Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Heart Fail ; 26(6): 1383-1392, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38741283

RESUMO

AIMS: We examined the effectiveness of a novel cardiopulmonary management wearable sensor (worn for less than 5 mins) at measuring congestion and correlated the device findings with established clinical measures of congestion. METHODS AND RESULTS: We enrolled three cohorts of patients: (1) patients with heart failure (HF) receiving intravenous diuretics in hospital; (2) patients established on haemodialysis, and (3) HF patients undergoing right heart catheterization (RHC). The primary outcomes in the respective cohorts were a Spearman correlation between (1) change in weight and change in thoracic impedance (TI) (from enrolment, 24 h after admission to discharge) in patients hospitalized for HF; (2) lung ultrasound B-lines and volume removed during dialysis with device measured TI, and (3) pulmonary capillary wedge pressure (PCWP) and sub-acoustic diastolic, third heart sound (S3) in the patients undergoing RHC. A total of 66 patients were enrolled. In HF patients (n = 25), change in weight was correlated with both change in device TI (Spearman correlation [rsp] = -0.64, p = 0.002) and change in device S3 (rsp = -0.53, p = 0.014). In the haemodialysis cohort (n = 21), B-lines and TI were strongly correlated before (rsp = -0.71, p < 0.001) and after (rsp = -0.77, p < 0.001) dialysis. Volume of fluid removed by dialysis was correlated with change in device TI (rsp = 0.49, p = 0.024). In the RHC cohort (n = 20), PCWP measured at one time point and device S3 were not significantly correlated (rsp = 0.230, p = 0.204). There were no device-related adverse events. CONCLUSIONS: A non-invasive device was able to detect changes in congestion in patients with HF receiving decongestion therapy and patients having fluid removed at haemodialysis. The cardiopulmonary management device, which measures multiple parameters, is a potentially useful tool to monitor patients with HF to prevent hospitalizations.


Assuntos
Insuficiência Cardíaca , Diálise Renal , Humanos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/fisiopatologia , Masculino , Feminino , Diálise Renal/instrumentação , Diálise Renal/métodos , Idoso , Pessoa de Meia-Idade , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação , Dispositivos Eletrônicos Vestíveis , Pressão Propulsora Pulmonar/fisiologia , Cateterismo Cardíaco/métodos
2.
Intensive Care Med ; 50(4): 493-501, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38526578

RESUMO

An implantable left ventricular assist device (LVAD) is indicated as a bridge to transplantation or recovery in the United Kingdom (UK). The mechanism of action of the LVAD results in a unique state of haemodynamic stability with diminished arterial pulsatility. The clinical assessment of an LVAD recipient can be challenging because non-invasive blood pressure, pulse and oxygen saturation measurements may be hard to obtain. As a result of this unusual situation and complex interplay between the device and the native circulation, resuscitation of LVAD recipients requires bespoke guidelines. Through collaboration with key UK stakeholders, we assessed the current evidence base and developed guidelines for the recognition of clinical deterioration, inadequate circulation and time-critical interventions. Such guidelines, intended for use in transplant centres, are designed to be deployed by those providing immediate care of LVAD patients under conditions of precipitous clinical deterioration. In summary, the Joint British Societies and Transplant Centres LVAD Working Group present the UK guideline on management of emergencies in implantable LVAD recipients for use in advanced heart failure centres. These recommendations have been made with a UK resuscitation focus but are widely applicable to professionals regularly managing patients with implantable LVADs.


Assuntos
Deterioração Clínica , Insuficiência Cardíaca , Transplante de Coração , Coração Auxiliar , Humanos , Emergências , Insuficiência Cardíaca/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA