RESUMO
BACKGROUND AND OBJECTIVES: Thiopurines are an effective treatment for the maintenance of remission in inflammatory bowel disease (IBD). They can present adverse effects (AEs), with myelotoxicity being the most relevant. This study aims to determine the incidence of AEs related to the starting of thiopurines in our centre. METHODOLOGY: Retrospective study. The AEs in patients that were started on thiopurines between January 2016 and June 2020 were registered, with a two-year follow-up. The mean and standard deviation were used to describe the quantitative variables, and percentages and confidence intervals were used for the qualitative variables. The statistical significance was set at a p-value < 0.05. RESULTS: 98 patients were included, with 64 AEs detected in 48 patients (49%). Most of the AEs appeared in the first 6 months. The most relevant were: 21 neutropenia (21.4%), 19 hypertransaminasemia (19.4%), 13 digestive intolerances (13.2%), 6 acute pancreatitis (6.12%), 3 phototoxicity (3%), and 2 unknown origin fevers (2%). In 29 patients (29.4%) the treatment had to be suspended due to AEs. In 11 cases (11.2%), azathioprine (AZA) was switched to 6-mercaptopurine (6 MP) as 5 showed tolerance and 6 patients needed suspension due to AEs. Eight patients required hospital admission, but none of them needed intensive care unit admission. There were no fatal adverse effects. CONCLUSIONS: Thiopurines are a safe drug with few AEs, especially after the first months of treatment. These results suggest that periodic analytic follow-up may not be necessary after the initial period of treatment.
RESUMO
The aim of this study was to assess the long-term clinical behavior of straight implants in comparison with intentionally tilted dental implants (ITDI) supporting fixed restorations in partial or total edentulous arches, analyzing implant survival and success rates, complications, and marginal bone loss (MBL) after >5 years of function. An electronic search was conducted in five electronic databases (MEDLINE/Pubmed, Embase, Web of Science, Scopus, and Cochrane Central Register of Controlled Trials) supplemented by a manual search. The electronic and manual search identified 1853 articles, of which 8 articles were selected for analysis. Out of a total of 3987 dental implants, 2036 were axial dental implants and 1951 tilted. Similar results were found in implant survival or overall implant success rates. Moreover, no statistically significant differences were found in MBL (p = 0.369; MD 0.116 mm (-0.137; 0.369) 95% CI) The prosthodontic/biological complications reported in the articles were very diverse and irregularly distributed. This systematic review suggests that there is no difference between tilted compared with straight dental implants in the medium-long term (>5 years). However, further research is needed to generate long-term data and confirm the present review's findings.
RESUMO
Sleeve gastrectomy is currently the most frequently performed bariatric surgery. Postoperative leaks represent the main cause of morbidity in up to 8% of patients with a mortality rate ranging between 0.1 and 5%. However, management of these leaks remains controversial. We report the case of a patient presenting with sepsis 2 weeks after surgery. A subphrenic collection and a leak were found on CT. Despite medical treatment, the patient did not show clinical improvement. Hence, we considered a transgastric endosonographic-guided drainage of the collection using an electrocautery-enhanced lumen-apposing metal stent (LAMS). The procedure underwent uneventfully, and the patient status improved rapidly. Two weeks later, the stent was withdrawn. A follow-up endoscopy 6 weeks later showed closure of the gastric wall defect.