Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 131
Filtrar
1.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38248894

RESUMO

Cardiac resynchronization therapy (CRT) is a recognized therapy for heart failure with altered ejection fraction and abnormal left ventricular activation time. Since the introduction of the therapy, a 30% rate of non-responders is observed and unchanged. The 12-lead ECG remains the only recommended tool for patient selection to CRT. The 12-lead ECG is, however, limited in its inability to provide a precise pattern of regional electrical activity. Electrocardiographic imaging (ECGi) provides a non-invasive detailed mapping of cardiac activation and therefore appears as a promising tool for CRT candidates. The non-invasive ventricular activation maps acquired by ECGi have been primarily explored for the diagnosis and guidance of therapy in patients with atrial or ventricular tachyarrhythmia. However, the accuracy of the system in this field is lacking and needs further improvement before considering a clinical application. On the other hand, its use for patient selection for CRT is encouraging. In this review, we introduce the technical considerations and we describe how ECGi can precisely characterize ventricular activation, especially in patients with left bundle branch block, thus identifying the electrical substrate responsive to CRT.

2.
Sensors (Basel) ; 24(2)2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38257619

RESUMO

Unlimited access to ECGs using an over-the-counter smartwatch constitutes a real revolution for our discipline, and the application is rapidly expanding to include patients with cardiac implantable electronic devices (CIEDs) such as pacemakers (PMs) and implantable cardioverter defibrillators (ICDs). CIEDs require periodic evaluation and adjustment by healthcare professionals. In addition, implanted patients often present with symptoms that may be related to their PMs or ICDs. An ECG smartwatch could reveal information about device functioning, confirm normal device function, or aid in the case of device troubleshooting. In this review, we delve into the available evidence surrounding smartwatches with ECG registration and their integration into the care of patients with implanted pacemakers and ICDs. We explore safety considerations and the benefits and limitations associated with these wearables, drawing on relevant studies and case series from our own experience. By analyzing the current landscape of this emerging technology, we aim to provide a comprehensive overview that facilitates informed decision-making for both healthcare professionals and patients.


Assuntos
Desfibriladores Implantáveis , Eletrocardiografia , Humanos , Coração , Eletricidade , Eletrônica
3.
Trends Cardiovasc Med ; 34(3): 174-180, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36603673

RESUMO

The adoption of wearables in medicine has expanded worldwide with a rapidly growing number of consumers and new features capable of real-time monitoring of health parameters such as the ability to record and transmit a single-lead electrocardiogram (ECG). Smartwatch ECGs are increasingly used but current smartwatches only screen for atrial fibrillation (AF). Most of the literature has focused on analyzing the smartwatch ECG accuracy for the detection of AF or other tachycardias. As with the conventional ECG, this tool may be used for many more purposes than only detection of AF. The objectives of this review are to describe the published literature regarding the accuracy and clinical value of recording a smartwatch ECG in other situations than diagnosis of tachycardia and discuss possible techniques to optimize the diagnostic yield.

4.
Sensors (Basel) ; 23(22)2023 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-38005669

RESUMO

Smartwatches equipped with automatic atrial fibrillation (AF) detection through electrocardiogram (ECG) recording are increasingly prevalent. We have recently reported the limitations of the Apple Watch (AW) in correctly diagnosing AF. In this study, we aim to apply a data science approach to a large dataset of smartwatch ECGs in order to deliver an improved algorithm. We included 723 patients (579 patients for algorithm development and 144 patients for validation) who underwent ECG recording with an AW and a 12-lead ECG (21% had AF and 24% had no ECG abnormalities). Similar to the existing algorithm, we first screened for AF by detecting irregularities in ventricular intervals. However, as opposed to the existing algorithm, we included all ECGs (not applying quality or heart rate exclusion criteria) but we excluded ECGs in which we identified regular patterns within the irregular rhythms by screening for interval clusters. This "irregularly irregular" approach resulted in a significant improvement in accuracy compared to the existing AW algorithm (sensitivity of 90% versus 83%, specificity of 92% versus 79%, p < 0.01). Identifying regularity within irregular rhythms is an accurate yet inclusive method to detect AF using a smartwatch ECG.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Eletrocardiografia/métodos , Frequência Cardíaca , Algoritmos
5.
J Cardiovasc Dev Dis ; 10(10)2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37887877

RESUMO

BACKGROUND: Implantable cardioverter-defibrillators (ICDs) need to reliably detect ventricular tachycardia (VT) and ventricular fibrillation (VF) while avoiding T-wave oversensing (TWOS), which is associated with a risk of inappropriate therapies. The incidence of TWOS with endovascular ICDs appears to differ between manufacturers. OBJECTIVES: We aimed to evaluate the incidence and clinical consequences of TWOS with contemporary Medtronic and Boston Scientific ICDs. METHODS: Consecutive patients implanted with a recent Medtronic or Boston Scientific ICD and remotely monitored at three French centers were included. All transmitted EGMs labelled as VF, VT, non-sustained VT (NSVT), or ventricular oversensing (Medtronic) were screened for TWOS. RESULTS: Among 7589 transmitted episodes from 674 patients with a Boston Scientific ICD, we did not identify a single case of TWOS. Among 16,790 transmitted episodes from 1733 patients with a Medtronic ICD, we identified 60 patients (3.4%) with at least one episode of TWOS. In 46 patients, TWOS was intermittent (NSVT episodes). In the remaining 14 patients, TWOS resulted in 60 sustained episodes (completed counters). No inappropriate therapies were delivered in 12 of these patients because no therapies were programmed (in monitor zones, 11 episodes) or because therapies were inhibited by the morphology discriminator (Wavelet, 19 episodes) or by the anti-TWOS algorithm (26 episodes). Two patients received inappropriate therapies due to TWOS (0.1% of patients with Medtronic ICDs). CONCLUSION: On review of 24,379 transmitted episodes from 2407 patients with endovascular ICDs, we found no case of TWOS with Boston Scientific devices, whereas TWOS was not uncommon with Medtronic devices. However, the risk of inappropriate therapy with Medtronic ICDs was very low (0.1%) due to the often intermittent nature of this phenomenon, the morphology discriminator, and the anti-TWOS algorithm.

6.
ESC Heart Fail ; 10(6): 3637-3645, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37797957

RESUMO

AIMS: From a patient and health system perspective, managing worsening heart failure (WHF) as an outpatient has become a priority. Remote management allows early detection of WHF, enabling timely intervention with the aim of preventing hospitalization. The objective of the study was to evaluate the feasibility and safety of remotely managing WHF events using a multiparametric platform. METHODS AND RESULTS: All patients enrolled in the heart failure remote management programme of the Bordeaux University Hospital Telemedicine Center between 1 January and 31 December 2021 were included in the study. Follow-up data were collected until 1 March 2022. Inclusion criteria were chronic heart failure (HF) with New York Heart Association ≥II symptoms and an elevated B-type natriuretic peptide (BNP > 100 pg/mL or N-terminal-pro-BNP > 1000 pg/mL). Patient assessments were performed remotely and included measurements of body weight, blood pressure, heart rate, symptoms, biochemical parameters, and data from cardiac implantable electronic devices when available. In total, 161 patients (71 ± 11 years old, 79% male) were followed for a mean of 291 ± 66 days with a mean adherence to the remote monitoring system of 80 ± 20%. Over this period, 52 (32.3%) patients had 105 WHF events, of which 66 (63%) were successfully managed remotely, the remaining requiring hospitalization. Freedom from WHF events and hospitalization at 300 days were 66% and 85%, respectively (P < 0.001 for the difference). Increased level of BNP was associated with an increased risk of WHF event [hazard ratio (HR) per unit increase in BNP: 1.001; 95% confidence interval (CI) 1-1.002; P = 0.001] and hospitalization (HR 1.002; 95% CI 1.002-1.003; P = 0.002). A decrease in the level of glomerular filtration rate was associated with an increased risk of hospitalization (HR per unit decrease in estimated glomerular filtration rate: 0.946; 95% CI 0.906-0.989; P = 0.014). WHF event recurrence and (re)hospitalization rates at 1-month were similar among patients managed remotely (18% and 12%, respectively) and those requiring hospitalization (21% and 10%, respectively). Iatrogenic complications occurred more often during hospitalization than remote management (26% vs. 3%, P < 0.001). CONCLUSIONS: Our study suggests that remote management of WHF events based on a multiparametric approach led by a telemedical centre is feasible and safe. Adopting such a strategy for patients with chronic HF could reduce HF-related hospitalizations with expected benefits for patients, care providers, and health care systems.


Assuntos
Insuficiência Cardíaca , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Insuficiência Cardíaca/diagnóstico , Vasodilatadores/uso terapêutico , Doença Crônica
7.
Heart Rhythm ; 20(10): 1378-1384, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37406873

RESUMO

BACKGROUND: Pacemakers (PMs) and implantable cardioverter-defibrillators (ICDs) increasingly automatically record and remotely transmit nonsustained ventricular tachycardia (NSVT) episodes, which may reveal ventricular oversensing. OBJECTIVES: We aimed to develop and validate a machine learning algorithm that accurately classifies NSVT episodes transmitted by PMs and ICDs in order to lighten health care workload burden and improve patient safety. METHODS: PMs or ICDs (Boston Scientific, St Paul, MN) from 4 French hospitals with ≥1 transmitted NSVT episode were split into 3 subgroups: training set, validation set, and test set. Each NSVT episode was labeled as either physiological or nonphysiological. Four machine learning algorithms-2DTF-CNN, 2D-DenseNet, 2DTF-VGG, and 1D-AgResNet-were developed using training and validation data sets. Accuracies of the classifiers were compared with an analysis of the remote monitoring team of the Bordeaux University Hospital using F2 scores (favoring sensitivity over predictive positive value) using an independent test set. RESULTS: A total of 807 devices transmitted 10,471 NSVT recordings (82% ICD; 18% PM), of which 87 devices (10.8%) transmitted 544 NSVT recordings with nonphysiological signals. The classification by the remote monitoring team resulted in an F2 score of 0.932 (sensitivity 95%; specificity 99%) The 4 machine learning algorithms showed high and comparable F2 scores (2DTF-CNN: 0.914; 2D-DenseNet: 0.906; 2DTF-VGG: 0.863; 1D-AgResNet: 0.791), and only 1D-AgResNet had significantly different labeling from that of the remote monitoring team. CONCLUSION: Machine learning algorithms were accurate in detecting nonphysiological signals within electrograms transmitted by PMs and ICDs. An artificial intelligence approach may render remote monitoring less resourceful and improve patient safety.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Taquicardia Ventricular , Humanos , Inteligência Artificial , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Aprendizado de Máquina
8.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37038759

RESUMO

AIMS: To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS: In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION: A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Anticoagulantes
9.
Front Cardiovasc Med ; 10: 1148052, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37025684

RESUMO

Background: Fat layers in obese patients can impair R-wave detection and diagnostic performance of a subcutaneous insertable cardiac monitor (ICM). We compared safety and ICM sensing quality between obese patients [body mass index (BMI) ≥ 30 kg/m2] and normal-weight controls (BMI <30 kg/m2) in terms of R-wave amplitude and time in noise mode (noise burden) detected by a long-sensing-vector ICM. Materials and methods: Patients from two multicentre, non-randomized clinical registries are included in the present analysis on January 31, 2022 (data freeze), if the follow-up period was at least 90 days after ICM insertion, including daily remote monitoring. The R-wave amplitudes and daily noise burden averaged intraindividually for days 61-90 and days 1-90, respectively, were compared between obese patients (n = 104) and unmatched (n = 268) and a nearest-neighbour propensity score (PS) matched (n = 69) normal-weight controls. Results: The average R-wave amplitude was significantly lower in obese (median 0.46 mV) than in normal-weight unmatched (0.70 mV, P < 0.0001) or PS-matched (0.60 mV, P = 0.003) patients. The median noise burden was 1.0% in obese patients, which was not significantly higher than in unmatched (0.7%; P = 0.056) or PS-matched (0.8%; P = 0.133) controls. The rate of adverse device effects during the first 90 days did not differ significantly between groups. Conclusion: Although increased BMI was associated with reduced signal amplitude, also in obese patients the median R-wave amplitude was >0.3 mV, a value which is generally accepted as the minimum level for adequate R-wave detection. The noise burden and adverse event rates did not differ significantly between obese and normal-weight patients.Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04075084 and NCT04198220.

10.
Sensors (Basel) ; 23(5)2023 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-36904759

RESUMO

Smartwatches that support the recording of a single-lead electrocardiogram (ECG) are increasingly being used beyond the wrist, by placement on the ankle and on the chest. However, the reliability of frontal and precordial ECGs other than lead I is unknown. This clinical validation study assessed the reliability of an Apple Watch (AW) to obtain conventional frontal and precordial leads as compared to standard 12-lead ECGs in both subjects without known cardiac anomalies and patients with underlying heart disease. In 200 subjects (67% with ECG anomalies), a standard 12-lead ECG was performed, followed by AW recordings of the standard Einthoven leads (leads I, II, and III) and precordial leads V1, V3, and V6. Seven parameters (P, QRS, ST, and T-wave amplitudes, PR, QRS, and QT intervals) were compared through a Bland-Altman analysis, including the bias, absolute offset, and 95% limits of agreement. AW-ECGs recorded on the wrist but also beyond the wrist had similar durations and amplitudes compared to standard 12-lead ECGs. Significantly greater amplitudes were measured by the AW for R-waves in precordial leads V1, V3, and V6 (+0.094 mV, +0.149 mV, +0.129 mV, respectively, all p < 0.001), indicating a positive bias for the AW. AW can be used to record frontal, and precordial ECG leads, paving the way for broader clinical applications.


Assuntos
Eletrocardiografia , Cardiopatias , Humanos , Reprodutibilidade dos Testes , Arritmias Cardíacas , Tórax
11.
Heart Rhythm ; 20(5): 699-706, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36646235

RESUMO

BACKGROUND: New-onset left bundle branch block (LBBB) is one of the most frequent complications after transcatheter aortic valve implantation (TAVI) and is associated with delayed high degree atrioventricular (AV) block. OBJECTIVES: The objectives of this study were to determine the incidence of AV block in such a population and to assess the performance and safety of a risk stratification algorithm on the basis of electrophysiology study (EPS) followed by implantation of a pacemaker or implantable loop recorder (ILR). METHODS: This was a prospective open-label study with 12-month follow-up. From June 8, 2015, to November 8, 2018, 183 TAVI recipients (mean age 82.3 ± 5.9 years) were included at 10 centers. New-onset LBBB after TAVI persisting for >24 hours was assessed by electrophysiology study during initial hospitalization. High-risk patients (His-ventricle interval ≥70 ms) were implanted with a dual-chamber pacemaker recording AV conduction disturbance episodes. Patients at lower risk were implanted with an ILR with automatic remote monitoring. RESULTS: A high-grade AV conduction disorder was identified in 56 patients (30.6%) at 12 months. Four subjects were symptomatic, all in the ILR group. No complications were associated with the stratification procedure. Patients with His-ventricle interval ≥70 ms displayed more high-grade AV conduction disorders (53.2% [25 of 47] vs 22.8% [31 of 136]; P < .001). In a multivariate analysis, His-ventricle interval ≥70 ms was independently associated with the occurrence of a high-grade conduction disorder (subdistribution hazard ratio 2.4; 95% confidence interval 1.2-4.8; P = .010). CONCLUSION: New-onset LBBB after TAVI was associated with high rates of high-grade AV conduction disturbances. The stratification algorithm provided safe and valuable aid to management decisions and reliable guidance on pacemaker implantation.


Assuntos
Estenose da Valva Aórtica , Bloqueio Atrioventricular , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Idoso , Idoso de 80 Anos ou mais , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Incidência , Estudos Prospectivos , Eletrocardiografia , Doença do Sistema de Condução Cardíaco/diagnóstico , Doença do Sistema de Condução Cardíaco/epidemiologia , Doença do Sistema de Condução Cardíaco/terapia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/epidemiologia , Bloqueio Atrioventricular/etiologia , Marca-Passo Artificial/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento
12.
Artigo em Inglês | MEDLINE | ID: mdl-36652082

RESUMO

BACKGROUND: The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data. METHODS: Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less. RESULTS: Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months. CONCLUSIONS: The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT04767516 .

13.
J Cardiovasc Electrophysiol ; 34(2): 412-417, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36583963

RESUMO

AIMS: Leadless pacing has emerged as an alternative to conventional transvenous pacemakers to mitigate the risks of pocket- and lead-related complications but its use remains controversial in young adults mostly because experience in this patient population is limited. We sought to examine the feasibility and safety of implanting leadless single chamber pacemakers in young adults. METHODS: This multicenter, retrospective, observational study sought to evaluate the safety, efficacy, and electrical performance of the Micra VR Transcatheter Pacemaker System (Medtronic) in patients between 18 and 40 years who underwent implantation of a leadless pacemaker for any indication at the university medical centers of Bordeaux, Clermont-Ferrand, Toulouse, and Tours (France), between 2015 and 2021. The primary safety endpoint was freedom from system-related or procedure-related major complications at 6 months. The primary efficacy endpoint was the combination of a low (≤2 V) and stable (increase within 1.5 V) pacing capture threshold at 6 months. RESULTS: Leadless pacemaker implantation was successful in all 35 patients. At 6 months, safety endpoint was met for 35 (100%) and efficacy endpoint for 34 (97%) patients. During a follow-up of 26 ± 15 months (range: 6-60 months), Safety endpoint remained 100% and efficacy endpoint was 94%. Leadless pacemaker retrieval was not required in any patient. Approximately one-third of patients (n = 13, 37%) had >40% ventricular pacing burdens at 1 year, including all 10 patients with a complete AV block but also 3 patients with normal AV conduction during implantation. One patient reported symptoms of pacemaker syndrome which was confirmed using Holter recording and successfully treated using reprogramming. CONCLUSION: In this observational study, leadless pacemakers demonstrated favorable short- and intermediate-term safety and effectiveness in young adults.


Assuntos
Marca-Passo Artificial , Humanos , Adulto Jovem , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Equipamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
14.
Heart Rhythm ; 20(4): 547-551, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36526165

RESUMO

BACKGROUND: Until recently, remote interrogation and reprogramming of therapeutic cardiac implantable electronic devices (CIEDs) have been virtually nonexistent owing to technical challenges and safety concerns. It could be extremely useful, in particular in case of emergencies, when patients live far from CIED professionals or during enforced physical distancing. OBJECTIVE: We investigated the feasibility and safety of a custom solution for remote interrogation and reprogramming of CIEDs from various manufacturers in various clinically relevant situations. METHODS: Our solution consists of remote controlling CIED programmers through screen capture and remote cursor control. In this multicenter feasibility study, the primary outcome was technical feasibility (% of success) and safety (absence of complication) of interrogation and reprogramming when indicated in clinically driven encounters. RESULTS: A total of 115 remote interrogations were performed in 110 patients: within the hospital (n = 73), medium range (50-100 km; n = 22), and long range (>5000 km; n = 20). Implanted devices were pacemakers (n = 85) and implantable cardioverter-defibrillators (n = 25) from Abbott (N=13), Biotronik (n = 65), and MicroPort (n = 32). Patients were located in the outpatient clinic, cardiology department, radiology department (magnetic resonance imaging), operating room (per implantation), and intensive care unit. Teleworking was performed in 39 cases. Complete CIED interrogations succeeded in all patients with reprogramming in 56 of 115 sessions (49%). No clinical or technical complications occurred. The time lag for screen interaction was below 1 second. CONCLUSION: Remote interrogation and reprogramming of CIEDs are feasible and safe across disparate clinical contexts and distances. This strategy may enhance health care access and facilitate medical training, tele-expertise, and telework worldwide.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Humanos , Coração , Imageamento por Ressonância Magnética/métodos , Hospitais
15.
J Interv Card Electrophysiol ; 66(5): 1201-1209, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36459310

RESUMO

BACKGROUND: In patients with cardiac resynchronization therapy defibrillators (CRT-Ds), the need for implantable cardioverter-defibrillator (ICD) back-up may be questionable at time of CRT-D replacement (REP) if ICD implant criteria are no longer met due to an improved left ventricular ejection fraction (LVEF) and if no major ventricular arrhythmic event (VAE) occurred during the CRT-D lifetime. The aim of our study was to assess the relevance of ICD back-up and predictors of VAE after REP in primary prevention CRT-D patients. METHODS: The prospective, observational, international BioCONTINUE study investigated the rate of patients with at least 1 sustained VAE (sVAE) post-REP and searched for predictive factors of sVAE. RESULTS: Two hundred seventy-six patients (70 ± 10 years, 77% men, mean LVEF 40.6 ± 12.6%) were followed for 28.4 ± 10.2 months. The rate of patients with sVAE was 8.3%, 10.3%, and 21.2% at 1, 2, and 4 years post-REP. Patients without persistent ICD indication at REP still had a sVAE rate of 5.7% (95% CI 2.3-11.5%) at 2 years. In multivariate analysis, predictive factors of subsequent sVAE were (i) persistent ICD indication (hazard ratio (HR) 3.6; 95% CI 1.6-8.3; p = 0.003); (ii) 64-72 years of age as compared to ≥ 79 years (HR 3.7; 95% CI 1.4-9.7; p = 0.008); and (iii) ischemic heart disease (HR 4.4; 95% CI 2.1-9.3; p < 0.0001). CONCLUSIONS: The risk of sVAE (21.2% at 4 years post-REP) depends on age, ischemic heart disease, and ICD indication at the time of REP. A non-trivial risk of sVAE remains in patients without persistent ICD indication. CLINICAL TRIAL REGISTRATION: NCT02323503.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Insuficiência Cardíaca , Isquemia Miocárdica , Taquicardia Ventricular , Idoso , Feminino , Humanos , Masculino , Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Isquemia Miocárdica/terapia , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento , Função Ventricular Esquerda , Pessoa de Meia-Idade
17.
J Pediatr ; 253: 40-45.e1, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36113637

RESUMO

OBJECTIVE: The objective of this study was to evaluate the agreement of smartwatch-derived single-lead electrocardiogram (ECG) recordings with 12-lead ECGs for diagnosing electrocardiographic abnormalities. STUDY DESIGN: A 12-lead ECG and an ECG using Apple Watch were obtained in 110 children (aged 1 week to 16 years) with normal (n = 75) or abnormal (n = 35) 12-lead ECGs (atrioventricular block [7], supraventricular tachycardia [SVT] {5}, bundle branch block [12], ventricular preexcitation [6], long QT [5]). In children aged <6 years, the ECG recording was performed with the active participation of an adult who applied the neonate or child's finger to the crown of the watch. In older children, tracings were obtained after brief teaching without adult guidance. All 12-lead ECGs were independently evaluated by 2 blinded cardiologists. Apple Watch ECGs were independently evaluated by another blinded cardiologist. RESULTS: In 109 children (99.1%), the smartwatch tracing was of sufficient quality for evaluation. Smartwatch tracings were 84% sensitive and 100% specific for the detection of an abnormal ECG. All 75 normal tracings were correctly identified. Of the 35 children with abnormalities on 12-lead ECGs, 5 (14%) were missed, most often because of baseline wander and artifacts. Rhythm disorders (atrioventricular block or SVT) and bundle branch blocks were correctly detected in most cases (11 of 12 and 11 of 12, respectively); preexcitation and long QT was detected in 4 of 6 and 4 of 5, respectively. CONCLUSION: Smartwatch ECGs recorded with parental assistance in children aged up to 6 years and independently in older children have the potential to detect clinically relevant conditions.


Assuntos
Bloqueio Atrioventricular , Taquicardia Supraventricular , Adulto , Recém-Nascido , Humanos , Criança , Estudos de Viabilidade , Arritmias Cardíacas/diagnóstico , Eletrocardiografia , Taquicardia Supraventricular/diagnóstico
20.
Card Electrophysiol Clin ; 14(2): 213-221, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35715079

RESUMO

The degree and pattern of conduction disease seem determinant when assessing potential cardiac resynchronization therapy (CRT) candidates. In the present review, the authors discuss the available noninvasive techniques that can be used to acquire ventricular activation time maps. They describe what body surface mapping has taught us about left bundle branch block, right bundle branch block, intraventricular conduction delay, and right ventricular pacing and discuss the ability of derived parameters of electrical dyssynchrony to predict long-term clinical response to CRT or His bundle pacing.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Mapeamento Potencial de Superfície Corporal , Fascículo Atrioventricular , Bloqueio de Ramo/terapia , Terapia de Ressincronização Cardíaca/métodos , Eletrocardiografia/métodos , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA