Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JACC Cardiovasc Interv ; 15(6): 590-598, 2022 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-35331450

RESUMO

OBJECTIVES: The aim of this study was to determine the safety and efficacy of same-day discharge (SDD) after transcatheter aortic valve replacement (TAVR) during the COVID-19 pandemic. BACKGROUND: The COVID-19 pandemic has placed significant stress on health care systems worldwide. SDD in highly selected TAVR patients can facilitate the provision of essential cardiovascular care while managing competing COVID-19 resource demands. METHODS: Patient selection for SDD was at the discretion of the local multidisciplinary heart team, across 7 international sites. The primary outcome was a composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new permanent pacemaker (PPM) implantation. RESULTS: From March 2020 to August 2021, 124 of 2,100 patients who underwent elective transfemoral TAVR were selected for SDD. The average age was 78.9 ± 7.8 years, the median Society of Thoracic Surgeons score was 2.4 (IQR: 1.4-4.2), and 32.3% (n = 40) had preexisting PPMs. There were no major vascular complications, strokes, or deaths during the index admission. One patient (0.8%) required PPM implantation for complete heart block and was discharged the same day. No patient required a PPM between discharge home and 30-day follow-up. The composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new PPM at 30 days occurred in 5.7% patients (n = 6 of 106). CONCLUSIONS: SDD post-TAVR is safe and feasible in selected patients at low risk for adverse clinical events postdischarge. This strategy may have a potential role in highly selected patients even when the COVID-19 pandemic abates.


Assuntos
Estenose da Valva Aórtica , COVID-19 , Substituição da Valva Aórtica Transcateter , Assistência ao Convalescente , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Humanos , Pandemias , Alta do Paciente , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 99(4): 1243-1250, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34851550

RESUMO

OBJECTIVE: The purpose of this study is to assess the utility of ambulatory cardiac monitoring (ACM) in detecting delayed advanced conduction abnormalities (DACA) and associated 30-day mortality. BACKGROUND: DACA are well-known complications of TAVR and may be associated with post-discharge mortality within 30-days. METHODS: Between October 2019 and October 2020, TAVR patients who were discharged home without a permanent pacemaker (PPM) were monitored with an ACM device for 14-days. The incidence of DACA at follow up, mortality and readmission within 30-days were investigated. The risk of DACA was assessed in three patient categories based on a composite of their 12-lead electrocardiogram (ECG) data. Group I: Normal pre-TAVR, periprocedural, and discharge ECGs. Group II: Normal pre-TAVR and abnormal subsequent ECGs. Group III. Abnormal baseline and abnormal subsequent ECGs. RESULTS: Among 340 TAVR patients, 248 were discharged home with an ACM device. The overall incidence of DACA was 7% (n = 17), of whom 4% (n = 10) required a PPM. Mortality and readmission between discharge and 30 days was 0% and 8.3%, respectively. Stratification of patients identified 96 (38.7%) patients in Group I: 50 (20%) in Group II, and 102 (41%) in Group III. The incidence of DACA requiring a PPM was 0% in Group I, 4% (n = 2) in Group II, and 8.5% (n = 8) in Group III (p < 0.004). CONCLUSIONS: In TAVR patients who were discharged home with ACM, none died between discharge and 30-days. For those with normal baseline, perioperative and discharge ECG, there were no events of DACA at 14-days.


Assuntos
Estenose da Valva Aórtica , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Assistência ao Convalescente , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Arritmias Cardíacas/etiologia , Estimulação Cardíaca Artificial/efeitos adversos , Eletrocardiografia/efeitos adversos , Humanos , Marca-Passo Artificial/efeitos adversos , Alta do Paciente , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA