Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Ann Neurol ; 94(5): 848-855, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37584452

RESUMO

INTRODUCTION: Computed tomography perfusion (CTP) has played an important role in patient selection for mechanical thrombectomy (MT) in acute ischemic stroke. We aimed to investigate the agreement between perfusion parametric maps of 3 software packages - RAPID (RapidAI-IschemaView), Viz CTP(Viz.ai), and e-CTP(Brainomix) - in estimating baseline ischemic core volumes of near completely/completely reperfused patients. METHODS: We retrospectively reviewed a prospectively maintained MT database to identify patients with anterior circulation large vessel occlusion strokes (LVOS) involving the internal carotid artery or middle cerebral artery M1-segment and interpretable CTP maps treated during September 2018 to November 2019. A subset of patients with near-complete/complete reperfusion (expanded thrombolysis in cerebral infarction [eTICI] 2c-3) was used to compare the pre-procedural prediction of final infarct volumes. RESULTS: In this analysis of 242 patients with LVOS, RAPID and Viz CTP relative cerebral blood flow (rCBF) < 30% values had substantial agreement (ρ = 0.767 [95% confidence interval [CI] = 0.71-0.81]) as well as for RAPID and e-CTP (ρ = 0.668 [95% CI = 0.61-0.71]). Excellent agreement was seen for time to maximum of the residue function (Tmax ) > 6 seconds between RAPID and Viz CTP (ρ = 0.811 [95% CI = 0.76-0.84]) and substantial for RAPID and e-CTP (ρ = 0.749 [95% CI = 0.69-0.79]). Final infarct volume (FIV) prediction (n = 136) was substantial in all 3 packages (RAPID ρ = 0.744; Viz CTP ρ = 0.711; and e-CTP ρ = 0.600). CONCLUSION: Perfusion parametric maps of the RAPID, Viz CTP, and e-CTP software have substantial agreement in predicting final infarct volume in near-completely/completely reperfused patients. ANN NEUROL 2023;94:848-855.


Assuntos
Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Infarto Cerebral , Trombectomia/métodos , Circulação Cerebrovascular/fisiologia , Perfusão , Software , Imagem de Perfusão/métodos
2.
Interv Neuroradiol ; : 15910199231176310, 2023 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-37226428

RESUMO

BACKGROUND: As compared to single-phase CTA (sCTA), multi-phase CTA (mCTA) has been shown to more accurately estimate collateral flow in acute ischemic stroke (AIS). We sought to determine the characterization of poor collaterals across the three different phases of the mCTA. We also attempted to establish the optimal arterio-venous contrast timing parameters on sCTA that would prevent false positive reads of poor collateral status. METHODS: We retrospectively screened consecutive patients admitted for possible thrombectomy from February 2018 to June 2019. Only cases with intracranial internal carotid artery (ICA) or main trunk of the middle cerebral artery (MCA) occlusion and both baseline mCTA and CT Perfusion available were included. Mean Hounsfield units (HU) of torcula and torcula/patent ICA ratio were used for the arterio-venous timing analysis. RESULTS: Of the 105 patients included, 35 (34%) received IV-tPA treatment and 65 (61.9%) underwent mechanical thrombectomy. A total of 20 patients (19%) had poor collaterals on the third-phase CTA (ground-truth). The first-phase CTA often underestimated collateral score (37/105 [35%], p < 0.01), however there were no significant differences across the second- and third-phases (5/105[5%], p = 0.06. Venous opacification Youden's J point for identifying suboptimal sCTAs was found to be 207.9HU in the torcula (65% sensitivity,65% specificity) and 66.74% for torcula/patent ICA ratio (51% sensitivity,73% specificity). CONCLUSION: A dual-phase CTA is significantly similar to a mCTA assessment of collateral score and may be applied at community-based centers. Absolute or relative thresholds for torcula opacification may be used to identify poor bolus-scan timing thus preventing erroneous assumptions of poor collaterals on sCTA.

3.
J Neurointerv Surg ; 15(2): 153-156, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35172982

RESUMO

BACKGROUND: Carotid webs (CaW) are now recognized as a cause of ischemic stroke in young patients. The thromboembolic potential appears related to the CaW's morphology and consequent impact on local flow dynamics. We aim to evaluate the reliability of different measurement methods for the quantification of CaW and their relationship to symptomatic status, presence of large vessel occlusion stroke (LVOS), clot burden and final infarct volume. METHODS: This was a retrospective analysis of the local comprehensive stroke center CaW database (September 2014-July 2019). CT angiograms (CTAs) were reviewed independently by two raters, blinded to the clinical information and laterality of the stroke/transient ischemic attack. CaW were quantified with 1-D (length), 2-D (area) and 3-D (volume) measurements via Osirix software. Final infarct volume was calculated on MRI. Patients with superimposed CaW thrombus and no repeat imaging were excluded. RESULTS: Forty-eight CaW (37 symptomatic and 11 contralateral/asymptomatic) in 38 patients were included. Mean age (±SD) was 48.7 (±8.5) years, 78.9% were women and 77.1% were black. Inter-rater agreement was 0.921 (p<0.001) for 1-D, 0.930 (p<0.001) for 2-D, and 0.937 (p<0.001) for 3-D CaW measurements. When comparing symptomatic with asymptomatic CaW, mean web length was 3.2 mm versus 2.5 mm (p<0.02), median area was 5.8 versus 5.0 mm2 (p=0.35) and median volume was 15.0 versus 10.6 mm3 (p<0.04), respectively. CaW with a thinner profile (longer intraluminal projection compared with the base) were more likely to be symptomatic (0.67±0.17 vs 0.88±0.37; p=0.01). Average CaW 1-D and final infarct volume had a weak but positive association (Κ=0.230, p<0.05), while no association among web measurements and the presence of LVOS or clot burden was observed. CONCLUSION: CaW dimension quantification (1-D, 2-D and 3-D) is highly reproducible. Linear and volumetric measurements were more strongly associated with symptoms. The impact of CaW size on the presence of LVOS, clot burden and final infarct volume is unclear.


Assuntos
Arteriopatias Oclusivas , Isquemia Encefálica , AVC Isquêmico , Acidente Vascular Cerebral , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Estudos Retrospectivos , Reprodutibilidade dos Testes , Acidente Vascular Cerebral/etiologia , Artérias Carótidas , Arteriopatias Oclusivas/complicações , AVC Isquêmico/complicações , Infarto/complicações , Isquemia Encefálica/etiologia
4.
J Neurointerv Surg ; 13(2): 124-129, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32381523

RESUMO

BACKGROUND: First pass reperfusion (FPR) has been established as a key performance metric in mechanical thrombectomy (MT). The impact of FPR may be more relevant in fast progressors. We aim to study the impact of baseline Alberta Stroke Program Early CT Score (ASPECTS) on non-contrast CT and hypoperfusion intensity ratio (HIR) on CT perfusion on clinical outcomes after FPR. METHODS: A prospective MT database was reviewed for patients with isolated occlusion of the intracranial internal carotid artery and/or middle cerebral artery M1 segment who underwent MT with complete reperfusion (modified Thrombolyis in Cerebral Infarction score 2c-3) from January 2012 to May 2019. The overall population was divided into ASPECTS >7 versus ≤7 and the subgroup of patients with baseline CT perfusion was divided into HIR <0.3 versus ≥0.3. Univariable and multivariable analyses were performed to establish the predictors of 90-day functional independence (modified Rankin Scale (mRS) ≤2) in each subgroup. RESULTS: A total of 436 patients were included in the analyses. FPR was achieved in 254 (58.3%) patients. ASPECTS modified the effect of FPR on clinical outcomes, with FPR predicting good outcomes in patients with ASPECTS ≤7 (46% vs 29%, adjusted OR 3.748; 95% CI 1.590 to 8.838, p=0.003) while no significant effect was detected in those with ASPECTS >7 (62.3% vs 53.1%, adjusted OR 1.372; 95% CI 0.798 to 2.358, p=0.25). Similarly, FPR predicted good outcomes in patients with HIR ≥0.3 (54.8% vs 41.9%, adjusted OR 2.204; 95% CI 1.148 to 4.233, p=0.01) but not in those with HIR <0.3 (62.9% vs 52.8%, adjusted OR 1.524; 95% CI 0.592 to 3.920, p=0.38). CONCLUSIONS: The impact of FPR on functional outcomes is highly dependent on baseline imaging characteristics, with a more prominent influence in patients presenting with lower ASPECTS and/or higher HIR.


Assuntos
Artéria Carótida Interna/fisiologia , Artéria Carótida Interna/cirurgia , Artéria Cerebral Média/fisiologia , Artéria Cerebral Média/cirurgia , Recuperação de Função Fisiológica/fisiologia , Trombectomia/métodos , Idoso , Idoso de 80 Anos ou mais , Artéria Carótida Interna/diagnóstico por imagem , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/diagnóstico por imagem , Estudos Prospectivos , Reperfusão/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
5.
J Neurointerv Surg ; 13(7): 599-604, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32737205

RESUMO

BACKGROUND: The first-pass effect (FPE) has emerged as a key metric for efficacy in mechanical thrombectomy (MT). The hyperdense vessel sign (HDVS) on non-contrast head CT (NCCT) indicates a higher clot content of red blood cells. OBJECTIVE: To assess whether the HDVS could serve as an imaging biomarker for guiding first-line device selection in MT. METHODS: A prospective MT database was reviewed for consecutive patients with anterior circulation large vessel occlusion stroke who underwent thrombectomy with stent retriever (SR) or contact aspiration (CA) as first-line therapy between January 2012 and November 2018. Pretreatment NCCT scans were evaluated for the presence of HDVS. The primary outcome was FPE (modified Thrombolysis in Cerebral Infarction score 2c/3). The primary analysis was the interaction between HDVS and thrombectomy modality on FPE. Secondary analyses aimed to evaluate the predictors of FPE. RESULTS: A total of 779 patients qualified for the analysis. HDVS and FPE were reported in 473 (60.7%) and 286 (36.7%) patients, respectively. The presence of HDVS significantly modified the effect of thrombectomy modality on FPE (p=0.01), with patients with HDVS having a significantly higher rate of FPE with a SR (41.3% vs 22.2%, p=0.001; adjusted OR 2.11 (95% CI 1.20 to 3.70), p=0.009) and non-HDVS patients having a numerically better response to CA (41.4% vs 33.9%, p=0.28; adjusted OR 0.58 (95% CI 0.311 to 1.084), p=0.088). Age (OR 1.01 (95% CI 1.00 to 1.02), p=0.04) and balloon guide catheter (OR 2.08 (95% CI 1.24 to 3.47), p=0.005) were independent predictors of FPE in the overall population. CONCLUSION: Our data suggest that patients with HDVS may have a better response to SRs than CA for the FPE. Larger confirmatory prospective studies are warranted.


Assuntos
Isquemia Encefálica/cirurgia , AVC Isquêmico/cirurgia , Paracentese/métodos , Stents , Trombectomia/métodos , Idoso , Isquemia Encefálica/diagnóstico por imagem , Feminino , Humanos , AVC Isquêmico/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
6.
BMJ Case Rep ; 12(5)2019 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-31061190

RESUMO

Internal carotid artery dissection (ICAD) is caused by the disruption of the tunica intima, with the formation of an intramural haematoma that can cause stenosis or occlusion of the artery's lumen, leading to reduced blood flow and secondary thrombus formation. Up to two-thirds of patients with ICAD show ophthalmological symptoms or signs, which are, frequently, the first manifestations of this clinical condition, often preceding for weeks the neurological signs of cerebral infarction. Central retinal artery occlusion (CRAO) is a rare complication of ICAD, secondary either to haemodynamic compromise, with ocular hypoperfusion and reverse flow within the ophthalmic artery, or to thromboembolic events, in rarer cases. We report a case of CRAO secondary to a spontaneous ICAD, in an otherwise healthy middle-aged patient.


Assuntos
Dissecação da Artéria Carótida Interna/diagnóstico , Pressão Intraocular/fisiologia , Isquemia/diagnóstico , Oclusão da Artéria Retiniana/diagnóstico , Dissecação da Artéria Carótida Interna/fisiopatologia , Dissecação da Artéria Carótida Interna/terapia , Angiografia Cerebral , Embolização Terapêutica , Feminino , Cefaleia , Humanos , Isquemia/fisiopatologia , Isquemia/terapia , Pessoa de Meia-Idade , Oclusão da Artéria Retiniana/fisiopatologia , Oclusão da Artéria Retiniana/terapia , Trombectomia , Resultado do Tratamento
7.
J Craniomaxillofac Surg ; 47(7): 1060-1064, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31080052

RESUMO

PURPOSE: Management of orbital fractures continues to present some difficulties, particularly regarding the prediction of late complications. Radiographic assessment provides a detailed evaluation, but the results lack consistency to be considered a standard factor in the decision-making process. Studies focusing on reliability of post-operative imaging are lacking. MATERIALS AND METHODS: We performed a retrospective study using patients from a major trauma center with unilateral orbital floor fracture who underwent surgery. Using three-dimensional volume assessment software, we performed a volume calculation and determined the intra- and interreader variation by intraclass correlation coefficient analysis. RESULTS: Twenty-four orbits were assessed. Mean orbital volume (SD) was 24.02 (2,43) cm3 for reader 1 and 24.08 (2,51) cm3 for reader 2. The intraclass correlation coefficient (95% CI) was 0.95 (0.91-0.98) between readers and 0.96 (0.91-0.98) for intra-reader variability. Normal and reconstructed orbits assessed separately also showed very high correlation coefficient for both intra- and inter-subject variability. CONCLUSION: Results show an almost perfect agreement of volume assessment between readers. The presence of reconstruction material does not seem to add variability. Although reproducible and reliable, radiological volume assessments have not yet shown a clear correlation with clinical outcomes and post-operative management decisions should be based mainly on clinical findings.


Assuntos
Enoftalmia , Fraturas Orbitárias , Humanos , Imageamento Tridimensional , Órbita , Fraturas Orbitárias/diagnóstico por imagem , Procedimentos de Cirurgia Plástica , Reprodutibilidade dos Testes , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA