RESUMO
REM sleep behaviour disorder (RBD) is a parasomnia characterised by dream-enacting behaviour with loss of muscle atonia during REM sleep and is a prodromal feature of α-synucleinopathies like Parkinson's disease, dementia with Lewy bodies, and multiple system atrophy. Although cortical-to-subcortical connectivity is well-studied in RBD, cerebellar and subcortical nuclei reciprocal connectivity is less established. Nonetheless, it could be relevant since RBD pathology involves brainstem structures with an ascending gradient. In this study, we utilised resting-state functional MRI to investigate 13 people with isolated RBD (iRBD), 17 with Parkinson's disease and 16 healthy controls. We investigated the connectivity between the basal ganglia, thalamus and regions of the cerebellum. The cerebellum was segmented using a functional atlas, defined by a resting-state network-based parcellation, rather than an anatomical one. Controlling for age, we found a significant group difference (F4,82 = 5.47, pFDR = 0.017) in cerebellar-thalamic connectivity, with iRBD significantly lower compared to both control and Parkinson's disease. Specifically, cerebellar areas involved in this connectivity reduction were related to the default mode, language and fronto-parietal resting-state networks. Our findings show functional connectivity abnormalities in subcortical structures that are specific to iRBD and may be relevant from a pathophysiological standpoint. Further studies are needed to investigate how connectivity changes progress over time and whether specific changes predict disease course or phenoconversion.
RESUMO
Background: Diagnosing Dementia with Lewy Bodies (DLB) remains a challenge in clinical practice. The use of 123I-ioflupane (DaTscan™) SPECT imaging, which detects reduced dopamine transporter (DAT) uptake-a key biomarker in DLB diagnosis-could improve diagnostic accuracy. However, DAT imaging is underutilized despite its potential, contributing to delays and suboptimal patient management. Methods: This review evaluates DLB diagnostic practices and challenges faced within the U.S. by synthesizing information from current literature, consensus guidelines, expert opinions, and recent updates on DaTscan FDA filings. It contrasts DAT SPECT with alternative biomarkers, provides recommendations for when DAT SPECT imaging may be indicated and discusses the potential of emerging biomarkers in enhancing diagnostic approaches. Results: The radiopharmaceutical 123I-ioflupane for SPECT imaging was initially approved in Europe (2000) and later in the US (2011) for Parkinsonism/Essential Tremor. Its application was extended in 2022 to include the diagnosis of DLB. DaTscan's diagnostic efficacy for DLB, with its sensitivity, specificity, and predictive values, confirms its clinical utility. However, US implementation faces challenges such as insurance barriers, costs, access issues, and regional availability disparities. Conclusion: 123I-ioflupane SPECT Imaging is indicated for DLB diagnosis and differential diagnosis of Alzheimer's Disease, particularly in uncertain cases. Addressing diagnostic obstacles and enhancing physician-patient education could improve and expedite DLB diagnosis. Collaborative efforts among neurologists, geriatric psychiatrists, psychologists, and memory clinic staff are key to increasing diagnostic accuracy and care in DLB management.
RESUMO
OBJECTIVE: To investigate hypothalamic atrophy and its clinical correlates in multiple system atrophy (MSA) in-vivo. BACKGROUND: MSA is characterized by autonomic dysfunction and parkinsonian/cerebellar manifestations. The hypothalamus regulates autonomic and homeostatic functions and is also involved in memory and learning processes. METHODS: 11 MSA, 18 Parkinson's Disease (PD) and 18 Healthy Controls (HC) were included in this study. A validated and automated hypothalamic segmentation tool was applied to 3D-T1-weighted images acquired on a 3T MRI scanner. MSA hypothalamic volumes were compared to those of PD and HC. Furthermore, the association between hypothalamic volumes and scores of autonomic, depressive, sleep and cognitive manifestations were investigated. RESULTS: Posterior hypothalamus volume was reduced in MSA compared to controls (t = 2.105, p = 0.041) and PD (t = 2.055, p = 0.046). Total hypothalamus showed a trend towards a reduction in MSA vs controls (t = 1.676, p = 0.101). Reduced posterior hypothalamus volume correlated with worse MoCA scores in the parkinsonian (MSA + PD) group and in each group separately, but not with autonomic, sleep, or depression scores. CONCLUSIONS: In-vivo structural hypothalamic involvement may be present in MSA. Reduced posterior hypothalamus volume, which includes the mammillary bodies and lateral hypothalamus, is associated with worse cognitive functioning. Larger studies on hypothalamic involvement in MSA and its clinical correlates are needed.
Assuntos
Hipotálamo , Imageamento por Ressonância Magnética , Atrofia de Múltiplos Sistemas , Humanos , Atrofia de Múltiplos Sistemas/diagnóstico por imagem , Atrofia de Múltiplos Sistemas/patologia , Atrofia de Múltiplos Sistemas/fisiopatologia , Masculino , Feminino , Hipotálamo/diagnóstico por imagem , Hipotálamo/patologia , Hipotálamo/fisiopatologia , Idoso , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico por imagem , Doença de Parkinson/patologia , Doença de Parkinson/fisiopatologiaRESUMO
INTRODUCTION: Clinical parkinsonism is a core diagnostic feature for mild cognitive impairment with Lewy bodies (MCI-LB) but can be challenging to identify. A five-item scale derived from the Unified Parkinson's Disease Rating Scale (UPDRS) has been recommended for the assessment of parkinsonism in dementia. This study aimed to determine whether the five-item scale is effective to identify parkinsonism in MCI. METHODS: Participants with MCI from two cohorts (n = 146) had a physical examination including the UPDRS and [123I]-FP-CIT SPECT striatal dopaminergic imaging. Participants were classified as having clinical parkinsonism (P+) or no parkinsonism (P-), and with abnormal striatal dopaminergic imaging (D+) or normal imaging (D-). The five-item scale was the sum of UPDRS tremor at rest, bradykinesia, action tremor, facial expression, and rigidity scores. The ability of the scale to differentiate P+D+ and P-D- participants was examined. RESULTS: The five-item scale had an AUROC of 0.92 in Cohort 1, but the 7/8 cut-off defined for dementia had low sensitivity to identify P+D+ participants (sensitivity 25%, specificity 100%). Optimal sensitivity and specificity was obtained at a 3/4 cut-off (sensitivity 83%, specificity 88%). In Cohort 2, the five-item scale had an AUROC of 0.97, and the 3/4 cut-off derived from Cohort 1 showed sensitivity of 100% and a specificity of 82% to differentiate P+D+ from P-D- participants. The five-item scale was not effective in differentiating D+ from D- participants. CONCLUSIONS: The five-item scale is effective to identify parkinsonism in MCI, but a lower threshold must be used in MCI compared with dementia.
Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Doença por Corpos de Lewy , Transtornos Parkinsonianos , Humanos , Doença por Corpos de Lewy/diagnóstico , Doença por Corpos de Lewy/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Disfunção Cognitiva/metabolismo , Tomografia Computadorizada de Emissão de Fóton Único , Doença de Alzheimer/metabolismoRESUMO
BACKGROUND: Positron emission tomography-magnetic resonance (PET-MR) attenuation correction is challenging because the MR signal does not represent tissue density and conventional MR sequences cannot image bone. A novel zero echo time (ZTE) MR sequence has been previously developed which generates signal from cortical bone with images acquired in 65 s. This has been combined with a deep learning model to generate a synthetic computed tomography (sCT) for MR-only radiotherapy. This study aimed to evaluate this algorithm for PET-MR attenuation correction in the pelvis. METHODS: Ten patients being treated with ano-rectal radiotherapy received a [Formula: see text]F-FDG-PET-MR in the radiotherapy position. Attenuation maps were generated from ZTE-based sCT (sCTAC) and the standard vendor-supplied MRAC. The radiotherapy planning CT scan was rigidly registered and cropped to generate a gold standard attenuation map (CTAC). PET images were reconstructed using each attenuation map and compared for standard uptake value (SUV) measurement, automatic thresholded gross tumour volume (GTV) delineation and GTV metabolic parameter measurement. The last was assessed for clinical equivalence to CTAC using two one-sided paired t tests with a significance level corrected for multiple testing of [Formula: see text]. Equivalence margins of [Formula: see text] were used. RESULTS: Mean whole-image SUV differences were -0.02% (sCTAC) compared to -3.0% (MRAC), with larger differences in the bone regions (-0.5% to -16.3%). There was no difference in thresholded GTVs, with Dice similarity coefficients [Formula: see text]. However, there were larger differences in GTV metabolic parameters. Mean differences to CTAC in [Formula: see text] were [Formula: see text] (± standard error, sCTAC) and [Formula: see text] (MRAC), and [Formula: see text] (sCTAC) and [Formula: see text] (MRAC) in [Formula: see text]. The sCTAC was statistically equivalent to CTAC within a [Formula: see text] equivalence margin for [Formula: see text] and [Formula: see text] ([Formula: see text] and [Formula: see text]), whereas the MRAC was not ([Formula: see text] and [Formula: see text]). CONCLUSION: Attenuation correction using this radiotherapy ZTE-based sCT algorithm was substantially more accurate than current MRAC methods with only a 40 s increase in MR acquisition time. This did not impact tumour delineation but did significantly improve the accuracy of whole-image and tumour SUV measurements, which were clinically equivalent to CTAC. This suggests PET images reconstructed with sCTAC would enable accurate quantitative PET images to be acquired on a PET-MR scanner.
RESUMO
BACKGROUND: Positron Emission Tomography-Magnetic Resonance (PET-MR) scanners could improve ano-rectal radiotherapy planning through improved Gross Tumour Volume (GTV) delineation and enabling dose painting strategies using metabolic measurements. This requires accurate quantitative PET images acquired in the radiotherapy treatment position. PURPOSE: This study aimed to evaluate the impact on GTV delineation and metabolic parameter measurement of using novel Attenuation Correction (AC) maps that included the radiotherapy flat couch, coil bridge and anterior coil to see if they were necessary. METHODS: Seventeen ano-rectal radiotherapy patients received a 18 F $\mathrm{^{18}F}$ -FluoroDeoxyGlucose PET-MR scan in the radiotherapy position. PET images were reconstructed without ( CTAC std $\mathrm{CTAC_{std}}$ ) and with ( CTAC cba $\mathrm{CTAC_{cba}}$ ) the radiotherapy hardware included. Both AC maps used the same Computed Tomography image for patient AC. Semi-manual and threshold GTVs were delineated on both PET images, the volumes compared and the Dice coefficient calculated. Metabolic parameters: Standardized Uptake Values SUV max $\mathrm{SUV_{max}}$ , SUV mean $\mathrm{SUV_{mean}}$ and Total Lesion Glycolysis (TLG) were compared using paired t-tests with a Bonferroni corrected significance level of p = 0.05 / 8 = 0.006 $p = 0.05/8 = 0.006$ . RESULTS: Differences in semi-manual GTV volumes between CTAC cba $\mathrm{CTAC_{cba}}$ and CTAC std $\mathrm{CTAC_{std}}$ were approaching statistical significance (difference - 15.9 % ± 1.6 % $-15.9\%\pm 1.6\%$ , p = 0.007 $p = 0.007$ ), with larger differences in low FDG-avid tumours ( SUV mean < 8.5 g mL - 1 $\mathrm{SUV_{mean}} < 8.5\;\mathrm{g\: mL^{-1}}$ ). The CTAC cba $\mathrm{CTAC_{cba}}$ and CTAC std $\mathrm{CTAC_{std}}$ GTVs were concordant with Dice coefficients 0.89 ± 0.01 $0.89 \pm 0.01$ (manual) and 0.98 ± 0.00 $0.98 \pm 0.00$ (threshold). Metabolic parameters were significantly different, with SUV max $\mathrm{SUV_{max}}$ , SUV mean $\mathrm{SUV_{mean}}$ and TLG differences of - 11.5 % ± 0.3 % $-11.5\%\ \pm 0.3\%$ ( p < 0.001 $p < 0.001$ ), - 11.6 % ± 0.3 % $-11.6\% \pm 0.3\%$ ( p < 0.001 $p < 0.001$ ) and - 13.7 % ± 0.6 % $-13.7\%\ \pm 0.6\%$ ( p = 0.003 $p = 0.003$ ) respectively. The TLG difference resulted in 1/8 rectal cancer patients changing prognosis group, based on literature TLG cut-offs, when using CTAC cba $\mathrm{CTAC_{cba}}$ rather than CTAC std $\mathrm{CTAC_{std}}$ . CONCLUSIONS: This study suggests that using AC maps with the radiotherapy hardware included is feasible for patient imaging. The impact on tumour delineation was mixed and needs to be evaluated in larger cohorts. However using AC of the radiotherapy hardware is important for situations where accurate metabolic measurements are required, such as dose painting and treatment prognostication.
Assuntos
Imagem Multimodal , Tomografia por Emissão de Pósitrons , Humanos , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Fluordesoxiglucose F18 , Compostos RadiofarmacêuticosRESUMO
BACKGROUND AND OBJECTIVES: Progressive nigrostriatal pathway degeneration occurs in individuals with dementia with Lewy bodies (LB). Our objective was to investigate whether repeat 123[I]-N-(3-fluoropropyl)-2ß-carboxymethoxy-3ß-(4-iodophenyl) nortropane (FP-CIT) single photon emission computed tomography (SPECT) can identify progressive dopaminergic loss in mild cognitive impairment (MCI) with Lewy bodies (MCI-LB). METHODS: Individuals with MCI-LB and MCI due to Alzheimer disease (MCI-AD) underwent comprehensive clinical assessment, 123[I]-FP-CIT SPECT at baseline and annual reviews, and baseline cardiac 123 iodine metaiodobenzylguanidine (I-MIBG). Mixed-effects models were used to investigate changes in 123[I]-FP-CIT specific binding ratio (SBR) in the striatum for each diagnostic group compared with controls. The time interval to the development of a quantitatively abnormal 123[I]-FP-CIT SPECT in the possible and probable MCI-LB groups was determined as the time it took for these groups to reach a striatal uptake 2 SDs below aged-matched controls. Test-retest variation was assessed using baseline and repeat scans in controls. RESULTS: We recruited 20 individuals with MCI-AD, 11 with possible MCI-LB, 25 with probable MCI-LB, and 29 age-matched controls. The mean time between baseline and the final image was 1.6 years (SD = 0.9, range 1.0-4.3). The annual estimated change in SBR was 0.23 for controls (95% CI -0.07 to 0.53), -0.09 (-0.55 to 0.36) for MCI-AD, -0.50 (-1.03 to 0.04) for possible MCI-LB, and -0.48 (-0.89 to -0.06) for probable MCI-LB. The median annual percentage change in SBR in MCI-LB was -5.6% (95% CI -8.2% to -2.9%) and 2.1% (-3.5% to 8.0%) for MCI-AD. The extrapolated time for a normal scan to become abnormal was 6 years. Controls and MCI-AD showed no significant change in dopaminergic binding over time. The mean test-retest variation in controls was 12% (SD 5.5%), which cautions against overinterpretation of small changes on repeat scanning. DISCUSSION: Progressive dopaminergic loss in the striatum is detectable using 123[I]-FP-CIT SPECT in MCI-LB at a group level. In clinical practice, individual change in striatal 123[I]-FP-CIT uptake seems to be of limited diagnostic value because of high test-retest variation. CLASSIFICATION OF EVIDENCE: This study provides Class II evidence that longitudinal declines in striatal uptake measured using 123[I]-FP-CIT SPECT are associated with MCI due to Lewy body disease but not MCI due to Alzheimer disease.
Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Doença por Corpos de Lewy , Humanos , Idoso , Doença de Alzheimer/metabolismo , Imageamento Dopaminérgico , Tropanos/metabolismo , Doença por Corpos de Lewy/complicações , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Disfunção Cognitiva/metabolismoRESUMO
OBJECTIVES: Needle electromyography (EMG) may be used to characterise the severity of the injury in acute peripheral facial nerve palsy (FNP) to predict recovery and guide management, but its prognostic value and clinical utility remain controversial. The aim of this systematic review was to evaluate the role of EMG to prognosticate the recovery of facial motor function in patients with acute peripheral FNP. DESIGN: A comprehensive search strategy was applied in PubMed, Embase, and Web of Science based on Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. The main outcome measure was the accuracy of EMG in predicting long-term facial function at least 6 months following symptom onset. RESULTS: Eleven studies were included comprising 3837 participants, with 91.6% of these diagnosed with Bell's palsy (BP). In BP patients, the positive predictive value and negative predictive value for a good outcome based on EMG findings ranged from 82.1% to 100% and 66.7% to 80.5%, respectively, with two out of three studies finding that EMG remained a significant predictor of the outcome on multivariate analysis. Three studies addressed the role of EMG in non-idiopathic FNP with two of these studies supporting EMG to predict prognosis. CONCLUSIONS: EMG is a useful tool to gain insight into the likely outcome to guide management decisions and counsel patients on their expectations, particularly in BP. However, given inconsistencies in its application and lack of evidence around non-idiopathic FNP, it should not currently be relied on to predict recovery. Ultimately, its prognostic value and widespread adoption are dependent on the implementation of a clear and standardised protocol in future high-quality studies and routine clinical settings.
Assuntos
Paralisia de Bell , Paralisia Facial , Humanos , Eletromiografia/métodos , Nervo Facial , Paralisia Facial/diagnóstico , Paralisia de Bell/diagnóstico , FaceRESUMO
PURPOSE: Inhibition of monocarboxylate transporter (MCT) 1-mediated lactate transport may have cytostatic and/or cytotoxic effects on tumor cells. We report results from the dose-escalation part of a first-in-human trial of AZD3965, a first-in-class MCT1 inhibitor, in advanced cancer. PATIENTS AND METHODS: This multicentre, phase I, dose-escalation and dose-expansion trial enrolled patients with advanced solid tumors or lymphoma and no standard therapy options. Exclusion criteria included history of retinal and/or cardiac disease, due to MCT1 expression in the eye and heart. Patients received daily oral AZD3965 according to a 3+3 then rolling six design. Primary objectives were to assess safety and determine the MTD and/or recommended phase II dose (RP2D). Secondary objectives for dose escalation included measurement of pharmacokinetic and pharmacodynamic activity. Exploratory biomarkers included tumor expression of MCT1 and MCT4, functional imaging of biological impact, and metabolomics. RESULTS: During dose escalation, 40 patients received AZD3965 at 5-30 mg once daily or 10 or 15 mg twice daily. Treatment-emergent adverse events were primarily grade 1 and/or 2, most commonly electroretinogram changes (retinopathy), fatigue, anorexia, and constipation. Seven patients receiving ≥20 mg daily experienced dose-limiting toxicities (DLT): grade 3 cardiac troponin rise (n = 1), asymptomatic ocular DLTs (n = 5), and grade 3 acidosis (n = 1). Plasma pharmacokinetics demonstrated attainment of target concentrations; pharmacodynamic measurements indicated on-target activity. CONCLUSIONS: AZD3965 is tolerated at doses that produce target engagement. DLTs were on-target and primarily dose-dependent, asymptomatic, reversible ocular changes. An RP2D of 10 mg twice daily was established for use in dose expansion in cancers that generally express high MCT1/low MCT4).
Assuntos
Antineoplásicos , Neoplasias , Humanos , Neoplasias/tratamento farmacológico , Neoplasias/induzido quimicamente , Pirimidinonas/farmacologia , Antineoplásicos/efeitos adversos , Tiofenos/farmacologia , Dose Máxima Tolerável , Relação Dose-Resposta a DrogaRESUMO
Background: Fluorine-18 fluorodeoxyglucose (FDG)-positron emission tomography/computed tomography (PET/CT) is widely used for staging high-grade lymphoma, with the time to evaluate such studies varying depending on the complexity of the case. Integrating artificial intelligence (AI) within the reporting workflow has the potential to improve quality and efficiency. The aims of the present study were to evaluate the influence of an integrated research prototype segmentation tool implemented within diagnostic PET/CT reading software on the speed and quality of reporting with variable levels of experience, and to assess the effect of the AI-assisted workflow on reader confidence and whether this tool influenced reporting behaviour. Methods: Nine blinded reporters (three trainees, three junior consultants and three senior consultants) from three UK centres participated in a two-part reader study. A total of 15 lymphoma staging PET/CT scans were evaluated twice: first, using a standard PET/CT reporting workflow; then, after a 6-week gap, with AI assistance incorporating pre-segmentation of disease sites within the reading software. An even split of PET/CT segmentations with gold standard (GS), false-positive (FP) over-contour or false-negative (FN) under-contour were provided. The read duration was calculated using file logs, while the report quality was independently assessed by two radiologists with >15 years of experience. Confidence in AI assistance and identification of disease was assessed via online questionnaires for each case. Results: There was a significant decrease in time between non-AI and AI-assisted reads (median 15.0 vs. 13.3â min, p < 0.001). Sub-analysis confirmed this was true for both junior (14.5 vs. 12.7â min, p = 0.03) and senior consultants (15.1 vs. 12.2â min, p = 0.03) but not for trainees (18.1 vs. 18.0â min, p = 0.2). There was no significant difference between report quality between reads. AI assistance provided a significant increase in confidence of disease identification (p < 0.001). This held true when splitting the data into FN, GS and FP. In 19/88 cases, participants did not identify either FP (31.8%) or FN (11.4%) segmentations. This was significantly greater for trainees (13/30, 43.3%) than for junior (3/28, 10.7%, p = 0.05) and senior consultants (3/30, 10.0%, p = 0.05). Conclusions: The study findings indicate that an AI-assisted workflow achieves comparable performance to humans, demonstrating a marginal enhancement in reporting speed. Less experienced readers were more influenced by segmentation errors. An AI-assisted PET/CT reading workflow has the potential to increase reporting efficiency without adversely affecting quality, which could reduce costs and report turnaround times. These preliminary findings need to be confirmed in larger studies.
RESUMO
SUMMARY: Existing automated objective grading systems either fail to consider the face's complex three-dimensional morphology or have poor feasibility and usability. Consumer-based red, green, and blue depth sensors or smartphone integrated three-dimensional hardware can inexpensively collect detailed four-dimensional facial data in real time but are yet to be incorporated into a practical system. This study aimed to evaluate the feasibility of a proof-of-concept automated four-dimensional facial assessment system using a red/green/blue depth sensor (OpenFAS) for use in a standard clinical environment. This study was performed on healthy adult volunteers and patients with facial nerve palsy. The setup consists of the Intel (Santa Clara, Calif.) RealSense SR300 connected to a laptop running the OpenFAS application. The subject sequentially mimics the facial expressions shown on screen. Each frame is landmarked and automatic anthropometric calculations are performed. Any errors during each session were noted. Landmarking accuracy was estimated by comparing the ground-truth position of landmarks annotated manually with those placed automatically. Eighteen participants were included in the study, nine healthy participants and nine patients with facial nerve palsy. Each session was standardized at approximately 106 seconds. A total of 61.8 percent of landmarks were automatically annotated within approximately 1.575 mm of their ground-truth locations. The findings support that OpenFAS is usable and feasible in routine settings, laying down the critical groundwork for a facial assessment system that addresses the shortcomings of existing tools. The iteration of OpenFAS presented in this study is nascent; future work, including improvements to landmarking accuracy, analyses components, and red/green/blue depth technology, is required before clinical application.
Assuntos
Paralisia Facial , Imageamento Tridimensional , Face/anatomia & histologia , Face/diagnóstico por imagem , Expressão Facial , Paralisia Facial/diagnóstico , Humanos , Imageamento Tridimensional/métodosRESUMO
INTRODUCTION: Amyloid-ß (Aß) deposition is common in dementia with Lewy bodies (DLB) and has been associated with more rapid disease progression. An effective biomarker that identified the presence of significant brain Aß in people with DLB may be useful to identify and stratify participants for research studies and to inform prognosis in clinical practice. Plasma biomarkers are emerging as candidates to fulfil this role. METHODS: Thirty-two participants with DLB had brain amyloid (18F-florbetapir) PET, of whom 27 also had an MRI to enable the calculation of 18F-florbetapir SUVR. Plasma Aß42/40, phosphorylated tau (p-tau181), glial fibrillary acidic protein (GFAP) and neurofilament light (NfL) were measured using single molecule array (Simoa). The plasma biomarkers were investigated for correlation with 18F-florbetapir SUVR, discriminant ability to identify Aß-positive cases based on a predefined SUVR threshold of 1.10 and correlation with subsequent cognitive decline over one year. RESULTS: All four plasma markers significantly correlated with 18F-florbetapir SUVR (|ß| = 0.40-0.49; p < .05). NfL had the greatest area under the receiver operating characteristic curve to identify Aß-positive cases (AUROC 0.84 (95% CI 0.66, 1); ß = 0.46, p = .001), whereas Aß42/40 had the smallest (AUROC 0.73 (95% CI 0.52, 0.95); ß = -0.47, p = .01). Accuracy was highest when combining all four biomarkers (AUROC 0.92 (95% CI 0.80, 1)). Lower plasma Aß42/40 was significantly associated with more rapid decline in cognition (ß = 0.53, p < .01). CONCLUSIONS: Plasma biomarkers have the potential to identify Aß deposition in DLB. Further work in other cohorts is required to determine and validate optimal cut-offs for these biomarkers.
Assuntos
Amiloidose , Disfunção Cognitiva , Doença por Corpos de Lewy , Peptídeos beta-Amiloides/metabolismo , Biomarcadores , Disfunção Cognitiva/complicações , Proteína Glial Fibrilar Ácida , Humanos , Doença por Corpos de Lewy/complicações , Proteínas de Neurofilamentos , Fragmentos de Peptídeos , Tomografia por Emissão de Pósitrons , Proteínas tauRESUMO
PURPOSE: Some studies have suggested that cardiac [123I]metaiodobenzylguanidine images obtained 15-20 min after tracer administration are as accurate for dementia with Lewy bodies (DLB) diagnosis as standard images acquired after a delay of 3-4 h; some suggest delayed imaging is preferable. We compare early and delayed heart-to-mediastinum ratios (HMR) in a well-characterised research dataset and make recommendations for clinical practice. METHODS: Images were acquired using a Siemens gamma camera with medium energy collimators. Early images were obtained at 20 min and delayed at 4 h (± 30) min. In total 167 pairs of images were reviewed: 30 controls, 39 people with dementia and 98 with mild cognitive impairment. HMR normal cutoff values derived from control data were ≥2.10 for early imaging and ≥1.85 for delayed. RESULTS: HMR tended to drop between early and delayed for abnormal images, but increase for normal images. Histograms of early and delayed HMR showed a slightly better separation of results into two groups for delayed imaging. Accuracy results were slightly higher for delayed imaging than early imaging (73 vs. 77%), sensitivity 63 vs. 65% and specificity 82 vs. 88%. However, this was not statistically significant - in total only 8/167 (5%) of scans changed designation between early and delayed imaging. CONCLUSION: We suggest that a delayed image could be acquired only if the early result is borderline. This removes the need for delayed imaging in about 70% of patients. Adopting this protocol in clinical practice would reduce the time most patients have to wait and could free up scanner time.
Assuntos
3-Iodobenzilguanidina , Doença por Corpos de Lewy , Diagnóstico Diferencial , Coração/diagnóstico por imagem , Humanos , Radioisótopos do Iodo , Doença por Corpos de Lewy/diagnóstico por imagem , Compostos RadiofarmacêuticosRESUMO
OBJECTIVES: Surgical resection of the maxilla impairs aesthetics, speech, swallowing, and mastication. Maxillary reconstruction is increasingly performed with virtual surgical planning (VSP) to enhance functional dental rehabilitation with a conventional denture or osseointegrated implants. The aim of this study was to determine whether dental status and VSP is associated with health-related quality of life (HRQOL) and function in patients who have undergone maxillectomy. MATERIALS AND METHODS: A cross-sectional study was conducted among patients who underwent free flap reconstruction or obturation of the maxilla between July 2009 and December 2020. The FACE-Q Head and Neck Cancer (FACE-Q) module, M.D. Anderson Dysphagia Inventory (MDADI), and Speech Handicap Index (SHI) were used to evaluate HRQOL. RESULTS: Forty-three patients (response rate 59%) completed questionnaires and 48% underwent dental rehabilitation. In Okay Class II and III defects, adjusting for the effect of radiotherapy and time from surgery, there was a positive association between denture status and FACE-Q smiling (p = 0.020), eating (p = 0.012), smiling (p = 0.015), and MDADI global (p = 0.015), emotional (p = 0.027), functional (p = 0.028), and composite (p = 0.029) scores. VSP was associated with FACE-Q swallowing (p = 0.005), drooling (p = 0.030), eating (p = 0.008), smiling (p = 0.021), MDADI global (p = 0.017), emotional (p = 0.041), functional (p = 0.040), composite (p = 0.038), and SHI total scores (p = 0.042). CONCLUSIONS: Dentoalveolar rehabilitation and VSP were associated with higher HRQOL scores relating to eating and drinking, smiling, and speaking.
Assuntos
Transtornos de Deglutição , Procedimentos de Cirurgia Plástica , Estudos Transversais , Deglutição , Humanos , Qualidade de VidaRESUMO
OBJECTIVE: The present study aimed to clarify the neuropsychological profile of the emergent diagnostic category of Mild Cognitive Impairment with Lewy bodies (MCI-LB) and determine whether domain-specific impairments such as in memory were related to deficits in domain-general cognitive processes (executive function or processing speed). METHOD: Patients (n = 83) and healthy age- and sex-matched controls (n = 34) underwent clinical and imaging assessments. Probable MCI-LB (n = 44) and MCI-Alzheimer's disease (AD) (n = 39) were diagnosed following National Institute on Aging-Alzheimer's Association (NIA-AA) and dementia with Lewy bodies (DLB) consortium criteria. Neuropsychological measures included cognitive and psychomotor speed, executive function, working memory, and verbal and visuospatial recall. RESULTS: MCI-LB scored significantly lower than MCI-AD on processing speed [Trail Making Test B: p = .03, g = .45; Digit Symbol Substitution Test (DSST): p = .04, g = .47; DSST Error Check: p < .001, g = .68] and executive function [Trail Making Test Ratio (A/B): p = .04, g = .52] tasks. MCI-AD performed worse than MCI-LB on memory tasks, specifically visuospatial (Modified Taylor Complex Figure: p = .01, g = .46) and verbal (Rey Auditory Verbal Learning Test: p = .04, g = .42) delayed recall measures. Stepwise discriminant analysis correctly classified the subtype in 65.1% of MCI patients (72.7% specificity, 56.4% sensitivity). Processing speed accounted for more group-associated variance in visuospatial and verbal memory in both MCI subtypes than executive function, while no significant relationships between measures were observed in controls (all ps > .05). CONCLUSIONS: MCI-LB was characterized by executive dysfunction and slowed processing speed but did not show the visuospatial dysfunction expected, while MCI-AD displayed an amnestic profile. However, there was considerable neuropsychological profile overlap and processing speed mediated performance in both MCI subtypes.
Assuntos
Doença de Alzheimer , Disfunção Cognitiva , Doença por Corpos de Lewy , Doença de Alzheimer/diagnóstico , Cognição , Humanos , Doença por Corpos de Lewy/complicações , Doença por Corpos de Lewy/diagnóstico por imagem , Memória de Curto Prazo , Testes NeuropsicológicosRESUMO
BACKGROUND: Although microvascular free flaps are often used to reconstruct maxillary defects, dentoalveolar rehabilitation is arguably less common despite its importance to midface function and aesthetics. The aim of this study is to review the contemporary management of maxillary defects in a single quaternary referral institution to identify factors that assist or impede dentoalveolar rehabilitation. METHODS: A retrospective review of maxillary reconstructions performed between February 2017 and December 2020 was performed. Patient characteristics, defect classification, operative techniques, complications and dentoalveolar outcomes were recorded. RESULTS: A total of 85 maxillary reconstructions were performed in 73 patients. Of the 64 patients where dental rehabilitation was required, 31 received a functional denture (48%) with 24 (38%) being implant-retained. Significant predictors of successful rehabilitation included the use of virtual surgical planning (VSP; 86% vs. 25%, p < 0.001), preoperative prosthodontic assessment (82% vs. 21%, p < 0.001), prefabrication (100% vs. 40%, p = 0.002) and use of the zygomatic implant perforator flap technique (100% vs. 39%, p = 0.001). Preoperative prosthodontic consultation was associated with 21-fold increase in the odds of rehabilitation (odds ratio 20.9, 95% confidence interval 6.54-66.66, p < 0.005). CONCLUSION: Preoperative prosthodontic evaluation, VSP and reconstructive techniques developed to facilitate implant placement are associated with increased dental rehabilitation rates. Despite using an institutional algorithm, functional dentures are frequently prevented by factors including soft tissue constraints, disease recurrence and patient motivation.
Assuntos
Retalhos de Tecido Biológico , Procedimentos de Cirurgia Plástica , Estética , Humanos , Maxila/cirurgia , Estudos RetrospectivosRESUMO
OBJECTIVE: To provide evidence that cardiac I-123-metaiodobenzylguanidine sympathetic innervation imaging (MIBG) scintigraphy differentiates probable mild cognitive impairment with Lewy bodies (MCI-LB) from mild cognitive impairment due to Alzheimer disease (MCI-AD), we scanned patients with MCI and obtained consensus clinical diagnoses of their MCI subtype. We also performed baseline FP-CIT scans to compare the accuracy of MIBG and FP-CIT. METHODS: We conducted a prospective cohort study into the accuracy of cardiac MIBG scintigraphy in the diagnosis of MCI-LB. Follow-up clinical assessment was used to diagnose MCI-AD (no core features of MCI-LB and normal FP-CIT), probable MCI-LB (2 or more core features, or 1 core feature with abnormal FP-CIT), or possible MCI-LB (1 core feature or abnormal FP-CIT). For the comparison between MIBG and FP-CIT, only core clinical features were used for diagnosis. RESULTS: We recruited 95 people with mild cognitive impairment. Cardiac MIBG was abnormal in 22/37 probable and 2/15 possible MCI-LB cases and normal in 38/43 MCI-AD cases. The sensitivity in probable MCI-LB was 59% (95% confidence interval [CI], 42%-75%), specificity 88% (75%-96%), and accuracy 75% (64%-84%). The positive likelihood ratio was 5.1 and negative likelihood ratio 0.46. With symptom-only diagnoses, the accuracies were 79% for MIBG (95% CI, 68%-87%) and 76% for FP-CIT (95% CI, 65%-85%). CONCLUSIONS: Cardiac MIBG appears useful in early disease, with an abnormal scan highly suggestive of MCI-LB. Validation in a multicenter setting is justified. CLASSIFICATION OF EVIDENCE: This study provides Class I evidence that cardiac MIBG distinguishes MCI-LB from MCI-AD.
Assuntos
Doença de Alzheimer/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Doença por Corpos de Lewy/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/normas , Tomografia Computadorizada de Emissão de Fóton Único/normas , 3-Iodobenzilguanidina , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/complicações , Doença de Alzheimer/fisiopatologia , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/fisiopatologia , Diagnóstico Diferencial , Feminino , Seguimentos , Coração/inervação , Humanos , Doença por Corpos de Lewy/complicações , Doença por Corpos de Lewy/fisiopatologia , Masculino , Sensibilidade e Especificidade , TropanosRESUMO
INTRODUCTION: Some studies report that assessing regional 123I-cardiac MIBG uptake can aid in the diagnosis of Lewy body disease, but others report heterogeneity in healthy controls. We aimed to evaluate regional cardiac MIBG uptake patterns in healthy older adults and patients with dementia. METHODS: 31 older adults with normal cognition, 15 Alzheimer's disease (AD), and 17 Dementia with Lewy bodies (DLB) patients were recruited. 5 individuals had previous myocardial infarction. Participants with sufficient cardiac uptake for regional SPECT analysis (29/31 controls, 15/15 AD, 5/17 DLB) had relative uptake pattern recorded. Controls were assessed for risk of future cardiovascular events using QRISK2, a validated online tool. RESULTS: In controls uptake was reduced in the inferior wall (85%), apex (23%), septum (15%), and lateral wall (8%). AD and DLB showed similar patterns to controls. Lung or liver interference was present in 61% of cases. Myocardial infarction cases showed regional reductions in uptake, but normal/borderline planar uptake. In controls, there was no relationship between cardiovascular risk score and uptake pattern. CONCLUSIONS: Significant variability of regional cardiac 123I-MIBG uptake is common in cases with normal planar cardiac uptake. Heterogeneity of regional uptake appears non-specific and unlikely to aid in the diagnosis of Lewy body disease.
Assuntos
Radioisótopos do Iodo/administração & dosagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/normas , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/diagnóstico por imagem , Feminino , Humanos , Radioisótopos do Iodo/uso terapêutico , Doença por Corpos de Lewy/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/uso terapêutico , Sensibilidade e Especificidade , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Reino UnidoRESUMO
INTRODUCTION: The quantitative assessment of facial appearance and function is critical in the process of restoring normality and thus minimising morbidity in patients with facial deformities. Three-dimensional (3D) scanners have increasingly been applied in clinical settings to circumvent the issues associated with standard approaches, namely, subjectivity. This study aimed to summarise the current literature on the accuracy, reliability, and usability of 3D scanning technologies for soft-tissue facial assessment. METHODOLOGY: Medline, EMBASE, and Web of Science were searched for studies assessing the accuracy, reliability, and/or clinical usability of 3D scanners in assessing facial morphology. All results were filtered by title, abstract, and finally by full text for relevance. RESULTS: Eight hundred and thirty-seven results were filtered down to 41 articles that were included in this review. Articles were categorised depending on the 3D visualising principle of the scanner being tested: laser-based scanning, stereophotogrammetry, structured-light scanning, or RGB-D (red, green, blue-depth) sensors. DISCUSSION: Of the traditional 3D scanners evaluated in the literature, stereophotogrammetric systems most consistently demonstrate excellent accuracy and reliability in the collection of 3D facial scans. Due to their cost, size, and complexity, these systems are often unsuitable for incorporation into clinical environments with limited availability of resources, space, and time. Recently developed RGB-D sensors can collect accurate static and dynamic 3D facial scans without many of these disadvantages. Still, further improvements in their technical specifications and a greater focus on the development of automated facial assessment software is needed before RGB-D sensors can be universally accepted as a new gold-standard for soft-tissue facial assessment.