Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Rev Sci Instrum ; 93(11): 113515, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461442

RESUMO

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure opacities at varying densities and temperatures relevant to the solar interior and thermal cooling rates in white dwarf stars. The typical temperatures reached at NIF range between 150 and 210 eV, which allow these measurements to be performed experimentally. The captured opacities are crucial to validating radiation-hydrodynamic models that are used in astrophysics. The NIF opacity platform has a unique new capability that allows in situ measurement of the sample expansion. The sample expansion data are used to better understand the plasma conditions in our experiments by inferring the sample density throughout the duration of the laser drive. We present the details of the density measurement technique, data analysis, and recent results for Fe and MgO.

2.
Rev Sci Instrum ; 93(11): 113527, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-36461533

RESUMO

The Opacity Spectrometer (OpSpec) used in the National Ignition Facility's opacity experiments measures x-ray spectra from 0.9 to 2.1 keV from the different experimental regions: the backlight source, emission source, and the absorption region with the transmission calculated from these regions. The OpSpec designs have gone through several iterations to help improve the signal-to-noise ratio, remove alternate crystal plane reflections, and improve spectral resolution, which helps to increase the validity of the opacity measurements. However, the source spans well outside the current working spectral range, and higher-order reflections are intrinsic to the crystal, which increases the overall signal seen in the data regions. The recorded data are the convolution of 1st order transmission, higher-order reflections, and the penumbra blurring. This work represents the details for deconvolving the 2nd and 3rd order spectral energy corrections with a penumbral de-blurring to correct the relative measurement of x-ray intensity of different spectral energies and further analysis of datasets relevant to the opacity experiments.

3.
Rev Sci Instrum ; 93(10): 103501, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-36319319

RESUMO

When compared with the National Ignition Facility's (NIF) original soft x-ray opacity spectrometer, which used a convex cylindrical design, an elliptically shaped design has helped to increase the signal-to-noise ratio and eliminated nearly all reflections from alternate crystal planes. The success of the elliptical geometry in the opacity experiments has driven a new elliptical geometry crystal with a spectral range covering 520-1100 eV. When coupled with the primary elliptical geometry, which spans 1000-2100 eV, the new sub-keV elliptical geometry helps to cover the full iron L-shell and major oxygen transitions important to solar opacity experimentation. The new design has been built and tested by using a Henke x-ray source and shows the desired spectral coverage. Additional plans are underway to expand these opacity measurements into a mode of time-resolved detection, ∼1 ns gated, but considerations for the detector size and photometrics mean a crystal geometry redesign. The new low-energy geometry, including preliminary results from the NIF opacity experiments, is presented along with the expansion plans into a time-resolved platform.

4.
Rev Sci Instrum ; 92(7): 075103, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34340426

RESUMO

X-ray films remain a key asset for high-resolution x-ray spectral imaging in high-energy-density experiments conducted at the National Ignition Facility (NIF). The soft x-ray Opacity Spectrometer (OpSpec) fielded at the NIF has an elliptically shaped crystal design that measures x rays in the 900-2100 eV range and currently uses an image plate as the detecting medium. However, Agfa D4 and D3sc x-ray films' higher spatial resolution provides increased spectral resolution to the data over the IP-TR image plates, driving the desire for regular use of x-ray film as a detecting medium. The calibration of Agfa D4 x-ray film for use in the OpSpec is communicated here. These calibration efforts are vital to the accuracy of the NIF opacity measurements and are conducted in a previously un-studied x-ray energy range under a new film development protocol required by NIF. The absolute response of Agfa D4 x-ray film from 705 to 4620 eV has been measured using the Nevada National Security Site Manson x-ray source. A broader range of energies was selected to compare results with previously published data. The measurements were taken using selected anodes, filters, and applied voltages to produce well-defined energy lines.

5.
Rev Sci Instrum ; 92(3): 035108, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820075

RESUMO

The soft x-ray Opacity Spectrometer (OpSpec) used on the National Ignition Facility (NIF) has recently incorporated an elliptically shaped crystal. The original OpSpec used two convex cylindrical crystals for time-integrated measurements of point-projection spectra from 540 to 2100 eV. However, with the convex geometry, the low-energy portion of the spectrum suffered from high backgrounds due to scattered x-rays as well as reflections from alternate crystal planes. An elliptically shaped crystal allows an acceptance aperture at the crossover focus between the crystal and the detector, which reduces background and eliminates nearly all reflections from alternate crystal planes. The current elliptical design is an improvement from the convex cylindrical design but has a usable energy range from 900 to 2100 eV. In addition, OpSpec is currently used on 18 NIF shots/year, in which both crystals are typically damaged beyond reuse, so efficient production of 36 crystals/year is required. Design efforts to improve the existing system focus on mounting reliability, reducing crystal strain to increase survivability between mounting and shot time, and extending the energy range of the instrument down to 520 eV. The elliptical design, results, and future options are presented.

6.
Rev Sci Instrum ; 92(3): 033532, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33820092

RESUMO

Great strides have been made in improving the quality of x-ray radiographs in high energy density plasma experiments, enabled in part by innovations in engineering and manufacturing of integrated circuits and materials. As a consequence, the radiographs of today are filled with a great deal of detail, but few of these features are extracted in a systematic way. Analysis techniques familiar to plasma physicists tend toward brittle 1D lineout or Fourier transform type analyses. The techniques applied to process our data have not kept pace with improvements in the quality of our data. Fortunately, the field of computer vision has a wealth of tools to offer, which have been widely used in industrial imaging and, more recently, adopted in biological imaging. We demonstrate the application of computer vision techniques to the analysis of x-ray radiographs from high energy density plasma experiments, as well as give a brief tutorial on the computer vision techniques themselves. These tools robustly extract 2D contours of shocks, boundaries of inhomogeneities, and secondary flows, thereby allowing for increased automation of analysis, as well as direct and quantitative comparisons with simulations.

7.
Rev Sci Instrum ; 92(3): 033519, 2021 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-33819987

RESUMO

The Opacity Platform on the National Ignition Facility (NIF) has been developed to measure iron opacities at varying densities and temperatures relevant to the solar interior and to verify recent experimental results obtained at the Sandia Z-machine, that diverge from theory. The first set of NIF experiments collected iron opacity data at ∼150 eV to 160 eV and an electron density of ∼7 × 1021 cm-3, with a goal to study temperatures up to ∼210 eV, with electron densities of up to ∼3 × 1022 cm-3. Among several techniques used to infer the temperature of the heated Fe sample, the absolutely calibrated DANTE-2 filtered diode array routinely provides measurements of the hohlraum conditions near the sample. However, the DANTE-2 temperatures are consistently low compared to pre-shot LASNEX simulations for a range of laser drive energies. We have re-evaluated the estimated uncertainty in the reported DANTE-2 temperatures and also the error generated by varying channel participation in the data analysis. An uncertainty of ±5% or better can be achieved with appropriate spectral coverage, channel participation, and metrology of the viewing slot.

8.
Rev Sci Instrum ; 89(10): 10F101, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30399753

RESUMO

A point-projection soft X-ray Opacity Spectrometer (OpSpec) has been implemented to measure X-ray spectra from ∼1 to 2 keV on the National Ignition Facility (NIF). Measurement of such soft X-rays with open-aperture point-projection detectors is challenging because only very thin filters may be used to shield the detector from the hostile environment. OpSpec diffracts X-rays from 540 to 2100 eV off a potassium (or rubidium) acid phthalate (KAP or RbAP) crystal onto either image plates or, most recently, X-ray films. A "sacrificial front filter" strategy is used to prevent crystal damage, while 2 or 3 rear filters protect the data. Since May 2017, OpSpec has been recording X-ray transmission data for iron-magnesium plasmas on the NIF, at "Anchor 1" plasma conditions (temperature ∼150 eV, density ∼7 × 1021 e -/cm3). Upgrades improved OpSpec's performance on 6 NIF shots in August and December 2017, with reduced backgrounds and 100% data return using filter stacks as thin as 2.9 µm (total). Photometric noise is beginning to meet requirements, and further work will reduce systematic errors.

9.
Phys Plasmas ; 24(6): 063301, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29104422

RESUMO

Direct drive implosions of plastic capsules have been performed at the National Ignition Facility to provide a broad-spectrum (500-2000 eV) X-ray continuum source for X-ray transmission spectroscopy. The source was developed for the high-temperature plasma opacity experimental platform. Initial experiments using 2.0 mm diameter polyalpha-methyl styrene capsules with ∼20 µm thickness have been performed. X-ray yields of up to ∼1 kJ/sr have been measured using the Dante multichannel diode array. The backlighter source size was measured to be ∼100 µm FWHM, with ∼350 ps pulse duration during the peak emission stage. Results are used to simulate transmission spectra for a hypothetical iron opacity sample at 150 eV, enabling the derivation of photometrics requirements for future opacity experiments.

10.
Phys Rev Lett ; 117(22): 225001, 2016 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-27925731

RESUMO

Using a large volume high-energy-density fluid shear experiment (8.5 cm^{3}) at the National Ignition Facility, we have demonstrated for the first time the ability to significantly alter the evolution of a supersonic sheared mixing layer by controlling the initial conditions of that layer. By altering the initial surface roughness of the tracer foil, we demonstrate the ability to transition the shear mixing layer from a highly ordered system of coherent structures to a randomly ordered system with a faster growing mix layer, indicative of strong mixing in the layer at a temperature of several tens of electron volts and at near solid density. Simulations using a turbulent-mix model show good agreement with the experimental results and poor agreement without turbulent mix.

11.
Rev Sci Instrum ; 87(11): 11E337, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910339

RESUMO

We present synthetic transmission spectra generated with PrismSPECT utilizing both the ATBASE model and the Los Alamos opacity library (OPLIB) to evaluate whether an alternative choice in atomic data will impact modeling of experimental data from radiation transport experiments using Sc-doped aerogel foams (ScSi6O12 at 75 mg/cm3 density). We have determined that in the 50-200 eV Te range there is a significant difference in the 1s-3p spectra, especially below 100 eV, and for Te = 200 eV above 5000 eV in photon energy. Examining synthetic spectra generated using OPLIB with 300 resolving power reveals spectral sensitivity to Te changes of ∼3 eV.

12.
Rev Sci Instrum ; 87(11): 11D623, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27910379

RESUMO

Recent experiments at the Sandia National Laboratory Z facility have called into question models used in calculating opacity, of importance for modeling stellar interiors. An effort is being made to reproduce these results at the National Ignition Facility (NIF). These experiments require a new X-ray opacity spectrometer (OpSpec) spanning 540 eV-2100 eV with a resolving power E/ΔE > 700. The design of the OpSpec is presented. Photometric calculations based on expected opacity data are also presented. First use on NIF is expected in September 2016.

13.
Rev Sci Instrum ; 85(9): 093501, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25273720

RESUMO

A very large area (7.5 mm(2)) laser-driven x-ray backlighter, termed the Big Area BackLighter (BABL) has been developed for the National Ignition Facility (NIF) to support high energy density experiments. The BABL provides an alternative to Pinhole-Apertured point-projection Backlighting (PABL) for a large field of view. This bypasses the challenges for PABL in the equatorial plane of the NIF target chamber where space is limited because of the unconverted laser light that threatens the diagnostic aperture, the backlighter foil, and the pinhole substrate. A transmission experiment using 132 kJ of NIF laser energy at a maximum intensity of 8.52 × 10(14) W/cm(2) illuminating the BABL demonstrated good conversion efficiency of >3.5% into K-shell emission producing ~4.6 kJ of high energy x rays, while yielding high contrast images with a highly uniform background that agree well with 2D simulated spectra and spatial profiles.

14.
Phys Rev Lett ; 89(16): 165003, 2002 Oct 14.
Artigo em Inglês | MEDLINE | ID: mdl-12398730

RESUMO

Observations of a radiative-precursor shock that evolves from a purely hydrodynamic system are presented. The radiative precursor is observed in low-density SiO2 aerogel foam using x-ray absorption spectroscopy. A plastic slab, shocked and accelerated by high-intensity laser irradiation, drives the shock which then produces the radiative precursor. The length and temperature profile of the radiative precursor are examined as the intensity of the laser is varied.

15.
Phys Rev Lett ; 89(8): 085001, 2002 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-12190474

RESUMO

Laser-driven experiments are described which probe the interaction of a very strong shock with a spherical density inhomogeneity. The interaction is viewed from two orthogonal directions enabling visualization of both the initial distortion of the sphere into a double vortex ring structure as well as the onset of an azimuthal instability that ultimately results in the three-dimensional breakup of the ring. The experimental results are compared with 3D numerical simulations and are shown to be in remarkable agreement with the incompressible theory of Widnall et al. [J. Fluid Mech. 66, 35 (1974)].

16.
Hum Genet ; 90(1-2): 133-8, 1992.
Artigo em Inglês | MEDLINE | ID: mdl-1427769

RESUMO

The role of major genes in the expression of serum uric acid (UA) levels was investigated in data collected from five clinics of the Lipid Research Clinics (LRC) family study. Over 2,000 randomly ascertained individuals were analyzed. The UA distributions were homogeneous among the five LRC clinics and between the parental and offspring generations. This result suggested that the data could be pooled across clinics, thereby increasing the statistical power associated with larger sample sizes for testing various null hypotheses. Additionally, a mixture of three normal distributions best characterized the combined-clinics data. Segregation patterns were examined in the untransformed data, as well as in a more conservative (and biologically meaningful) log transformation. Prior to log transformation, both major and multifactorial effects were detected. The major effect was not transmissible, i.e., was not compatible with Mendelian transmission, and accounted for 39% of the variance in UA levels. However, after the log transform was applied to the data and the segregation analysis was repeated, support for the major effect disappeared altogether and only the multifactorial component remained, accounting for 50% of the variation in offspring and 19% in patients.


Assuntos
Interpretação Estatística de Dados , Variação Genética , Ácido Úrico/sangue , Adolescente , Adulto , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Genéticos , Estados Unidos
17.
Hum Biol ; 63(4): 419-39, 1991 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-1889794

RESUMO

The familial aggregation of lipids [total cholesterol (CH) and triglyceride (TG)] and lipoproteins [high-density lipoprotein cholesterol (HDL) and low-density lipoprotein cholesterol (LDL)] was investigated in families ascertained through both random and nonrandom probands in the Minnesota Lipid Research Clinic Family Study. Nonrandom proband ascertainment was based on single selection through truncation for hyperlipidemia at an earlier screening. A path model was used to investigate the nature of familial resemblance using appropriate adjustments for ascertainment and to determine whether random and hyperlipidemic samples are heterogeneous with regard to the multifactorial model. The results suggest that parameter estimates are consistent with those from previous studies in which only random families were used and that random and nonrandom samples are homogeneous with regard to the path model for CH and LDL. However, for TG and HDL the random and hyperlipidemic samples are significantly heterogeneous. This heterogeneity would be observed if familial hypertriglyceridemia and/or familial hypoalphalipoproteinemia segregates predominantly in the hyperlipidemic rather than in the random sample, as on might expect.


Assuntos
Hiperlipidemias/genética , Modelos Genéticos , Modelos Estatísticos , Linhagem , Bandeamento Cromossômico , Triagem de Portadores Genéticos , Genótipo , Humanos , Hiperlipidemias/sangue , Hiperlipidemias/epidemiologia , Funções Verossimilhança , Fenótipo , Fatores de Risco
18.
Am J Med Genet ; 39(3): 270-7, 1991 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-1867276

RESUMO

We examined the familial aggregation of lipids [total cholesterol (CH) and triglyceride (TG)] and lipoproteins [high-density lipoprotein cholesterol (HDL) and low-density lipoprotein cholesterol (LDL)] in families ascertained through random and nonrandom probands in the Stanford Lipid Research Clinics Family Study. Nonrandom probands were selected because their lipid levels at a prior screening visit exceeded a certain prespecified threshold. The statistical method is based on selection through indirect truncation on a correlated trait (in which the likelihood function is conditioned on the actual event that the proband's value is beyond the threshold). This method allows for estimation of the path model parameters in randomly and nonrandomly ascertained families jointly and separately, thus enabling tests of heterogeneity between the two types of samples. The results suggest that the multifactorial transmission is homogeneous in the random and hyperlipidemic samples for CH. However, the evidence for heterogeneity is moderate for LDL, marked HDL, and mixed for TG. The general pattern of observed results is for somewhat higher genetic heritabilities in the random than nonrandom samples, which is compatible with a higher prevalence in the random sample of certain dyslipoproteinemias associated with nonelevated lipids. Substantial genetic heritability is found for CH, HDL, and LDL, with somewhat lower estimates for TG. Cultural heritability is low but significant for all four traits. Little or no spouse resemblance or nontransmitted shared sibship effects are seen. In contrast to the findings from previous studies, little or no parental cultural transmission is seen.


Assuntos
Hiperlipidemias/genética , Lipídeos/genética , Lipoproteínas/genética , Adulto , Idoso , California/epidemiologia , Feminino , Humanos , Hiperlipidemias/epidemiologia , Lipídeos/sangue , Lipoproteínas/sangue , Masculino , Pessoa de Meia-Idade , Modelos Genéticos , Linhagem , Fatores de Risco , Estudos de Amostragem
19.
Hum Hered ; 41(2): 107-21, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1855782

RESUMO

The aggregation of lipids [total cholesterol (CH) and triglyceride (TG)] and lipoproteins [high-density lipoprotein cholesterol (HDL) and low-density lipoprotein cholesterol (LDL)] in families ascertained through random and nonrandom probands in the Iowa Lipid Research Clinics family study was examined. Nonrandom probands were selected because their lipid levels (at a prior screening visit) exceeded a certain pre-specified threshold. The statistical method conditions the likelihood function on the actual event that the proband's value is beyond the threshold. This method allows for estimation of the path model parameters in randomly and nonrandomly ascertained families jointly and separately, thus enabling tests of heterogeneity between the two types of samples. Marked heterogeneity between the random and the hyperlipidemic samples is detected in the multifactorial transmission for TG and HDL, and moderate heterogeneity is detected for CH and LDL, with a pattern of higher genetic heritability estimates in the random than nonrandom samples. The observed pattern of heterogeneity is compatible with a higher prevalence in the random sample of certain dyslipoproteinemias that are associated with nonelevated lipids. For the random samples, genetic heritabilities are higher for CH and HDL (about 60%) than for TG and LDL (about 50%). For the nonrandom samples those estimates are about 45, 40, 35 and 30% for HDL, CH, LDL and TG, respectively. Little to no cultural (familial environmental) heritability is evident for CH and LDL, although 10-20% of the phenotypic variance is due to cultural factors for TG and HDL. These results suggest that the etiologies for lipids and lipoproteins may be quite different in random versus hyperlipidemic samples.


Assuntos
HDL-Colesterol/sangue , LDL-Colesterol/sangue , Hiperlipidemias/sangue , Núcleo Familiar , Triglicerídeos/sangue , Adulto , HDL-Colesterol/genética , LDL-Colesterol/genética , Jejum , Feminino , Humanos , Hiperlipidemias/genética , Iowa , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Fenótipo , Vigilância da População , População Rural , Meio Social , Triglicerídeos/genética , População Branca
20.
Am J Med Genet ; 36(2): 219-25, 1990 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-2368810

RESUMO

This study represents the first formal examination for heterogeneity in the familial aggregation of fasting serum uric acid (UA) levels. Data from 5 clinics (Cincinnati, Stanford, Iowa, Minnesota, and Oklahoma) participating in the Lipid Research Clinics (LRC) family study, which included a total of 685 nuclear families (N = 2,146), were analyzed. Heterogeneity among the clinics in familial resemblance was detected. However, this heterogeneity could not be attributed to differences in distributional properties (such as means and variances) or to path model parameters representing latent genetic or cultural (environmental) components associated with UA levels. Intergenerational differences in genetic heritabilities were found, with higher offspring (h2 = 43%) than parent (h2z2 = 16%) estimates, but no generational differences were detected for cultural heritability (c2 = 0.09). Equal maternal and paternal cultural transmission was found, and effects due to extra sibling environments and to marital resemblance were both significant. These results show no clear indication as to the source of the heterogeneity observed for familial resemblance of UA levels in randomly selected data. This question should be further investigated, especially in clinical samples such as dyslipoproteinemic families.


Assuntos
Frequência do Gene , Lipídeos , Ácido Úrico/sangue , Adulto , Centros Comunitários de Saúde , Simulação por Computador , Jejum , Feminino , Variação Genética , Humanos , Masculino , Modelos Genéticos , Linhagem , Estados Unidos , Ácido Úrico/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA