Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Ophthalmic Surg Lasers Imaging Retina ; 54(11): 666-669, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37855828

RESUMO

We describe seven patients who were attempting to repair their garage door when a spring dislodged at high velocity, resulting in open globe injury. All patients were seen at Massachusetts Eye and Ear between the years 2008 and 2023. Their final visual acuities ranged from 20/125 to no light perception. Open globe injury appears to be a risk of attempts to repair a garage door by people who are inexperienced in doing so. [Ophthalmic Surg Lasers Imaging Retina 2023;54:666-669.].


Assuntos
Ferimentos Oculares Penetrantes , Traumatismos Oculares , Humanos , Estudos Retrospectivos , Traumatismos Oculares/cirurgia , Acuidade Visual , Ferimentos Oculares Penetrantes/diagnóstico , Ferimentos Oculares Penetrantes/cirurgia , Prognóstico
2.
Graefes Arch Clin Exp Ophthalmol ; 261(4): 935-940, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36350430

RESUMO

PURPOSE: We compare the ability of resident physicians to identify retinal breaks on ultra-widefield color fundus photos using the traditional image compared to an image with a green filter overlay. METHODS: Residents were shown fundus photos of 10 eyes with either a retinal tear or hole. Participants were shown each photo twice-once with traditional color settings and once with a green filter overlay. Participants were scored on whether the break was correctly identified and timed on how long it took to identify the pathology. RESULTS: Residents were able to correctly identify more retinal breaks on fundus photos with a green filter overlay compared to photos with traditional settings (P = 0.02). Residents were also able to identify breaks on fundus photos more quickly on images with a green filter overlay compared to the traditional images (P < 0.001). CONCLUSIONS: The application of a green filter overlay may help in identifying retinal breaks.


Assuntos
Perfurações Retinianas , Humanos , Perfurações Retinianas/diagnóstico , Angiofluoresceinografia/métodos , Fundo de Olho , Tomografia de Coerência Óptica/métodos
3.
Case Rep Ophthalmol Med ; 2022: 5830617, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36504920

RESUMO

Purpose. To report the successful treatment of a case of presumed infectious crystalline keratopathy with repeated intrastromal antibiotic injections in a cornea graft in the setting of severe ocular graft-vs.-host-disease (GVHD). Observations. A 62-year-old man with a history of ocular GVHD and tectonic penetrating keratoplasty (PK) for corneal melt from herpes zoster keratopathy developed presumed infectious crystalline keratopathy (ICK) in the corneal graft. Given the patient's complicated ocular history, chronic immunosuppression and new cardiac comorbidities, a therapeutic PK would most likely fail. Efforts were then directed to rescue the graft with minimally invasive approaches. Two separate intrastromal injections of cefuroxime and moxifloxacin successfully treated his ICK. Conclusions and Importance. This case supports a role for repeated intrastromal antibiotic injections in patients with ICK refractory to topical antibiotic therapy, which might eliminate the need for therapeutic PK and preserve vision.

5.
Clin Ophthalmol ; 15: 3727-3731, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34511877

RESUMO

PURPOSE: Since the start of the COVID-19 pandemic, numerous authors have published data demonstrating retinal changes found in patients with COVID-19. However, others have debated the significance of these findings and the effects of COVID-19 on the retina remain uncertain. This study aims to better understand retinal findings in patients with COVID-19. PATIENTS AND METHODS: A retrospective review of patients with a history of a positive COVID-19 polymerase chain reaction test was performed between March 1st, 2020 and October 31st, 2020. Patients were included if they presented within 90 days of their first positive COVID-19 test and underwent color fundus photography and/or OCT of the macula. All images were reviewed by two independent graders who assessed the presence of retinal heme, cotton wool spots, vascular sheathing, and disc edema, as well as hyper-reflective changes, intra-retinal fluid, and sub-retinal fluid on OCT. RESULTS: A total of 119 eyes from 61 patients were included. Among 83 eyes which underwent OCT of the macula, inner retinal hyper-reflective changes were seen in 16.9% (n=14), outer retinal hyper-reflective changes in 18.1% (n=15), intra-retinal fluid in 28.9% (n=24), and sub-retinal fluid in 14.5% (n=12). Among 48 eyes which underwent color fundus photography, retinal hemorrhage was seen in 27.1% (n=13), optic disc edema in 2.1% (n=1), and cotton wool spots in none of the eyes. Sub-analysis of 70 eyes from 41 patients with no alternative retinal pathology to potentially explain the above findings revealed none of the above exam findings on OCT of the macula (n=35), fundus photography (n=28), or documented exam (n=66). CONCLUSION: While a number of patients seen after COVID-19 infection demonstrated retinal findings, all could be explained by pre-existing retinal conditions. In a sub-group of eyes without pre-existing retinal disease, we did not identify any retinal findings that could be associated with COVID-19.

7.
Orbit ; 38(1): 84-86, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29565715

RESUMO

Adnexal and periocular involvement in Neisseria gonorrhoeae (NG) infection is rare. This report describes the case of a patient with a delayed diagnosis of gonococcal dacryoadenitis with contiguous conjunctivitis and corneal involvement. She underwent extensive inpatient laboratory and infectious workup but rapidly progressed to corneal perforation requiring emergent penetrating keratoplasty prior to a positive culture confirming the diagnosis. To date, this is the first reported case of ophthalmologic NG infection with associated conjunctivitis, dacryoadenitis, and corneal perforation.


Assuntos
Conjuntivite Bacteriana/microbiologia , Perfuração da Córnea/microbiologia , Dacriocistite/microbiologia , Infecções Oculares Bacterianas/microbiologia , Gonorreia/microbiologia , Neisseria gonorrhoeae/isolamento & purificação , Antibacterianos/uso terapêutico , Conjuntivite Bacteriana/diagnóstico , Conjuntivite Bacteriana/cirurgia , Perfuração da Córnea/diagnóstico , Perfuração da Córnea/cirurgia , Dacriocistite/diagnóstico , Dacriocistite/cirurgia , Infecções Oculares Bacterianas/diagnóstico , Infecções Oculares Bacterianas/cirurgia , Feminino , Gonorreia/diagnóstico , Gonorreia/cirurgia , Humanos , Ceratoplastia Penetrante , Tomografia Computadorizada por Raios X , Adulto Jovem
8.
J Biomech ; 60: 9-14, 2017 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-28583675

RESUMO

The mechanics of synovial fluid vary with disease progression, but are difficult to quantify quickly in a clinical setting due to small sample volumes. In this study, a novel technique to measure synovial fluid mechanics using magnetic nanoparticles is introduced. Briefly, microspheres embedded with superparamagnetic iron oxide nanoparticles, termed magnetic particles, are distributed through a 100µL synovial fluid sample. Then, a permanent magnet inside a protective sheath is inserted into the synovial fluid sample. Magnetic particles translate toward the permanent magnet and the percentage of magnetic particles collected by the magnet in a given time can be related to synovial fluid viscosity. To validate this relationship, magnetic particle translation was demonstrated in three phases. First, magnetic particle translation was assessed in glycerol solutions with known viscosities, demonstrating that as fluid viscosity increased, magnetic particle translation decreased. Next, the relationship between magnetic particle translation and synovial fluid viscosity was assessed using bovine synovial fluid that was progressively degenerated via ultrasonication. Here, particle collection in a given amount of time increased as fluid degenerated, demonstrating that the relationship between particle collection and fluid mechanics holds in non-Newtonian synovial fluid. Finally, magnetic particle translation was used to assess differences between healthy and OA affected joints in equine synovial fluid. Here, particle collection in a given time was higher in OA joints relative to healthy horses (p<0.001). Combined, these data demonstrate potential viability of magnetic particle translation in a clinical setting to evaluate synovial fluid mechanics in limited volumes of synovial fluid sample.


Assuntos
Doenças dos Cavalos/patologia , Nanopartículas de Magnetita/química , Osteoartrite/veterinária , Líquido Sinovial/fisiologia , Animais , Bovinos , Glicerol/química , Cavalos , Hidrodinâmica , Microesferas , Modelos Biológicos , Osteoartrite/patologia , Tamanho da Partícula , Poliestirenos/química , Soluções , Viscosidade , Água/química
9.
Patient Prefer Adherence ; 10: 1739-48, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27660423

RESUMO

PURPOSE: Patients with glaucoma who do not keep their follow-up eye care appointments are at risk for developing more severe ocular disease. The primary aim of the current study was to evaluate whether the use of a patient navigator altered adherence to follow-up eye care appointments in community-versus office-based settings. PATIENTS AND METHODS: Patients diagnosed with a glaucoma-related condition following a comprehensive eye examination at 43 community sites in Philadelphia, PA, USA, were enrolled in this prospective, randomized, controlled trial. Patients were randomized into three groups for a 1-year period: Group 1 (G1) received follow-up eye care in a community-based setting with assistance from a patient navigator; Group 2 (G2) received follow-up eye care in an office-based setting with assistance from a patient navigator; and Group 3 (G3) received follow-up eye care in an office-based setting without a patient navigator (usual care). Adherence rates were compared among these three groups using a chi-squared test at a significance level of 0.05. RESULTS: A total of 155 patients with glaucoma-related diagnoses were enrolled. The mean age (±standard deviation) was 71.2 (±10.0) years. Patients were predominantly female (65.8%, n=102/155) and African-American (71.6%, n=111/155). The mean (±standard deviation) number of follow-up visits during the 1-year study period was 1.3 (±1.3) for G1, 1.6 (±1.3) for G2, and 1.3 (±1.1) for G3 (P=0.48). Appointment adherence, defined as attendance of ≥1 follow-up visit, was 69.8% (n=37/53) for G1, 82.5% (n=47/57) for G2, and 73.3% (n=33/45) for G3, (P=0.28). Sub-analysis of adherence rates for patients who attended ≥2 follow-up visits were 91.3% (n=21/23) for G1, 74.3% (n=26/35) for G2, and 66.7% (n=18/27) for G3, (P=0.11). CONCLUSION: Help from a patient navigator did not increase the likelihood of keeping ≥1 follow-up appointment in an office-based setting. Adherence rates for follow-up appointments reached close to 70% or above in a self-selected patient population.

10.
J Glaucoma ; 25(9): 738-43, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27552512

RESUMO

PURPOSE: Glaucoma patients with markedly elevated intraocular pressure (IOP) are at risk for developing severe hypotony-related complications. The goal of this study was to compare the surgical outcomes of the Ahmed Glaucoma Valve (AGV) and the Baerveldt Glaucoma Implant (BGI) in this patient population. METHODS: Patients with preoperative IOP≥30 mm Hg were included. Outcome measures were: (1) surgical failure (IOP>21 mm Hg or <30% reduction from baseline or IOP≤5 mm Hg on 2 consecutive follow-up visits after 3 mo, or additional glaucoma surgery, or loss of light perception) and (2) surgical complications. RESULTS: A total of 75 patients were included: 37 in the AGV group and 38 in the BGI group. The mean±SD follow-up was 2.3±1.6 years for the AGV group and 2.4±1.7 years for the BGI group (P=0.643). Mean preoperative IOP was 38.7±6.5 mm Hg for the AGV group and 40.8±7.6 mm Hg for the BGI group. At the last follow-up, 10 (27.0%) patients failed in the AGV group compared with 6 (15.8%) patients in the BGI group (P=0.379). The BGI group had higher rate of flat or shallow anterior chamber (n=4, 10%) compared with the AGV group (n=0, 0%) (P=0.043). CONCLUSIONS: Failure rates of AGV and BGI in patients with IOP≥30 mm Hg were comparable. There were more early hypotony-related complications in the BGI group; however, none were vision threatening. Both glaucoma drainage implants were effective in treating patients with uncontrolled glaucoma in an emergency setting.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma/cirurgia , Pressão Intraocular/fisiologia , Implantação de Prótese , Adulto , Idoso , Anti-Hipertensivos , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/cirurgia , Estudos Retrospectivos , Tonometria Ocular , Resultado do Tratamento , Acuidade Visual/fisiologia
11.
Eur J Dent ; 2(3): 220-3, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19212552

RESUMO

Due to the angulation of maxillary bone as the maxillary bone resorption occurs from a buccal to palatal direction, bucco-lingually tilted implant placement is more likely especially in the posterior maxilla. The aim of this paper was to present a case restored by using a maxillary hybrid denture using Cresco method. A 59-year-old woman with an edentulous maxilla and five missing mandibular teeth was referred for implant treatment. Six months after sinus lift operation, four mandibular implants and six maxillary implants were placed. Due to the bucco-lingual tilt of two implants, the Cresco method was chosen to fabricate the metal framework for the maxillary hybrid denture that was delivered four months after implant placement. The main advantages of the Cresco method are a perfectly passive framework fit and corrected screw access holes. All ten implants placed were considered successful at 1-year recall, and no screw access holes were seen in the buccal part of the maxillary acrylic teeth. It was concluded that such screw-retained maxillary hybrid denture using the Cresco method met the esthetic expectations of a highly demanding patient.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA