Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Pract Lab Med ; 39: e00374, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38463198

RESUMO

Objective: To convert manual ELISA kits to fully automated immunoassays that quantify serum drug levels and anti-drug antibodies levels of infliximab and adalimumab (CHORUS Promonitor kits). Desing and methods: CHORUS Promonitor INFLIXIMAB, CHORUS Promonitor ADALIMUMAB, CHORUS Promonitor ANTI-INFLIXIMAB, and CHORUS Promonitor ANTI-ADALIMUMAB kits were compared with the corresponding Promonitor kits to determine sensitivity and specificity of the assays. For the automated assays, the entire procedure -from samples dilution to final readouts-was performed by CHORUS TRIO instrument (DIESSE, Italy). Residual human serum samples from clinical laboratory investigations and samples resulting from the addition of specific drugs (IFX or ADL) or anti-drug antibodies (anti-IFX or anti-ADL) were used for the characterization and validation of the tests. Results: CHORUS Promonitor kits showed an excellent agreement (Cohen's coefficient = 1) with the Promonitor kits and were linear within predefined ranges. All assays were accurate and repeatable, as an acceptable variability were observed within runs, between runs, lots, and instruments. No difference in detecting the reference drug or biosimilars emerged. Conclusion: During preclinical development, these kits resulted as sensitive, specific, accurate, and able to quantify either the reference drug or the corresponding biosimilars. All these features support their use in clinical practice for therapeutic drug monitoring of patients with inflammatory diseases under treatment with IFX or ADL.

2.
Nat Commun ; 15(1): 1151, 2024 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378671

RESUMO

Artificial communication with the brain through peripheral nerve stimulation shows promising results in individuals with sensorimotor deficits. However, these efforts lack an intuitive and natural sensory experience. In this study, we design and test a biomimetic neurostimulation framework inspired by nature, capable of "writing" physiologically plausible information back into the peripheral nervous system. Starting from an in-silico model of mechanoreceptors, we develop biomimetic stimulation policies. We then experimentally assess them alongside mechanical touch and common linear neuromodulations. Neural responses resulting from biomimetic neuromodulation are consistently transmitted towards dorsal root ganglion and spinal cord of cats, and their spatio-temporal neural dynamics resemble those naturally induced. We implement these paradigms within the bionic device and test it with patients (ClinicalTrials.gov identifier NCT03350061). He we report that biomimetic neurostimulation improves mobility (primary outcome) and reduces mental effort (secondary outcome) compared to traditional approaches. The outcomes of this neuroscience-driven technology, inspired by the human body, may serve as a model for advancing assistive neurotechnologies.


Assuntos
Biomimética , Tato , Masculino , Humanos , Tato/fisiologia , Gânglios Espinais , Encéfalo , Computadores
5.
Nat Mater ; 20(7): 925-939, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33859381

RESUMO

Commercial prosthetic devices currently do not provide natural sensory information on the interaction with objects or movements. The subsequent disadvantages include unphysiological walking with a prosthetic leg and difficulty in controlling the force exerted with a prosthetic hand, thus creating health issues. Restoring natural sensory feedback from the prosthesis to amputees is an unmet clinical need. An optimal device should be able to elicit natural sensations of touch or proprioception, by delivering the complex signals to the nervous system that would be produced by skin, muscles and joints receptors. This Review covers the various neurotechnological approaches that have been proposed for the development of the optimal sensory feedback restoration device for arm and leg amputees.


Assuntos
Amputados , Membros Artificiais , Retroalimentação Sensorial/fisiologia , Humanos , Desenho de Prótese
6.
Sci Adv ; 7(17)2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33883127

RESUMO

Above-knee amputees suffer the lack of sensory information, even while using most advanced prostheses. Restoring intraneural sensory feedback results in functional and cognitive benefits. It is unknown how this artificial feedback, restored through a neuro-robotic leg, influences users' sensorimotor strategies and its implications for future wearable robotics. To unveil these mechanisms, we measured gait markers of a sensorized neuroprosthesis in two leg amputees during motor tasks of different difficulty. Novel sensorimotor strategies were intuitively promoted, allowing for a higher walking speed in both tasks. We objectively quantified the augmented prosthesis' confidence and observed the reshaping of the legs' kinematics toward a more physiological gait. In a possible scenario of a leg amputee driving a conventional car, we showed a finer pressure estimation from the prosthesis. Users exploited different features of the neural stimulation during tasks, suggesting that a simple prosthesis sensorization could be effective for future neuro-robotic prostheses.

7.
Curr Biol ; 31(5): 1065-1071.e4, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33417885

RESUMO

One of the main reasons why amputees report poor satisfaction with prostheses is their excessive weight perceived,1 despite the fact that they typically weigh less than half of the natural limb.2 Weight perception can be a subjective percept that is influenced by cognitive processes.3-5 Even though recent developments in prosthetics have shown that sensory feedback restoration positively influences cognitive aspects (as embodiment of the device and cognitive load),6,7 the potential benefits on prosthesis heaviness perception have never been investigated. In this study, we explored this matter using intraneural sensory feedback in a transfemoral (above-knee) amputee. We hypothesized that providing neural feedback would affect the integration of the prosthesis in the amputee's body schema, hence influencing the prosthesis weight perception. The results indicate that, after performing an over-ground walking task, the sensory feedback allowed a 23% decrease in prosthesis heaviness perception compared to the no feedback condition. Our hypothesis was confirmed by a significant increase in the embodiment of the prosthesis (by 60.5%) and confidence (by 36%) while walking with the sensory feedback. A subsequent dual task (i.e., walking while spelling backward) showed that the sensory feedback abolished the reduction of walking speed and accuracy observed during the no-feedback condition and normally seen with increased mental workload, suggesting a cognitive integration of the system. These results show the importance of providing close-to-natural sensations from the missing limb to allow a good integration of the prostheses and increase the satisfaction of their users. VIDEO ABSTRACT.


Assuntos
Amputados , Membros Artificiais , Retroalimentação , Retroalimentação Sensorial , Humanos , Caminhada
8.
Front Med Technol ; 3: 619280, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35047903

RESUMO

Somatosensory neuroprostheses exploit invasive and non-invasive feedback technologies to restore sensorimotor functions lost to disease or trauma. These devices use electrical stimulation to communicate sensory information to the brain. A sensation characterization procedure is thus necessary to determine the appropriate stimulation parameters and to establish a clear personalized map of the sensations that can be restored. Several questionnaires have been described in the literature to collect the quality, type, location, and intensity of the evoked sensations, but there is still no standard psychometric platform. Here, we propose a new psychometric system containing previously validated questionnaires on evoked sensations, which can be applied to any kind of somatosensory neuroprosthesis. The platform collects stimulation parameters used to elicit sensations and records subjects' percepts in terms of sensation location, type, quality, perceptual threshold, and intensity. It further collects data using standardized assessment questionnaires and scales, performs measurements over time, and collects phantom limb pain syndrome data. The psychometric platform is user-friendly and provides clinicians with all the information needed to assess the sensory feedback. The psychometric platform was validated with three trans-radial amputees. The platform was used to assess intraneural sensory feedback provided through implanted peripheral nerve interfaces. The proposed platform could act as a new standardized assessment toolbox to homogenize the reporting of results obtained with different technologies in the field of somatosensory neuroprosthetics.

9.
J Neural Eng ; 17(6)2020 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-33108764

RESUMO

Objective. The implantation of intraneural electrodes in amputees has been observed to be effective in providing subjects with sensory feedback. However, this implantation is challenging and time consuming. Surgeons must be especially trained to execute the implantation. Therefore, we aimed at developing a novel peripheral intraneural electrode and insertion mechanism, which could drastically reduce the overall implantation time while achieving a high neural selectivity.Approach.A new insertion method based on hollow microneedles was developed to realize the prompt and effective simultaneous implantation of up to 14 active sites in a transversal manner. Each needle guided two Pt/Ir microwires through the nervous tissue. After the insertion, the microneedles were released, leaving behind the microwires. Each microwire had one active site, which was coated with poly-3,4-ethylenedioxythiophene (PEDOT) to enhance the electrochemical properties. The active sites were characterized by evaluating the impedance, charge storage capacity, and maximum injectable charge. Twelve quick to implant peripheral intraneural electrodes (Q-PINEs) were implanted in four pig sciatic nerves to evaluate the implantation time and neural selectivity. We compared the stimulation of the sciatic nerve with that of its branches.Main results. The average surgical access time was 23 min. The insertion time for 12 electrodes was 6.7 min (std. ±1.6 min). The overall implantation time was reduced by 40.3 min compared to the previously reported values. The Q-PINE system demonstrated a satisfactory performance duringin vitroandin vivocharacterization. The electrochemical results showed that the PEDOT coating successfully increased the electrochemical parameters of the active sites.Significance.With an average impedance of 1.7 kΩ, a maximum charge level of 76.2 nC could be achieved per active site. EMG recruitment curves showed that 46% of the active sites exhibited selective stimulation of four out of six muscles. The histological analysis indicated that the microwires successfully penetrated the nerve and single fascicles.


Assuntos
Amputados , Polímeros , Animais , Impedância Elétrica , Estimulação Elétrica , Eletrodos Implantados , Humanos , Nervo Isquiático , Suínos
10.
Brain Behav ; 10(11): e01734, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32949216

RESUMO

OBJECTIVE: We investigated for the first time the presence of chronic changes in the functional organization of sensorimotor brain areas induced by prolonged training with a bidirectional hand prosthesis. METHODS: A multimodal neurophysiological and neuroimaging evaluation of brain functional changes occurring during training in five consecutive amputees participating to experimental trials with robotic hands over a period of 10 years was carried out. In particular, modifications to the functional anatomy of sensorimotor brain areas under resting conditions were explored in order to check for eventual changes with respect to baseline. RESULTS: Full evidence is provided to demonstrate brain functional changes, and some of them in both the hemispheres and others restricted to the hemisphere contralateral to the amputation/prosthetic hand. CONCLUSIONS: The study describes a unique experimental experience showing that brain reactions to the prolonged use of an artificial hand can be tracked for a tailored approach to a fully embedded artificial upper limb for future chronic uses in daily activities.


Assuntos
Amputados , Membros Artificiais , Amputação Cirúrgica , Mãos , Humanos , Extremidade Superior
11.
J Neuroeng Rehabil ; 17(1): 110, 2020 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-32799900

RESUMO

BACKGROUND: Recent studies have shown that neural stimulation can be used to provide artificial sensory feedback to amputees eliciting sensations referred on the amputated hand. The temporal properties of the neural stimulation modulate aspects of evoked sensations that can be exploited in a bidirectional hand prosthesis. METHODS: We previously collected evidence that the derivative of the amplitude of the stimulation (intra-digit temporal dynamics) allows subjects to recognize object compliance and that the time delay among stimuli injected through electrodes implanted in different nerves (inter-digit temporal distance) allows to recognize object shapes. Nevertheless, a detailed characterization of the subjects' sensitivity to variations of intra-digit temporal dynamic and inter-digit temporal distance of the intraneural tactile feedback has not been executed. An exhaustive understanding of the overall potentials and limits of intraneural stimulation to deliver sensory feedback is of paramount importance to bring this approach closer and closer to the natural situation. To this aim, here we asked two trans-radial amputees to identify stimuli with different temporal characteristics delivered to the same active site (intra-digit temporal Dynamic Recognition (DR)) or between two active sites (inter-digit Temporal distance Recognition (TR)). Finally, we compared the results achieved for (simulated) TR with conceptually similar experiments with real objects with one subject. RESULTS: We found that the subjects were able to identify stimuli with temporal differences (perceptual thresholds) larger than 0.25 s for DR and larger than 0.125 s for TR, respectively. Moreover, we also found no statistically significant differences when the subjects were asked to identify three objects during simulated 'open-loop' TR experiments or real 'closed-loop' tests while controlling robotic hand. CONCLUSIONS: This study is a new step towards a more detailed analysis of the overall potentials and limits of intraneural sensory feedback. A full characterization is necessary to develop more advanced prostheses capable of restoring all lost functions and of being perceived more as a natural limb by users.


Assuntos
Amputados/reabilitação , Membros Artificiais , Terapia por Estimulação Elétrica/métodos , Retroalimentação Sensorial/fisiologia , Tato/fisiologia , Adulto , Feminino , Mãos/fisiologia , Humanos , Pessoa de Meia-Idade , Robótica
12.
J Neural Eng ; 17(4): 046006, 2020 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-32512544

RESUMO

OBJECTIVE: Micro-fabricated neural interfaces based on polyimide (PI) are achieving increasing importance in translational research. The ability to produce well-defined micro-structures with properties that include chemical inertness, mechanical flexibility and low water uptake are key advantages for these devices. APPROACH: This paper reports the development of the transverse intrafascicular multichannel electrode (TIME) used to deliver intraneural sensory feedback to an upper-limb amputee in combination with a sensorized hand prosthesis. A failure mode analysis on the explanted devices was performed after a first-in-human study limited to 30 d. MAIN RESULTS: About 90% of the stimulation contact sites of the TIMEs maintained electrical functionality and stability during the full implant period. However, optical analysis post-explantation revealed that 62.5% of the stimulation contacts showed signs of delamination at the metallization-PI interface. Such damage likely occurred due to handling during explantation and subsequent analysis, since a significant change in impedance was not observed in vivo. Nevertheless, whereas device integrity is mandatory for long-term functionality in chronic implantation, measures to increase the bonding strength of the metallization-PI interface deserve further investigation. We report here that silicon carbide (SiC) is an effective adhesion-promoting layer resisting heavy electrical stimulation conditions within a rodent animal trial. Optical analysis of the new electrodes revealed that the metallization remained unaltered after delivering over 14 million pulses in vivo without signs of delamination at the metallization-PI interface. SIGNIFICANCE: Failure mode analysis guided implant stability optimization. Reliable adhesion of thin-film metallization to substrate has been proven using SiC, improving the potential transfer of micro-fabricated neural electrodes for chronic clinical applications. (Document number of Ethical Committee: P/905/CE/2012; Date of approval: 2012-10-04).


Assuntos
Amputados , Próteses e Implantes , Animais , Impedância Elétrica , Estimulação Elétrica , Eletrodos , Eletrodos Implantados , Humanos , Microeletrodos
13.
Artigo em Inglês | MEDLINE | ID: mdl-32318562

RESUMO

Recent experiments have shown that neural stimulation can successfully restore sensory feedback in upper-limb amputees improving their ability to control the prosthesis. However, the potential advantages of invasive sensory feedback with respect to non-invasive solutions have not been yet identified. Our hypothesis was that a difference would appear when the subject cannot focus all the attention to the use of the prosthesis, but some additional activities require his/her cognitive attention, which is a quite common situation in real-life conditions. To verify this hypothesis, we asked a trans-radial amputee, equipped with a bidirectional hand prosthesis, to perform motor tasks also in combination with a cognitive task. Sensory feedback was provided via intraneural (invasive) or electro-tactile (non-invasive) stimulation. We collected also data related to self-confidence. While both approaches were able to significantly improve the motor performance of the subject when no additional cognitive effort was asked, the manual accuracy was not affected by the cognitive task only when intraneural feedback was provided. The highest self-confidence was obtained when intraneural sensory feedback was provided. Our findings show that intraneural sensory feedback is more robust to dual tasks than non-invasive feedback. This is the first direct comparison between invasive and non-invasive approaches for restoring sensory feedback and it could suggest an advantage of using invasive solutions. Clinical Trial Registration: www.ClinicalTrials.gov, identifier NCT02848846.

14.
J Neural Eng ; 17(2): 026034, 2020 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-32207409

RESUMO

OBJECTIVE: A major challenge in neuroprosthetics is the restoration of sensory-motor hand functions in upper-limb amputees. Neuroprostheses based on the direct re-connection of the peripheral nerves may be an interesting approach for re-establishing the natural and effective bidirectional control of hand prostheses. Recent results have shown that transverse intrafascicular multi-channel electrodes (TIMEs) can restore natural and sophisticated sensory feedback. However, the potential of using TIME-recorded motor intraneural signals to decode grasping tasks has not as yet been explored. APPROACH: In this study, we show that several hand-movement intentions can be decoded from intraneural signals recorded using four TIMEs implanted in the median and ulnar nerves of an upper limb amputee. Experimental sessions were performed over a week, from day 16 to day 23 after the surgical operation. Intraneural activity was recorded during several hand motor tasks imagined by the subject and processed offline. MAIN RESULTS: We obtained a very high decoding accuracy considering 11 class states (up to 83%). These results confirm that neural signals recorded by multi-channel intraneural electrodes can be used to decode several movement intentions with high accuracy. Moreover, we were able to use same TIME channels for decoding over one week within the first month, even if the stability has to be confirmed during long-term experiments. SIGNIFICANCE: Therefore, TIMEs could be used in the future to achieve a complete bidirectional approach exploiting neural pathways, to make a more natural and intuitive new generation of hand prostheses that have a closer resemblance to a healthy hand.


Assuntos
Amputados , Membros Artificiais , Retroalimentação Sensorial , Mãos , Força da Mão , Humanos
15.
Sci Rep ; 10(1): 527, 2020 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-31949245

RESUMO

Humans rely on their sense of touch to interact with the environment. Thus, restoring lost tactile sensory capabilities in amputees would advance their quality of life. In particular, texture discrimination is an important component for the interaction with the environment, but its restoration in amputees has been so far limited to simplified gratings. Here we show that naturalistic textures can be discriminated by trans-radial amputees using intraneural peripheral stimulation and tactile sensors located close to the outer layer of the artificial skin. These sensors exploit the morphological neural computation (MNC) approach, i.e., the embodiment of neural computational functions into the physical structure of the device, encoding normal and shear stress to guarantee a faithful neural temporal representation of stimulus spatial structure. Two trans-radial amputees successfully discriminated naturalistic textures via the MNC-based tactile feedback. The results also allowed to shed light on the relevance of spike temporal encoding in the mechanisms used to discriminate naturalistic textures. Our findings pave the way to the development of more natural bionic limbs.

16.
Sci Transl Med ; 11(512)2019 10 02.
Artigo em Inglês | MEDLINE | ID: mdl-31578244

RESUMO

Lower limb amputation (LLA) destroys the sensory communication between the brain and the external world during standing and walking. Current prostheses do not restore sensory feedback to amputees, who, relying on very limited haptic information from the stump-socket interaction, are forced to deal with serious issues: the risk of falls, decreased mobility, prosthesis being perceived as an external object (low embodiment), and increased cognitive burden. Poor mobility is one of the causes of eventual device abandonment. Restoring sensory feedback from the missing leg of above-knee (transfemoral) amputees and integrating the sensory feedback into the sensorimotor loop would markedly improve the life of patients. In this study, we developed a leg neuroprosthesis, which provided real-time tactile and emulated proprioceptive feedback to three transfemoral amputees through nerve stimulation. The feedback was exploited in active tasks, which proved that our approach promoted improved mobility, fall prevention, and agility. We also showed increased embodiment of the lower limb prosthesis (LLP), through phantom leg displacement perception and questionnaires, and ease of the cognitive effort during a dual-task paradigm, through electroencephalographic recordings. Our results demonstrate that induced sensory feedback can be integrated at supraspinal levels to restore functional abilities of the missing leg. This work paves the way for further investigations about how the brain interprets different artificial feedback strategies and for the development of fully implantable sensory-enhanced leg neuroprostheses, which could drastically ameliorate life quality in people with disability.


Assuntos
Membros Artificiais , Cognição/fisiologia , Extremidade Inferior/cirurgia , Atividades Cotidianas , Amputados , Humanos , Articulação do Joelho/fisiopatologia , Articulação do Joelho/cirurgia , Extremidade Inferior/fisiopatologia , Desenho de Prótese
17.
Nat Med ; 25(9): 1356-1363, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31501600

RESUMO

Conventional leg prostheses do not convey sensory information about motion or interaction with the ground to above-knee amputees, thereby reducing confidence and walking speed in the users that is associated with high mental and physical fatigue1-4. The lack of physiological feedback from the remaining extremity to the brain also contributes to the generation of phantom limb pain from the missing leg5,6. To determine whether neural sensory feedback restoration addresses these issues, we conducted a study with two transfemoral amputees, implanted with four intraneural stimulation electrodes7 in the remaining tibial nerve (ClinicalTrials.gov identifier NCT03350061). Participants were evaluated while using a neuroprosthetic device consisting of a prosthetic leg equipped with foot and knee sensors. These sensors drive neural stimulation, which elicits sensations of knee motion and the sole of the foot touching the ground. We found that walking speed and self-reported confidence increased while mental and physical fatigue decreased for both participants during neural sensory feedback compared to the no stimulation trials. Furthermore, participants exhibited reduced phantom limb pain with neural sensory feedback. The results from these proof-of-concept cases provide the rationale for larger population studies investigating the clinical utility of neuroprostheses that restore sensory feedback.


Assuntos
Amputados/reabilitação , Membros Artificiais , Joelho/fisiopatologia , Membro Fantasma/prevenção & controle , Adulto , Fenômenos Biomecânicos , Retroalimentação Sensorial , Humanos , Joelho/inervação , Masculino , Pessoa de Meia-Idade , Membro Fantasma/fisiopatologia , Velocidade de Caminhada/fisiologia
18.
Biomed Eng Online ; 18(1): 44, 2019 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-30961620

RESUMO

BACKGROUND: The usability of dexterous hand prostheses is still hampered by the lack of natural and effective control strategies. A decoding strategy based on the processing of descending efferent neural signals recorded using peripheral neural interfaces could be a solution to such limitation. Unfortunately, this choice is still restrained by the reduced knowledge of the dynamics of human efferent signals recorded from the nerves and associated to hand movements. FINDINGS: To address this issue, in this work we acquired neural efferent activities from healthy subjects performing hand-related tasks using ultrasound-guided microneurography, a minimally invasive technique, which employs needles, inserted percutaneously, to record from nerve fibers. These signals allowed us to identify neural features correlated with force and velocity of finger movements that were used to decode motor intentions. We developed computational models, which confirmed the potential translatability of these results showing how these neural features hold in absence of feedback and when implantable intrafascicular recording, rather than microneurography, is performed. CONCLUSIONS: Our results are a proof of principle that microneurography could be used as a useful tool to assist the development of more effective hand prostheses.


Assuntos
Algoritmos , Mãos/diagnóstico por imagem , Mãos/inervação , Nervo Mediano/fisiologia , Desenho de Prótese/métodos , Feminino , Dedos/diagnóstico por imagem , Dedos/fisiologia , Mãos/fisiologia , Humanos , Masculino , Neurônios Motores/citologia , Movimento , Músculos/fisiologia , Ultrassonografia
19.
J Neural Eng ; 16(2): 026034, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30736030

RESUMO

OBJECTIVE: Tactile afferents in the human hand provide fundamental information about hand-environment interactions, which is used by the brain to adapt the motor output to the physical properties of the object being manipulated. A hand amputation disrupts both afferent and efferent pathways from/to the hand, completely invalidating the individual's motor repertoire. Although motor functions may be partially recovered by using a myoelectric prosthesis, providing functionally effective sensory feedback to users of prosthetics is a largely unsolved challenge. While past studies using invasive stimulation suggested that sensory feedback may help in handling fragile objects, none explored the underpinning, relearned, motor coordination during grasping. In this study, we aimed at showing for the first time that intraneural sensory feedback of the grip force (GF) improves the sensorimotor control of a transradial amputee controlling a myoelectric prosthesis. APPROACH: We performed a longitudinal study testing a single subject (clinical trial registration number NCT02848846). A stacking cups test (CUP) performed over two weeks aimed at measuring the subject's ability to finely regulate the GF applied with the prosthesis. A pick and lift test (PLT), performed at the end of the study, measured the level of motor coordination, and whether the subject transferred the motor skills learned in the CUP to an alien task. MAIN RESULTS: The results show that intraneural sensory feedback increases the subject's ability in regulating the GF and allows for improved performance over time. Additionally, the PLT demonstrated that the subject was able to generalize and transfer her manipulation skills to an unknown task and to improve her motor coordination. SIGNIFICANCE: Our findings suggest that intraneural sensory feedback holds the potential of restoring functionally effective tactile feedback. This opens up new possibilities to improve the quality of life of amputees using a neural prosthesis.


Assuntos
Amputados/reabilitação , Membros Artificiais , Retroalimentação Sensorial/fisiologia , Força da Mão/fisiologia , Desenho de Prótese/métodos , Desempenho Psicomotor/fisiologia , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Eletrodos Implantados , Feminino , Mãos , Humanos , Estudos Longitudinais , Pessoa de Meia-Idade , Desenho de Prótese/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA