RESUMO
There is growing evidence that surgery can drive an inflammatory response in the brain. However, the mechanisms behind this response are incompletely understood. Here, we investigate the hypotheses that 1. Cerebrospinal fluid (CSF) cytokines increase after vascular surgery and 2. That these changes in CSF cytokines are interrelated. Patients undergoing either open or endovascular elective surgery of the thoracic aorta were invited to participate in this study. Cerebrospinal fluid samples were taken before surgery and on the first post-operative day. These were analysed for the presence of ten cytokines by immunoassay to examine for post-operative changes in cytokine levels. After surgery, there were significant increases in six out of the ten measured CSF cytokines (IL-1ß, 2, 6, 8, 10 and 13). This included changes in both putative pro-inflammatory (IL-1ß, 6 and 8) and putative anti-inflammatory (IL-2, 10 and 13) cytokines. The greatest increases occurred in IL-6 and IL-8, which showed a 63-fold and a 31-fold increase respectively. There was strong intercorrelation between CSF cytokines after the operation. Following surgery on the thoracic aorta, there was a marked increase in CSF cytokines, consistent with a potential role in neuroinflammation. The ten measured cytokines showed intercorrelation after the operation, indicating that a balance between multiple pro- and anti-inflammatory cytokines may be present.
Assuntos
Aorta Torácica , Citocinas , Anti-Inflamatórios , Aorta Torácica/cirurgia , Citocinas/líquido cefalorraquidiano , Humanos , Tórax , Procedimentos Cirúrgicos VascularesRESUMO
BACKGROUND: Stroke occurs in 3% to 8% and silent cerebral infarction in >60% of patients undergoing thoracic endovascular aortic repair (TEVAR). We investigated the utility of a filter cerebral embolic protection device (CEPD) to reduce diffusion-weighted magnetic resonance imaging (DW-MRI) detected cerebral injury and gaseous and solid embolization during TEVAR. METHODS: Patients anatomically suitable underwent TEVAR with CEPD, together with intraoperative transcranial Doppler to detect gaseous and solid high-intensity transient signals (HITSs), pre- and postoperative DW-MRI, and clinical neurologic assessment ≤6 months after the procedure. RESULTS: Ten patients (mean age, 68 years) underwent TEVAR with a CEPD. No strokes or device-related complications developed. The CEPD added a median of 7 minutes (interquartile range [IQR], 5-16 minutes) to the procedure, increased the fluoroscopy time by 3.3 minutes (IQR, 2.4-3.9 minutes), and increased the total procedural radiation by 2.2%. The dose area product for CEPD was 1824 mGy·cm2 (IQR, 1235-3392 mGy·cm2). The average contrast volume used increased by 23 mL (IQR, 24-35 mL). New DW-MRI lesions, mostly in the hindbrain, were identified in seven of nine patients (78%). The median number was 1 (IQR, 1-3), with a median surface area of 6 mm2 (IQR, 3-16 mm2). A total of 2835 HITSs were detected in seven patients: 91% gaseous and 9% solid. The maximum number of HITSs were detected during CEPD manipulation: 142 (IQR, 59-146; 95% gaseous and 5% solid). The maximum number of HITSs during TEVAR occurred during stent deployment: 82 (IQR, 73-142; 81% gas and 11% solid). Solid HITSs were associated with an increase in surface area of new DW-MRI lesions (rs = 0.928; P = .01). Increased gaseous HITSs were associated with new DW-MRI lesions (rs = 0.912; P = .01), which were smaller (<3 mm; r = 0.88; P = .02). Embolic debris was captured in 95% of the filters. The median particle count was 937 (IQR, 146-1687), and the median surface area was 2.66 mm2 (IQR, 0.08-9.18 mm2). CONCLUSIONS: The use of a CEPD with TEVAR appeared to be safe and feasible in this first pilot study and could serve as a useful adjunct to reduce cerebral injury. The significance of gaseous embolization and its role in cerebral injury in TEVAR warrants further investigation.
Assuntos
Aorta Torácica/cirurgia , Dispositivos de Proteção Embólica , Embolia Aérea/prevenção & controle , Procedimentos Endovasculares/instrumentação , Embolia Intracraniana/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aortografia , Imagem de Difusão por Ressonância Magnética , Embolia Aérea/diagnóstico por imagem , Embolia Aérea/etiologia , Procedimentos Endovasculares/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Resultado do Tratamento , Ultrassonografia Doppler TranscranianaRESUMO
The coexistence of abdominal aortic aneurysm (AAA) and congenital pelvic kidney is infrequent. Various treatment modalities have been reported in literature for the treatment of the aforementioned condition. We report a complete endovascular modality for the treatment of this association, especially for high-risk patients. Only one such treatment has been reported before. Compared with this previously reported case, we would like to share our experience with additional prototype testing, before surgery, which provided us with more detailed information about the planning and deployment of the branched endograft. An incidental 7-cm infra renal AAA with the presence of right pelvic kidney was detected on magnetic resonance imaging performed for back pain in a 75-year-old male patient with a history of 2 previous myocardial infarctions and a radical prostatectomy for prostate cancer. He was unfit for open surgery. We report a custom-made fenestrated endograft with prior prototype information used for the repair of a large aneurysm with right pelvic kidney. This procedure is less invasive than any other reported treatment modalities such as open surgery or hybrid procedures. This procedure has an added advantage in that there is no renal ischemia, and recovery is significantly faster.
Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Rim/anormalidades , Artéria Renal/cirurgia , Stents , Idoso , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/métodos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/métodos , Humanos , Rim/diagnóstico por imagem , Imageamento por Ressonância Magnética , Masculino , Modelos Anatômicos , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Desenho de Prótese , Artéria Renal/anormalidades , Artéria Renal/diagnóstico por imagem , Resultado do TratamentoRESUMO
OBJECTIVE: Late thoracic aneurysms develop in 5% to 12% of patients having undergone open repair for coarctation of the aorta (CoA). We report our early results for thoracic endovascular aortic repair for pseudoaneurysms after CoA repair. METHODS: From 2008 to 2013, data regarding demographics, aneurysm morphology, procedure, and follow-up were collected prospectively on all patients treated for pseudoaneurysms after CoA repair. Retrospective analysis of identified patients was then performed. RESULTS: Thirteen patients (six men, seven women) were treated. Patients were a median age, 45 years (interquartile range (IQR), 39-56; range, 27-66 years, and the median time after CoA repair to aneurysm treatment was 34 years (IQR, 24-40 years). All patients had saccular pseudoaneurysms of the aortic arch, with a median aneurysm size of 4.1 cm (IQR, 3.4-5.1 cm). The left subclavian artery (LSCA) was involved in 10 patients and was occluded at presentation in three. Four patients had concurrent LSCA revascularization with carotid-subclavian bypass, one had aortic arch hybrid repair, and the LSCA was intentionally covered in two patients. Patients underwent thoracic endovascular aortic repair using the conformable TAG (6 of 13; W. L. Gore & Associates, Flagstaff, Ariz), Valiant device (4 of 13; Medtronic, Minneapolis, Minn), and a custom-made Relay endograft with LSCA scallop (4 of 13; Bolton Medical, Barcelona, Spain). Technical success was 100%, with satisfactory deployment of the stent grafts in all patients. There was no 30-day mortality, stroke, or paraplegia. Median follow-up was 15 months (IQR, 9-19 months; range, 1-67 months). Two type II endoleaks from an intercostal artery were managed conservatively, and one type Ib endoleak was treated successfully with distal stent extension. CONCLUSIONS: In this cohort, new-generation stent grafts have good early clinical and radiologic outcomes, avoiding the need for redo open surgery. Management of the LSCA can be tailored to individual patients with new stent graft technology. Long-term follow-up of these patients is crucial to understanding whether endovascular management of this cohort is acceptable.
Assuntos
Falso Aneurisma/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Coartação Aórtica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Falso Aneurisma/diagnóstico , Falso Aneurisma/etiologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/etiologia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Endoleak/terapia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
Primary mycotic aneurysms of the aorta are a rare but life-threatening condition. A 59-year-old woman developed a back abscess secondary to an insect bite. A computed tomography scan revealed 3 concomitant mycotic aneurysms, including a rupture. Staged repair was undertaken: immediate open repair for contained rupture of a type IV thoracoabdominal aortic aneurysm, followed by endovascular repair of a descending thoracic aneurysm 3 weeks later and finally an aortic arch hybrid repair of a left subclavian artery aneurysm 16 months later. She remains well postoperatively. There is currently no consensus on the timing of repair or modality of treatment of mycotic aneurysms. Each patient should be treated individually based on aneurysm location, rupture, and comorbidities, as shown by this case.