Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 117
Filtrar
1.
Orthop Traumatol Surg Res ; 110(2): 103739, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37918693

RESUMO

BACKGROUND: Porous tantalum components and augments have demonstrated short to midterm fixation stability in acetabular total hip arthroplasty (THA) revision but do not offer a novel option to decrease the postoperative dislocation rate. Recently, dual mobility (DM) cups have gained interest to decrease the prevalence of recurrent hip instability after revision hip arthroplasty, but this issue was not confirmed combined with use of tantalum reconstruction devices. Therefore, we did a retrospective study aiming to: (1) evaluate at a 5-year minimum follow-up period the dislocation rate (and other intra- and postoperative complications), (2) assess radiographic results specifically looking at osseointegration and restoration of the hip center, (3) and also clinical results in a cohort of patients who underwent complex acetabular reconstruction with trabecular metal revision components associated with a cemented DM socket. HYPOTHESIS: Using a DM socket cemented in porous tantalum components can reach the low risk of hip dislocation reported with DM components in revision setting without increasing the risk of a mechanical failure. METHODS: A cross-sectional study identified 174 THA revision including an acetabular revision. Were excluded 118 revisions with acetabular defects Type 1, 2a or 2B according to Paprosky's classification, as well as 18 hips revised without a dual mobility and 3 patients (3 hips) lost to follow-up. Were thus included in this study 35 hips (35 patients) implanted with uncemented total hip arthroplasty revision using both trabecular metal acetabular cup-cage reconstruction and a cemented DM cup. Seven hips were classified Paprosky types 2C, 15 type 3A and 13 types 3B. Patients were followed with clinical and radiological evaluation regarding dislocation rate, infection, reoperation or re-revision, osseointegration and restoration of the hip center, and functional results according to the Harris hip score and psoas impingement presence. RESULTS: At a mean follow-up of 8.1±1.8 years (5.1-12.6), one dislocation was recorded, and one acute deep infection. No patient required a cup re-revision for septic or aseptic loosening. The survivorship at 8years regarding revision for any cause as an endpoint was 96.5% (CI95%: 92-99). Osseointegration of TM implants was analyzed and found no acetabular migration at the last follow-up in the cohort. The mean hip center position was optimized from 48±7mm (37-58) to 34±5mm (29-39) vertically and from 26±5mm (-18-36) to 24±8mm (7-31) horizontally without reaching significance (p=0.1). On the last follow-up X-rays, the mean acetabular inclination was 47̊±9̊ (32̊-61̊). According to the criteria of Hirakawa, 97.1% (34/35) of the hip centers were restored. One cup (2.9%) was more than 5mm proximally from the hip center, and none more than 10mm. Clinical results assessed a Harris Hip Score improved from 36±17 (23-62) preoperatively to 82±15 (69-93) at last follow-up (p<0.0001). Two patients (2/35, 5.7%) complained of psoas impingement. CONCLUSION: This study suggests effectiveness of DM cups in association with a tantalum-made acetabular shell for reconstruction of large bone defect in THRs for both solving postoperative instability and aseptic loosening without increasing the re-revision rate for any reason in a midterm follow-up. LEVEL OF EVIDENCE: IV; observational study.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Tantálio , Estudos Retrospectivos , Estudos Transversais , Seguimentos , Falha de Prótese , Desenho de Prótese , Artroplastia de Quadril/métodos , Acetábulo/cirurgia , Reoperação/métodos
2.
Healthcare (Basel) ; 11(18)2023 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-37761713

RESUMO

The COVID-19 pandemic highlighted the need for efficient use of hospital infrastructure. The hypothesis was that a rapid shift to outpatient surgery after hip or knee arthroplasty could be implemented without compromising quality of care. The aim of this study was to assess the safety, pain management and patient-reported outcomes before and after the implementation of an accelerated discharge program using a digital follow-up tool. A retrospective cohort design was used to compare 97 patients who received primary total hip or knee arthroplasty during the pandemic (early discharge) to comparable 194 pre-pandemic patients (normal discharge). Both cohorts had the same inclusion criteria and were closely monitored using the digital follow-up tool. The accelerated discharge program reduced length of stay from a median of 3 days (before the pandemic) to a median of 1 day (during the pandemic) (p < 0.001). The complication rate of 2% was the same for both groups (p > 0.05). Patient-reported outcomes for matched samples of hip (n = 100) and knee (n = 82) arthroplasty patients were similar before, at 6 weeks and 3 months after surgery for both groups (p > 0.05). There were no differences in pain and medication consumption for the first 6 weeks (p > 0.05). This study demonstrates that reducing length of stay from three to one night after total knee or hip arthroplasty, with the help of a digital follow-up tool, results in a stable rate of complications, readmission, and comparable clinical outcomes, while reducing the socio-economic burden on the health system.

3.
J Pers Med ; 13(5)2023 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-37240994

RESUMO

Rehabilitation for total knee replacement (TKA) often involves in-person therapy sessions, which can be time consuming and costly. Digital rehabilitation has the potential to address these limitations, but most of these systems offer standardized protocols without considering the patient's pain, participation, and speed of recovery. Furthermore, most digital systems lack human support in case of need. The aim of this study was to investigate the engagement, safety, and clinical effectiveness of a personalized and adaptative app-based human-supported digital monitoring and rehabilitation program. In this prospective multi-center longitudinal cohort study, 127 patients were included. Undesired events were managed through a smart alert system. Doctors were triggered when there was a suspicion of problems. The drop-out rate, complications and readmissions, PROMS, and satisfaction were collected through the app. There was only 2% readmission. Doctor actions through the platform potentially avoided 57 consultations (85% of alerts). The adherence to the program was 77%, and 89% of the patients would recommend the use of the program. Personalized human-backed-up digital solutions can help to improve the rehabilitation journey of patients after TKA, lower healthcare-related costs by lowering the complication and readmission rate, and improve patient reported outcomes.

4.
J Pers Med ; 13(5)2023 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-37241025

RESUMO

The extramedullary guides for the tibial resection during medial unicompartmental knee arthroplasty (UKA) are inaccurate, with an error risk in coronal and sagittal planes and cut thickness. It was our hypothesis that the use of anatomical landmarks for the tibial cut can help the surgeon to improve accuracy. The technique described in this paper is based on the use of a simple and reproducible anatomical landmark. This landmark is the line of insertion of the fibers of the deep medial collateral ligament (MCL) around the anterior half of the medial tibial plateau called the "Deep MCL insertion line". The used anatomical landmark determines the orientation (in the coronal and sagittal planes) and the thickness of the tibial cut. This landmark corresponds to the line of insertion of the fibers of the deep MCL around the anterior half of the medial tibial plateau. A consecutive series of patients who underwent primary medial UKA between 2019 and 2021 were retrospectively reviewed. A total of 50 UKA were included. The mean age at the time of surgery was 54.5 ± 6.6 years (44-79). The radiographic measurements showed very good to excellent intra-observer and inter-observer agreements. The limb and implant alignments and the tibial positioning were satisfying, with a low rate of outliers and good restoration of the native anatomy. The landmark of the insertion of deep MCL constitutes a reliable and reproducible reference for the tibial cut axis and thickness during medial UKA, independent of the wear severity.

5.
Bone Jt Open ; 4(4): 262-272, 2023 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-37051842

RESUMO

The impact of a diaphyseal femoral deformity on knee alignment varies according to its severity and localization. The aims of this study were to determine a method of assessing the impact of diaphyseal femoral deformities on knee alignment for the varus knee, and to evaluate the reliability and the reproducibility of this method in a large cohort of osteoarthritic patients. All patients who underwent a knee arthroplasty from 2019 to 2021 were included. Exclusion criteria were genu valgus, flexion contracture (> 5°), previous femoral osteotomy or fracture, total hip arthroplasty, and femoral rotational disorder. A total of 205 patients met the inclusion criteria. The mean age was 62.2 years (SD 8.4). The mean BMI was 33.1 kg/m2 (SD 5.5). The radiological measurements were performed twice by two independent reviewers, and included hip knee ankle (HKA) angle, mechanical medial distal femoral angle (mMDFA), anatomical medial distal femoral angle (aMDFA), femoral neck shaft angle (NSA), femoral bowing angle (FBow), the distance between the knee centre and the top of the FBow (DK), and the angle representing the FBow impact on the knee (C'KS angle). The FBow impact on the mMDFA can be measured by the C'KS angle. The C'KS angle took the localization (length DK) and the importance (FBow angle) of the FBow into consideration. The mean FBow angle was 4.4° (SD 2.4; 0 to 12.5). The mean C'KS angle was 1.8° (SD 1.1; 0 to 5.8). Overall, 84 knees (41%) had a severe FBow (> 5°). The radiological measurements showed very good to excellent intraobserver and interobserver agreements. The C'KS increased significantly when the length DK decreased and the FBow angle increased (p < 0.001). The impact of the diaphyseal femoral deformity on the mechanical femoral axis is measured by the C'KS angle, a reliable and reproducible measurement.

6.
Orthop Traumatol Surg Res ; 109(4): 103577, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36754168

RESUMO

BACKGROUND: Return to sport after Knee Arthroplasty has been investigated reporting modifications in the physical activities with a trend towards to lower impact sports after Unicompartemental Knee Arthroplasty. The purpose of this study was to analyze the return to sport level after medial unicompartmental knee arthroplasty (MUKA) in a population of osteoarthritic patients having practiced impact sport, defined with a University of California at Los Angeles activity scale (UCLA)≥9 in their pre-symptomatic arthritic period. HYPOTHESIS: Return to an impact sport after MUKA was possible for a population of osteoarthritic patients having practiced impact sport in their pre-symptomatic arthritic period. METHODS: Ninety-two MUKA with a pre-symptomatic arthritic UCLA score≥9, including 60 men (65.2%) and operated between January 2009 and September 2014, were evaluated by a dedicated survey. Informations were obtained concerning the physical activities (intensity, frequency, kind of sport, reasons to decrease or stop the physical activities in the pre- and the postoperative period). The average age was 64.9 years±6.4 (range 49-74.4). Three different periods were compared: pre-symptomatic arthritic, preoperative and postoperative period. The mean follow-up was 7.3±1.7 years. RESULTS: The mean pre-symptomatic arthritic UCLA score was 9.9±0.3, the mean preoperative UCLA score was 7.0±2.5 (2-10) and the mean postoperative UCLA score was 7.2±2.0 (3-10). There were significant differences for the mean UCLA score values between pre-symptomatic arthritis and postoperative UCLA scores (p=0.034), however no difference was detected in mean score values before and after surgery (p=0.09). Only 32.6% (30/92) of patients had a postoperative UCLA score≥9. For patients practicing an impact sport activity (UCLA≥9) in the preoperative period (23/92; 25%), the postoperative UCLA score was at 8±1.1 (range 4-10). In this subgroup, 47.8% (11/23) of patients had a postoperative UCLA score≥9. The decline in sports in postoperative was predominantly explained by residual pain of the operated knee (31/92; 34%), precaution to not damage the prosthesis (25/92; 27%) and restrictions due to another joint (19/92; 21%). DISCUSSION: Return to impact sport after MUKA seems to be limited to a restrained number of patients. The main reasons to the decline in sporting activity level are linked to the residual pain of the operated knee and the precaution to not damage the prosthesis. LEVEL OF EVIDENCE: IV, retrospective cohort study.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Esportes , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Volta ao Esporte , Resultado do Tratamento
7.
Arch Orthop Trauma Surg ; 143(3): 1599-1609, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35536354

RESUMO

INTRODUCTION: To our knowledge, no papers have reported the results of robotic-assisted surgery for sequential bilateral Total Knee Arthroplasty (TKA). Indeed, sequential bilateral TKA present several benefits, as one single anesthesia, surgical episode, hospitalization, and rehabilitation. The purpose of our study was to evaluate peri-operative outcomes and compare the complication rates, clinical outcomes, and implant positioning of sequential bilateral TKA performed with a robotic-assisted system versus a conventional technique. MATERIALS AND METHODS: All patients who underwent a sequential bilateral robotic-assisted primary TKA (raTKA) in our institution between November 2019 and February 2021 were included. Twenty patients met the inclusion criteria and were matched with 20 sequential bilateral TKA performed with a conventional technique. The two groups were comparable for the demographic data and the preoperative parameters, including preoperative anticoagulation and ASA score. The minimum follow-up was 6 months. RESULTS: The operative time was significantly longer in the robotic group (< 0.0001), with a mean additional time of 29 min. There was no significant difference between both groups for postoperative blood loss, rate of blood transfusion, or postoperative pain. The average length of stay was 5 days. There was one early complication in the robotic group due to the tibial trackers. The functional outcomes were similar between both groups, except for the functional KSS score, which was better at 6 months in the robotic group (p < 0.0001). The restoration of the knee alignment and the distal femoral anatomy were significantly better in the robotic group than in the conventional group. CONCLUSIONS: Despite a longer operative time, the peri-operative parameters of sequential bilateral TKA were similar between robotic and conventional techniques. Further, sequential bilateral raTKA was at least as safe as a conventional technique, without additional risk of medical complications.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Projetos Piloto , Articulação do Joelho/cirurgia , Dor Pós-Operatória , Osteoartrite do Joelho/cirurgia
8.
Knee Surg Sports Traumatol Arthrosc ; 31(4): 1334-1346, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35552475

RESUMO

PURPOSE: An anatomo-functional implant positioning (AFIP) technique in total knee arthroplasty (TKA) could restore physiological ligament balance (symmetric gap in extension, asymmetric gap in flexion). The purposes were to compare (1) ligament balancing in extension and flexion after TKA in the AFIP group, (2) TKA alignment, implant positioning and patellar tracking between AFIP and adjusted mechanical alignment (aMA) techniques, (3) clinical outcomes between both groups at 12 months. METHODS: All robotic-assisted TKA with an AFIP technique were included (n = 40). Exclusion criteria were genu valgum (HKA angle > 183°), extra-articular deformity more than 10°, and patellar maltracking (high-grade J-sign). One control patient with a TKA implanted by an aMA technique was matched for each case, based on age, body mass index, sex, and knee alignment. Ligament balancing (medial and lateral gaps in millimeters) in full extension and at 90° of flexion after TKA in the AFIP group was assessed with the robotic system. TKA alignment (HKA angle), implants positioning (femoral and tibial coronal axis, tibial slope, joint-line orientation), patellar tracking (patellar tilt and translation) and the Knee Society Score (KSS) at 6 and 12 months were compared between both groups. The ligament balancing was compared using a t test for paired samples in the AFIP group. The radiographic measurements and KSS scores were compared between groups using a t test for independent samples. RESULTS: In the AFIP group, there was no significant difference between the medial and lateral gap laxity in extension (NS). A significant opening of the lateral gap was observed in flexion compared to extension (mean: + 2.9 mm; p < 0.0001). The mean postoperative HKA angle was comparable between both groups (177.3° ± 2.1 in the AFIP group vs 176.8° ± 3.2; NS). In the AFIP group, the femoral anatomy was restored (90.9° ± 1.6) and the tibial varus was partially corrected (87.4° ± 1.8). The improvement of Knee and Function KSS at 6 months was better in the AFIP group (59.3 ± 11.9 and 51.7 ± 20, respectively, versus 49.3 ± 9.7 and 20.8 ± 13; p < 0.001). CONCLUSION: The AFIP concept allowed the restoration of the native knee alignment and a natural functional ligament pattern. With a more physiological target for ligament balancing, the AFIP technique had equivalent clinical outcomes at 12 months compared to aMA, with a faster recovery. LEVEL OF EVIDENCE: III retrospective therapeutic case control series.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Osteoartrite do Joelho/cirurgia , Articulação do Joelho/cirurgia , Ligamentos/cirurgia , Amplitude de Movimento Articular/fisiologia
9.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 814-821, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34557949

RESUMO

PURPOSE: The purpose of this study was to evaluate: (1) improvement of functional and quality of life scores, (2) adverse events, (3) short-term implants survivorship of a newly designed fixed-bearing partial knee replacement (PKR) with a morphometric tibial tray in a large and multicentric population at a minimum follow-up of 2 years. METHODS: From 2017 to 2019, 479 medial PKR were implanted by 16 non-developing surgeons from United States, Europe, and Japan. Eight patients were lost to follow-up (1.8%). Standardized follow-up procedures included patient-reported outcomes (Oxford Knee Society score, Forgotten Joint Score, EQ VAS, EQ 5D), patient satisfaction, radiographic assessments, adverse event at 2 years. Comparisons between the preoperative and postoperative values were performed using Student t test. Kaplan-Meier survivorship analysis was performed with knee revision as the endpoint. RESULTS: The mean age was 65.6 ± 9.6 years. Mean body mass index was 29.5 ± 5.1 kg/m2. Oxford Knee Society score and Forgotten Joint Score, respectively, improved from 23.7 ± 8 and 16 ± 15.8 preoperatively to 42.4 ± 6.5 and 74 ± 24.9 at 2 years (p < 0.0001). Satisfaction Score was 92.3 ± 13.4 at 2 years. Ten re-operations (2.1%) were reported including seven implant removals (1.5%). No other adverse event was reported. The causes of conversion to total knee arthroplasty were: nickel allergy (n = 2), patellofemoral osteoarthritis (n = 1), pain (n = 1), deep infection (n = 3). Two re-operations were performed due to infection, and one for internal fixation for a tibial plateau fracture. The 2-year Kaplan-Meier survival estimate was 98.4%, with implant removals as the endpoint. CONCLUSION: This prospective multicentric study reported safe and reliable clinical outcomes of a morphometric PKR, which optimized tibial coverage and femoral fit, in a large population of patients worldwide at 2 years. LEVEL OF EVIDENCE: Prospective cohort study-therapeutic study, Level II.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Pessoa de Meia-Idade , Idoso , Artroplastia do Joelho/métodos , Estudos Prospectivos , Prótese do Joelho/efeitos adversos , Qualidade de Vida , Resultado do Tratamento , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Reoperação , Seguimentos , Estudos Retrospectivos
10.
Int Orthop ; 47(2): 485-494, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36508053

RESUMO

PURPOSE: To evaluate the feasibility of using a smartphone-based care management platform (sbCMP) and robotic-assisted total knee arthroplasty (raTKA) to collect data throughout the episode-of-care and assess if intra-operative measures of soft tissue laxity in raTKA were associated with post-operative outcomes. METHODS: A secondary data analysis of 131 patients in a commercial database who underwent raTKA was performed. Pre-operative through six week post-operative step counts and KOOS JR scores were collected and cross-referenced with intra-operative laxity measures. A Kruskal-Wallis test or a Wilcoxon sign-rank was used to assess outcomes. RESULTS: There were higher step counts at six weeks post-operatively in knees with increased laxity in both the lateral compartment in extension and medial compartment in flexion (p < 0.05). Knees balanced in flexion within < 0.5 mm had higher KOOS JR scores at six weeks post-operative (p = 0.034) compared to knees balanced within 0.5-1.5 mm. CONCLUSION: A smartphone-based care management platform can be integrated with raTKA to passively collect data throughout the episode-of-care. Associations between intra-operative decisions regarding laxity and post-operative outcomes were identified. However, more robust analysis is needed to evaluate these associations and ensure clinical relevance to guide machine learning algorithms.


Assuntos
Artroplastia do Joelho , Ortopedia , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Smartphone , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia
11.
Arthroplast Today ; 16: 151-157, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35769767

RESUMO

Background: A new morphometric fixed-bearing unicompartmental knee arthroplasty (UKA) system has been introduced to address the anatomical patient-specific challenges. It was our hypothesis that accurate restoration of the patient-specific anatomy would restore normal knee kinematics after UKA. Therefore, we aimed in this cadaveric study to analyze the impact of a medial morphometric UKA on (1) the varus-valgus and anterior-posterior stability of the knee, (2) the knee kinematics during standardized activities of the daily living, and (3) the patellar tracking, measured using a dedicated robotic testing protocol. Methods: Eight human knee specimens underwent full-leg computed tomography CT scanning and comprehensive robotic assessments of tibiofemoral and patellofemoral kinematics. Specimens were tested in the intact state and after implantation of a fixed-bearing medial UKA. Assessments included passive flexion, laxity testing and simulations of level walking, lunge, and stair descent. Results: Medial and lateral joint laxity after UKA closely resembled intact laxity across the full arc of flexion. Anterior-posterior envelope of motion showed a close match between the intact and UKA groups. Net rollback and average laxity were both not statistically different. Simulation of activities of daily living showed a close match in the anterior-posterior motion profile between the medial condyle and lateral condyle. Patellar tilt and medial-lateral shift during knee flexion matched closely between groups. Conclusion: Functional assessment of this UKA system shows nearly identical behavior to the intact knee. Fixed-bearing UKA with morphometric, compartment-specific geometry and precise mechanical instrumentation replicates complex knee balance and kinematics.

12.
Arthroplasty ; 4(1): 17, 2022 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-35491420

RESUMO

BACKGROUND: Artificial intelligence (AI) is defined as the study of algorithms that allow machines to reason and perform cognitive functions such as problem-solving, objects, images, word recognition, and decision-making. This study aimed to review the published articles and the comprehensive clinical relevance of AI-based tools used before, during, and after knee arthroplasty. METHODS: The search was conducted through PubMed, EMBASE, and MEDLINE databases from 2000 to 2021 using the 2009 Preferred Reporting Items for Systematic Reviews and Meta-Analyses Protocol (PRISMA). RESULTS: A total of 731 potential articles were reviewed, and 132 were included based on the inclusion criteria and exclusion criteria. Some steps of the knee arthroplasty procedure were assisted and improved by using AI-based tools. Before surgery, machine learning was used to aid surgeons in optimizing decision-making. During surgery, the robotic-assisted systems improved the accuracy of knee alignment, implant positioning, and ligamentous balance. After surgery, remote patient monitoring platforms helped to capture patients' functional data. CONCLUSION: In knee arthroplasty, the AI-based tools improve the decision-making process, surgical planning, accuracy, and repeatability of surgical procedures.

13.
Arch Orthop Trauma Surg ; 141(12): 2027-2034, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34259929

RESUMO

PURPOSE: Most opponents of assistive technologies in orthopedic surgery consider them as a marketing ruse or fashion. Our hypothesis was that many innovations in modern knee arthroplasty are not following the Scott Parabola. This parabola represents the visual curve of a procedure or therapy showing great promise at the beginning, becoming the standard treatment after reports of encouraging results, only to fall into disuse due to adverse outcome reports. This study aimed to assess the interest in these assistive technologies by (1) their number of publications/year and (2) their actual surgical use reported in the National Joint Registries. METHODS: The search was performed through PubMed, EMBASE, and MEDLINE databases from 1997 to 2021 inclusive to identify all available literature that described the use and results of assistive technologies or new surgical techniques in knee arthroplasty. In the Australian and Norwegian registries, the number of cases performed with these techniques in knee arthroplasty has been quantified year by year. RESULTS: Following the initial online search, a total of 4085 articles was found. After the assessment mentioned above, 2106 articles were included in the study. The orthopedic techniques assessed in this study are not following the "Scott's parabola" in the literature. Computer-assisted knee arthroplasty and patient-specific instrumentation have increased quickly to have reached a plateau, with a stable number of publications over the last 6 years. The number of publications concerning robotic surgery, accelerometers and sensors continue to rise. In the Australian registry, the proportion of primary TKA performed by computer-assisted systems increased from 2.4% in 2003 to 32% in 2019. In the Norwegian registry, the proportion of computer-assisted TKA remained between 8 and 12% of primary TKA since 2007. CONCLUSION: Most of the innovations in modern knee arthroplasty are not following the Scott Parabola. After a fast rise, these techniques do not disappear but continue to evolve. Their evolution is synergistic, and techniques appeared to be linked to each other's. Despite persisting concerns about the cost-efficiency of assisting technologies in knee arthroplasties, the interest and use do not decrease and seems to be directly linked to an exponential increase in interest for a better understanding of alignment targets and improved functional recovery.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Tecnologia Assistiva , Austrália , Humanos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Sistema de Registros , Resultado do Tratamento
14.
Arch Orthop Trauma Surg ; 141(12): 2049-2058, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34255173

RESUMO

INTRODUCTION: The ROSA (Robotic Surgical Assistant) Knee system (Zimmer Biomet, Warsaw, IN) for total knee arthroplasty (TKA) can be considered as collaborative robotics, where the surgeon remains in charge of the procedure and collaborates with a smart robotic tool, to perform the surgery with a high accuracy and reproducibility. The aim was to describe: (1) its concept and surgical technique; (2) its advantages and potential limits; (3) the early experience with this system. MATERIALS AND METHODS: The goal during its development phase was to keep the surgeon active and at the center of the operation: the surgeon handles the saw and performs the cuts while the robotic arm places and holds the guide at the right place. The ROSA knee platform assists the surgeon for the distal femoral cut, the femoral component sizing and positioning, the tibial cut and the ligament balance. This robotic system has two options: image-based with 3D virtual model; or image-less, based on intraoperative landmarks acquisition. All the classic surgical techniques can be used: measured resection, gap balancing, functional alignment, kinematic alignment. Some techniques recently developed are more ROSA-specific: Robotic personalized TKA, ROSA-FuZion technique. RESULTS: Its advantages as compared to other available systems include: radiographs in standing position, collaborative robotic system where the robot completes the surgeon skills, "off-the-shelf" implants, predictive robotic with concept of machine learning incorporated into the system. Two cadaveric studies have reported the high accuracy and reproducibility of this device. This robotic system is recent and currently no clinical series has enough follow-up to report clinical outcomes. CONCLUSION: The ROSA knee system is a robotically assisted semi-autonomous surgical system with some specific characteristics. The aim of this collaborative robotic system is to improve the accuracy and reliability of the bone resections and the ligament balancing, without replacing the steps well performed by the surgeon.


Assuntos
Artroplastia do Joelho , Procedimentos Cirúrgicos Robóticos , Rosa , Humanos , Articulação do Joelho/cirurgia , Reprodutibilidade dos Testes
15.
Orthop J Sports Med ; 9(5): 23259671211003590, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33997078

RESUMO

BACKGROUND: Residual rotatory knee laxity at midterm follow-up after isolated anterior cruciate ligament reconstruction (ACLR) versus ACLR with lateral extra-articular tenodesis (LET) remains an issue. PURPOSE/HYPOTHESIS: To evaluate the outcomes of ACLR with or without additional LET at a minimum 2-year follow-up in patients with preoperative high-grade pivot shift (PS). Our hypothesis was that the addition of LET would decrease the risk of secondary meniscal injury and the presence of residual high-grade PS at follow-up. STUDY DESIGN: Cohort study; Level of evidence, 3. METHODS: A retrospective analysis performed at 3 sports medicine centers identified 266 study patients; all had a high-grade PS (grade 2 or 3) preoperatively and underwent isolated ACLR with or without LET. Four different ACLR techniques were used: single-strand quadrupled semitendinosus (ST4) ACLR without LET (ST4 group; n = 55), ST4 with anatomic LET (ST4+LET group; n = 77), bone-patellar tendon and modified Lemaire LET (BTB+LET group; n = 43), and quadriceps tendon and modified Lemaire LET (QT+LET group; n = 91). At follow-up, we evaluated for the presence of high-grade (grade ≥2) PS. Preoperative meniscal tears and their treatment were recorded. RESULTS: Overall, 185 (69.5%) patients had at least 1 meniscal tear at index surgery. The mean follow-up period was 44.3 months; 47 (17.7%) patients had a new meniscal tear and 64 (24%) patients had a high-grade PS at follow-up. Compared with meniscal repair, significant predictors for high-grade PS at follow-up were meniscectomy (odds ratio [OR] = 2.65 [95% CI, 1.19-5.63]; P = .02) and nonrepair of preoperative meniscal tear (OR = 3.26 [95% CI, 1.27-9.43]; P = .007). The appearance of a new symptomatic meniscal tear was the strongest significant predictor of high-grade PS at follow-up (OR = 4.31 [95% CI, 2.31-8.06]; P < .001). No significant correlation was observed between the addition of LET and the presence of high-grade PS at follow-up. CONCLUSION: In the current study, 1 in 4 patients with high-grade PS before ACLR with or without LET was at risk of residual rotatory knee laxity at mean 44-month follow-up, regardless of the technique used. Repairing a pre-existing meniscal lesion was more effective than performing LET to decrease the presence of a high-grade PS at follow-up.

16.
SICOT J ; 7: 19, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33812467

RESUMO

Traditionally in total knee arthroplasty (TKA), a post-operative neutral alignment was the gold standard. This principle has been contested as functional outcomes were found to be inconsistent. Analysis of limb alignment in the non-osteoarthritic population reveals variations from neutral alignment and consideration of a personalized or patient-specific alignment in TKA is challenging previous concepts. The aim of this review was to clarify the variations of current personalized alignments and to report their results. Current personalized approaches of alignment reported are: kinematic, inverse kinematic, restricted kinematic, and functional. The principle of "kinematic alignment" is knee resurfacing with restitution of pre-arthritic anatomy. The aim is to resurface the femur maintaining the native femoral joint line obliquity. The flexion and extension gaps are balanced with the tibial resection. The principle of the "inverse kinematic alignment" is to resurface the tibia with similar medial and lateral bone resections in order to keep the native tibial joint line obliquity. Gap balancing is performed by adjusting the femoral resections. To avoid reproducing extreme anatomical alignments there is "restricted kinematic alignment" which is a compromise between mechanical alignment and true kinematic alignment with a defined safe zone of alignment. Finally, there is the concept of "functional alignment" which is an evolution of kinematic alignment as enabling technology has progressed. This is obtained by manipulating alignment, bone resections, soft tissue releases, and/or implant positioning with a robotic-assisted system to optimize TKA function for a patient's specific alignment, bone morphology, and soft tissue envelope. The aim of personalizing alignment is to restore native knee kinematics and improve functional outcomes after TKA. A long-term follow-up remains crucial to assess both outcomes and implant survivorship of these current concepts.

17.
J Arthroplasty ; 36(7): 2502-2509, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33744083

RESUMO

BACKGROUND: The use of morphometric implants in total knee arthroplasty (TKA) has shown better early clinical outcomes compared to conventional implants. The primary objective of this study is to evaluate the functional outcome and the implant survivorship of a morphometric TKA at a minimum of 5 years of follow-up. METHODS: From May 2012 to June 2015, all patients undergoing primary TKA with a single design of morphometric posterior-stabilized prosthesis (Persona; Zimmer) in a prospective observational single-center study were evaluated. The Knee Society Scoring System (KSS) and the Knee Injury and Osteoarthritis Outcome Score (KOOS) were completed preoperatively, 1, 3, and 5 years postoperatively. Kaplan-Meier was used to calculate survivorship of the implants. The average follow-up was 75 months. RESULTS: In total, 237 TKAs were performed in 235 patients with a mean age of 73 years (49-90). The KSS Knee Score increased from 44.7 (13-64) preoperatively to 93.6 (71-100), the KSS Function Score from 45.8 (17-69) to 92.2 (51-98), and the KSS Satisfaction Score from 26.6 (16-51) to 41 (35-55) at 5 years of follow-up. Similarly, for the KOOS score, a significant improvement of all the subscales was observed at 5 years of follow-up. Implant survival without reoperation at 5 years of follow up was 98.72% (95% confidence interval 0.95-1.00). CONCLUSION: This is the first study demonstrating that significant improvements of the functional scores with good survivorship can be achieved at a minimum of 5 years of follow-up with TKA using morphometric implants.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Osteoartrite , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Articulação do Joelho/cirurgia , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Desenho de Prótese , Resultado do Tratamento
18.
Arthrosc Tech ; 10(2): e431-e435, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33680776

RESUMO

Medial opening wedge high tibial osteotomy (OW-HTO) is an excellent surgical option for patients with varus knee osteoarthritis. This article presents a technique of performing a minimally invasive OW-HTO using a patient-specific cutting guide (PSCG). Preoperative 3-dimensional planning with computed tomography imaging is essential. The correction parameters, the final plate position, as well as the 3-dimensional position of the hinge as well as wedge are verified preoperatively before the PSCG is produced. After exposure with an oblique incision over the posteromedial tibia, the hamstring tendons are released for later re-attachment and the medial collateral ligament is released slightly. The PSCG is then used to perform the OW-HTO with protection of the posterior neurovascular structures by a retractor placed posterior to the medial collateral ligament. The final fixation of the osteotomy is achieved with a low-profile locking plate and a femoral head allograft wedge.

19.
Arthrosc Tech ; 10(1): e61-e65, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33532209

RESUMO

Patellar lower-pole fractures occur in relatively young patients after eccentric contraction of the quadriceps or direct trauma. Early diagnosis and adequate treatment lead to excellent outcomes and prevent tendon retraction and scarring. The aim of surgical treatment is to restore articular congruence and reestablish the extensor mechanism of the knee. All surgical treatments (sutures and tension band wiring, separate vertical wiring or augmented with Krackow sutures, wiring through screws, basket plate, hook plate) use additional hardware. We propose a hardware-free technique using ipsilateral hamstring augmentation.

20.
Knee Surg Sports Traumatol Arthrosc ; 29(3): 849-858, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32372282

RESUMO

PURPOSE: Given the goal of achieving optimal correction and alignment after knee arthroplasty or high tibial osteotomy, literature focusing on the inter-individual variability of the native knee, tibia and femur with regards to the coronal or sagittal alignment is lacking. The aim of this study was to analyse normal angular values in the healthy middle-aged population and determine differences of angular values according to inter-individual features. The first hypothesis was that common morphological patterns may be identified in the healthy middle-aged non-osteoarthritic population. The second hypothesis was that high inter-individual variability exists with regards to gender, ethnicity and alignment phenotype. METHODS: A CT scan-based modelling and analysis system was used to examine the lower limb of 758 normal healthy patients (390 men, 368 women; mean age 58.5 ± 16.4 years) with available data concerning angular values and retrieved from the SOMA database. The hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), posterior distal femoral angle (PDFA), posterior proximal tibial angle (PPTA) and non weight-bearing joint line convergence angle (nwJLCA) were then measured for each patient. Results were analysed for the entire cohort and based on gender, ethnicity and phenotype. RESULTS: The mean HKA was 179.4° ± 2.6°, LDFA: 85.8° ± 2.0°, MPTA: 85.6° ± 2.4°, PDFA: 85.2° ± 1.5°, PPTA: 83.8° ± 2.9° and nwJLCA: 1.09° ± 0.9°. Gender was associated with higher LDFA and lower HKA for men. Ethnicity was associated with greater proximal tibial vara and distal femoral valgus for Asian patients. Patients with an overall global varus alignment had more tibia vara and less femoral valgus than patients with an overall valgus alignment. CONCLUSION: Even if significant differences were found based on subgroup analysis (gender, ethnicity or phenotype), this study demonstrated that neutral alignment is the main morphological pattern in the healthy middle-aged population. This neutrality is the result from tibia vara compensated by an ipsilateral femoral valgus. LEVEL OF CLINICAL EVIDENCE: III, retrospective cohort study.


Assuntos
Fêmur/anatomia & histologia , Articulação do Joelho/anatomia & histologia , Tíbia/anatomia & histologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Tornozelo/anatomia & histologia , Tornozelo/diagnóstico por imagem , Artroplastia do Joelho , Criança , Feminino , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Quadril/anatomia & histologia , Quadril/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/cirurgia , Osteotomia , Valores de Referência , Estudos Retrospectivos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Tomografia Computadorizada por Raios X , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA