Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Arch Environ Occup Health ; 76(7): 385-392, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33345756

RESUMO

The objective of this work is to present the key elements in the design of emergency management and response plans in scenarios where there has been loss of containment of chemical agents of acute effect focused in the protection of not routinely exposed in a determined occupational environment. To this purpose, a validation of the current criteria for the management of accidental releases is carried out, taking into account hypothetical risk scenarios. The essential elements of the emergency management system are stated, from a systemic perspective and the corresponding risk control actions; recommendations for their implementation are showed, taking as prototype hydrogen sulfide, a highly toxic gas. Non controlled emissions of toxic gases of acute effect from an occupational standpoint represents a priority because of their human and financial high toll. Design and implementation of an appropriate emergency plan for uncontrollable emissions of toxics chemical agents must be addressed.


Assuntos
Gases/toxicidade , Exposição Ocupacional/prevenção & controle , Indústria de Petróleo e Gás , Gestão de Riscos/normas , Planejamento em Desastres/normas , Humanos , Sulfeto de Hidrogênio/toxicidade , Exposição Ocupacional/efeitos adversos , Exposição Ocupacional/normas , Fatores de Tempo
2.
J Am Board Fam Med ; 28(4): 461-70, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26152436

RESUMO

PURPOSE: The aim of this study was to assess whether chemically intolerant women are at greater risk for having a child with autism spectrum disorders (ASD) or attention deficit hyperactivity disorder (ADHD). METHODS: We conducted a case-control study of chemical intolerance among mothers of children with ASD (n = 282) or ADHD (n = 258) and children without these disorders (n = 154). Mothers participated in an online survey consisting of a validated chemical intolerance screening instrument, the Quick Environmental Exposure and Sensitivity Inventory (QEESI). Cases and controls were characterized by parental report of a professional diagnosis. We used a one-way, unbalanced analysis of variance to compare means across the 3 groups. RESULTS: Both mothers of children with ASD or ADHD had significantly higher mean chemical intolerance scores than did mothers of controls, and they were more likely to report adverse reactions to drugs. Chemically intolerant mothers were 3 times more likely (odds ratio, 3.01; 95% confidence interval, 1.50-6.02) to report having a child with autism or 2.3 times more likely (odds ratio, 2.3; 95% confidence interval, 1.12-5.04) to report a child with ADHD. Relative to controls, these mothers report their children are more prone to allergies (P < .02), have strong food preferences or cravings (P < .003), and have greater sensitivity to noxious odors (P < .04). CONCLUSION: These findings suggest a potential association between maternal chemical intolerance and a diagnosis of ADHD or ASD in their offspring.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade/etiologia , Transtorno Autístico/etiologia , Hipersensibilidade a Drogas/diagnóstico , Mães , Sensibilidade Química Múltipla/diagnóstico , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Estudos Transversais , Feminino , Interação Gene-Ambiente , Inquéritos Epidemiológicos , Humanos , Modelos Logísticos , Pessoa de Meia-Idade , Fatores de Risco , Adulto Jovem
3.
J Occup Environ Hyg ; 2(1): 8-18, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15764519

RESUMO

A total of 625 buildings and outdoor locations in the San Diego, California, area were monitored using the Allergenco Sampl-Air MK-3 impaction sampler or the Zefon Air-O-Cell slit bioaerosol cassette. Locations were classified by rigid criteria as clean commercial, commercial with mold growth, clean residential, residential with water staining, and residential with mold growth. In addition, coastal and inland outdoor locations were measured. Seven categories (total spores, Ascospores/Basidiospores, Cladosporium, Smut/Myxomycetes-like, Aspergillus/Penicillium (AS/PE), Alternaria, and Unidentified/Other) were detected frequently enough that maximum likelihood estimate techniques could be used to determine distribution parameters and, thus, treat these as continuous variables. For total counts (no nondetectables) an analysis of variance was used to examine differences in location means. For the other categories Land's confidence limits were generated and visually compared for differences among locations. For 12 other categories (Curvularia, Dreschlera, Epicoccum, Fusarium, Mildew-like, Pithomyces, Rusts, Stachybotrys, Stemphyllium, Torula, Ulocladium, and Zygomycetes-like), detection generally occurred in less than 10% of samples. These genera were treated as dichotomous (detect/nondetect) data, and Chi-square analyses differentiated between locations. For total counts, values were significantly different on the order of clean < outdoor < moldy. There was a large difference between the moldy and other location classes. For AS/PE, moldy location means were clearly higher than those for clean buildings and outdoors, although the clean and outdoor means could not be differentiated. For all other genera the results tend to indicate little or no ability to discriminate location. For example, there were no differences in the probabilities of detecting Stachybotrys among the various locations. In our study only total counts, usually driven by AS/PE concentrations, had value in determining whether a building is mold contaminated employing our set of rigorous location classification criteria.


Assuntos
Poluição do Ar em Ambientes Fechados/análise , Poluentes Ambientais/análise , Fungos , California , Monitoramento Ambiental , Controle de Qualidade , Sensibilidade e Especificidade , Esporos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA