1.
Postepy Kardiol Interwencyjnej ; 19(3): 270-276, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37854960

RESUMO

Introduction: Transcatheter closure of paravalvular leak (PVL) is still a demanding procedure due to the complex anatomy of PVL channels and risk of interference between the implanted occluder and surrounding structures. Efforts are made to improve procedural outcomes in transcatheter structural heart interventions by establishing treatment strategy in advance with the use of 3D-printed physical models based on data obtained from cardiac computed tomography (CT) studies. Aim: In this feasibility study 3D printing of PVL models based on data recorded during transesophageal echocardiography (TEE) examinations was evaluated. Material and methods: 3D-TEE data of patients with significant PVL around mitral valve prostheses were used to prepare 3D models. QLab software was used to export DICOM images in Cartesian DICOM format of each PVL with the surrounding tissue. Image segmentation was performed in Slicer, a free, open-source software package used for imaging research. Models were printed to actual size with the Polyjet printer with a transparent, rigid material. We measured dimensions of PVLs both in TEE recordings and printed 3D models. The results were correlated with sizes of occluding devices used to close the defects. Results: In 7 out of 8 patients, there was concordance between procedurally implanted occluders and pre-procedurally matched closing devices based on 3D-printed models. Conclusions: 3D-printing from 3D-TEE is technically feasible. Both shape and location of PVLs are preserved during model preparation and printing. It remains to be tested whether 3D printing would improve outcomes of percutaneous PVL closure.

2.
Anatol J Cardiol ; 27(10): 573-579, 2023 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-37288866

RESUMO

BACKGROUND: Paravalvular leaks can be detected in almost 15% of patients after mitral valve prosthesis implantation. This complication can result in congestive heart failure and hemolysis. Despite advancements in non-invasive imaging, percutaneous closure of paravalvular leaks is not always successful. Therefore, efforts are made to improve treatment outcomes by using 3D-printed models of defects as pre-procedural support for interventional cardiologists. METHODS: Retrospectively, 3D-transesophageal echocardiography recordings of 8 patients with clinically significant mitral paravalvular leaks were analyzed. Qlab Software was used to export DICOM images of each paravalvular leak channel, including surrounding tissue. Image segmentation was performed in 3D Slicer, a free, open-source software package used for imaging research. Models were printed to actual size with the poly jet Stratasys Objet 30 printer with a transparent, rigid material. RESULTS: Duration of model preparation and printing, as well as the total cost, was calculated. Mean total time of model preparation was 430.5 ± 196 minutes. CONCLUSION: 3D-printing from 3D-transesophageal echocardiography is technically feasible. Both shape and location of paravalvular leaks are preserved during model preparation and printing. It remains to be tested if 3D-printing would improve outcomes of percutaneous paravalvular leaks closure.


Assuntos
Ecocardiografia Tridimensional , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Valva Mitral/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Ecocardiografia Transesofagiana , Estudos Retrospectivos , Próteses Valvulares Cardíacas/efeitos adversos , Resultado do Tratamento , Impressão Tridimensional , Cateterismo Cardíaco/métodos , Falha de Prótese
3.
Catheter Cardiovasc Interv ; 87(3): 478-87, 2016 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-25963541

RESUMO

BACKGROUND: Transcatheter paravalvular leak closure (TPVLC) offers a viable alternative to reoperation but optimal technical strategy is still to be defined. We present a prospective TPVLC registry in which safety and efficacy of multi-plug, single-stage approach were assessed. METHODS: Patients with heart failure (HF) symptoms caused by PVL were qualified for TPVLC by Heart Team. Ante- or retrograde access was employed for mitral while retrograde only for aortic PVLs. Two to 4 AVP 3 devices were simultaneously implanted into each PVL. Endpoints were defined according to VARC-2. RESULTS: From 64 referred patients 49, with either mechanical valves (n = 30) or stented bioprostheses, were eligible for TPVLC. PVL location was mitral (n = 29) or aortic (n = 20). In aortic group acute procedural success (APS) ratio was 100% and no MACCEs occurred. In mitral group, first-attempt TPVLC was successful in 22 cases (4/4 in transapical and 18/25 in transseptal access). Second-attempt transapical procedure followed transseptal failure in 5 patients. Mitral TPVLC ultimately proved efficient in 89.7% with 76.5% APS. Cumulatively, TPVLC was accomplished in 46 subjects (93.9%) with 78% APS. When successful, it led to a significant decrease of NT-proBNP concentration and HF symptoms regression. Periprocedural safety endpoints were met in three patients and included non-disabling stroke, and two access site-related complications. In device failure group two patients died (end-stage HF) and two others were rehospitalized. CONCLUSION: TPVLC with simultaneous deployment of multiple AVP III occluders is feasible with high device success rate and no significant periprocedural complications. The clinical benefits of reduction of HF symptoms and hemolysis are evident after 30 days and persist up to 1 year without recurrence of PVL.


Assuntos
Insuficiência da Valva Aórtica/terapia , Cateterismo Cardíaco/instrumentação , Insuficiência Cardíaca/terapia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Insuficiência da Valva Mitral/terapia , Falha de Prótese , Dispositivos de Oclusão Vascular , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Biomarcadores/sangue , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Ecocardiografia Doppler em Cores , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/fisiopatologia , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemólise , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Peptídeo Natriurético Encefálico/sangue , Readmissão do Paciente , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Sistema de Registros , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
4.
J Invasive Cardiol ; 25(5): 226-31, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23645046

RESUMO

OBJECTIVES: To evaluate the transcatheter paravalvular leak closure (TPVLC) aptitude to reduce manifestations of heart failure caused by aortic paravalvular leak (PVL). BACKGROUND: TPVLC is a valuable alternative to reoperation. While technical feasibility of the method is well established, data on long-term clinical outcome are less abundant. METHODS: We launched a prospective registry of patients with clinically significant aortic PVL. They were scheduled for TPVLC with Amplatzer vascular plug (AVP) II and III devices serving as occluders. The efficacy and safety were monitored at 6-month follow-up exam. RESULTS: The occluder deployment reached a success rate of nearly 90%. Following the procedure, we recorded significant improvement both in terms of patient functional capacity and echocardiographic determinants of left ventricular performance. Simultaneously, NT-proBNP plasma concentration and hemolysis markers decreased. Only local complications related to puncture site occurred. CONCLUSIONS: Heart failure caused by aortic PVL can be safely and efficiently treated with TPVLC using AVP II and III devices as occluders.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Procedimentos Endovasculares/métodos , Insuficiência Cardíaca/prevenção & controle , Dispositivo para Oclusão Septal , Adulto , Idoso , Insuficiência da Valva Aórtica/diagnóstico por imagem , Biomarcadores/sangue , Ecocardiografia , Feminino , Fluoroscopia , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/sangue , Fragmentos de Peptídeos/sangue , Estudos Prospectivos , Sistema de Registros , Resultado do Tratamento
6.
Cardiol J ; 18(4): 434-6, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21769825

RESUMO

Coronary artery aneurysm is a rare congenital or acquired anomaly. The commonest location of coronary artery aneurysms is the right coronary artery and they are found slightly more often in males. We report an unusual case of multiple and extremely large aneurysms, therefore potentially at risk of rupture or thrombosis.


Assuntos
Aneurisma Coronário/diagnóstico , Idoso , Procedimentos Cirúrgicos Cardíacos , Aneurisma Coronário/cirurgia , Angiografia Coronária/métodos , Humanos , Masculino , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Cardiol J ; 16(5): 455-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19753525

RESUMO

Bicuspid aortic valve is one of the most common congenital cardiac anomalies and it may be accompanied by other cardiovascular anomalies. Sinus of Valsalva aneurysm is a rare anomaly in adult population, but it coexists with bicuspid aortic valve quite often. This report describes a 57 years-old patient who had a bicuspid aortic valve accompanied by unruptured Valsalva sinus aneurysm with significant left anterior narrowing and who underwent successful surgery with ascending aorta and aortic valve replacement as well as coronary by-pass grafting.


Assuntos
Aneurisma Aórtico/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular , Ponte de Artéria Coronária , Estenose Coronária/cirurgia , Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca , Seio Aórtico/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Valva Aórtica/anormalidades , Valva Aórtica/diagnóstico por imagem , Aortografia/métodos , Angiografia Coronária , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Seio Aórtico/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
J Am Coll Cardiol ; 54(16): 1500-11, 2009 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-19699048

RESUMO

OBJECTIVES: The aim of the study was to evaluate early and late outcomes after percutaneous coronary intervention (PCI) of unprotected left main coronary artery disease (ULMCA) and to compare bare-metal stent (BMS) and drug-eluting stent (DES) subgroups. BACKGROUND: PCI is an increasingly utilized method of revascularization in patients with ULMCA. METHODS: This multicenter prospective registry included 252 patients after ULMCA stenting enrolled between March 1997 and February 2008. Non-ST-segment elevation acute coronary syndrome was diagnosed in 58% of patients; ST-segment elevation myocardial infarction cases were excluded. Drug-eluting stents were implanted in 36.2% of patients. RESULTS: Major adverse cardiovascular and cerebral events (MACCE) occurred in 12 (4.8%) patients during the 30-day period, which included 4 (1.5%) deaths. After 12 months there were 17 (12.1%) angiographically confirmed cases of restenosis. During long-term follow-up (1 to 11 years, mean 3.8 years) there were 64 (25.4%) MACCE and 35 (13.9%) deaths. The 5- and 10-year survival rates were 78.1% and 68.9%, respectively. Despite differences in demographical and clinical data in favor of BMS patients, unmatched analysis showed a significantly lower MACCE rate in DES patients (25.9% vs. 14.9%, p = 0.039). This difference was strengthened after propensity score matching. The DES lowered both mortality and MACCE for distal ULMCA lesions when compared with BMS. Ejection fraction <50% was the only independent risk factor influencing long-term survival. CONCLUSIONS: Stenting of ULMCA is feasible and offers good long-term outcome. Implantation of DES for ULMCA decreased the risk of long-term MACCE, and particularly improved survival in patients with distal ULMCA disease.


Assuntos
Angioplastia Coronária com Balão/métodos , Estenose Coronária/terapia , Sistema de Registros , Stents , Idoso , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/epidemiologia , Estenose Coronária/diagnóstico , Estenose Coronária/mortalidade , Eletrocardiografia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Polônia/epidemiologia , Estudos Prospectivos , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento
9.
J Am Coll Cardiol ; 51(5): 538-45, 2008 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-18237682

RESUMO

OBJECTIVES: The purpose of this study was to compare the early and late results of percutaneous and surgical revascularization of left main coronary artery stenosis. BACKGROUND: Unprotected left main coronary artery (ULMCA) stenting is being investigated as an alternative to bypass surgery. METHODS: We randomly assigned 105 patients with ULMCA stenosis to percutaneous coronary intervention (PCI; 52 patients) or coronary artery bypass grafting (CABG; 53 patients). The primary end point was the change in left ventricular ejection fraction (LVEF) 12 months after the intervention. Secondary end points included 30-day major adverse events (MAE), major adverse cardiac and cerebrovascular events (MACCE), length of hospitalization, target vessel failure (TVF), angina severity and exercise tolerance after 1 year, and total and MACCE-free survival. RESULTS: A significant increase in LVEF at the 12-month follow-up was noted only in the PCI group (3.3 +/- 6.7% after PCI vs. 0.5 +/- 0.8% after CABG; p = 0.047). Patients performed equally well on stress tests, and angina status improved similarly in the 2 groups. PCI was associated with a lower 30-day risk of MAE (p < 0.006) and MACCE (p = 0.03) and shorter hospitalizations (p = 0.0007). Total and MACCE-free 1-year survival was comparable. Left main TVF was similar in the 2 groups. During the 28.0 +/- 9.9-month follow-up, there were 3 deaths in the PCI group and 7 deaths in the CABG group (p = 0.08). CONCLUSIONS: Patients with ULMCA disease treated with PCI had favorable early outcomes in comparison with the CABG group. At 1 year, LVEF had improved significantly only in the PCI group. After more than 2 years, MACCE-free survival was similar in both groups with a trend toward improved survival after PCI.


Assuntos
Ponte de Artéria Coronária , Estenose Coronária/terapia , Stents , Angina Pectoris/epidemiologia , Angioplastia Coronária com Balão , Doenças Cardiovasculares/epidemiologia , Estenose Coronária/mortalidade , Estenose Coronária/fisiopatologia , Estenose Coronária/cirurgia , Teste de Esforço , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Stents/efeitos adversos , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento
12.
Kardiol Pol ; 64(3): 268-72; discussion 273-4, 2006 Mar.
Artigo em Inglês, Polonês | MEDLINE | ID: mdl-16583327

RESUMO

INTRODUCTION: In-stent restenosis still remains a serious clinical problem. Local intramural drug delivery (LDD -- Local Drug Delivery) seems to be an interesting alternative to drug-eluting stents (DES). AIM: The aim of the study was to assess the safety and effectiveness of local intramural paclitaxel administration in the treatment of recurrent in-stent restenosis (ISR). METHODS: Five patients were enrolled in the study (3 men, mean age 50+/-7 years) with at least a second episode of ISR within the same stent. Percutaneous coronary angioplasty was performed on a total of 11 vessel segments. Remedy delivery catheters (Boston Scientific) were used for balloon angioplasty. Inflation pressure was calibrated to obtain a balloon/vessel lumen ratio of 1.1:1. Then the pressure was lowered to 3 atmospheres and 100 microg of paclitaxel diluted in 2 ml of 0.9% NaCl was given over 60 seconds under the pressure of 2-3 atmospheres. This dose was used for each 10 mm of lesions. Control coronary angiography was performed six months after the procedure. RESULTS: In all patients effective target vessel revascularisation was achieved. No adverse events were observed in the periprocedural period or during the 6-month follow-up period. Control angiography revealed ISR in three segments (27.2%) and in-stent late lumen loss of 0.21+/-0.93 mm. CONCLUSIONS: Local intramural paclitaxel delivery is a safe and effective method of ISR treatment. The optimal paclitaxel dose should be established in further studies.


Assuntos
Reestenose Coronária/tratamento farmacológico , Oclusão de Enxerto Vascular/prevenção & controle , Paclitaxel/administração & dosagem , Angioplastia Coronária com Balão/métodos , Implante de Prótese Vascular , Materiais Revestidos Biocompatíveis , Reestenose Coronária/etiologia , Reestenose Coronária/terapia , Feminino , Seguimentos , Oclusão de Enxerto Vascular/etiologia , Humanos , Injeções Intralesionais/métodos , Masculino , Pessoa de Meia-Idade , Recidiva , Stents/efeitos adversos , Resultado do Tratamento
13.
Kardiol Pol ; 64(1): 1-6; discussion 7, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16444619

RESUMO

INTRODUCTION: Stent implantation for the unprotected left main coronary artery (ULMCA) is regarded as controversial and coronary heart disease with LMCA stenosis still remains a basic indication for bypass surgery. Although there is no doubt that the risk of stent implantation for LMCA lesions is low, there are still limited data on long-term outcomes. There have been no reports so far answering the question whether ULMCA stenting ensures adequate coronary blood flow in the vessel. AIM: Assessment of the effect of LMCA flow restoration with stenting on the coronary flow reserve assessed by an exercise test, as well as on left ventricular function and angina in patients followed for 12 months after the procedure. METHODS: The study population included 62 patients (17 women and 45 men) aged 61.4+/-11.1 (35-84 years) who underwent coronary angioplasty with elective ULMCA stenting. In all patients, serial echocardiography (before and 1, 3, 6, and 12 months after the procedure) and the exercise test according to the Bruce protocol (1, 3, 6, 12 months after the procedure) were carried out. Routine coronary angiography was performed 3 to 6 months after the procedure. Fifty-nine patients (95.2%) survived a 12-month period. In 24 (38.7%) patients major adverse cardiac events (MACE) occurred. In-stent restenosis was observed in 13 patients; in 11 of them repeated PCI was performed and 2 of them underwent CABG. One patient after repeated PCI required CABG. RESULTS: Severity of angina, evaluated according to the CCS scale, decreased significantly in the 12-month follow-up period as compared with the preprocedural period (p <0.00001). The mean baseline left ventricular ejection fraction was 51.6+/-12.5%. It increased to 53.8+/-12.8% (p <0.02) at 6 months and remained at this level at 12 months. The mean exercise test time was 7.0+/-3.4 minutes in the first month after ULMCA stenting, and in the sixth and the twelfth month of follow-up it increased to 7.6+/-3.4 minutes (p <0.002) and 7.8+/-3.2 minutes (p <0.05), respectively. The metabolic equivalent task (MET) value did not change significantly during the observation period. CONCLUSIONS: Restoration of the physiological blood flow in the unprotected left main coronary artery with stent implantation is associated with a significant reduction of angina, significant improvement of the left ventricular systolic function and preservation of exercise capacity in long-term follow-up.


Assuntos
Angina Pectoris/cirurgia , Angioplastia Coronária com Balão/métodos , Vasos Coronários/cirurgia , Stents , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA