Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
Arq Bras Cardiol ; 121(6): e20230684, 2024 Jun.
Artigo em Português, Inglês | MEDLINE | ID: mdl-39109691

RESUMO

BACKGROUND: There are no randomized studies comparing the maintenance of sinus rhythm after catheter ablation (CA) concerning treatment with antiarrhythmic drugs (AA) in elderly patients with paroxysmal atrial fibrillation (AF). OBJECTIVES: To compare the clinical results of pulmonary vein (PV) isolation with the second-generation PVAC Gold catheter against AA treatment in elderly people with recurrent symptomatic paroxysmal AF, refractory to at least one AA, and without structural heart disease. METHODS: Sixty patients with paroxysmal AF ≥ 65 years old were randomized to two forms of treatment: group 1: CA and group 2: AA drugs. The primary outcome was the AF recurrence-free rate after at least one year of follow-up. Secondary outcomes were: progression to persistent forms of AF, impact on quality of life (QOLF), and complications. The significance level adopted in the statistical analysis was 5% (p<0.05). RESULTS: The AF recurrence-free rate was 80% (10% with amiodarone) in the CA group, after 1.3 procedures per patient and 65% in the AA group (60% with amiodarone), (p = 0.119) in an average follow-up of 719 days (Q1: 566; Q3: 730). The persistent AF free rate was 83.4% in the AC group and 67.7% in the AA group (p = 0.073) Both strategies showed an improvement in the AFQoL score during follow-up (p < 0.001), with no difference between the groups. Although without clinical repercussions or impact on the intellectual assessment test, 25% of patients in the CA group showed signs of cerebral embolization on brain MRI. CONCLUSIONS: Both strategies for maintaining sinus rhythm promoted an improvement in the quality of life of elderly patients with symptomatic AF, with no statistical difference in the clinical outcomes. Additional studies using technologies with a better safety profile are needed to evaluate the benefits of CA in elderly patients with AF.


FUNDAMENTO: Não existem estudos randomizados comparando a manutenção do ritmo sinusal após ablação por cateter (AC) em relação ao tratamento com fármacos antiarrítmicos (AA) em pacientes idosos portadores fibrilação atrial (FA) paroxística. OBJETIVOS: Comparar os resultados clínicos do isolamento das veias pulmonares (VPs) com o cateter PVAC Gold de segunda geração com o uso de AA em idosos com FA paroxística sintomática, recorrente, apesar do uso de fármacos AA. MÉTODOS: Sessenta pacientes com FA paroxística ≥ 65 anos e sem cardiopatias estruturais foram randomizados para duas formas de tratamento: grupo 1: AC e grupo 2: AA. O desfecho primário foi a taxa livre de recorrência de FA após pelo menos um ano de seguimento. Os desfechos secundários foram: progressão para formas persistentes de FA, impacto na qualidade de vida (QVFA) e complicações. O nível de significância adotado na análise estatística foi de 5% (p<0,05). RESULTADOS: A taxa livre de recorrência de FA foi de 80% (10% com amiodarona) no grupo AC, após 1,3 procedimentos por paciente e de 65% no grupo AA (60% com amiodarona), (p = 0,119) num seguimento médio de 719 dias (Q1: 566; Q3: 730). A taxa livre de FA persistente foi de 83,4% no grupo AC e de 67,7% no grupo AA (p = 0,073). Ambas as estratégias apresentaram melhora no escore de QVFA durante o seguimento (p < 0,001), sem diferença entre os grupos. Embora sem repercussão clínica ou impacto no teste de avaliação intelectual, 25% dos pacientes do grupo PVAC apresentou sinais de embolização cerebral na RNM cerebral. CONCLUSÕES: Ambas as estratégias para manutenção do ritmo sinusal promoveram melhora na qualidade de vida de pacientes idosos com FA sintomática, sem diferença estatística nos desfechos clínicos preconizados. Estudos adicionais usando tecnologias com melhor perfil de segurança são necessários para avaliar os benefícios da AC em pacientes idosos com FA.


Assuntos
Antiarrítmicos , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Qualidade de Vida , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Antiarrítmicos/uso terapêutico , Feminino , Masculino , Idoso , Ablação por Cateter/métodos , Resultado do Tratamento , Veias Pulmonares/cirurgia , Recidiva , Amiodarona/uso terapêutico , Fatores de Tempo
5.
JACC Clin Electrophysiol ; 9(11): 2315-2328, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37676203

RESUMO

BACKGROUND: The subxiphoid pericardial access is technically difficult and has a considerable rate of complications, thus transatrial access may be an alternative. OBJECTIVES: This study sought to assess the feasibility and safety of this strategy regarding periprocedural period and after 1-week follow-up. METHODS: The investigators performed epicardial mapping through transatrial puncture in 20 swine. Animals were divided into group A, in which aspiration of the sheath was performed to maintain negative pressure after the withdraw of the catheters, and group B, in which a device (Konar-MF VSD Occluder) was delivered to occlude the right atrial appendage perforation. Bleeding was investigated immediately and 1 week after. RESULTS: Access was safe in 19 of 20 animals (95%) with small amount of bleeding (6.4 ± 6 mL). In group A (n = 10), 1 animal presented hemopericardium right after the puncture. In the other 9, epicardial ablation was performed and 60.0 ± 28.0 mL of blood was aspirated without events. After 1 week, fibrin-hemorrhagic pericarditis was identified in 3 animals. In group B (n = 10), reaching the epicardial surface was possible in all animals. An adequate position of the prosthesis was obtained in 90% (9 of 10). One death occurred in the immediate postoperative period, secondary to pneumothorax. After 1 week, postmortem analysis showed absence of pericardial bleeding and a normal-appearing pericardium in the 8 animals with adequate prosthesis position. CONCLUSIONS: Transatrial access allows epicardial mapping and ablation. Sheath removal after negative pressure contributes to achieving acute bleeding control but does not prevent its occurrence. The use of the device prevents bleeding and hemorrhagic pericarditis.


Assuntos
Mapeamento Epicárdico , Pericardite , Animais , Suínos , Estudos de Viabilidade , Mapeamento Epicárdico/métodos , Pericárdio/cirurgia , Hemorragia/etiologia
8.
J Interv Card Electrophysiol ; 66(7): 1581-1587, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36602693

RESUMO

BACKGROUND: Cardiac magnetic resonance (CMR) allowed to precisely identify the substrate in scar-related ventricular tachycardia (VT). New software has been developed to define the 3D scar and corridors to help VT ablation by integrating the scar and electroanatomical mapping (EAM). The objective of this study is to evaluate the results of VT ablation aided by the integration of EAM and CMR software processed scar. METHODS: We selected patients that underwent VT ablation with the integration of EAM and CMR processed using ADAS software and imported to the CARTO system using VTK file format. RESULTS: From 2019 to 2021, eight patients (mean age 63 ± 4.4, 62.5% male; EF 47 ± 12%) underwent CMR-aided VT ablation. Mean procedural time was 281 ± 77 min. There was of 9 ± 4.4 epicardial and 7.9 ± 4.3 endocardial bulls eye segments with at least 2 g of border zone or core scar. In a median follow-up time of 532 days (Q1: 284, Q3: 688), three patients (37.5%) presented VT recurrence, all three underwent a second procedure, with no VT recurrence on the follow-up. No patient died in the follow-up. CONCLUSION: CMR aided is ablation is feasible and effective in patients with scar related VT.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Masculino , Feminino , Cicatriz/diagnóstico por imagem , Cicatriz/cirurgia , Cicatriz/patologia , Resultado do Tratamento , Imageamento por Ressonância Magnética/métodos , Taquicardia Ventricular/diagnóstico por imagem , Taquicardia Ventricular/cirurgia , Espectroscopia de Ressonância Magnética , Ablação por Cateter/métodos
13.
J Am Coll Cardiol ; 77(9): 1225-1242, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33663741

RESUMO

Chagas disease is caused by infection from the protozoan parasite Trypanosoma cruzi. Although it is endemic to Latin America, global migration has led to an increased incidence of Chagas in Europe, Asia, Australia, and North America. Following acute infection, up to 30% of patients will develop chronic Chagas disease, with most patients developing Chagasic cardiomyopathy. Chronic Chagas cardiomyopathy is highly arrhythmogenic, with estimated annual rates of appropriate implantable cardioverter-defibrillator therapies and electrical storm of 25% and 9.1%, respectively. Managing arrhythmias in patients with Chagasic cardiomyopathy is a major challenge for the clinical electrophysiologist, requiring intimate knowledge of cardiac anatomy, advanced training, and expertise. Endocardial-epicardial mapping and ablation strategy is needed to treat arrhythmias in this patient population, owing to the suboptimal long-term success rate of endocardial mapping and ablation alone. We also describe innovative approaches to improve acute and long-term clinical outcomes in patients with refractory ventricular arrhythmias following catheter ablation, such as bilateral cervicothoracic sympathectomy and bilateral renal denervation, among others.


Assuntos
Denervação Autônoma/tendências , Ablação por Cateter/tendências , Cardiomiopatia Chagásica/epidemiologia , Cardiomiopatia Chagásica/terapia , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/terapia , Denervação Autônoma/métodos , Ablação por Cateter/métodos , Cardiomiopatia Chagásica/diagnóstico por imagem , Desfibriladores Implantáveis/tendências , Mapeamento Epicárdico/métodos , Mapeamento Epicárdico/tendências , Humanos , Rim/inervação , Rim/fisiologia , Literatura de Revisão como Assunto , Taquicardia Ventricular/diagnóstico por imagem , Resultado do Tratamento
14.
Arq. bras. cardiol ; 116(3): 454-463, Mar. 2021. tab, graf
Artigo em Português | LILACS | ID: biblio-1248868

RESUMO

Resumo Fundamento O diagnóstico diferencial de taquicardia de QRS largo, entre taquicardia ventricular (TV) ou taquicardia supraventricular com condução aberrante (TSV-A) é algumas vezes difícil de ser feito na sala de emergência. Objetivo Avaliar a acurácia de um algoritmo novo e simples para a detecção de TV no eletrocardiograma (ECG) em pacientes com taquicardia de QRS largo. Métodos ECGs de 12 derivações para detecção de taquicardia de QRS largo foram obtidos prospectivamente de 120 pacientes durante estudo eletrofisiológico. Seis médicos com diferentes experiências analisaram os ECGs, e fizeram o diagnóstico com base no algoritmo D12V16, que envolve a análise da polaridade predominante do complexo QRS nas derivações I, II, V1 e V6. O diagnóstico foi comparado com os obtidos pelo algoritmo tradicional de Brugada e pelo estudo eletrofisiológico, o qual é considerado padrão ouro. Adotou-se um nível de significância de 5% (p<0,05) nas análises estatísticas. Resultados De acordo com o estudo eletrofisiológico, 82 ECGs eram de TV e 38 de TSV-A. Doenças cardíacas estruturais estavam presentes em 71 (86,6%) dos pacientes com TV e em oito (21,1%) com TSV-A. O algoritmo de Brugada teve uma maior sensibilidade global (87,2%), enquanto o algoritmo D12V16 apresentou maior especificidade global (85,1%) para TV. Tanto o algoritmo D12V16 como o de Brugada apresentou um alto valor preditivo positivo (90,9% vs. 85,8%, respectivamente) e acurácia similar (73,8% vs. 81,4%, respectivamente) para o diagnóstico de TV. Nos avaliadores experientes, a acurácia foi maior utilizando o algoritmo de Brugada que o algoritmo D12V16, mas a acurácia dos dois algoritmos foi similar segundo os avaliadores menos experientes. Conclusão O algoritmo simplificado pode ser um método útil para reconhecer TV no ECG, principalmente para médicos menos experientes. (Arq Bras Cardiol. 2021; [online].ahead print, PP.0-0)


Abstract Background The differential diagnosis of wide QRS complex tachycardia (WCT) between ventricular tachycardia (VT) or supraventricular tachycardia with aberrant conduction (SVT-A) is sometimes difficult in the emergency room. Objective The aim of this study was to evaluate the accuracy of a new simple electrocardiographic algorithm to recognize VT in patients with wide complex tachycardia. Methods The 12-lead electrocardiograms (ECG) for WCT were prospectively obtained from 120 patients during electrophysiological study. Six physicians with different expertise analyzed the electrocardiographic recordings, and made the diagnosis based on the D12V16 algorithm, that involves the analysis of the predominant polarity of QRS in leads I, II, V1 and V6. The diagnosis was compared with that made using the traditional Brugada algorithm and the "gold-standard" electrophysiological study. Statistical analyses were performed with a significance level of 5% (p<0.05). Results According to the EPS study, 82 ECG recordings were VT and 38 SVT-A. Structural heart diseases were present in 71 (86.6%) patients with VT and in 8 (21.1%) with SVT-A. The Brugada algorithm had higher global sensitivity (87.2%), and the D12V16 algorithm had higher global specificity (85.1%) for VT. Both D12V16 and Brugada's algorithms presented a high positive predictive value (90.9% vs 85.8%, respectively) and similar accuracy (73.8% vs 81.4%, respectively) for the diagnosis of VT. Experienced evaluators were more accurate using Brugada algorithm than the D12V16 algorithm, but the accuracy of both algorithms was similar according to less experienced examiners. Conclusion The simplified algorithm may be a useful method to recognize VT in the ECG, especially for less experienced doctors. (Arq Bras Cardiol. 2021; [online].ahead print, PP.0-0)


Assuntos
Humanos , Taquicardia Supraventricular , Taquicardia Ventricular/diagnóstico , Algoritmos , Sensibilidade e Especificidade , Diagnóstico Diferencial , Eletrocardiografia , Frequência Cardíaca
15.
Arq Bras Cardiol ; 116(3): 454-463, 2021 03.
Artigo em Inglês, Português | MEDLINE | ID: mdl-33566932

RESUMO

BACKGROUND: The differential diagnosis of wide QRS complex tachycardia (WCT) between ventricular tachycardia (VT) or supraventricular tachycardia with aberrant conduction (SVT-A) is sometimes difficult in the emergency room. OBJECTIVE: The aim of this study was to evaluate the accuracy of a new simple electrocardiographic algorithm to recognize VT in patients with wide complex tachycardia. METHODS: The 12-lead electrocardiograms (ECG) for WCT were prospectively obtained from 120 patients during electrophysiological study. Six physicians with different expertise analyzed the electrocardiographic recordings, and made the diagnosis based on the D12V16 algorithm, that involves the analysis of the predominant polarity of QRS in leads I, II, V1 and V6. The diagnosis was compared with that made using the traditional Brugada algorithm and the "gold-standard" electrophysiological study. Statistical analyses were performed with a significance level of 5% (p<0.05). RESULTS: According to the EPS study, 82 ECG recordings were VT and 38 SVT-A. Structural heart diseases were present in 71 (86.6%) patients with VT and in 8 (21.1%) with SVT-A. The Brugada algorithm had higher global sensitivity (87.2%), and the D12V16 algorithm had higher global specificity (85.1%) for VT. Both D12V16 and Brugada's algorithms presented a high positive predictive value (90.9% vs 85.8%, respectively) and similar accuracy (73.8% vs 81.4%, respectively) for the diagnosis of VT. Experienced evaluators were more accurate using Brugada algorithm than the D12V16 algorithm, but the accuracy of both algorithms was similar according to less experienced examiners. CONCLUSION: The simplified algorithm may be a useful method to recognize VT in the ECG, especially for less experienced doctors. (Arq Bras Cardiol. 2021; [online].ahead print, PP.0-0).


FUNDAMENTO: O diagnóstico diferencial de taquicardia de QRS largo, entre taquicardia ventricular (TV) ou taquicardia supraventricular com condução aberrante (TSV-A) é algumas vezes difícil de ser feito na sala de emergência. OBJETIVO: Avaliar a acurácia de um algoritmo novo e simples para a detecção de TV no eletrocardiograma (ECG) em pacientes com taquicardia de QRS largo. MÉTODOS: ECGs de 12 derivações para detecção de taquicardia de QRS largo foram obtidos prospectivamente de 120 pacientes durante estudo eletrofisiológico. Seis médicos com diferentes experiências analisaram os ECGs, e fizeram o diagnóstico com base no algoritmo D12V16, que envolve a análise da polaridade predominante do complexo QRS nas derivações I, II, V1 e V6. O diagnóstico foi comparado com os obtidos pelo algoritmo tradicional de Brugada e pelo estudo eletrofisiológico, o qual é considerado padrão ouro. Adotou-se um nível de significância de 5% (p<0,05) nas análises estatísticas. RESULTADOS: De acordo com o estudo eletrofisiológico, 82 ECGs eram de TV e 38 de TSV-A. Doenças cardíacas estruturais estavam presentes em 71 (86,6%) dos pacientes com TV e em oito (21,1%) com TSV-A. O algoritmo de Brugada teve uma maior sensibilidade global (87,2%), enquanto o algoritmo D12V16 apresentou maior especificidade global (85,1%) para TV. Tanto o algoritmo D12V16 como o de Brugada apresentou um alto valor preditivo positivo (90,9% vs. 85,8%, respectivamente) e acurácia similar (73,8% vs. 81,4%, respectivamente) para o diagnóstico de TV. Nos avaliadores experientes, a acurácia foi maior utilizando o algoritmo de Brugada que o algoritmo D12V16, mas a acurácia dos dois algoritmos foi similar segundo os avaliadores menos experientes. CONCLUSÃO: O algoritmo simplificado pode ser um método útil para reconhecer TV no ECG, principalmente para médicos menos experientes. (Arq Bras Cardiol. 2021; [online].ahead print, PP.0-0).


Assuntos
Taquicardia Supraventricular , Taquicardia Ventricular , Algoritmos , Diagnóstico Diferencial , Eletrocardiografia , Frequência Cardíaca , Humanos , Sensibilidade e Especificidade , Taquicardia Ventricular/diagnóstico
18.
J Cardiovasc Electrophysiol ; 31(6): 1413-1419, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32298040

RESUMO

INTRODUCTION: Catheter ablation of the parahisian accessory pathways (PHAP) has been established as the definitive therapy for this type of arrhythmia. However, the PHAP proximity to the normal atrioventricular conduction system makes the procedure technically challenging. Here, we have reported a case series of 20 patients with PHAP who underwent aortic access ablation to evaluate the safety and efficacy of this approach in the PHAP ablation. METHODS AND RESULTS: The ablation through the aortic cusps was the successful approach in 13 of 20 (65%) of the cases. In 11 patients, the aortic approach was the initial strategy for ablation, and the accessory pathway was eliminated in seven (63.6%) of them. The aortic approach followed a failed right-sided attempt in nine patients. In six (66.7%) patients, the ablation was successful with the aortic approach. The only independent predictor for the successful ablation with each approach was the earliest ventricular activation before delta wave (predelta time) and a right-sided earliest ventricular activation of more than 23 ms had high sensitivity and specificity for right-sided success. Systematically using the two strategies (right and left approaches), the ablation of the PHAP was successful in 18 (90%) patients. CONCLUSION: The aortic approach seems to be a safe and effective strategy for the ablation of PHAP. It can be used when the right-sided approach fails or even considered as an initial strategy when the predelta time is less than 23 ms in the right septal region. When combining the right- and left-sided approaches, the success rate is high. We believe that the retrograde aortic approach remains a key tool for this challenging ablation.


Assuntos
Feixe Acessório Atrioventricular/cirurgia , Arritmias Cardíacas/cirurgia , Ablação por Cateter , Técnicas Eletrofisiológicas Cardíacas , Feixe Acessório Atrioventricular/fisiopatologia , Potenciais de Ação , Adulto , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Ablação por Cateter/efeitos adversos , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Valor Preditivo dos Testes , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
20.
J Cardiovasc Electrophysiol ; 31(4): 924-933, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32108399

RESUMO

OBJECTIVE: To compare the prevalence of esophageal and periesophageal thermal injury in patients undergoing radiofrequency (RF) atrial fibrillation (AF) ablation using 8 mm tip catheters during three different esophageal protection strategies. METHODS: Forty-five consecutive patients with paroxysmal or persistent AF underwent first ablation procedure, besides esophagogastroduodenoscopy (EGD) combined with radial endosonography (EUS) performed before and after the pulmonary vein (PV) isolation. Before the procedure, patients were randomly assigned to one of three esophageal lesion protection strategies: group I-without any protective or monitoring dispositive and limiting RF applications to 30 W for 20 seconds, in left atrium posterior wall (LAPW); group II-power and time of RF delivery, up to 50 W for 20 seconds at LAPW, limited by esophageal temperature monitoring; group III-applications of RF in LAPW with fixed power application of 50 W for 20 seconds during continuous esophageal cooling. RESULTS: Baseline characteristics of patients were similar in all groups. The four PVs were isolated in 14 (93.3%), 13 (86.7%), and 15 (100%) patients, respectively in groups I, II, and III. The mean RF power was significantly higher (P < .001) in the posterior side of PVs in group III. Post-AF ablation EGD and EUS revealed two esophageal wall ulcerations and two periesophageal mediastinal edemas only in the esophageal cooling group (P = .008). CONCLUSION: Esophageal cooling balloon strategy resulted in a higher RF power energy delivery when ablating at the LA posterior wall, using 8 mm nonirrigated tip catheters under temperature mode control. Despite that, patients presented a relatively low incidence of esophageal and periesophaeal injuries.


Assuntos
Fibrilação Atrial/cirurgia , Queimaduras/prevenção & controle , Ablação por Cateter , Esôfago/lesões , Veias Pulmonares/cirurgia , Adulto , Brasil , Queimaduras/diagnóstico por imagem , Queimaduras/epidemiologia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Desenho de Equipamento , Esôfago/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA