Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Front Genet ; 8: 30, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28360924

RESUMO

Background: Genetic factors impact alcohol use behaviors and these factors may become increasingly evident during emerging adulthood. Examination of the effects of individual variants as well as aggregate genetic variation can clarify mechanisms underlying risk. Methods: We conducted genome-wide association studies (GWAS) in an ethnically diverse sample of college students for three quantitative outcomes including typical monthly alcohol consumption, alcohol problems, and maximum number of drinks in 24 h. Heritability based on common genetic variants (h2SNP) was assessed. We also evaluated whether risk variants in aggregate were associated with alcohol use outcomes in an independent sample of young adults. Results: Two genome-wide significant markers were observed: rs11201929 in GRID1 for maximum drinks in 24 h, with supportive evidence across all ancestry groups; and rs73317305 in SAMD12 (alcohol problems), tested only in the African ancestry group. The h2SNP estimate was 0.19 (SE = 0.11) for consumption, and was non-significant for other outcomes. Genome-wide polygenic scores were significantly associated with alcohol outcomes in an independent sample. Conclusions: These results robustly identify genetic risk for alcohol use outcomes at the variant level and in aggregate. We confirm prior evidence that genetic variation in GRID1 impacts alcohol use, and identify novel loci of interest for multiple alcohol outcomes in emerging adults. These findings indicate that genetic variation influencing normative and problematic alcohol use is, to some extent, convergent across ancestry groups. Studying college populations represents a promising avenue by which to obtain large, diverse samples for gene identification.

2.
Ann Thorac Surg ; 76(6): 2071-4; discussion 2074, 2003 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-14667645

RESUMO

PURPOSE: This study assessed the feasibility of using the VALR surgical system (Spiration Inc, Redmond, WA), limited by federal law to investigational use, for capturing and reducing a selected portion of affected lobes in patients undergoing lobectomy. DESCRIPTION: The tested system consists of a hand-held vacuum-regulated introducer loaded with a flexible, silicone sleeve. Targeted tissue is drawn into the introducer and the silicone sleeve is deployed and sutured in place. The end of the proximal sleeve includes a compression band for applying uniform radial pressure, suture ports, and silicone lugs lining the inner lumen for reinforcing sleeve position. EVALUATION: The system was effective in capturing 25% to 30% tissue of each lobe tested. Mean intraoperative test time was 8.5 minutes. The compression sleeve did not slip or dislodge after suturing, and no tissue damage or leaks were observed. CONCLUSIONS: It was feasible using vacuum to draw and isolate a portion of pulmonary tissue within a silicone sleeve. The system was intuitive to apply, easy to use, and produced effective reduction and sealing of tissue.


Assuntos
Pneumonectomia/instrumentação , Idoso , Carcinoma Pulmonar de Células não Pequenas/cirurgia , Estudos de Viabilidade , Humanos , Neoplasias Pulmonares/cirurgia , Masculino , Pessoa de Meia-Idade , Pneumonectomia/métodos , Vácuo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA