1.
Nucl Med Commun ; 44(6): 427-433, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37038959

RESUMO

OBJECTIVE: iRENEX is a software module that incorporates scintigraphic and clinical data to interpret 99m Tc- mercaptoacetyltriglycine (MAG3) diuretic studies and provide reasons for their conclusions. Our objectives were to compare iRENEX interpretations with those of expert physicians, use iRENEX to evaluate resident performance and determine if iRENEX could improve the diagnostic accuracy of experienced residents. METHODS: Baseline and furosemide 99m Tc-MAG3 acquisitions of 50 patients with suspected obstruction (mean age ± SD, 58.7 ±â€…15.8 years, 60% female) were randomly selected from an archived database and independently interpreted by iRENEX, three expert readers and four nuclear medicine residents with one full year of residency. All raters had access to scintigraphic data and a text file containing clinical information and scored each kidney on a scale from +1.0 to -1.0. Scores ≥0.20 represented obstruction with higher scores indicating greater confidence. Scores +0.19 to -0.19 were indeterminate; scores ≤-0.20 indicated no obstruction. Several months later, residents reinterpreted the studies with access to iRENEX. Receiver operating characteristic (ROC) analysis and concordance correlation coefficient (CCC) quantified agreement. RESULTS: The CCC among experts was higher than that among residents, 0.84, versus 0.39, respectively, P  < 0.001. When residents reinterpreted the studies with iRENEX, their CCC improved from 0.39 to 0.73, P  < 0.001. ROC analysis showed significant improvement in the ability of residents to distinguish between obstructed and non-obstructed kidneys using iRENEX ( P  = 0.036). CONCLUSION: iRENEX interpretations were comparable to those of experts. iRENEX reduced interobserver variability among experienced residents and led to better agreement between resident and expert interpretations.


Assuntos
Diuréticos , Tecnécio Tc 99m Mertiatida , Humanos , Feminino , Masculino , Renografia por Radioisótopo , Cintilografia , Computadores , Compostos Radiofarmacêuticos
2.
AJR Am J Roentgenol ; 205(5): W519-31, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26496574

RESUMO

OBJECTIVE: This image-based article illustrates the anatomic regions of squamous cell carcinomas of the head and neck and describes the metastatic pathways in and TNM staging for each region. Both the role and limitations of FDG PET/CT in imaging such cancers are discussed, and cases exemplifying these issues are reported. Also included is a discussion of the use of FDG PET/CT to monitor the response of squamous cell carcinomas of the head and neck to therapy, in addition to a brief comparison of PET/CT with such traditional imaging modalities as CT, MRI, and ultrasound. CONCLUSION: Understanding the characteristics of squamous cell carcinoma of the head and neck, as imaged by FDG PET/CT, is crucial for determining treatment strategy, because it helps to avoid incorrect staging and also provides an accurate assessment of treatment response.


Assuntos
Carcinoma de Células Escamosas/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Imagem Multimodal , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/terapia , Fluordesoxiglucose F18 , Neoplasias de Cabeça e Pescoço/patologia , Neoplasias de Cabeça e Pescoço/terapia , Humanos , Estadiamento de Neoplasias , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X
3.
Clin Orthop Relat Res ; (410): 90-100, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12771820

RESUMO

The forces and torques that occur during walking gait, particularly during toe-off, promote articulation in the posteromedial quadrant of tibial inserts. Retrieved components of failed knee arthroplasties show ultrahigh molecular weight polyethylene damage patterns in this region. Component-designed constraint, compromised polymer, and surgical factors account for these observations. The current authors compare the contact stresses that developed on four implant designs during toe-off for optimally aligned and externally torqued components using the finite element method. Under 16 N-m of torque, the four designs studied varied regarding their centers of rotation and magnitude of external rotation, which are related directly to their specific articulating surface geometry. Designs with conforming condylar geometry had greater rotational constraint and therefore, less external rotation. These conforming designs offer the benefits of lower stresses and tend to limit contact near the edge of the plateau. However, because of their increased rotational constraint, torque is transmitted more readily to the implant-bone interface, increasing the potential for implant loosening. The data presented serve as an indicator of the potential for polyethylene tibial component surface damage and define the role that implant geometry plays in resisting external rotation.


Assuntos
Análise de Elementos Finitos , Prótese do Joelho , Caminhada/fisiologia , Marcha/fisiologia , Humanos , Polietileno , Desenho de Prótese , Falha de Prótese , Rotação , Estresse Mecânico , Torque