Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Perinatol ; 32(4): 276-80, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21738120

RESUMO

OBJECTIVE: To compare the accuracy of pulse oximetry oxygen saturation (SpO(2)) measured on the wrist compared with the ipsilateral palm, and SpO(2) measured on the ankle compared with the ipsilateral sole. STUDY DESIGN: In this prospective observational study, neonates admitted to the neonatal intensive care unit were enrolled. We recorded SpO(2) (Masimo Radical-7 pulse oximeter) detected at the palm and ipsilateral wrist initially, then at 30 s, and at 1 min, and we repeated the same procedure over the sole and ipsilateral ankle. We recorded the time to obtain the SpO(2) readings from all these sites. Regression analysis was performed to determine the relationship between paired SpO(2) measurements. The mean difference (bias) and standard deviation of the paired SpO(2) differences (precision) were calculated (Bland-Altman plots). RESULT: A total of 150 patients (birth weight 2381±1020 g, gestational age 34.3±4.3 weeks, median postnatal age 3.5 days (25th-75th percentile 1-16 days)) were enrolled. There was a good correlation between SpO(2) measured at the palm versus the wrist (r=0.95, P<0.001 (right); r=0.97, P< 0.001 (left)) and between SpO(2) measured at the sole versus the ankle (r=0.92, P<0.001 (right); r=0.91, P<0.001 (left)). There was also a good agreement between paired SpO(2) measurements from these sites. The bias and precision for SpO(2) at the right palm and right wrist was 0.08±0.94% and for the left palm and left wrist 0.22±0.87%. Similarly, the bias and precision for SpO(2) at the right sole and right ankle was -0.03±0.93% and for the left sole and left ankle was -0.01±0.93%. CONCLUSION: Our results show that the wrist and ankle can be used as alternative sites to measure SpO(2) in newborn infants in place of the routinely used palm or sole.


Assuntos
Tornozelo/irrigação sanguínea , Oximetria/métodos , Oximetria/normas , Punho/irrigação sanguínea , Peso ao Nascer , Desenho de Equipamento , Feminino , Idade Gestacional , Frequência Cardíaca/fisiologia , Humanos , Recém-Nascido , Masculino , Oximetria/instrumentação , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
2.
Genet Couns ; 18(4): 417-21, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-18286823

RESUMO

We report a male neonate with a 45 X karyotype; the long arm of a chromosome 15 was translocated onto the proximal long arm of the Y chromosome. Breakpoints were identified by in situ fluorescence hybridization (FISH) on the proximal 15q13 and Yq11.2. The derivative chromosome has no primary centromere. Clinical features were compatible with Prader-Willi syndrome. This is the first report case ofmonosomy 15q and Yq deletion with Prader-Willi syndrome.


Assuntos
Cromossomos Humanos Par 15/genética , Cromossomos Humanos X/genética , Cromossomos Humanos Y/genética , Síndrome de Prader-Willi/genética , Translocação Genética , Criptorquidismo , Deleção de Genes , Humanos , Recém-Nascido , Doenças do Recém-Nascido , Recém-Nascido Prematuro , Cariotipagem , Masculino , Fenótipo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA