Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Molecules ; 29(3)2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38338316

RESUMO

BACKGROUND: The development of an anti-drug antibody (ADA)-tolerant pharmacokinetic (PK) assay is important when the drug exposure is irrelevant to toxicity in the presence of ADA. We aimed to develop and validate an ADA-tolerant assay for an exatecan-based antibody-drug conjugate (ADC) in monkey plasma. RESULTS: The assay tolerated 5.00 µg/mL of ADA at 12 µg/mL of ADC. Its accuracy and precision results satisfied the acceptance criteria. Furthermore, the assay was free from hook and matrix effects and exhibited good dilutional linearity. Additionally, the ADC in plasma samples was stable under different storage conditions. METHOD: An ADA-tolerant ADC assay was configured with an anti-payload antibody for capture, and a drug-target protein combined with a horseradish peroxidase (HRP)-labeled antibody against a drug-target-protein tag for detection. Samples were firstly acidified to dissociate drug and ADA complexes, and to convert the carboxylate form to the lactone form of exatecan molecules; then, the ADAs in the samples were removed with a naked antibody-coated microplate. The treated samples were further incubated with coated anti-payload antibody and captured ADC molecules were quantified by the detection reagent. The developed assay was optimized and validated against regulatory guidelines. CONCLUSIONS: The assay met both methodological and sample-related ADA tolerance requirements, and was applicable to a nonclinical study in cynomolgus monkeys.


Assuntos
Camptotecina/análogos & derivados , Imunoconjugados , Animais , Haplorrinos , Anticorpos
2.
AAPS J ; 25(4): 69, 2023 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-37421491

RESUMO

Evolving immunogenicity assay performance expectations and a lack of harmonized neutralizing antibody validation testing and reporting tools have resulted in significant time spent by health authorities and sponsors on resolving filing queries. A team of experts within the American Association of Pharmaceutical Scientists' Therapeutic Product Immunogenicity Community across industry and the Food and Drug Administration addressed challenges unique to cell-based and non-cell-based neutralizing antibody assays. Harmonization of validation expectations and data reporting will facilitate filings to health authorities and are described in this manuscript. This team provides validation testing and reporting strategies and tools for the following assessments: (1) format selection; (2) cut point; (3) assay acceptance criteria; (4) control precision; (5) sensitivity including positive control selection and performance tracking; (6) negative control selection; (7) selectivity/specificity including matrix interference, hemolysis, lipemia, bilirubin, concomitant medications, and structurally similar analytes; (8) drug tolerance; (9) target tolerance; (10) sample stability; and (11) assay robustness.


Assuntos
Anticorpos Neutralizantes , Preparações Farmacêuticas , Tolerância a Medicamentos
4.
Bioanalysis ; 10(7): 445-449, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29708430

RESUMO

The 18th Annual Land O'Lakes Bioanalytical Conference, titled 'Cutting-Edge Bioanalytical Technologies and Concepts - Issues, Solutions and Practical Considerations for Applications in Novel and Emerging Modalities', was held 10-13 July 2017 in Madison, WI, USA. This Land O'Lakes Conference is presented each year by the Division of Pharmacy Professional Development within the School of Pharmacy at the University of Wisconsin-Madison (USA). The purpose of this conference is to provide an educational forum to discuss issues and applications associated with the analysis of xenobiotics, metabolites, biologics and biomarkers in biological matrices. The conference is designed to include and encourage an open exchange of scientific and methodological applications for bioanalysis. This report summarized the presentations at the 18th Annual Conference.


Assuntos
Biomarcadores/análise , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas em Tandem/métodos , Xenobióticos/análise , Humanos
5.
Bioanalysis ; 6(18): 2385-90, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25384591

RESUMO

The topic of incurred sample stability (ISS) has generated considerable discussion within the bioanalytical community in recent years. The subject was an integral part of the seventh annual Workshop on Recent Issues in Bioanalysis (WRIB) held in Long Beach, CA, USA, in April 2013, and at the Global CRO Council for Bioanalysis (GCC) meeting preceding it. Discussion at both events focused on the use of incurred samples for ISS purposes in light of results from a recent GCC survey completed by member companies. This paper reports the consensus resulting from these discussions and serves as a useful reference for depicting ISS issues and concerns, summarizing the GCC survey results and providing helpful recommendations on ISS in the context of bioanalytical method development and application.


Assuntos
Testes de Química Clínica , Coleta de Dados , Reprodutibilidade dos Testes
7.
Bioanalysis ; 6(10): 1349-56, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24958119

RESUMO

With the globalization of drug development, there is an increasing need for global bioanalytical support. Bioanalysis provides pivotal data for toxicokinetic, pharmacokinetic, bioavailability and bioequivalence studies used for regional or global regulatory submission. There are many known complications in building a truly global bioanalytical operation, ranging from lack of global regulatory guidelines and global standard operating procedures to barriers in regional requirements on sample shipping, importation and exportation. The primary objective of this article is to discuss common experiences and challenges facing the biopharmaceutical industry when providing bioanalytical support in a global setting. The key components of global bioanalytical services include the supporting infrastructure, spanning project management, IT support of data management, best practices in bioanalytical method transfer and sample analysis, and comprehensive knowledge of the requirements of bioanalysis guidelines and differences in these guidelines. A case study will highlight best practices for successful management of a global project.


Assuntos
Preparações Farmacêuticas/metabolismo , Avaliação de Medicamentos/normas , Gestão da Informação/normas , Laboratórios/organização & administração , Serviços Terceirizados/organização & administração , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/normas , Controle de Qualidade
8.
Artigo em Inglês | MEDLINE | ID: mdl-23435343

RESUMO

Automated sample extraction for regulated bioanalysis by liquid chromatography/tandem mass spectrometry (LC-MS/MS) still presents significant challenges. A new sample preparation methodology with a simplified and completely automated workflow was developed to overcome these challenges using cap piercing for direct biofluid transfer and evaporation-free solid phase extraction (SPE). Using pierceable cap sample tubes, a robotic liquid handler was able to sample without uncapping or recapping during sample preparation. Evaporation for SPE was eliminated by using a mobile phase-compatible elution solvent followed by sample dilution prior to LC-MS/MS analysis. Presented here are three LC-MS/MS assays validated using this methodology to support three CNS drug development programs: (1) BMS-763534 and its metabolite, BMS-790318, in dog plasma; (2) BMS-694153 in monkey plasma; and (3) Pexacerfont (BMS-562086) and two metabolites, BMS-749241 and DPH-123554, in human plasma. These assays were linear from 1.00 to 1000 or 2.00 to 2000ng/mL for each analyte with excellent assay accuracy, precision and reproducibility. These assays met acceptance criteria for regulated bioanalysis and have been successfully applied to drug development study samples. The methodology described here successfully eliminated all manual intervention steps achieving fully automated sample preparation without compromising assay performance. Importantly, this methodology eliminates the potential exposure of the bioanalyst to any infectious biofluids during sample preparation.


Assuntos
Antagonistas do Receptor do Peptídeo Relacionado ao Gene de Calcitonina , Indazóis/sangue , Pirazóis/sangue , Quinazolinonas/sangue , Receptores de Hormônio Liberador da Corticotropina/antagonistas & inibidores , Extração em Fase Sólida/métodos , Manejo de Espécimes/métodos , Espectrometria de Massas em Tandem/métodos , Triazinas/sangue , Animais , Cromatografia Líquida/economia , Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Cães , Desenho de Equipamento , Haplorrinos , Ensaios de Triagem em Larga Escala/economia , Ensaios de Triagem em Larga Escala/instrumentação , Ensaios de Triagem em Larga Escala/métodos , Humanos , Indazóis/metabolismo , Pirazóis/metabolismo , Quinazolinonas/metabolismo , Sensibilidade e Especificidade , Extração em Fase Sólida/economia , Extração em Fase Sólida/instrumentação , Manejo de Espécimes/economia , Manejo de Espécimes/instrumentação , Espectrometria de Massas em Tandem/economia , Espectrometria de Massas em Tandem/instrumentação , Triazinas/metabolismo
9.
J Chromatogr B Analyt Technol Biomed Life Sci ; 852(1-2): 77-84, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17280881

RESUMO

BMS-068645 is a selective adenosine 2A agonist that contains a methyl ester group which undergoes esterase hydrolysis to its acid metabolite. To permit accurate determinations of circulating BMS-068645 and its acid metabolite, blood samples must be rapidly stabilized at the time of collection. A sensitive, rapid and specific liquid chromatography-tandem mass spectrometry (LC/MS/MS) method for the simultaneous quantitation of BMS-068645 and its acid metabolite in human plasma has been developed and validated using diisopropyl fluorophosphate (DFP) as the esterase inhibitor to prevent BMS-068645 from converting to its acid metabolite. The D(5)-stable isotope labeled analogs of BMS-068645 and its metabolite were used as the internal standards (IS). Analytes and IS in plasma containing 20 mM DFP were acidified and extracted into methyl tert-butyl ether. The liquid-liquid extraction effectively eliminated the strong matrix effect caused by the esterase inhibitor. The chromatographic separation was achieved on a Waters Atlantis C18 column with a run time of 4 min. Detection was performed on a Sciex API 4000 with positive ion electrospray mode (ESI/MS/MS), monitoring the ion transitions m/z 487>314 and 473>300 for BMS-068645 and its acid metabolite, respectively. The method was validated over the range from 0.020 to 10.0 ng/mL for BMS-068645 and 0.050 to 10.0 ng/mL for its acid metabolite. Inter- and intra-run precision for the quality control samples during validation were less than 8.7% and 4.0%, respectively, for the two analytes. The assay accuracy was within +/-5.4% of the nominal values. The esterase inhibitor effectively stabilized BMS-068645 during blood collection and storage. Blood collection tubes containing DFP were easily prepared and used at the clinical sites and could be stored at -30 degrees C for 3 months. This method demonstrated adequate sensitivity, specificity, accuracy, precision, stability and ruggedness to support the analysis of human plasma samples in pharmacokinetic studies.


Assuntos
Alcinos/sangue , Cromatografia Líquida/métodos , Inibidores Enzimáticos/química , Esterases/antagonistas & inibidores , Isoflurofato/química , Nucleosídeos de Purina/sangue , Agonistas do Receptor Purinérgico P1 , Espectrometria de Massas em Tandem/métodos , Alcinos/farmacocinética , Calibragem , Ésteres , Humanos , Nucleosídeos de Purina/farmacocinética , Padrões de Referência , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/métodos
10.
Electrophoresis ; 25(21-22): 3528-49, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15565707

RESUMO

Significant progress in the development of miniaturized microfluidic systems has occurred since their inception over a decade ago. This is primarily due to the numerous advantages of microchip analysis, including the ability to analyze minute samples, speed of analysis, reduced cost and waste, and portability. This review focuses on recent developments in integrating electrochemical (EC) detection with microchip capillary electrophoresis (CE). These detection modes include amperometry, conductimetry, and potentiometry. EC detection is ideal for use with microchip CE systems because it can be easily miniaturized with no diminution in analytical performance. Advances in microchip format, electrode material and design, decoupling of the detector from the separation field, and integration of sample preparation, separation, and detection on-chip are discussed. Microchip CEEC applications for enzyme/immunoassays, clinical and environmental assays, as well as the detection of neurotransmitters are also described.


Assuntos
Eletroforese em Microchip/instrumentação , Animais , Testes de Química Clínica , Eletroquímica , Eletroforese em Microchip/métodos , Poluentes Ambientais/análise , Desenho de Equipamento , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA