Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

2.
Am J Cardiol ; 221: 102-109, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38636623

RESUMO

Transcatheter aortic valve implantation (TAVI) is an established treatment strategy in aortic valve disease. Infolding, as a nonuniform expansion of the prosthesis leading to introflection of part of the device circumference, is a complication specific to self-expandable prostheses. The aim of the study is to determine incidence, predictors, treatment strategy, and outcomes of infolding during Medtronic Evolut TAVI (Minneapolis, MN, US). Between January 2018 and March 2022, all patients treated with Evolut TAVI were included in a multicenter observational retrospective study. According to the occurrence of infolding, the enrolled cohort was divided into 2 groups; periprocedural characteristics and 30-day outcomes were compared. A total of 1,470 patients were included; 23 infolding cases (1.6%) were detected. Preprocedural imaging showed larger aortic anatomy and greater calcium burden in the infolding group. Infolding occurred mostly with Evolut Pro+ and size 34 mm and was diagnosed before full prosthesis release in 78.3%. The rate of moderate-to-severe paravalvular regurgitation was higher in the infolding group (21.7% vs 1.9%, p <0.001). Short-term follow-up showed greater all-cause and cardiovascular mortality (respectively, 4.3% vs 0.7% and 4.3% vs 0.6%, p <0.05) and higher rate of pacemaker implantation (33.3% vs 15.7%, p = 0.042) in case of infolding. High right cusp calcium score and resheathing maneuvers were independent predictors of infolding. In conclusion, prosthesis infolding is a TAVI complication burdened by worse cardiovascular outcomes. Prompt intraprocedural infolding diagnosis is pivotal, especially in case of great native valve calcium burden and resheathing maneuvers, to safely overcome this complication by prosthesis recapture or postdilation.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Incidência , Idoso , Falha de Prótese , Complicações Pós-Operatórias/epidemiologia , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/epidemiologia
3.
Scand Cardiovasc J ; 57(1): 2278279, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37962426

RESUMO

OBJECTIVES: Patients receiving transcatheter aortic valve implantation (TAVI) are elderly with multiple comorbidities and at increased risk of perioperative cerebrovascular events. Retinal vasculature represents a surrogate of central nervous system circulation and is noninvasively achievable by retinal imaging. The aim of this study was to evaluate the applicability of retinal angiography of microvascular complications and association to cerebral ischemic events during TAVI. DESIGN: One hundred patients (male 54%, age: median 82 years, range 64-95 years) undergoing TAVI were recruited for this study. Imaging of retinal vasculature was evaluated with a handheld fundus camera before, during and 1 month after. Cerebrovascular events were determined as a part of contemporary clinical evaluation with cerebral CT and CTA imaging when symptoms occurred. RESULTS: Altogether 66/100 patients (66%) were included in the analysis. In-hospital ischemic event (transient ischemic attack, cerebral infarction) was observed in 1/66 patient (1.5%). Retinal vascular abnormalities occurred in 8/66 patients (12.1%); 4/66 patients (6.1%) were detected with a cholesterol plaque in the retinal artery, 2/66 (3%) a capillary leakage, 1/66 (1.5%) and optic disk hemorrhage and 1/66 (1.5%) a macular bleeding. No significant association between retinal vasculature abnormalities and cerebrovascular events was detected mainly due to the low event rate. CONCLUSIONS: Perioperative evaluation of cerebrovascular ischemia with noninvasive imaging of retinal vasculature is possible in most patients undergoing TAVI. More data is needed to evaluate the association of cerebrovascular events and retinal microvascular abnormalities during the procedure.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Angiografia , Fatores de Risco
4.
Scand Cardiovasc J ; 57(1): 2251730, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37641930

RESUMO

Objectives. Remote ischemic preconditioning (RIPC) mitigates acute myocardial infarction (AMI). We hypothesized that RIPC reduces the size and severity of AMI and explored molecular mechanisms behind this phenomenon. Design. In two series of experiments, piglets underwent 60 min of the circumflex coronary artery occlusion, resulting in AMI. Piglets were randomly assigned into the RIPC groups (n = 7 + 7) and the control groups (n = 7 + 7). The RIPC groups underwent four 5-min hind limb ischemia-reperfusion cycles before AMI. In series I, the protective efficacy of RIPC was investigated by using biomarkers and echocardiography with a follow-up of 24 h. In series II, the heart of each piglet was harvested for TTC-staining to measure infarct size. Muscle biopsies were collected from the hind limb to explore molecular mechanisms of RIPC using qPCR and Western blot analysis. Results. The levels of CK-MBm (p = 0.032) and TnI (p = 0.007) were lower in the RIPC group. Left ventricular ejection fraction in the RIPC group was greater at the end of the follow-up. The myocardial infarct size in the RIPC group was smaller (p = 0.033). Western blot indicated HIF1α stabilization in the skeletal muscle of the RIPC group. PCR analyses showed upregulation of the HIF target mRNAs for glucose transporter (GLUT1), glucose transporter 4 (GLUT4), phosphofructokinase 1 (PFK1), glyceraldehyde 3-phosphate dehydrogenase (GAPDH), enolase 1 (ENO1), lactate dehydrogenase (LDHA) and endothelial nitric oxidate synthase (eNOS). Conclusions. Biochemical, physiologic, and histologic evidence confirms that RIPC decreases the size of AMI. The HIF pathway is likely involved in the mechanism of the RIPC.


Assuntos
Precondicionamento Isquêmico , Infarto do Miocárdio , Animais , Suínos , Volume Sistólico , Função Ventricular Esquerda , Biomarcadores
5.
Commun Med (Lond) ; 3(1): 87, 2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37349571

RESUMO

BACKGROUND: All coronary artery disease (CAD) patients do not benefit equally of secondary prevention. Individualized intensity of drug therapy is currently implemented in guidelines for CAD and diabetes. Novel biomarkers are needed to identify patient subgroups potentially benefitting from individual therapy. This study aimed to investigate endothelin-1 (ET-1) as a biomarker for increased risk of adverse events and to evaluate if medication could alleviate the risks in patients with high ET-1. METHODS: A prospective observational cohort study ARTEMIS included 1946 patients with angiographically documented CAD. Blood samples and baseline data were collected at enrollment and the patients were followed for 11 years. Multivariable Cox regression was used to assess the association between circulating ET-1 level and all-cause mortality, cardiovascular (CV) death, non-CV death and sudden cardiac death (SCD). RESULTS: Here we show an association of circulating ET-1 level with higher risk for all-cause mortality (HR: 2.06; 95% CI 1.5-2.83), CV death, non-CV death and SCD in patients with CAD. Importantly, high intensity statin therapy reduces the risk for all-cause mortality (adjusted HR: 0.05; 95% CI 0.01-0.38) and CV death (adjusted HR: 0.06; 95% CI 0.01-0.44) in patients with high ET-1, but not in patients with low ET-1. High intensity statin therapy does not associate with reduction of risk for non-CV death or SCD. CONCLUSIONS: Our data suggests a prognostic value for high circulating ET-1 in patients with stable CAD. High intensity statin therapy associates with reduction of risk for all-cause mortality and CV death in CAD patients with high ET-1.


Patients with coronary artery disease (CAD) ­ in which the blood vessels supplying the heart become blocked - need careful management to prevent adverse outcomes related to their disease, such as a heart attack or sudden cardiac death. Identification of markers in the blood to predict adverse outcomes would help to improve the care of patients with CAD. Here, we find that higher circulating levels of endothelin-1 (ET-1), a protein secreted normally to maintain blood pressure, associate with greater risk of death in CAD patients. Cholesterol-lowering statin therapy used at high intensity (high dosage) can counteract the increased risk of death observed in CAD patients with high ET-1. Therefore, circulating ET-1 level could be used as a marker to predict the risk of death in CAD patients, and an indication for high intensity statin therapy. Our findings could help clinicians to improve the management of patients with CAD.

6.
Toxicol Rep ; 10: 521-528, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37152411

RESUMO

Dasatinib is a multitargeted kinase inhibitor used for treatment of chronic myeloid leukemia and acute lymphoblastic leukemia. Unfortunately, treatment of cancer patients with some kinase inhibitors has been associated with cardiotoxicity. Cancer treatment with dasatinib has been reported to be associated with cardiotoxic side effects such as left ventricular dysfunction, heart failure, pericardial effusion and pulmonary hypertension. Here we aimed to investigate the molecular mechanisms underlying the cardiotoxicity of dasatinib. We found that among the resident cardiac cell types, cardiomyocytes were most sensitive to dasatinib-induced cell death. Exposure of cardiomyocytes to dasatinib attenuated the activity of extracellular signal-regulated kinase (ERK), which is a downstream target of dasatinib target kinase c-Src. Similar to dasatinib, c-Src depletion in cardiomyocytes compromised cardiomyocyte viability. Overexpression of dasatinib-resistant mutant of c-Src rescued the toxicity of dasatinib on cardiomyocytes, whereas forced expression of wild type c-Src did not have protective effect. Collectively, our results show that c-Src is a key target of dasatinib mediating the toxicity of dasatinib to cardiomyocytes. These findings may influence future drug design and suggest closer monitoring of patients treated with agents targeting c-Src for possible adverse cardiac effects.

7.
Catheter Cardiovasc Interv ; 100(7): 1242-1251, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36378689

RESUMO

BACKGROUND: In patients with some cardiovascular disease conditions, slightly elevated body mass index (BMI) is associated with a lower mortality risk (termed "obesity paradox"). It is uncertain, however, if this obesity paradox exists in patients who have had invasive cardiology procedures. We evaluated the association between BMI and mortality in patients who underwent coronary angiography. METHODS: We utilised the KARDIO registry, which comprised data on demographics, prevalent diseases, risk factors, coronary angiographies, and interventions on 42,636 patients. BMI was categorised based on WHO cut-offs or transformed using P-splines. Hazard ratios (HRs) with 95% confidence intervals (CIs) were estimated for all-cause mortality. RESULTS: During a median follow-up of 4.9 years, 4688 all-cause deaths occurred. BMI was nonlinearly associated with mortality risk: compared to normal weight category (18.5-25 kg/m2 ), the age-adjusted HRs (95% CIs) for all-cause mortality were 1.90 (1.49, 2.43), 0.96 (0.92, 1.01), 1.04 (0.99, 1.09), 1.08 (0.96, 1.20), and 1.45 (1.22, 1.72) for underweight (<18.5 kg/m2 ), preobesity (25 to <30 kg/m2 ), obesity class I (30 to <35 kg/m2 ), obesity class II (35 to <40 kg/m2 ), and obesity class III (>40 kg/m2 ), respectively. The corresponding multivariable adjusted HRs (95% CIs) were 2.00 (1.55, 2.58), 0.92 (0.88, 0.97) 1.01 (0.95, 1.06), 1.10 (0.98, 1.23), and 1.49 (1.26, 1,78), respectively. CONCLUSIONS: In patients undergoing coronary angiography, underweight and obesity class III are associated with increased mortality risk, and the lowest mortality was observed in the preobesity class. It appears the obesity paradox may be present in patients who undergo invasive coronary procedures.


Assuntos
Cardiologia , Doenças Cardiovasculares , Humanos , Angiografia Coronária , Magreza/complicações , Resultado do Tratamento , Obesidade/complicações , Obesidade/diagnóstico , Obesidade/epidemiologia , Índice de Massa Corporal , Fatores de Risco
8.
Am J Cardiol ; 176: 96-104, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35643552

RESUMO

Recent studies showed the favorable outcomes of transcatheter aortic valve implantation (TAVI) in patients with bicuspid aortic valve (BAV) stenosis. However, data on the relation between BAV morphology and optimal transcatheter heart valve (THV) selection are limited. This study sought to evaluate the determinants of device performance in patients with BAV who underwent TAVI. Consecutive patients with BAV who underwent TAVI with the SAPIEN 3 from multicenters were evaluated. Outcomes were the incidence and predictors of device failure. Device failure was defined as peak aortic velocity >3.0 m/s, mean pressure gradient >20 mm Hg, moderate or severe paravalvular leakage and/or procedure mortality. A total of 187 patients with BAV were identified, aged 77 years, and 38.0% were women. A total of 37 patients (19.8%) were treated with 23-mm valve, 58 (31.0%) with 26-mm valve, and 92 (49.2%) with 29-mm valve. Predischarge echocardiogram demonstrated 37 patients (19.8%) with device failure. BAV with excessive leaflet calcification plus calcified raphe (EC-BAV) (OR 16.7, 95% CI 1.99 to 39.6) and smaller THV (OR 4.41, 95% CI 1.43 to 13.6) were independently associated with increased risk of device failure. In addition, 4.0%, 5.1%, and 11.1% of device failures were observed in patients without EC-BAV who underwent TAVI with 23-, 26- and 29-mm THV (p = 0.47), respectively, and 91.7%, 31.6% and 23.2% in those with EC-BAV, respectively (p <0.001). In conclusion, EC-BAV morphology was the major determinant of a device failure after TAVI. Moreover, TAVI in patients with EC-BAV requiring small SAPIEN 3 could be challenging. Further data on device and treatment selection in patients with BAV are still warranted.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Doenças das Valvas Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Falha de Equipamento , Feminino , Doenças das Valvas Cardíacas/cirurgia , Humanos , Masculino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 33(7): 1576-1586, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35543515

RESUMO

INTRODUCTION: Implantation depth and membranous septum (MS) length have been established as the predictors of new-onset conduction disturbance (CD) after transcatheter aortic valve replacement (TAVR) for tricuspid aortic valve (TAV) stenosis. However, little is known about the predictors with bicuspid aortic valve (BAV). This study investigated the role of MS length and implantation depth in predicting CD following TAVR with a balloon-expandable valve in patients with BAV. METHODS: This retrospective study analyzed 169 patients who underwent TAVR for BAV with balloon-expandable valve, and TAV cohort was established as a control group using propensity score (PS) matching. The primary endpoints were in-hospital new permanent pacemaker implantation (PPI) and new-onset CD (the composite outcome of new-onset left bundle branch block and new PPI). RESULTS: PPI developed in 14 patients (8.3%) and new-onset CD in 37 patients (21.9%) in the BAV cohort. Multivariate analysis revealed severe left ventricle outflow tract (LVOT) calcification (odds ratio [OR]: 5.83, 95% confidence interval [CI]: 1.08-31.5, p = .0407) and implantation depth-MS length (OR: 1.30, 95% CI: 1.12-1.51, p = .0005) as the predictors of new-onset CD within the BAV cohort. The matched comparison between BAV and TAV groups showed similar MS length (3.0 vs. 3.2 mm, p = .5307), but valves were implanted more deeply in the BAV group than in the TAV group (3.9 vs. 3.0 mm, p < .0001). New-onset CD was more frequent in patients who had BAV (22.3% vs. 13.9%, p = .0458). CONCLUSION: The implantation depth-MS length, and severe LVOT calcification predicted new-onset CD following TAVR in BAV with balloon-expandable valve. Among BAV patients, valves were implanted more deeply compared to TAV patients. High deployment technique could be considered to avoid new-onset CD in BAV anatomy.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Próteses Valvulares Cardíacas , Estenose da Valva Mitral , Substituição da Valva Aórtica Transcateter , Estenose da Valva Tricúspide , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Constrição Patológica/cirurgia , Humanos , Estenose da Valva Mitral/cirurgia , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento , Estenose da Valva Tricúspide/cirurgia
11.
Catheter Cardiovasc Interv ; 98(6): 1204-1209, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-34137483

RESUMO

OBJECTIVES: We aimed to determine the safety and efficacy of the Allegra transcatheter heart valve (THV) for the treatment of severe aortic valve stenosis in a large patient population treated under real-world conditions. BACKGROUND: The Allegra is a novel self-expanding THV with supra-annular bovine leaflets. The valve is available in three different sizes (23, 27, and 31 mm), all are delivered through an 18F sheath. METHODS: Consecutive patients undergoing TAVR with the Allegra THV were enrolled in a multicenter-registry. Data were collected throughout initial hospital-stay and at 30-day follow-up. Clinical endpoints were defined according to the updated definitions of the Valve-Academic-Research-Consortium. RESULTS: This registry included 255 patients (mean age 83 ± 6 years, 48% women) from four European centers. Median European System for Cardiac Operative Risk Evaluation II score (EuroSCORE II) was 3.3% (IQR 1.9-5.8%). Acute device success was 95.7%. The remaining 11 patients had either moderate paravalvular regurgitation immediately after the procedure (7 patients) or the device could not be optimal positioned requiring implantation of a second THV (4 patients). Major vascular complications and major/life-threatening bleedings occurred in 10 (3.9%) and 12 (4.7%) patients, respectively. At 30 day follow-up, mean effective orifice area was 2.2 ± 0.5 cm2 , mean gradient was 6.9 ± 3.8 mmHg, 7 (3.3%) patients had more than mild paravalvular leakage, 3 patients (1.2%) had died, 6 patients (2.4%) had a stroke and 30 (12.8%) patients had required implantation of a new permanent pacemaker. CONCLUSIONS: Transfemoral implantation of the Allegra THV resulted in favorable clinical and echocardiographic outcomes during hospitalization and short-term follow up.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Animais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Humanos , Masculino , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Terfenadina/análogos & derivados , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
12.
Can J Cardiol ; 37(1): 37-46, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32535038

RESUMO

BACKGROUND: The data on acute kidney injury (AKI) in patients without chronic kidney disease (CKD) after transcatheter aortic valve replacement (TAVR) are limited. The study sought to compare the incidence of AKI and its impact on 5-year mortality after TAVR and surgical aortic valve replacement (SAVR) in patients without CKD. METHODS: This registry included data from 6463 consecutive patients who underwent TAVR or SAVR. CKD was defined as estimated glomerular filtration rate <60 mL/min/1.73 m2. AKI was defined according to the Kidney Disease Improving Global Outcomes criteria. For sensitivity analysis, propensity-score matching between TAVR and SAVR was performed. RESULTS: The study included 4555 consecutive patients (TAVR, n = 1215 and SAVR, n = 3340) without CKD. Propensity-score matching identified 542 pairs. Patients who underwent TAVR had a significantly lower incidence of AKI in comparison to those who underwent SAVR (unmatched 4.7% vs 16.4%, P < 0.001, multivariable analysis: odds ratio, 0.29, 95% confidence interval [CI], 0.20-0.41; matched 5.9% vs 19.0%, P < 0.001). Patients with AKI had significantly increased 5-year mortality compared with those without AKI (unmatched 36.0% vs 19.1%, log-rank P < 0.001; matched 36.3% vs 24.0%, log-rank P < 0.001). The adjusted hazard ratios for 5-year mortality were 1.58 (95% CI, 1.20-2.08) for AKI grade 1, 3.27 (95% CI, 2.09-5.06) for grade 2, and 4.82 (95% CI, 2.93-8.04) for grade 3. CONCLUSIONS: TAVR in patients without CKD was associated with a significantly less frequent incidence of AKI compared with SAVR. AKI significantly increased the risk of 5-year mortality after either TAVR or SAVR, and increasing severity of AKI was incrementally associated with 5-year mortality.


Assuntos
Injúria Renal Aguda/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Injúria Renal Aguda/mortalidade , Idoso , Idoso de 80 Anos ou mais , Feminino , Finlândia/epidemiologia , Taxa de Filtração Glomerular , Humanos , Masculino , Análise por Pareamento , Análise Multivariada , Complicações Pós-Operatórias , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença
13.
Catheter Cardiovasc Interv ; 97(7): E982-E991, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32966682

RESUMO

OBJECTIVES: The study aims to compare the hemodynamic and clinical outcomes of the SAPIEN 3 Ultra (S3-Ultra) with the SAPIEN 3 (S3) system in patients who underwent transfemoral transcatheter aortic valve replacement (TF-TAVR). BACKGROUND: The new balloon-expandable S3-Ultra system incorporates new features to reduce paravalvular leakage (PVL). However, the data after the S3-Ultra implantation is very limited. METHODS: A total of 282 consecutive patients who underwent TF-TAVR with the S3-Ultra and the S3 were evaluated. The primary outcome of this study was to compare the incidence of ≥mild PVL after the S3-Ultra and S3 implantation. RESULTS: Between June 2017 and November 2019, 141 patients with the S3-Ultra and 141 patients with the S3 were identified with similar baseline and preprocedural imaging characteristics (mean age: 79.6 ± 6.7 years and mean aortic annulus area: 492.5 ± 91.2 mm2 ). In total, 83 patients (29.4%) were treated with 29-mm valve. Predischarge echocardiography demonstrated a significantly lower incidence of ≥mild PVL (the total cohort: 7.2 vs. 22.3%, p < .001, and the cohort excluding 29-mm valve: 4.0 vs. 21.4%, p = .03) for the S3-Ultra. The S3-Ultra system, especially 20-, 23-, and 26-mm valve, was associated with significantly lower risk of ≥mild PVL compared with the S3 system in multivariate analysis. There were no significant differences in clinical outcomes at 30-day between these groups, except for the lower incidence of major vascular complication (4.5 vs. 11.4%, p = .05) in patients with the S3-Ultra. CONCLUSIONS: In this registry, the S3-Ultra system performed superiorly to the S3, as demonstrated by reduced ≥mild PVL, with comparable safety.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
14.
Scand Cardiovasc J ; 54(6): 358-360, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32945201

RESUMO

We compared the ST elevation myocardial infarction (STEMI) incidence during COVID-19 pandemic (March 2020) to January-February 2020 and to same time period in earlier years 2017-2019 in five Nordic-Baltic tertiary centers. During 2017-2019, there were no marked differences in STEMI incidence between January, February and March. During 2020, there was an average drop of 32% in STEMI incidence in March. The isolation measures may decrease the risk for respiratory virus infection and contribute to the lower STEMI incidence and that we might benefit from firmer suggestions on hand hygiene and social distancing during flu season at least among high-risk individuals.


Assuntos
COVID-19 , Infarto do Miocárdio com Supradesnível do Segmento ST/epidemiologia , Humanos , Incidência , Letônia/epidemiologia , Estudos Retrospectivos , Países Escandinavos e Nórdicos/epidemiologia , Centros de Atenção Terciária/estatística & dados numéricos
15.
Circ Rep ; 2(3): 182-191, 2020 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-33693226

RESUMO

Background: The aim of this study was to investigate the impact of anatomical site status and major vascular complication (MVC) severity on the outcome of transfemoral transcatheter aortic valve replacement (TF-TAVR). Methods and Results: The FinnValve registry enrolled consecutive TAVR patients from 2008 to 2017. MVC was divided into 2 groups: non-access site-related MVC (i.e., MVC in aorta, aortic valve annulus or left ventricle); and access site-related MVC (i.e., MVC in iliac or femoral arteries). Severity of access site-related MVC was measured as units of red blood cell (RBC) transfusion. Of 1,842 patients who underwent TF-TAVR, 174 had MVC (9.4%; non-access site related, n=29; access site related, n=145). Patients with MVC had a significantly higher 3-year mortality than those without MVC (40.8% vs. 24.3%; HR, 2.01; 95% CI: 1.16-3.62). Adjusted 3-year mortality risk was significantly increased in the non-access site-related MVC group (mortality, 77.8%; HR, 4.30; 95% CI: 2.63-7.02), but not in the access site-related MVC group (mortality, 32.6%; HR, 1.38; 95% CI: 0.86-2.15). In the access site-related MVC group, only those with RBC transfusion ≥4 units had a significantly increased 3-year mortality risk (mortality, 51.8%; HR, 2.18; 95% CI: 1.19-3.89). Conclusions: In patients undergoing TF-TAVR, MVC was associated with an increased 3-year mortality risk, incrementally correlating with anatomical site and bleeding severity.

16.
JACC Basic Transl Sci ; 4(1): 83-94, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30847422

RESUMO

Myocardial infarction (MI)-induced cardiac fibrosis attenuates cardiac contractile function, and predisposes to arrhythmias and sudden cardiac death. Expression of connective tissue growth factor (CTGF) is elevated in affected organs in virtually every fibrotic disorder and in the diseased human myocardium. Mice were subjected to treatment with a CTGF monoclonal antibody (mAb) during infarct repair, post-MI left ventricular (LV) remodeling, or acute ischemia-reperfusion injury. CTGF mAb therapy during infarct repair improved survival and reduced LV dysfunction, and reduced post-MI LV hypertrophy and fibrosis. Mechanistically, CTGF mAb therapy induced expression of cardiac developmental and/or repair genes and attenuated expression of inflammatory and/or fibrotic genes.

17.
Int J Cardiol ; 263: 29-31, 2018 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-29681408

RESUMO

BACKGROUND: The MANTA system is a novel vascular closure device (VCD) and its safety and efficacy were compared to the ProGlide VCD in patients undergoing transfemoral transcatheter aortic valve implantation (TAVI). METHODS: This is a retrospective study including 222 patients who underwent transfemoral TAVI at three Finnish University Hospitals. The MANTA VCD was used in 107 patients and their outcome was compared with that of 115 patients in whom the arterial access was closed with the ProGlide VCD. RESULTS: VARC-2 VCD failure occurred less frequently in the MANTA cohort (3.7% vs. 7.8%, p = 0.378), but the difference did not reach statistical significance. When adjusted for the introducer outer diameter, the MANTA cohort had similar rates of VARC-2 major vascular complications (9.3% vs. 12.2%, adjusted: p = 0.456), VARC-2 life-threatening/disabling bleeding (9.3% vs. 6.1%, adjusted: p = 0.296) and need of invasive treatment of bleeding (4.7% vs. 7.0%, adjusted: p = 0.416) compared to the ProGlide cohort. Additional VCDs were more frequently needed in the ProGlide cohort (58.3% vs. 1.9%, p < 0.0001). CONCLUSIONS: In patients undergoing transfemoral TAVI, the MANTA VCD showed a similar risk of VARC-2 vascular and bleeding complications compared to the ProGlide VCD, but it reduced significantly the need of additional VCDs for completion of hemostasis.


Assuntos
Perda Sanguínea Cirúrgica/prevenção & controle , Artéria Femoral/cirurgia , Complicações Intraoperatórias/diagnóstico , Complicações Intraoperatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/normas , Dispositivos de Oclusão Vascular/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Finlândia/epidemiologia , Humanos , Masculino , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Dispositivos de Oclusão Vascular/efeitos adversos
18.
Duodecim ; 131(5): 441-7, 2015.
Artigo em Finlandês | MEDLINE | ID: mdl-26237906

RESUMO

With the development of new protein kinases, antibodies, immunomodulators and hormonal treatments, significant progress has taken place in the last few years in the pharmacological treatment of cancers. At the same time, old cytotoxic drugs still remain in use. In regard to the heart, anthracyclines are the most problematic cytotoxic drugs, as they may cause cardiac insufficiency that is manifested only years after the treatment. Also trastuzumab and kinase inhibitors may cause cardiac insufficiency. Fluoropyrimidines cause myocardial ischemia for some patients. Treatments targeting VEGF inhibition are frequently associated with significant elevation of blood pressure.


Assuntos
Antineoplásicos/efeitos adversos , Cardiopatias/induzido quimicamente , Coração/efeitos dos fármacos , Neoplasias/tratamento farmacológico , Antraciclinas/efeitos adversos , Anticorpos Monoclonais Humanizados/efeitos adversos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Fluoruracila/efeitos adversos , Humanos , Inibidores de Proteínas Quinases/efeitos adversos , Fatores de Risco , Trastuzumab , Fator A de Crescimento do Endotélio Vascular/antagonistas & inibidores
19.
Hypertension ; 63(6): 1235-40, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24688123

RESUMO

Connective tissue growth factor (CTGF) is involved in the pathogenesis of various fibrotic disorders. However, its role in the heart is not clear. To investigate the role of CTGF in regulating the development of cardiac fibrosis and heart failure, we subjected mice to thoracic aortic constriction (TAC) or angiotensin II infusion, and antagonized the function of CTGF with CTGF monoclonal antibody (mAb). After 8 weeks of TAC, mice treated with CTGF mAb had significantly better preserved left ventricular (LV) systolic function and reduced LV dilatation compared with mice treated with control immunoglobulin G. CTGF mAb-treated mice exhibited significantly smaller cardiomyocyte cross-sectional area and reduced expression of hypertrophic marker genes. CTGF mAb treatment reduced the TAC-induced production of collagen 1 but did not significantly attenuate TAC-induced accumulation of interstitial fibrosis. Analysis of genes regulating extracellular matrix proteolysis showed decreased expression of plasminogen activator inhibitor-1 and matrix metalloproteinase-2 in mice treated with CTGF mAb. In contrast to TAC, antagonizing the function of CTGF had no effect on LV dysfunction or LV hypertrophy in mice subjected to 4-week angiotensin II infusion. Further analysis showed that angiotensin II-induced expression of hypertrophic marker genes or collagens was not affected by treatment with CTGF mAb. In conclusion, CTGF mAb protects from adverse LV remodeling and LV dysfunction in hearts subjected to pressure overload by TAC. Antagonizing the function of CTGF may offer protection from cardiac end-organ damage in patients with hypertension.


Assuntos
Anticorpos Monoclonais/farmacologia , Fator de Crescimento do Tecido Conjuntivo/antagonistas & inibidores , Insuficiência Cardíaca/complicações , Disfunção Ventricular Esquerda/prevenção & controle , Remodelação Ventricular/efeitos dos fármacos , Angiotensina II/farmacologia , Animais , Anticorpos Monoclonais/imunologia , Aorta Torácica/efeitos dos fármacos , Aorta Torácica/metabolismo , Aorta Torácica/patologia , Colágeno Tipo I/genética , Fator de Crescimento do Tecido Conjuntivo/genética , Fator de Crescimento do Tecido Conjuntivo/imunologia , Constrição Patológica/fisiopatologia , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Expressão Gênica/efeitos dos fármacos , Coração/efeitos dos fármacos , Coração/fisiopatologia , Insuficiência Cardíaca/fisiopatologia , Masculino , Metaloproteinase 2 da Matriz/genética , Metaloproteinase 2 da Matriz/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Miocárdio/metabolismo , Miocárdio/patologia , Miócitos Cardíacos/efeitos dos fármacos , Miócitos Cardíacos/metabolismo , Inibidor 1 de Ativador de Plasminogênio/genética , Pressão , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Disfunção Ventricular Esquerda/etiologia , Suporte de Carga/fisiologia
20.
J Biol Chem ; 287(7): 4572-80, 2012 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-22170057

RESUMO

Neuronostatin, a recently discovered peptide encoded by somatostatin gene, is involved in regulation of neuronal function, blood pressure, food intake, and drinking behavior. However, the biological effects of neuronostatin on cardiac myocytes are not known, and the intracellular signaling mechanisms induced by neuronostatin remain unidentified. We analyzed the effect of neuronostatin in isolated perfused rat hearts and in cultured primary cardiomyocytes. Neuronostatin infusion alone had no effect on left ventricular (LV) contractile function or on isoprenaline- or preload-induced increase in cardiac contractility. However, infusion of neuronostatin significantly decreased the positive inotropic response to endothelin-1 (ET-1). This was associated with an increase in phosphorylation of p38 mitogen-activated protein kinase and c-Jun N-terminal kinase (JNK). Treatment of both neonatal and adult cardiomyocytes with neuronostatin resulted in reduced cardiomyocyte viability. Inhibition of JNK further increased the neuronostatin-induced cell death. We conclude that neuronostatin regulates cardiac contractile function and cardiomyocyte survival. Receptors for neuronostatin need to be identified to further characterize the biological functions of the peptide.


Assuntos
Contração Miocárdica/fisiologia , Miócitos Cardíacos/metabolismo , Fragmentos de Peptídeos/metabolismo , Somatostatina/metabolismo , Animais , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/fisiologia , Células Cultivadas , Endotelina-1/metabolismo , Ventrículos do Coração/citologia , Ventrículos do Coração/metabolismo , MAP Quinase Quinase 4/metabolismo , Masculino , Miócitos Cardíacos/citologia , Fragmentos de Peptídeos/farmacologia , Ratos , Ratos Sprague-Dawley , Somatostatina/farmacologia , Proteínas Quinases p38 Ativadas por Mitógeno/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA