves in the forward and backward directions. The measured pressure and velocity waveforms are the result of the interaction between the heart and the arterial system. The separated pressure, velocity and wave intensity are required to provide information about arterial hemodynamic such as the timing and magnitude of the forward and backward waves. The net wave intensity is simpler to calculate but provides information only about the predominant direction of the waves and can be misleading when forward and backward waves of comparable magnitudes are present simultaneously.


Assuntos
Aorta/fisiologia , Arteriopatias Oclusivas/fisiopatologia , Animais , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Cães , Hemorreologia , Modelos Cardiovasculares , Oscilometria
18.
Am J Physiol Heart Circ Physiol ; 289(1): H270-6, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15722409

RESUMO

The study of wave propagation at different points in the arterial circulation may provide useful information regarding ventriculoarterial interactions. We describe a number of hemodynamic parameters in the carotid, brachial, and radial arteries of normal subjects by using noninvasive techniques and wave-intensity analysis (WIA). Twenty-one normal adult subjects (14 men and 7 women, mean age 44 +/- 6 yr) underwent applanation tonometry and pulsed-wave Doppler studies of the right common carotid, brachial, and radial arteries. After ensemble averaging of the pressure and flow-velocity data, local hydraulic work was determined and a pressure-flow velocity loop was used to determine local wave speed. WIA was then applied to determine the magnitude, timings, and energies of individual waves. At all sites, forward-traveling (S) and backward-traveling (R) compression waves were observed in early systole. In mid- and late systole, forward-traveling expansion waves (X and D) were also seen. Wave speed was significantly higher in the brachial (6.97 +/- 0.58 m/s) and radial (6.78 +/- 0.62 m/s) arteries compared with the carotid artery (5.40 +/- 0.34 m/s; P < 0.05). S-wave energy was greatest in the brachial artery (993.5 +/- 87.8 mJ/m2), but R-wave energy was greatest in the radial artery (176.9 +/- 19.9 mJ/m2). X-wave energy was significantly higher in the brachial and radial arteries (176.4 +/- 32.7 and 163.2 +/- 30.5 mJ/m2, respectively) compared with the carotid artery (41.0 +/- 9.4 mJ/m2; P < 0.001). WIA illustrates important differences in wave patterns between peripheral arteries and may provide a method for understanding ventriculo-arterial interactions in the time domain.


Assuntos
Pressão Sanguínea , Artéria Braquial/fisiologia , Artéria Carótida Primitiva/fisiologia , Artéria Radial/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo , Artéria Braquial/diagnóstico por imagem , Artéria Carótida Primitiva/diagnóstico por imagem , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Radial/diagnóstico por imagem , Fluxo Sanguíneo Regional , Ultrassonografia
20.
J Biomech ; 37(4): 457-70, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-14996557

RESUMO

The propagation of the arterial pulse wave in the large systemic arteries has been calculated using a linearised method of characteristics analysis to follow the waves generated by the heart. The model includes anatomical and physiological data for the 55 largest arteries adjusted so that the bifurcating tree of arteries is well matched for forward travelling waves. The peripheral arteries in the model are terminated by resistance elements which are adjusted to produce a physiologically reasonable distribution of mean blood flow. In the model, the pressure and velocity wave generated by the contraction of the left ventricle propagates to the periphery where it is reflected. These reflected waves are re-reflected by each of the bifurcations that they encounter and a very complex pattern of waves is generated. The results of the calculations exhibit many of the features of the systemic arteries, including the increase of the pulse pressure with distance away from the heart as well as the initial decrease and then the large increase in the magnitude of back flow during late systole going from the ascending aorta to the abdominal aorta to the arteries of the leg. The model is then used to study the effects of the reflection or absorption of waves by the heart and the mechanisms leading to the incisura are investigated. Calculations are carried out with the total occlusion of different arterial segments in order to model experiments in which the effects of the occlusion of different arteries on pressure and flow in the ascending aorta were measured. Finally, the effects of changes in peripheral resistance on pressure and velocity waveforms are also studied. We conclude from these calculations that the complex pattern of wave propagation in the large arteries may be the most important determinant of arterial haemodynamics.


Assuntos
Artérias/fisiologia , Modelos Cardiovasculares , Pulso Arterial , Aorta/fisiologia , Aorta Abdominal/fisiologia , Doenças da Aorta/fisiopatologia , Arteriopatias Oclusivas/fisiopatologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Vasos Coronários/fisiologia , Diástole , Coração/fisiologia , Hemodinâmica , Humanos , Perna (Membro)/irrigação sanguínea , Fluxo Sanguíneo Regional , Sístole , Resistência Vascular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA