Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.024
Filtrar
2.
Diagnosis (Berl) ; 2024 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-39295160

RESUMO

Over the last decades, in addition to the improvement of pathophysiological knowledge regarding the role and mechanisms of action of vitamin D, there has been a progressive advancement in analytical technologies for its measurement, as well as in methodological standardization. A significant number of scientific works, meta-analyses, and guidelines have been published on the importance of vitamin D and the need for supplementation in deficient individuals. However, it appears necessary to clarify the fundamental elements related to the measurement of vitamin D (both at the strictly analytical and post-analytical levels) and the scientific evidence related to the efficacy/safety of supplementation. In particular, there is a need to discuss current recommended levels for deficiency, insufficiency and possible toxicity in the light of evidence from standardization projects. Additionally, given the important interrelations between vitamin D, parathyroid hormone (PTH), and fibroblast growth factor-23 (FGF23), the analytical issues and clinical utility of these biomarkers will be discussed.

3.
Clin Chem Lab Med ; 2024 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-39259894

RESUMO

The ultimate goal of value-based laboratory medicine is maximizing the effectiveness of laboratory tests in improving patient outcomes, optimizing resources and minimizing unnecessary costs. This approach abandons the oversimplified notion of test volume and cost, in favor of emphasizing the clinical utility and quality of diagnostic tests in the clinical decision-making. Several key elements characterize value-based laboratory medicine, which can be summarized in some basic concepts, such as organization of in vitro diagnostics (including appropriateness, integrated diagnostics, networking, remote patient monitoring, disruptive innovations), translation of laboratory data into clinical information and measurable outcomes, sustainability, reimbursement, ethics (e.g., patient empowerment and safety, data protection, analysis of big data, scientific publishing). Education and training are also crucial, along with considerations for the future of the profession, which will be largely influenced by advances in automation, information technology, artificial intelligence, and regulations concerning in vitro diagnostics. This collective opinion paper, composed of summaries from presentations given at the two-day European Federation of Laboratory Medicine (EFLM) Strategic Conference "A vision to the future: value-based laboratory medicine" (Padova, Italy; September 23-24, 2024), aims to provide a comprehensive overview of value-based laboratory medicine, projecting the profession into a more clinically effective and sustainable future.

4.
Clin Chem Lab Med ; 2024 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-39141796

RESUMO

Direct-to-consumer testing (DTCT) refers to commercial laboratory tests initiated by laypersons without the involvement of healthcare professionals. As this market grows in size and variety of products, a clear definition of DTCT to ground the conceptualization of their harms and benefits is needed. We describe how three different modalities of DTCT (home self-testing, self-sampled tests, and direct access tests) present caveats to the traditional testing process ('brain-to-brain loop'), and how this might differ between medical vs. non-medical laboratories. We make recommendations for ways to improve quality and reduce errors with respect to DTCT. The potential benefits and harms of DTCT will invariably depend on the context and situation of individual consumers and the types of tests involved. Importantly, implications for both consumers and the healthcare system should be considered, such as the effects on improving health outcomes and reducing unnecessary testing and use of clinical resources. 'Consumer initiation' must be a central defining characteristic of DTCT, to clearly demarcate the key drawbacks as well as opportunities of this type of testing from a laboratory specialists' perspective. The concept of 'consumer initiated testing' should also help define DTCT regulation, and provide a locus of efforts to support consumers as the main decision-makers in the purchasing and conducting of these tests in the absence of clinician gatekeeping.

6.
Clin Chem Lab Med ; 2024 Jul 18.
Artigo em Inglês | MEDLINE | ID: mdl-39016272

RESUMO

The first part of this Inter-Society Document describes the mechanisms involved in the development of cardiovascular diseases, particularly arterial hypertension, in adults and the elderly. It will also examine how consistent physical exercise during adolescence and adulthood can help maintain blood pressure levels and prevent progression to symptomatic heart failure. The discussion will include experimental and clinical evidence on the use of specific exercise programs for preventing and controlling cardiovascular diseases in adults and the elderly. In the second part, the clinical relevance of cardiac-specific biomarkers in assessing cardiovascular risk in the general adult population will be examined, with a focus on individuals engaged in sports activities. This section will review recent studies that suggest a significant role of biomarkers in assessing cardiovascular risk, particularly the presence of cardiac damage, in athletes who participate in high-intensity sports. Finally, the document will discuss the potential of using cardiac-specific biomarkers to monitor the effectiveness of personalized physical activity programs (Adapted Physical Activity, APA). These programs are prescribed for specific situations, such as chronic diseases or physical disabilities, including cardiovascular diseases. The purposes of this Inter-Society Document are the following: 1) to discuss the close pathophysiological relationship between physical activity levels (ranging from sedentary behavior to competitive sports), age categories (from adolescence to elderly age), and the development of cardiovascular diseases; 2) to review in detail the experimental and clinical evidences supporting the role of cardiac biomarkers in identifying athletes and individuals of general population at higher cardiovascular risk; 3) to stimulate scientific societies and organizations to develop specific multicenter studies that may take into account the role of cardiac biomarkers in subjects who follow specific exercise programs in order to monitor their cardiovascular risk.

7.
Clin Chem Lab Med ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39008654

RESUMO

The healthcare systems are a prime target for cyber-attacks due to the sensitive nature of the information combined with the essential need for continuity of care. Medical laboratories are particularly vulnerable to cyber-attacks for a number of reasons, including the high level of information technology (IT), computerization and digitization. Based on reliable and widespread evidence that medical laboratories may be inadequately prepared for cyber-terrorism, a panel of experts of the Task Force Preparation of Labs for Emergencies (TF-PLE) of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) has recognized the need to provide some general guidance that could help medical laboratories to be less vulnerable and better prepared for the dramatic circumstance of a disruptive cyber-attack, issuing a number of consensus recommendations, which are summarized and described in this opinion paper.

8.
Clin Chem Lab Med ; 2024 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-39072502

RESUMO

Following the COVID-19 pandemic, the concepts of value-based medicine (VBM) and value-based laboratory medicine (VBLM) are receiving increasing interest to improve the quality, sustainability and safety of healthcare. Laboratory medicine is well positioned to support the transition to value-based healthcare as it helps to improve clinical outcomes and healthcare sustainability by reducing the time to diagnosis, improving diagnostic accuracy, providing effective guidance for tailored therapies and monitoring, and supporting screening and wellness care. However, the perception of the value of laboratory medicine is still limited, to the extent that it has been defined a "profession without a face", often lacking visibility to patients and the public. In addition, in recent decades, clinical laboratories have sought to improve the ration between outcomes and costs by increasing efficiency and reducing the cost per test rather than improving clinical outcomes. The aim of this paper is to propose a 10-point manifesto for implementing value-based laboratory medicine in clinical practice.

10.
11.
Clin Chem Lab Med ; 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38880779

RESUMO

Point-of-care testing (POCT) is becoming an increasingly popular way to perform laboratory tests closer to the patient. This option has several recognized advantages, such as accessibility, portability, speed, convenience, ease of use, ever-growing test panels, lower cumulative healthcare costs when used within appropriate clinical pathways, better patient empowerment and engagement, and reduction of certain pre-analytical errors, especially those related to specimen transportation. On the other hand, POCT also poses some limitations and risks, namely the risk of lower accuracy and reliability compared to traditional laboratory tests, quality control and connectivity issues, high dependence on operators (with varying levels of expertise or training), challenges related to patient data management, higher costs per individual test, regulatory and compliance issues such as the need for appropriate validation prior to clinical use (especially for rapid diagnostic tests; RDTs), as well as additional preanalytical sources of error that may remain undetected in this type of testing, which is usually based on whole blood samples (i.e., presence of interfering substances, clotting, hemolysis, etc.). There is no doubt that POCT is a breakthrough innovation in laboratory medicine, but the discussion on its appropriate use requires further debate and initiatives. This collective opinion paper, composed of abstracts of the lectures presented at the two-day expert meeting "Point-Of-Care-Testing: State of the Art and Perspective" (Venice, April 4-5, 2024), aims to provide a thoughtful overview of the state-of-the-art in POCT, its current applications, advantages and potential limitations, as well as some interesting reflections on the future perspectives of this particular field of laboratory medicine.

12.
Clin Chem Lab Med ; 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38726708

RESUMO

In recent years, the integration of technological advancements and digitalization into healthcare has brought about a remarkable transformation in care delivery and patient management. Among these advancements, the concept of digital twins (DTs) has recently gained attention as a tool with substantial transformative potential in different clinical contexts. DTs are virtual representations of a physical entity (e.g., a patient or an organ) or systems (e.g., hospital wards, including laboratories), continuously updated with real-time data to mirror its real-world counterpart. DTs can be utilized to monitor and customize health care by simulating an individual's health status based on information from wearables, medical devices, diagnostic tests, and electronic health records. In addition, DTs can be used to define personalized treatment plans. In this study, we focused on some possible applications of DTs in laboratory medicine when used with AI and synthetic data obtained by generative AI. The first point discussed how biological variation (BV) application could be tailored to individuals, considering population-derived BV data on laboratory parameters and circadian or ultradian variations. Another application could be enhancing the interpretation of tumor markers in advanced cancer therapy and treatments. Furthermore, DTs applications might derive personalized reference intervals, also considering BV data or they can be used to improve test results interpretation. DT's widespread adoption in healthcare is not imminent, but it is not far off. This technology will likely offer innovative and definitive solutions for dynamically evaluating treatments and more precise diagnoses for personalized medicine.

13.
Clin Chem Lab Med ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38711414

RESUMO

Point-of-care testing (POCT), near-patient testing (NPT) and patient self-tests (PST) are diagnostic examinations performed at the time and place of patient care. While POCT and NPT are performed and analyzed by medical professionals, PST are based on samples and parameters directly collected and analyzed by lay users. These tests are spreading both in high income countries and in low to middle income countries as they are expected to improve healthcare efficiency and equity, by saving resources, releasing pressure from hospitals and reducing logistical barriers. However, accurate multidisciplinary assessment is mandatory to ensure that what they promise is real. We reviewed some important ethical aspects, international standards and regulations. The current risks associated with alternative ways of testing are explained by the principles of respect for patient autonomy and non-maleficence. Further evidence from multidisciplinary assessment is needed to evaluate pros and cons in light of the principles of beneficence and justice. Although POCT or NPT need common regulation and accurate provider training to ensure safe and appropriate interpretation of results, PST needs even more attention as they are subject to direct patient use. Randomized controlled trails including patient education should be conducted in order to provide reliable evidence on clinical outcomes, patient acceptance and cost-effectiveness. Mandatory regulation is needed to avoid harm and EU regulation should help different countries maintain a safe use of devices in a global population of producers and users.

14.
Diagnosis (Berl) ; 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38756092

RESUMO

OBJECTIVES: Medical errors and complications pose a major threat to the safety of healthcare systems worldwide. This article was hence aimed at determining the current burden of complications of medical and surgical care in the US. METHODS: We searched the latest version of the US Centers for Disease Control and Prevention (CDC) WONDER online database (years 2018-2022) using ICD-10 codes Y40-Y84 (complications of medical and surgical care). RESULTS: The age-adjusted death rate for complications of medical and surgical care increased from 1.17 × 100,000 in 2018 to 1.49 × 100,000 in 2021, but then declined to 0.85 × 100,000 in 2022. The gender-specific analysis showed a similar trend, with the age-adjusted death rate values always being higher in men than in women. A clear age-dependent relationship was also found in the crude mortality rate for complications of medical and surgical care, as higher death rates were observed in older patients. CONCLUSIONS: This analysis reveals that the burden of complications of medical and surgical care has increased over time, especially during the COVID-19 pandemic, but has then considerably declined in 2022. However, root cause analysis and actions are still needed for preventing the still noticeable consequences of medical complications.

15.
J Clin Med ; 13(8)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38673517

RESUMO

Background: We compared the performance of 21 different assays performed by the Wantai Wan200+ (Wantai BioPharm, Beijing, China) with respect to other methods in use at the University Hospital of Padova (AOPD), Italy. Methods: The plasma (P) or serum (S) of 5027 leftover samples, collected from May to Sept 2023, was either analyzed or frozen at -20 °C. Beckman DXI800 (DXI), Roche Cobas 8000 e801 (RC), Snibe Maglumi 4000 plus (SM), DiaSorin Liaison XL (DL) and Binding Site Optilite (BS) equipment were used at the AOPD. P-procalcitonin (PCT), DXI; P-Troponin I (TnI), DXI; S-CA125, DXI; S-free PSA (f-PSA), DXI; S-total PSA (t-PSA), DXI; S-IL6, SM; P-Troponin T (TnT), RC; P-NT-proBNP, RC; P-Neuron-Specific Enolase (NSE), RC; S-CA15-3, DL; S-CA19-9, DL; S-AFP, DL; and S-CEA, DL were tested in fresh samples. P-Myoglobin (Myo), DXI; P-Cyfra21-1, RC; S-ß2 microglobulin (B2MIC), BS; S-HE4, SM; S-PGI, SM; S-PGII, SM; S-CA72-4, SM; and S-CA50, SM were analyzed in frozen and thawed samples. Bland-Altman (BA), Passing-Bablok (PB) and Cohen's Kappa (CKa) metrics were used as statistics. Results: An excellent comparability profile was found for 11 analytes. For example, the t-PSA CKa was 0.94 (95%CI: 0.90 to 0.98), and the PB slope and intercept were 1.02 (95%CI: 0.99 to 1.03) and 0.02 (95%CI: 0.01 to 0.03), respectively; the BA bias was 2.25 (95%CI: -0.43 to 4.93). Ten tested measurands demonstrated a suboptimal comparability profile. Biological variation in EFLM (EuBIVAS) performance specifications was evaluated to assess the clinical relevance of measured biases. Conclusions: Evaluation of the Wantai Wan200+'s performance suggests that between-method differences did not exceed the calculated bias. Metrological traceability may influence the comparisons obtained for some measurands.

16.
Clin Chem Lab Med ; 62(9): 1795-1803, 2024 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-38512121

RESUMO

The most widespread healthcare reimbursement models, including diagnostic laboratory services, are Fee-for-Service, Reference Pricing and Diagnosis-Related Groups. Within these models healthcare providers are remunerated for each specific service or procedure they operate. Healthcare payers are increasingly exploring alternative models, such as bundled payments or value-based reimbursement to encourage value of patient care rather than the simple amount of delivered services. These alternative models are advised, as they are more efficient in promoting cost-effective, high-quality laboratory testing, thereby improving patient health outcomes. If outcomes-based evaluation is a pillar in a new vision of "Value-Based Healthcare", an active policy of Value-Based Reimbursement in laboratory medicine will assure both an efficiency-based sustainability and a high-quality effectiveness-based diagnostic activity. This review aims to evaluate current and alternative reimbursement models, to support a wider agenda in encouraging more Value-Based Healthcare and Value-Based Reimbursement in laboratory medicine.


Assuntos
Mecanismo de Reembolso , Humanos , Atenção à Saúde/economia , Laboratórios Clínicos/economia
18.
Antibodies (Basel) ; 13(1)2024 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-38247570

RESUMO

Saliva is a promising matrix with several purposes. Our aim is to verify if salivary anti-SARS-CoV-2 antibody determination is suitable for monitoring immune responses. One hundred eighty-seven subjects were enrolled at University-Hospital Padova: 105 females (56.1%) and 82 males (43.9%), 95 (50.8%) children and 92 (49.2%) adults. Subjects self-collected saliva using Salivette; nineteen subjects collected three different samples within the day. A serum sample was obtained for all individuals. The N/S anti-SARS-CoV-2 salivary IgG (sal-IgG) and serum anti-SARS-CoV-2 S-RBD IgG (ser-IgG) were used for determining anti-SARS-CoV-2 antibodies. The mean (min-max) age was 9.0 (1-18) for children and 42.5 (20-61) for adults. Of 187 samples, 63 were negative for sal-IgG (33.7%), while 7 were negative for ser-IgG (3.7%). Spearman's correlation was 0.56 (p < 0.001). Sal-IgG and ser-IgG levels were correlated with age but not with gender, comorbidities, prolonged therapy, previous SARS-CoV-2 infection, or time from last COVID-19 infection/vaccination. The repeatability ranged from 23.8% (7.4 kAU/L) to 4.0% (3.77 kAU/L). The linearity of the assay was missed in 4/6 samples. No significant intrasubject differences were observed in sal-IgG across samples collected at different time points. Sal-IgG has good agreement with ser-IgG. Noninvasive saliva collection represents an alternative method for antibody measurement, especially in children.

19.
Clin Chem Lab Med ; 62(6): 1126-1132, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38295343

RESUMO

OBJECTIVES: Tubular maximum phosphate reabsorption per glomerular filtration rate (TmP/GFR) is used to evaluate renal phosphate reabsorption and it is a useful tool for the differential diagnosis of hypophosphatemic syndromes. TmP/GFR is typically calculated from fasting plasma and second morning void urine samples, obtained 2 h after the first void (TmP/GFR 2 h). The purpose of this study was to evaluate if TmP/GFR calculated from 24 h urine collection (TmP/GFR 24 h) can be used as an alternative for TmP/GFR 2 h in patients with urine phosphate wasting. METHODS: We enrolled adult patients with X-linked hypophosphatemia (XLH) or tumor-induced osteomalacia (TIO). All patients underwent blood and urine sample collections, to calculate TmP/GFR 24 h and TmP/GFR 2 h. RESULTS: Twenty patients (17 XLH and 3 TIO), aged 24-78 years, were included. All patients had low TmP/GFR 2 h (0.35 mmol/L, IQR 0.24-0.47 mmol/L) and TmP/GFR 24 h (0.31 mmol/L, IQR 0.22-0.43 mmol/L). The concordance correlation coefficient between TmP/GFR 2 h and TmP/GFR 24 h was 0.86 (95 % CI: 0.69-0.93), with a systematic bias of 0.05 mmol/L (95 % limits of agreement: -0.10 to 0.20). Furthermore, in 70 % (i.e., 14 patients out of 20) and 80 % (i.e., 16 patients out of 20) of cases the difference between TmP/GFR 2 h and TmP/GFR 24 h was within ±30 % and ±35 %, respectively. CONCLUSIONS: Despite TmP/GFR 2 and 24 h show a relatively suboptimal agreement, the difference between the two parameters appears to be small and not clinically significant in the setting of adult patients with FGF23-dependent urine phosphate wasting and secondary hypophosphatemia.


Assuntos
Fator de Crescimento de Fibroblastos 23 , Osteomalacia , Fosfatos , Coleta de Urina , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem , Raquitismo Hipofosfatêmico Familiar/urina , Raquitismo Hipofosfatêmico Familiar/diagnóstico , Taxa de Filtração Glomerular , Hipofosfatemia/urina , Hipofosfatemia/diagnóstico , Túbulos Renais/metabolismo , Osteomalacia/urina , Osteomalacia/diagnóstico , Síndromes Paraneoplásicas/urina , Síndromes Paraneoplásicas/diagnóstico , Fosfatos/urina , Coleta de Urina/métodos
20.
Clin Chem Lab Med ; 62(6): 1053-1062, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38176022

RESUMO

The final, post-analytical, phase of laboratory testing is increasingly recognized as a fundamental step in maximizing quality and effectiveness of laboratory information. There is a need to close the loop of the total testing cycle by improving upon the laboratory report, and its notification to users. The harmonization of the post-analytical phase is somewhat complicated, mainly because it calls for communication that involves parties speaking different languages, including laboratorians, physicians, information technology specialists, and patients. Recently, increasing interest has been expressed in integrated diagnostics, defined as convergence of imaging, pathology, and laboratory tests with advanced information technology (IT). In particular, a common laboratory, radiology and pathology diagnostic reporting system that integrates text, sentinel images and molecular diagnostic data to an integrated, coherent interpretation enhances management decisions and improves quality of care.


Assuntos
Sistemas de Informação em Laboratório Clínico , Humanos , Técnicas de Laboratório Clínico/normas , Laboratórios Clínicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA