Pathogenic microorganisms are a major concern in indoor environments, particularly in sensitive facilities such as hospitals, due to their potential to cause nosocomial infections. This study evaluates the concentration of airborne bacteria and fungi in the University Hospital Complex of Albacete (Spain), comparing the results with recent literature. Staphylococcus is identified as the most prevalent bacterial genus with a percentage distribution of 35%, while Aspergillus represents the dominant fungal genus at 34%. The lack of high Technology Readiness Levels (TRL 6, TRL 7) for effective indoor air purification requires research efforts to bridge this knowledge gap. A screening of disinfection technologies for pathogenic airborne microorganisms such as bacteria and fungi is conducted. The integration of filtration, irradiation or and (electro)chemical gas treatment systems in duct flows is discussed to enhance the design of the air-conditioning systems for indoor air purification. Concerns over microbial growth have led to recent studies on coating commercial fibrous air filters with antimicrobial particles (silver nanoparticles, iron oxide nanowires) and polymeric materials (polyaniline, polyvinylidene fluoride). Promising alternatives to traditional short-wave UV-C energy for disinfection include LED and Far-UVC irradiation systems. Additionally, research explores the use of TiO2 and TiO2 doped with metals (Ag, Cu, Pt) in filters with photocatalytic properties, enabling the utilization of visible or solar light. Hybrid photocatalysis, combining TiO2 with polymers, carbon nanomaterials, or MXene nanomaterials, enhances the photocatalytic process. Chemical treatment systems such as aerosolization of biocidal agents (benzalkonium chloride, hydrogen peroxide, chlorine dioxide or ozone) with their possible combination with other technologies such as adsorption, filtration or photocatalysis, are also tested for gas disinfection. However, the limited number of studies on the use of electrochemical technology poses a challenge for further investigation into gas-phase oxidant generation, without the formation of harmful by-products, to raise its TRL for effectively inactivating airborne microorganisms in indoor environments.


Assuntos
Poluição do Ar em Ambientes Fechados , Nanopartículas Metálicas , Humanos , Prata , Raios Ultravioleta , Desinfecção/métodos , Poluição do Ar em Ambientes Fechados/prevenção & controle
2.
Environ Res ; 216(Pt 1): 114458, 2023 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-36181895

RESUMO

The composition and concentration of airborne microorganisms in hospital indoor air has been reported to contain airborne bacteria and fungi concentrations ranged 101-103 CFU/m3 in inpatients facilities which mostly exceed recommendations from the World Health Organization (WHO). In this work, a deeper knowledge of the performance of airborne microorganisms would allow improving the designs of the air-conditioning installations to restrict hospital-acquired infections (HAIs). A solution containing Escherichia coli (E. coli) as a model of airborne bacteria was nebulized using the Collison nebulizer to simulate bioaerosols in various hospital areas such as patients' rooms or bathrooms. Results showed that the bioaerosol source had a significant influence on the airborne bacteria concentrations since 4.00 102, 6.84 103 and 1.39 104 CFU mL-1 were monitored during the aerosolization for 10 min of urine, saliva and urban wastewater, respectively. These results may be explained considering the quite narrow distribution profile of drop sizes around 1.10-1.29 µm obtained for urban wastewater, with much vaster distribution profiles during the aerosolization of urine or saliva. The airborne bacteria concentration may increase up to 107 CFU mL-1 for longer sampling times and higher aerosolization pressures, causing several cell damages. The cell membrane damage index (ID) can vary from 0 to 1, depending on the genomic DNA releases from bacteria. In fact, the ID of E. coli was more than two times higher (0.33 vs. 0.72) when increasing the pressure of air flow was applied from 1 to 2 bar. Finally, the ventilation air flow also affected the distribution of bioaerosols due to its direct relationship with the relative humidity of indoor air. Specifically, the airborne bacteria concentration diminished almost below 3-logs by applying more than 10 L min-1 during the aerosolization of urine due to their inactivation by an increase in their osmotic pressure.