Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Hematol ; 12(5): 208-214, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37936975

RESUMO

Background: Erythrocyte sedimentation rate (ESR) indirectly measures blood fibrinogen, and it is altered by all those pathological conditions that modify the aggregation of red blood cells. The international guidelines by the International Council for Standardization in Hematology (ICSH) define the Westergren method as the gold standard for ESR, although it is completely operator-dependent, time-consuming, and requires a patient's blood consumption. Therefore, the validation of new ESR analyzers is needed. The aim of this study is the validation of a new automated ESR analyzer, MINI-CUBE (DIESSE, Diagnostica Senese, Italy). Methods: The samples (n = 270) were collected at the University Hospital of the University of Rome Tor Vergata. A comparison between the automated instrument and the gold standard was performed. Statistical analyses were processed by MedCalc software. Results: The comparison analysis performed on the overall samples reported a good agreement, showing a Spearman rank correlation coefficient of 0.94 (P < 0.001), compared to the Westergren test. The Bland-Altman analysis showed a mean bias of 1.5 (maximum (max.):19.6; minimum (min.): -16.6). Inter-run (level 1 coefficient of variation (CV): 4.9%; level 2 CV: 0.8%), intra-run (level 1 CV: 21.1%; level 2 CV: 3.2%), and inter-instrument (level 1 CV: 27.1%; level 2 CV: 5.6%) precision were also assessed. The hematocrit value did not interfere with the analysis: Spearman rank correlation coefficient of 0.929 (P < 0.001); mean bias of 1.3 (max.:18.3; min.: -15.6). Conclusions: Overall results from MINI-CUBE asserted a good correlation rate with the gold standard, and it could be considered an accurate, and objective alternative for the Westergren test.

2.
Diseases ; 11(4)2023 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-37987280

RESUMO

(1) Background: The erythrocyte sedimentation rate (ESR) is widely diffused in hematology laboratories to monitor inflammatory statuses, response to therapies (such as antibiotics), and oncologic diseases. However, ESR is not a specific diagnostic marker but needs to be contextualized and compared with clinical and other laboratory findings. This study aimed to investigate the performance of two automated instruments, namely the DIESSE CUBE 30 TOUCH (DIESSE, Siena, Italy) and the Alifax Test 1 (Alifax Srl, Polverara, Italy), in comparison with the gold standard, the Westergren method, in lymphoproliferative and myeloproliferative patients. (2) Methods: 97 EDTA samples were selected from the hematology department of Roma Tor Vergata Hospital and analyzed. Statistical analysis was applied. (3) A good correlation between CUBE 30 TOUCH and the gold standard was observed in the overall sample (R2 = 0.90), as well as in patients with lymphoproliferative diseases (R2 = 0.90) and myeloproliferative diseases (R2 = 0.90). The correlation between Test 1 and the gold standard was observed in the overall sample (R2 = 0.68), as well as in patients with lymphoproliferative diseases (R2 = 0.79) and myeloproliferative diseases (R2 = 0.53). (4) Conclusions: The CUBE 30 TOUCH appears to be a more trustworthy tool for evaluating ESR in these pathologies.

3.
Biomedicines ; 11(10)2023 Sep 28.
Artigo em Inglês | MEDLINE | ID: mdl-37893035

RESUMO

The use of vaccines has allowed the containment of coronavirus disease 2019 (COVID-19) at a global level. The present work aims to add data on vaccination by evaluating the level of neutralizing antibodies in individuals who have received a three-vaccination series. For this purpose, we ran a surveillance program directed at measuring the level of IgG Abs against the Receptor Binding Domain (RBD) and surrogate virus neutralizing Ab (sVNT) anti-SARS-CoV-2 in the serum of individuals undergoing vaccination. This study was performed on employees from the University of Rome Tor Vergata and healthcare workers from the University Hospital who received the Vaxzevria vaccine (n = 56) and Comirnaty vaccine (n = 113), respectively. After the second dose, an increase in both RBD and sVNT Ab values was registered. In individuals who received the Comirnaty vaccine, the antibody titer was about one order of magnitude higher after 6 months from the first dose. All participants in this study received the Comirnaty vaccine as the third dose, which boosted the antibody response. Five months after the third dose, nearly one year from the first injection, the antibody level was >1000 BAU/mL (binding antibody units/mL). According to the values reported in the literature conferring protection against SARS-CoV-2 infection, our data indicate that individuals undergoing three vaccine doses present a low risk of infection.

4.
Diseases ; 11(2)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37366871

RESUMO

Infectious diseases such as HIV and HBV are a global concern for their impact in terms of public health and costs for national health services. A central role in contrasting the spread of the infections is represented by timely diagnosis. The speed of detection depends on several factors including the type of test used. Antibody response to hepatitis B surface antigens (anti-HBs) is an important serological marker used for HBV-infection detection. The aim of this study was to compare the performance of the Abbott system and of the new analyser Mindray 1200i in the detection of HBV- and HIV-infections. Clinical serum samples were collected from patients randomly selected from PTV University Hospital of University of Rome "Tor Vergata" and tested for HBV and HIV antibodies. Samples were evaluated by Mindray Cl 1200i CLIA screening tests for HBV and HIV and the results were compared with the Abbott Architect analytical system, the routine instrument of the hospital clinical biochemistry laboratory. Precision study, linearity, and carryover were performed on the results obtained. The agreement between the results of the Abbott and Mindray CLIA ranged from 99% to 100% and the discrepancy rate from 0% to 1%. The measurements demonstrated that the Mindray CL-1200i platform offers high-level performance with accurate and consistent test results and could represent a valuable tool if implemented in routine analysis.

5.
Arch Virol ; 167(5): 1285-1291, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35377034

RESUMO

With the widespread use of coronavirus disease 2019 (COVID-19) vaccines, a rapid and reliable method to detect SARS-CoV-2 neutralizing antibodies (NAbs) is extremely important for monitoring vaccine effectiveness and immunity in the population. The purpose of this study was to evaluate the performance of the RapiRead™ reader and the TestNOW™ COVID-19 NAb rapid point-of-care (POC) test for quantitative measurement of antibodies against the spike protein receptor-binding domain of severe respiratory syndrome coronavirus 2 (SARS-CoV-2) in different biological matrices compared to chemiluminescence immunoassay (CLIA) methods. Ninety-four samples were collected and analyzed using a RapiRead™ reader and TestNOW™ COVID-19 NAb kits for detecting neutralizing antibodies, and then using two CLIAs. The data were compared statistically using the Kruskal-Wallis test for more than two groups or the Mann-Whitney test for two groups. Specificity and sensitivity were evaluated using a receiver operating characteristic (ROC) curve. Good correlation was observed between the rapid lateral flow immunoassay (LFIA) test system and both CLIA methods. RapiRead™ reader/TestNOW™ COVID-19 NAb vs. Maglumi: correlation coefficient (r) = 0.728 for all patients; r = 0.841 for vaccinated patients. RapiRead™ reader/TestNOW™ COVID-19 NAb vs. Mindray: r = 0.6394 in all patients; r = 0.8724 in vaccinated patients. The time stability of the POC serological test was also assessed considering two times of reading, 12 and 14 minutes. The data revealed no significant differences. The use of a RapiRead™ reader and TestNOW™ COVID-19 NAb assay is a quantitative, rapid, and valid method for detecting SARS-CoV-2 neutralizing antibodies and could be a useful tool for screening studies of SARS-CoV-2 infection and assessing the efficacy of vaccines in a non-laboratory context.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais/sangue , COVID-19/diagnóstico , Vacinas contra COVID-19 , Humanos , Imunoensaio/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Sensibilidade e Especificidade
6.
Clin Immunol ; 234: 108918, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34971839

RESUMO

The Spike-Receptor Binding Domain (S-RBD) is considered the most antigenic protein in SARS-CoV-2 and probably the key player in SARS-CoV-2 immune response. Quantitative immunoassays may help establish an anti-RBD Abs threshold as an indication of protective immunity. Since different immunoassays are commercial, the standard reference method for the neutralizing activity is the live Virus Neutralization Test (VNT). In this study, anti-RBD IgG levels were detected with two chemiluminescent immunoassays in paucisymptomatic, symptomatic and vaccinated subjects, and their neutralizing activity was correlated to VNT titer, using SARS-CoV-2 original and British variant strains. Both immunoassays confirmed higher anti-RBD Abs levels in vaccinated subjects. Furthermore, despite different anti-RBD Abs median concentrations between the immunoassays, a strong positive correlation with VNT was observed. In conclusion, although the SARS-CoV-2 immune response heterogeneity, the use of immunoassays can help in large-scale monitoring of COVID-19 samples, becoming a valid alternative to VNT test for diagnostic routine laboratories.


Assuntos
Anticorpos Neutralizantes/imunologia , Teste Sorológico para COVID-19/métodos , COVID-19/imunologia , Imunoensaio/métodos , Testes de Neutralização/métodos , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Animais , Anticorpos Antivirais/imunologia , Linhagem Celular , Chlorocebus aethiops , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ligação Proteica/imunologia , Células Vero , Adulto Jovem
7.
Int Immunopharmacol ; 102: 108406, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34862126

RESUMO

The global strategy to control coronavirus disease is based on the availability of COVID-19 vaccines. More information about response to a single dose vaccine could help to better understand and optimize the management of the vaccine campaign. Workers from the University of Rome "Tor Vergata" and the University Hospital of University of Rome "Tor Vergata," were monitored during their vaccination program. Serum samples were collected between the first and second dose and after the second dose. University personnel has been vaccinated with two doses of Vaxzevria vaccine 12 weeks apart, while hospital personnel has been vaccinated with two doses of Comirnaty 3 weeks apart. IgG antibodies (Abs) against the Receptor Binding Domain (RBD) of the virus spike surface glycoprotein and neutralizing antibodies (NT) anti-SARS-CoV-2 that block the interaction between RBD and the surface receptor cellular angiotensin converting enzyme (ACE2) were measured using the CL-series Mindray chemiluminescent assays, respectively. Different amounts of antibodies produced after the two doses of vaccine were found. Individuals with a previous natural infection developed a higher Abs titer. Among the individuals with no history of past SARS-CoV-2 infection, 5% had an Abs level of the same order of magnitude of infected people, suggesting that they acquired the infection in an asymptomatic way. In such individuals, one dose of vaccine may be sufficient to obtain a protective immune response.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Vacinas contra COVID-19/administração & dosagem , COVID-19/prevenção & controle , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19/imunologia , COVID-19/virologia , Vacinas contra COVID-19/provisão & distribuição , Humanos , SARS-CoV-2/imunologia , Vacinação/métodos
8.
Int Immunopharmacol ; 101(Pt B): 108215, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34649115

RESUMO

A large number of immunoassays have been developed to detect specific anti-SARS-CoV-2 antibodies; however, not always they are functional to neutralize the virus. The reference test for the anti-spike neutralizing antibodies (nAbs) ability to counteract the viral infection is the virus neutralization test (VNT). Great interest is developing on reliable serological assays allowing antibodies concentration and antibody protective titer correlation. The aim of our study was to detect nAbs serum levels in paucisymptomatic, symptomatic and vaccinated subjects, to find a cut-off value able to protect from virus infection. nAbs serum levels were detected by a competitive automated immunoassay, in association to VNT with the SARS-CoV-2 original and British variant strains. The median nAbs concentrations were: 281.3 BAU/ml for paucisymptomatics; 769.4 BAU/ml for symptomatics; 351.65 BAU/ml for the vaccinated cohort; 983 BAU/ml considering only the second dose vaccinated individuals. The original strain VNT analysis showed 1:80 median neutralization titers in paucisymptomatic and vaccinated subjects; 1:160 in symptomatic patients; 1:160 in the second dose groups. The British variant VNT analysis showed lower neutralization titers in paucisymptomatic and vaccinated groups (1:40); the same titer in symptomatic patients (1:160); the second dose group confirmed the original strain titer (1:160). In conclusion, our data showed optimal correlations with a proportional increase between neutralizing activity and antibody concentration, making nAbs detection a good alternative to virus neutralization assays, difficult to carry out in routine laboratories. Finally, ROC curve analysis established a cut-off of 408.6 BAU/ml to identify subjects with a low risk of infection.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/sangue , SARS-CoV-2/imunologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Assintomáticas , COVID-19/imunologia , COVID-19/prevenção & controle , Vacinas contra COVID-19 , Feminino , Humanos , Imunoensaio , Masculino , Pessoa de Meia-Idade , Testes de Neutralização , Vacinação , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA