Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Ear Hear ; 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-39054580

RESUMO

OBJECTIVES: The inter-phase gap (IPG) offset effect is defined as the dB offset between the linear parts of electrically evoked compound action potential (ECAP) amplitude growth functions for two stimuli differing only in IPG. The method was recently suggested to represent neural health in cochlear implant (CI) users while being unaffected by CI electrode impedances. Hereby, a larger IPG offset effect should reflect better neural health. The aims of the present study were to (1) examine whether the IPG offset effect negatively correlates with the ECAP threshold and the preoperative pure-tone average (PTA) in CI recipients with residual acoustic hearing and (2) investigate the dependency of the IPG offset effect on hair cell survival and intracochlear electrode impedances. DESIGN: Seventeen adult study participants with residual acoustic hearing at 500 Hz undergoing CI surgery at the University Hospital of Zurich were prospectively enrolled. ECAP thresholds, IPG offset effects, electrocochleography (ECochG) responses to 500 Hz tone bursts, and monopolar electrical impedances were obtained at an apical, middle, and basal electrode set during and between 4 and 12 weeks after CI surgery. Pure-tone audiometry was conducted within 3 weeks before surgery and approximately 6 weeks after surgery. Linear mixed regression analyses and t tests were performed to assess relationships between (changes in) ECAP threshold, IPG offset, impedance, PTA, and ECochG amplitude. RESULTS: The IPG offset effect positively correlated with the ECAP threshold in intraoperative recordings (p < 0.001) and did not significantly correlate with the preoperative PTA (p = 0.999). The IPG offset showed a postoperative decrease for electrode sets that showed an ECochG amplitude drop. This IPG offset decrease was significantly larger than for electrode sets that showed no ECochG amplitude decrease, t(17) = 2.76, p = 0.014. Linear mixed regression analysis showed no systematic effect of electrode impedance changes on the IPG offset effect (p = 0.263) but suggested a participant-dependent effect of electrode impedance on IPG offset. CONCLUSIONS: The present study results did not reveal the expected relationships between the IPG offset effect and ECAP threshold values or between the IPG offset effect and preoperative acoustic hearing. Changes in electrode impedance did not exhibit a direct impact on the IPG offset effect, although this impact might be individualized among CI recipients. Overall, our findings suggest that the interpretation and application of the IPG offset effect in clinical settings should be approached with caution considering its complex relationships with other cochlear and neural health metrics.

2.
J Clin Med ; 13(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38929998

RESUMO

Background: Various representations exist in the literature to visualize electrocochleography (ECochG) recordings along the basilar membrane (BM). This lack of generalization complicates comparisons within and between cochlear implant (CI) users, as well as between publications. This study synthesized the visual representations available in the literature via a systematic review and provides a novel approach to visualize ECochG data in CI users. Methods: A systematic review was conducted within PubMed and EMBASE to evaluate studies investigating ECochG and CI. Figures that visualized ECochG responses were selected and analyzed. A novel visualization of individual ECochG data, the ZH-ECochG Bode plot (ZH = Zurich), was devised, and the recordings from three CI recipients were used to demonstrate and assess the new framework. Results: Within the database search, 74 articles with a total of 115 figures met the inclusion criteria. Analysis revealed various types of representations using different axes; their advantages were incorporated into the novel visualization framework. The ZH-ECochG Bode plot visualizes the amplitude and phase of the ECochG recordings along the different tonotopic regions and angular insertion depths of the recording sites. The graph includes the pre- and postoperative audiograms to enable a comparison of ECochG responses with the audiometric profile, and allows different measurements to be shown in the same graph. Conclusions: The ZH-ECochG Bode plot provides a generalized visual representation of ECochG data, using well-defined axes. This will facilitate the investigation of the complex ECochG potentials generated along the BM and allows for better comparisons of ECochG recordings within and among CI users and publications. The scripts used to construct the ZH-ECochG Bode plot are provided by the authors.

3.
Audiol Neurootol ; 29(4): 322-333, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38342086

RESUMO

INTRODUCTION: The mechanism of non-osseous bone conduction pathways, involving the intracranial contents (ICC) of the skull, is still not well understood. This study aimed to investigate the influence of the ICC on the skull bone wave propagation, including dependence on stimulation location and coupling. METHODS: Three Thiel-embalmed whole-head cadaver specimens were studied before and after the removal of the ICC. Stimulation was via the electromagnetic actuators from commercial bone conduction hearing aids. Osseous pathways were sequentially activated by mastoid, forehead, and bone-anchored hearing aid location stimulation via a 5-Newton steel headband or percutaneously implanted screw. Non-osseous pathways were activated by stimulation on the eye and dura via a 5-Newton steel headband and a custom-made pneumatic holder, respectively. Under each test condition, the 3D motion of the superior skull bone was monitored at ∼200 points. RESULTS: The averaged response of the skull surface showed limited differences due to the removal of the ICC. In some isolated cases, the modal pattern on the skull surface showed a trend for an upshift (∼1/2 octave) in the observed natural frequencies for drained heads. This was also consistent with an observed trend for an upshift in the transition frequency in the estimated deformation across the lateral surfaces of the temporal bones. Such changes were consistent with the expected reduction in mass and damping due to the absence of the ICC. CONCLUSION: Overall, the ICC affect to a limited extent the motion of the skull bone, with a limited trend for a reduction of its natural frequencies.


Assuntos
Condução Óssea , Cadáver , Auxiliares de Audição , Crânio , Humanos , Condução Óssea/fisiologia , Crânio/fisiologia , Movimentos da Cabeça/fisiologia
4.
Trends Hear ; 27: 23312165231220997, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38105510

RESUMO

The objective to preserve residual hearing during cochlear implantation has recently led to the use of intracochlear electrocochleography (ECochG) as an intraoperative monitoring tool. Currently, a decrease in the amplitude of the difference between responses to alternating-polarity stimuli (DIF response), predominantly reflecting the hair cell response, is used for providing feedback. Including other ECochG response components, such as phase changes and harmonic distortions, could improve the accuracy of surgical feedback. The objectives of the present study were (1) to compare simultaneously recorded stepwise intracochlear and extracochlear ECochG responses to 500 Hz tone bursts, (2) to explore patterns in features extracted from the intracochlear ECochG recordings relating to hearing preservation or hearing loss, and (3) to design support vector machine (SVM) and random forest (RF) classifiers of acoustic hearing preservation that treat each subject as a sample and use all intracochlear ECochG recordings made during electrode array insertion for classification. Forty subjects undergoing cochlear implant (CI) surgery at the Oslo University Hospital, St. Thomas' Hearing Implant Centre, or the University Hospital of Zurich were prospectively enrolled. In this cohort, DIF response amplitude decreases did not relate to postoperative acoustic hearing preservation. Exploratory analysis of the feature set extracted from the ECochG responses and preoperative audiogram showed that the features were not discriminative between outcome classes. The SVM and RF classifiers that were trained on these features could not distinguish cases with hearing loss and hearing preservation. These findings suggest that hearing loss following CI surgery is not always reflected in intraoperative ECochG recordings.


Assuntos
Implante Coclear , Implantes Cocleares , Surdez , Perda Auditiva , Humanos , Cóclea/cirurgia , Audiometria de Resposta Evocada , Audição , Perda Auditiva/diagnóstico , Perda Auditiva/cirurgia , Surdez/reabilitação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA