Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Med Imaging (Bellingham) ; 11(3): 033502, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38827778

RESUMO

Purpose: The modulation transfer function (MTF) and detective quantum efficiency (DQE) of x-ray detectors are key Fourier metrics of performance, valid only for linear and shift-invariant (LSI) systems and generally measured following IEC guidelines requiring the use of raw (unprocessed) image data. However, many detectors incorporate processing in the imaging chain that is difficult or impossible to disable, raising questions about the practical relevance of MTF and DQE testing. We investigate the impact of convolution-based embedded processing on MTF and DQE measurements. Approach: We use an impulse-sampled notation, consistent with a cascaded-systems analysis in spatial and spatial-frequency domains to determine the impact of discrete convolution (DC) on measured MTF and DQE following IEC guidelines. Results: We show that digital systems remain LSI if we acknowledge both image pixel values and convolution kernels represent scaled Dirac δ-functions with an implied sinc convolution of image data. This enables use of the Fourier transform (FT) to determine impact on presampling MTF and DQE measurements. Conclusions: It is concluded that: (i) the MTF of DC is always an unbounded cosine series; (ii) the slanted-edge method yields the true presampling MTF, even when using processed images, with processing appearing as an analytic filter with cosine-series MTF applied to raw presampling image data; (iii) the DQE is unaffected by discrete-convolution-based processing with a possible exception near zero-points in the presampling MTF; and (iv) the FT of the impulse-sampled notation is equivalent to the Z transform of image data.

2.
Magn Reson Med ; 78(4): 1599-1606, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-27779779

RESUMO

PURPOSE: To develop a new method capable of directly measuring specific absorption rate (SAR) deposited in tissue using the thermoacoustic signal induced by short radiofrequency (RF) pulse excitation. THEORY: A detailed model based on the thermoacoustic wave generation and propagation is presented. METHODS: We propose a new concept for direct measurement of SAR, to be used as a safety assessment/monitoring tool for MRI. The concept involves the use of short bursts of RF energy and the measurement of the resulting thermoacoustic excitation pattern by an array of ultrasound transducers, followed by image reconstruction to yield the 3D SAR distribution. We developed a simulation framework to model this thermoacoustic SAR mapping concept and verified the concept in vitro. RESULTS: Simulations show good agreement between reconstructed and original SAR distributions with an error of 4.2, 7.2, and 8.4% of the mean SAR values in axial, sagittal, and coronal planes and support the feasibility of direct experimental mapping of SAR distributions in vivo. The in vitro experiments show good agreement with theory (r2 = 0.52). CONCLUSIONS: A novel thermoacoustic method for in vivo mapping of local SAR patterns in MRI has been proposed and verified in simulation and in a phantom experiment. Magn Reson Med 78:1599-1606, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Acústica/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Absorção Fisico-Química , Simulação por Computador , Desenho de Equipamento , Estudos de Viabilidade , Cabeça/diagnóstico por imagem , Temperatura Alta , Humanos , Modelos Biológicos , Imagens de Fantasmas
3.
Radiology ; 235(2): 595-603, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15858099

RESUMO

PURPOSE: To retrospectively investigate regional in vivo magnetic resonance (MR) imaging transverse and longitudinal relaxation rates at 3.0 T in neonatal brain, the relationship between these rates, and their potential use for gray matter (GM) versus white matter (WM) tissue discrimination. MATERIALS AND METHODS: Informed parental consent for performance of imaging procedures was obtained in each infant. Informed consent for retrospective image analysis was not required; ethics approval was obtained from institutional review board. At 3.0 T, R1 and R2 were measured in brain regions (frontal WM, posterior WM, periventricular WM, frontal GM, posterior GM, basal ganglia, and thalamus) in 13 infants with suspected neurologic abnormality (two term, 11 preterm). Maps of R1 and R2 were acquired with T1 by multiple readout pulses and segmented spin-echo echo-planar imaging sequences, respectively. Accuracy of R1 and R2 map acquisition methods was tested in phantoms by comparing them with inversion-recovery and spin-echo sequences, respectively. Statistical analysis included linear regression analysis to determine relationship between R1 and R2 and Wilcoxon signed rank test to investigate the potential for discrimination between GM and WM. RESULTS: In phantoms, R1 values measured with T1 by multiple readout pulses sequence were 3%-8% lower than those measured with inversion recovery sequence, and R2 values measured with segmented echo-planar sequence were 1%-8% lower than those measured with spin-echo sequence. A strong correlation of 0.944 (P < .001) between R1 and R2 in neonatal brain was observed. For R2, relative differences between GM and WM were larger than were those for R1 (z = -2.366, P < .05). For frontal GM and frontal WM, (R2(GM) - R2(WM))/R2(WM) yielded 0.8 +/- 0.2 (mean +/- standard deviation) and (R1(GM) - R1(WM))/R1(WM) yielded 0.3 +/- 0.09. CONCLUSION: Results at 3.0 T indicate that R1 decreases with increasing field strength, while R2 values are similar to those reported at lower field strengths. For neonates, R2 image contrast may be more advantageous than R1 image contrast for differentiation between GM and WM.


Assuntos
Encefalopatias/congênito , Encéfalo/patologia , Aumento da Imagem , Processamento de Imagem Assistida por Computador , Doenças do Prematuro/diagnóstico , Imageamento por Ressonância Magnética , Encefalopatias/diagnóstico , Mapeamento Encefálico , Dominância Cerebral/fisiologia , Imagem Ecoplanar , Humanos , Recém-Nascido , Leucomalácia Periventricular/diagnóstico , Imagens de Fantasmas , Valores de Referência , Análise de Regressão , Estudos Retrospectivos
4.
Pediatr Res ; 51(5): 564-70, 2002 May.
Artigo em Inglês | MEDLINE | ID: mdl-11978878

RESUMO

Severely premature infants are often at increased risk of cerebral hemorrhage and/or ischemic injury caused by immature autoregulatory control of blood flow to the brain. If blood flow is too high, the infant is at risk of hemorrhage, whereas too little blood flow can result in ischemic injury. The development of a noninvasive, bedside means of measuring cerebral hemodynamics would greatly facilitate both diagnosis and monitoring of afflicted individuals. It is to this end that we have developed a near infrared spectroscopy (NIRS) system that allows for quantitative, bedside measurement of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). The technique requires an i.v. injection of the near infrared chromophore indocyanine green. Six newborn piglets, median age of 18 h (range 6-54 h), median weight of 1.75 kg (range 1.5-2.1 kg), were studied. Measurements of CBF, CBV, and MTT were made at normocapnia, hypocapnia, and hypercapnia to test the technique over a range of hemodynamic conditions. The accuracy of our new approach has been determined by direct comparison with measurements made using a previously validated computed tomography technique. Paired t tests showed no significant difference between computed tomography and NIRS measurements of CBF, CBV, and MTT, and mean biases between the two methods were -2.05 mL x min(-1) x 100 g(-1), -0.18 mL x 100 g(-1), and 0.43 s, respectively. The precision of NIRS CBF, CBV, and MTT measurements, as determined by repeated-measures ANOVA, was 9.71%, 13.05%, and 7.57%, respectively.


Assuntos
Animais Recém-Nascidos/fisiologia , Circulação Cerebrovascular/fisiologia , Espectrofotometria Infravermelho/métodos , Animais , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Corantes Fluorescentes , Hipercapnia/fisiopatologia , Hipocapnia/fisiopatologia , Verde de Indocianina , Modelos Animais , Espectrofotometria Infravermelho/instrumentação , Suínos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA