Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Foods ; 12(20)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37893732

RESUMO

Laboratory testing methods to confirm the identity of meat products and eliminate food fraud regularly rely on PCR amplification of extracted DNA, with most published assays detecting mitochondrial sequences, providing sensitive presence/absence results. By targeting single-copy nuclear targets instead, relative quantification measurements are achievable, providing additional information on the proportions of meat species detected. In this Methods paper, new assays for horse, donkey, duck, kangaroo, camel, water buffalo and crocodile have been developed to expand the range of species that can be quantified, and a previously published reference assay targeting the myostatin gene has been modified to include marsupials and reptiles. The accuracy of this ratio measurement approach was demonstrated using dPCR with mixtures of meat DNA down to 0.1%. However, the limit of detection (LOD) of this approach is not just determined by the assay targets, but by the samples themselves, with food or feed ingredients and processing impacting the DNA yield and integrity. In routine testing settings, the myostatin assay can provide multiple quality control roles, including monitoring the yield and purity of extracted DNA, identifying the presence of additional meats not detected by the suite of species-specific assays and potentially estimating a sample-specific LOD based on measured copy numbers of the myostatin target. In addition to the myostatin positive control assay, a synthetic DNA reference material (RM) has been designed, containing PCR targets for beef, pork, sheep, chicken, goat, kangaroo, horse, water buffalo and myostatin, to be used as a positive template control. The availability of standardised measurement methods and associated RMs significantly improves the reliability, comparability and transparency of laboratory testing, leading to greater confidence in results.

2.
Anal Chem ; 91(19): 12268-12274, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31465204

RESUMO

High accuracy, reliability, and reproducibility of genetic analyses in various applications require optimized and validated protocols and standards. Optimal procedures for storing the genetic material extracted from biological samples are equally important. In this study, we investigated the stability of dilute (4000 cp/µL, nominal concentration, equivalent to 0.02 ng/mL) DNA solutions stored at 4, -20, and -80 °C in the presence or absence of nucleic acid carriers. As representative examples, we used different formulations of a linearized plasmid DNA solution considered for characterization as reference materials (RMs) for specific applications. Employing droplet digital PCR, a highly accurate and precise method for quantification of nucleic acid not requiring a calibrant, we demonstrated that inclusion of a carrier nucleic acid in the formulation (at 50 ng/µL) improved the plasmid stability at -20 and -80 °C. For the case of a DNA standard used in real-time PCR assays for human erythropoietin gene, cDNA or transcript, we found that inclusion of yeast RNA in the formulation was preferred over salmon testes DNA as it had no effect on PCR amplification and provided the lowest relative expanded uncertainty for the characterized RM. RNA background may also be preferred as it is applicable to a broader range of DNA RMs. Our findings are important in production of reliable, stable DNA standards, including DNA RMs. These results can be used when selecting protocols for stable storage of DNA either extracted from biological samples or synthesized in a laboratory.


Assuntos
DNA/química , Reação em Cadeia da Polimerase em Tempo Real/normas , Animais , DNA/normas , Eritropoetina/genética , Congelamento , Humanos , Plasmídeos , Controle de Qualidade , Padrões de Referência , Reprodutibilidade dos Testes , Salmão/genética , Temperatura
3.
Biomol Detect Quantif ; 8: 15-28, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27335807

RESUMO

Measurement of RNA can be used to study and monitor a range of infectious and non-communicable diseases, with profiling of multiple gene expression mRNA transcripts being increasingly applied to cancer stratification and prognosis. An international comparison study (Consultative Committee for Amount of Substance (CCQM)-P103.1) was performed in order to evaluate the comparability of measurements of RNA copy number ratio for multiple gene targets between two samples. Six exogenous synthetic targets comprising of External RNA Control Consortium (ERCC) standards were measured alongside transcripts for three endogenous gene targets present in the background of human cell line RNA. The study was carried out under the auspices of the Nucleic Acids (formerly Bioanalysis) Working Group of the CCQM. It was coordinated by LGC (United Kingdom) with the support of National Institute of Standards and Technology (USA) and results were submitted from thirteen National Metrology Institutes and Designated Institutes. The majority of laboratories performed RNA measurements using RT-qPCR, with datasets also being submitted by two laboratories based on reverse transcription digital polymerase chain reaction and one laboratory using a next-generation sequencing method. In RT-qPCR analysis, the RNA copy number ratios between the two samples were quantified using either a standard curve or a relative quantification approach. In general, good agreement was observed between the reported results of ERCC RNA copy number ratio measurements. Measurements of the RNA copy number ratios for endogenous genes between the two samples were also consistent between the majority of laboratories. Some differences in the reported values and confidence intervals ('measurement uncertainties') were noted which may be attributable to choice of measurement method or quantification approach. This highlights the need for standardised practices for the calculation of fold change ratios and uncertainties in the area of gene expression profiling.

4.
Biomol Detect Quantif ; 3: 17-24, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27077030

RESUMO

This study presents the results from an interlaboratory sequencing study for which we developed a novel high-resolution method for comparing data from different sequencing platforms for a multi-copy, paralogous gene. The combination of PCR amplification and 16S ribosomal RNA gene (16S rRNA) sequencing has revolutionized bacteriology by enabling rapid identification, frequently without the need for culture. To assess variability between laboratories in sequencing 16S rRNA, six laboratories sequenced the gene encoding the 16S rRNA from Escherichia coli O157:H7 strain EDL933 and Listeria monocytogenes serovar 4b strain NCTC11994. Participants performed sequencing methods and protocols available in their laboratories: Sanger sequencing, Roche 454 pyrosequencing(®), or Ion Torrent PGM(®). The sequencing data were evaluated on three levels: (1) identity of biologically conserved position, (2) ratio of 16S rRNA gene copies featuring identified variants, and (3) the collection of variant combinations in a set of 16S rRNA gene copies. The same set of biologically conserved positions was identified for each sequencing method. Analytical methods using Bayesian and maximum likelihood statistics were developed to estimate variant copy ratios, which describe the ratio of nucleotides at each identified biologically variable position, as well as the likely set of variant combinations present in 16S rRNA gene copies. Our results indicate that estimated variant copy ratios at biologically variable positions were only reproducible for high throughput sequencing methods. Furthermore, the likely variant combination set was only reproducible with increased sequencing depth and longer read lengths. We also demonstrate novel methods for evaluating variable positions when comparing multi-copy gene sequence data from multiple laboratories generated using multiple sequencing technologies.

5.
Anal Bioanal Chem ; 406(26): 6529-37, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24948089

RESUMO

Hypermethylation at promoter regions of tumour suppressor genes is diagnostic for many cancers. Many genomic regions that may be the targets for clinical diagnostic assays have been identified through use of measuring systems reliant on bisulphite conversion, but few of these promising markers are in clinical use. The comparability of a widely used DNA methylation measuring system involving bisulphite conversion was evaluated by supplying three experienced centres with methylated DNA reference material mixtures that were independently prepared and characterised by mass spectrometry and high-pressure liquid chromatography. A replication scheme was designed to evaluate reproducibility of key analytical steps within and between laboratories by regression analysis. In general, methylation was underestimated and methylation ratio values were highly variable. The difference in methylation ratio between CpG sites was the key contributor to variable results. The CpG site effect followed a similar pattern at all centres and at all methylation levels examined indicating that sequence context had a major effect on methylation ratio measurement using the bisulphite conversion process. The magnitude of underestimation combined with the variability of measurements between CpG sites compromises the concept of measuring genomic regional methylation by averaging the methylation ratios of many CpG sites. There were no significant differences in replicate bisulphite conversions or sample work-up and instrument analysis at each centre thus making this technique suitable for comparative intralaboratory investigations. However, it may not be suitable for a routine diagnostic assay without extensive standardisation efforts.


Assuntos
Metilação de DNA , DNA/genética , Genes p16 , Neoplasias/genética , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sequência de Bases , Cromatografia Líquida de Alta Pressão/métodos , Ilhas de CpG , DNA/análise , Humanos , Dados de Sequência Molecular , Regiões Promotoras Genéticas , Reprodutibilidade dos Testes , Análise de Sequência de DNA/métodos , Sulfitos/química
6.
Anal Bioanal Chem ; 396(6): 2091-102, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19943159

RESUMO

Current screening and event-specific polymerase chain reaction (PCR) assays for the detection and identification of genetically modified organisms (GMOs) in samples of unknown composition or for the detection of non-regulated GMOs have limitations, and alternative approaches are required. A transgenic DNA fingerprinting methodology using restriction enzyme digestion, adaptor ligation, and nested PCR was developed where individual GMOs are distinguished by the characteristic fingerprint pattern of the fragments generated. The inter-laboratory reproducibility of the amplified fragment sizes using different capillary electrophoresis platforms was compared, and reproducible patterns were obtained with an average difference in fragment size of 2.4 bp. DNA insert fingerprints for 12 different maize events, including two maize hybrids and one soy event, were generated that reflected the composition of the transgenic DNA constructs. Once produced, the fingerprint profiles were added to a database which can be readily exchanged and shared between laboratories. This approach should facilitate the process of GMO identification and characterization.


Assuntos
Impressões Digitais de DNA/métodos , Glycine max/genética , Plantas Geneticamente Modificadas/genética , Zea mays/genética , Sequência de Bases , DNA de Plantas/química , DNA de Plantas/genética , Engenharia Genética , Dados de Sequência Molecular , Plantas Geneticamente Modificadas/química , Reação em Cadeia da Polimerase , Alinhamento de Sequência , Glycine max/química , Zea mays/química
7.
Anal Bioanal Chem ; 396(6): 2143-50, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19816678

RESUMO

Quantitative analysis of genetically modified (GM) foods requires estimation of the amount of the transgenic event relative to an endogenous gene. Regulatory authorities in the European Union (EU) have defined the labelling threshold for GM food on the copy number ratio between the transgenic event and an endogenous gene. Real-time polymerase chain reaction (PCR) is currently being used for quantification of GM organisms (GMOs). Limitations in real-time PCR applications to detect very low number of DNA targets has led to new developments such as the digital PCR (dPCR) which allows accurate measurement of DNA copies without the need for a reference calibrator. In this paper, the amount of maize MON810 and hmg copies present in a DNA extract from seed powders certified for their mass content and for their copy number ratio was measured by dPCR. The ratio of these absolute copy numbers determined by dPCR was found to be identical to the ratios measured by real-time quantitative PCR (qPCR) using a plasmid DNA calibrator. These results indicate that both methods could be applied to determine the copy number ratio in MON810. The reported values were in agreement with estimations from a model elaborated to convert mass fractions into copy number fractions in MON810 varieties. This model was challenged on two MON810 varieties used for the production of MON810 certified reference materials (CRMs) which differ in the parental origin of the introduced GM trait. We conclude that dPCR has a high metrological quality and can be used for certifying GM CRMs in terms of DNA copy number ratio.


Assuntos
Plantas Geneticamente Modificadas/genética , Reação em Cadeia da Polimerase/métodos , Zea mays/genética , DNA de Plantas/genética
8.
Electrophoresis ; 28(18): 3193-200, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17696213

RESUMO

A simple amplified fragment length polymorphism (AFLP) model, using the bacteriophage lambda genome, was developed to test the reproducibility of this technique in an international comparative study. Using either non-selective or selective primers, nine fragments or subsets of two or three fragments, respectively, were predicted using in silico software. Under optimized conditions, all predicted fragments were experimentally generated. The reproducibility of the AFLP model was tested by submitting both "unknown" DNA template that had been restricted and ligated with AFLP linkers (R/L mixture) and corresponding primer pairs to nine laboratories participating in the study. Participants completed the final PCR step and then used either slab gel electrophoresis or CE to detect the AFLP fragments. The predicted fragments were identified by the majority of participants with size estimates consistently up to 3 base pair (bp) larger for slab gel electrophoresis than for CE. Shadow fragments, 3 bp larger than the predicted fragments, were often observed by study participants and organizers. The nine AFLP fragments exhibited relative intensities ranging from less than 3% to 22% and, apart from the two weakest fragments, with a % CV of 16 to 25. Fragments containing the highest guanine-cytosine (GC) content of 50-56% showed the greatest stability in the AFLP profiles.


Assuntos
Modelos Teóricos , Polimorfismo Genético , DNA/química , Eletroforese Capilar/métodos , Reação em Cadeia da Polimerase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA