Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
AJNR Am J Neuroradiol ; 31(8): 1521-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20488901

RESUMO

BACKGROUND AND PURPOSE: Coil embolization procedures change the flow conditions in the cerebral aneurysm and, therefore, in the near-wall region. Knowledge of these flow changes may be helpful to optimize therapy. The goal of this study was to investigate the effect of the coil-packing attenuation on the near-wall flow and its variability due to differences in the coil structure. MATERIALS AND METHODS: An enlarged transparent model of an ACA aneurysm was fabricated on the basis of CT angiography. The near-wall flow was visualized by using a recently proposed technique called Wall-PIV. Coil-packing attenuation of 10%, 15%, and 20% were investigated and compared with an aneurysmal flow without coils. Then the flow variability due to the coil introduction was analyzed in 10 experiments by using a packing attenuation of 15%. RESULTS: A small packing attenuation of 10% already alters the near-wall flow significantly in a large part of the aneurysmal sac. These flow changes are characterized by a slow flow with short (interrupted) path lines. An increased packing attenuation expands the wall area exposed to the altered flow conditions. This area, however, depends on the coil position and/or on the 3D coil structure in the aneurysm. CONCLUSIONS: To our knowledge, this is the first time the near-wall flow changes caused by coils in an aneurysm model have been visualized. It can be concluded that future hydrodynamic studies of coil therapy should include an investigation of the coil structure in addition to the coil-packing attenuation.


Assuntos
Angiografia Cerebral , Embolização Terapêutica , Aneurisma Intracraniano , Modelos Cardiovasculares , Circulação Cerebrovascular/fisiologia , Simulação por Computador , Feminino , Humanos , Técnicas In Vitro , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/fisiopatologia , Aneurisma Intracraniano/terapia , Pessoa de Meia-Idade , Modelos Anatômicos , Nylons , Fluxo Sanguíneo Regional/fisiologia
2.
Ann Oncol ; 15(4): 661-4, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15033676

RESUMO

BACKGROUND: From 2% to 10% of cancer patients treated with 5-fluorouracil (5-FU) will develop symptomatic cardiotoxicity. Nevertheless, the underlying pathophysiology is mostly unknown. PATIENTS AND METHODS: We investigated the influence of intravenous chemotherapy (CTX) on the diameter of the brachial artery using high resolution ultrasound in patients with malignant tumors, mostly gastrointestinal cancer. Cytostatic drugs included 30 cases with 5-FU and 30 cases with non-5-FU CTX (cis/carboplatin, anthracycline and cyclophosphamide). In addition, plasma levels of big endothelin were assessed prior to and after CTX. RESULTS: Fifteen of 30 patients (50%) showed a contraction of the brachial artery after the end of 5-FU application (median 11%, range 4.3-18.5), whereas no single contraction was noticed in 30 patients following non-5-FU-based CTX. Vessel tonus generally normalized within 30 min after stopping 5-FU. Five patients positive for 5-FU associated vessel contraction were repeatedly exposed to 5-FU. Vessel contractions reoccurred in 86% (18/21) of these administrations. When patients with 5-FU bolus application were pre-treated with glyceroltrinitrate no contraction of the brachial artery was detected in five out of five occasions. There was a trend towards increased big endothelin plasma levels after 5-FU application (median 1.52 versus 1.99 fmol/ml; P = 0.07), whereas big endothelin levels remained unchanged after non-5-FU CTX (1.83 versus 1.83 fmol/ml; P = 0.99). CONCLUSIONS: Application of 5-FU is commonly accompanied by arterial vessel contractions, which is likely to represent the first step in 5-FU-induced cardiotoxicity. 5-FU-associated vessel contractions were highly reproducible on re-exposure and were in the case of bolus application completely preventable by glyceroltrinitrate.


Assuntos
Artéria Braquial/efeitos dos fármacos , Fluoruracila/efeitos adversos , Neoplasias/tratamento farmacológico , Vasoconstrição/efeitos dos fármacos , Adulto , Idoso , Idoso de 80 Anos ou mais , Antimetabólitos Antineoplásicos/efeitos adversos , Antimetabólitos Antineoplásicos/uso terapêutico , Artéria Braquial/fisiopatologia , Endotelinas/sangue , Fluoruracila/uso terapêutico , Neoplasias Gastrointestinais/tratamento farmacológico , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA