Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 72
Filtrar
1.
Eur J Heart Fail ; 25(11): 1976-1984, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37702313

RESUMO

AIMS: Improvement of left ventricular ejection fraction is a major goal of heart failure (HF) treatment. However, data on clinical characteristics, exercise performance and prognosis in HF patients who improved ejection fraction (HFimpEF) are scarce. The study aimed to determine whether HFimpEF patients have a distinct clinical phenotype, biology and prognosis than HF patients with persistently reduced ejection fraction (pHFrEF). METHODS AND RESULTS: A total of 7948 patients enrolled in the Metabolic Exercise Cardiac Kidney Indexes (MECKI) score database were evaluated (median follow-up of 1490 days). We analysed clinical, laboratory, electrocardiographic, echocardiographic, exercise, and survival data from HFimpEF (n = 1504) and pHFrEF (n = 6017) patients. The primary endpoint of the study was the composite of cardiovascular death, left ventricular assist device implantation, and urgent heart transplantation. HFimpEF patients had lower HF severity: left ventricular ejection fraction 44.0 [41.0-47.0] versus 29.7 [24.1-34.5]%, B-type natriuretic peptide 122 [65-296] versus 373 [152-888] pg/ml, haemoglobin 13.5 [12.2-14.6] versus 13.7 [12.5-14.7] g/dl, renal function by the Modification of Diet in Renal Disease equation 72.0 [56.7-89.3] versus 70.4 [54.5-85.3] ml/min, peak oxygen uptake 62.2 [50.7-74.1] versus 52.6 [41.8-64.3]% predicted, minute ventilation-to-carbon dioxide output slope 30.0 [26.9-34.4] versus 32.1 [28.0-38.0] in HFimpEF and pHFrEF, respectively (p < 0.001 for all). Cardiovascular mortality rates were 26.6 and 46.9 per 1000 person-years for HFimpEF and pHFrEF, respectively (p < 0.001). Kaplan-Meier analysis showed that HFimpEF had better a long-term prognosis compared with pHFrEF patients. After adjustment for variables differentiating HFimpEF from pHFrEF, except echocardiographic parameters, the Kaplan-Meier curves showed the same prognosis. CONCLUSIONS: Heart failure with improved ejection fraction represents a peculiar group of HF patients whose clinical, laboratory, electrocardiographic, echocardiographic, and exercise characteristics parallel the recovery of systolic function. Nonetheless, these patients remain at risk for adverse outcome.


Assuntos
Insuficiência Cardíaca , Humanos , Volume Sistólico , Função Ventricular Esquerda , Teste de Esforço/métodos , Seguimentos , Prognóstico , Rim
2.
Radiol Med ; 127(7): 788-802, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35608758

RESUMO

Cardiovascular magnetic resonance (CMR) and computed tomography (CCT) are advanced imaging modalities that recently revolutionized the conventional diagnostic approach to congenital heart diseases (CHD), supporting echocardiography and often replacing cardiac catheterization. Nevertheless, correct execution and interpretation require in-depth knowledge of all technical and clinical aspects of CHD, a careful assessment of risks and benefits before each exam, proper imaging protocols to maximize diagnostic information, minimizing harm. This position paper, written by experts from the Working Group of the Italian Society of Pediatric Cardiology and from the Italian College of Cardiac Radiology of the Italian Society of Medical and Interventional Radiology, is intended as a practical guide for applying CCT and CMR in children and adults with CHD, wishing to support Radiologists, Pediatricians, Cardiologists and Cardiac Surgeons in the multimodality diagnostic approach to these patients. The first part provides a review of the most relevant literature in the field, describes each modality's advantage and drawback, making considerations on the main applications, image quality, and safety issues. The second part focuses on clinical indications and appropriateness criteria for CMR and CCT, considering the level of CHD complexity, the clinical and logistic setting and the operator expertise.


Assuntos
Cardiologia , Cardiopatias Congênitas , Adulto , Criança , Consenso , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Radiologia Intervencionista , Tomografia Computadorizada por Raios X
4.
Ann Biomed Eng ; 49(2): 627-641, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32804291

RESUMO

Congenital bicuspid aortic valve (BAV) consists of two fused cusps and represents a major risk factor for calcific valvular stenosis. Herein, a fully coupled fluid-structure interaction (FSI) BAV model was developed from patient-specific magnetic resonance imaging (MRI) and compared against in vivo 4-dimensional flow MRI (4D Flow). FSI simulation compared well with 4D Flow, confirming direction and magnitude of the flow jet impinging onto the aortic wall as well as location and extension of secondary flows and vortices developing at systole: the systolic flow jet originating from an elliptical 1.6 cm2 orifice reached a peak velocity of 252.2 cm/s, 0.6% lower than 4D Flow, progressively impinging on the ascending aorta convexity. The FSI model predicted a peak flow rate of 22.4 L/min, 6.7% higher than 4D Flow, and provided BAV leaflets mechanical and flow-induced shear stresses, not directly attainable from MRI. At systole, the ventricular side of the non-fused leaflet revealed the highest wall shear stress (WSS) average magnitude, up to 14.6 Pa along the free margin, with WSS progressively decreasing towards the belly. During diastole, the aortic side of the fused leaflet exhibited the highest diastolic maximum principal stress, up to 322 kPa within the attachment region. Systematic comparison with ground-truth non-invasive MRI can improve the computational model ability to reproduce native BAV hemodynamics and biomechanical response more realistically, and shed light on their role in BAV patients' risk for developing complications; this approach may further contribute to the validation of advanced FSI simulations designed to assess BAV biomechanics.


Assuntos
Doença da Válvula Aórtica Bicúspide/diagnóstico por imagem , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Fenômenos Biomecânicos , Feminino , Hemodinâmica , Humanos , Imageamento por Ressonância Magnética , Modelagem Computacional Específica para o Paciente , Estresse Mecânico
5.
Acta Radiol ; 62(3): 334-340, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32475124

RESUMO

BACKGROUND: T1 mapping is emerging as a powerful tool in cardiac magnetic resonance (CMR) to evaluate diffuse fibrosis. However, right ventricular (RV) T1 mapping proves difficult due to the limited wall thickness in diastolic phase. Several studies focused on systolic T1 mapping, albeit only on the left ventricle (LV). PURPOSE: To estimate intra- and inter-observer variability of native T1 (nT1) mapping of the RV, and its correlations with biventricular and pulmonary function in patients with congenital heart disease (CHD). MATERIAL AND METHODS: In this retrospective, observational, cross-sectional study we evaluated 36 patients with CHD, having undergone CMR on a 1.5-T scanner. LV and RV functional evaluations were performed. A native modified look-locker inversion recovery short-axis sequence was acquired in the systolic phase. Intra- and inter-reader reproducibility were reported as complement to 100% of the ratio between coefficient of reproducibility and mean. Spearman ρ and Mann-Whitney U-test were used to compare distributions. RESULTS: Intra- and inter-reader reproducibility was 84% and 82%, respectively. Median nT1 was 1022 ms (interquartile range [IQR] 1108-972) for the RV and 947 ms (IQR 986-914) for the LV. Median RV-nT1 was 1016 ms (IQR 1090-1016) in patients with EDVI ≤100 mL/m2 and 1100 ms (IQR 1113-1100) in patients with EDVI >100 mL/m2 (P = 0.049). A significant negative correlation was found between RV ejection fraction and RV-nT1 (ρ = -0.284, P = 0.046). CONCLUSION: Systolic RV-nT1 showed a high reproducibility and a negative correlation with RV ejection fraction, potentially reflecting an adaptation of the RV myocardium to pulmonary valve/conduit (dys)-function.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Função Ventricular Esquerda/fisiologia , Função Ventricular Direita/fisiologia , Adolescente , Adulto , Estudos Transversais , Feminino , Cardiopatias Congênitas/complicações , Humanos , Imageamento por Ressonância Magnética , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Volume Sistólico/fisiologia , Sístole/fisiologia , Adulto Jovem
6.
J Matern Fetal Neonatal Med ; 34(4): 547-554, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31106637

RESUMO

Objective: To analyze the more recent outcomes of fetuses with different laterality defects.Material and methods: Out of 1508 fetuses with congenital heart disease (CHD) diagnosed by echocardiography between January 1995 and December 2015, 94 (6.3%) presented abnormal visceroatrial situs: 42 till December 2002 (group 1, analyzed retrospectively) and 52 since then until December 2015 (group 2, analyzed prospectively). Twenty-one had left isomerism (Lisom), 22 right isomerism (Risom), 16 situs inversus- dextrocardia (SVI-dx), 5 situs inversus- levocardia (SVI-levo), and 30 situs solitus-dextrocardia (SSol-dx).Results: Seventy-six cases (81%) had CHD, more frequently complex atrioventricular defect. Eighteen cases showed normal heart: half of subgroups SVI-dx and SVI-levo, a third of SSol-dx. Postoperative mortality in continuing pregnancy in group 2 was 43.7 versus 40% in group 1, lower in SVs-dx (0 versus 50%) and Lisom (33.3 versus 66.7%), worse in Risom (71.4 versus 25%). Total mortality in group 2 was 48.3 versus 55% in group 1, better in Ssol-dx (37.5 versus 50%) and in Lisom (27.4 versus 71.4%). In isolated forms all but one case are alive.Conclusions: Our fetal cases presented a relevant mortality in both periods. The outcomes were slightly better in a more recent era in SSol and Lisom.What is known about this topic?Out of laterality defects, the heterotaxies (i.e. left and right isomerism) are known to be associated to a relevant mortality in fetal and neonatal cases.Heterotaxies have a variable position of the heart, but some authors evaluated only those with dextrocardia in their studies on different laterality defects.Controversial data are presented in the literature for the outcomes of fetuses with laterality defects. Many large studies analyzed the data of a very long time period in which it is opinable to compare the results of the treatment, because of a recent improved management and surgical techniques.What does this study add?Our study presents an experience of a single center with cases of different types of laterality defects observed during a routine fetal echocardiography, not only heterotaxies.The knowledge of different laterality defects and of their characteristics (association with cardiac and extracardiac anomalies or with normal heart) is useful for the prenatal counseling.We compare the postoperative and total mortality in more recent period (since 2003) with respect to the previous era (1995-2002).


Assuntos
Cardiopatias Congênitas , Síndrome de Heterotaxia , Situs Inversus , Ecocardiografia , Feminino , Feto , Cardiopatias Congênitas/diagnóstico por imagem , Síndrome de Heterotaxia/diagnóstico por imagem , Síndrome de Heterotaxia/epidemiologia , Humanos , Recém-Nascido , Gravidez , Estudos Retrospectivos
7.
Cardiol Young ; 30(11): 1572-1587, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33109300

RESUMO

The recommendations of the Association for European Paediatric and Congenital Cardiology for basic training in paediatric and congenital cardiology required to be recognised as a paediatric cardiologist by the Association for European Paediatric and Congenital Cardiology are described below. Those wishing to achieve more advanced training in particular areas of paediatric cardiology should consult the training recommendations of the different Association for European Paediatric and Congenital Cardiology Working Groups available on the Association for European Paediatric and Congenital Cardiology website (www.aepc.org) and the respective publications 1-6. The development of training requirements is the responsibility of the Educational Committee and the Association for European Paediatric and Congenital Cardiology Council in collaboration with the Working Groups of the Association for European Paediatric and Congenital Cardiology. Trainees should be exposed to all aspects of general paediatric and congenital cardiology from fetal life to adolescence and adulthood. Centres performing generalised and specialised work in paediatric and congenital cardiology should be committed to deliver postgraduate training. At each training institute, trainers should be appointed to supervise and act as mentors to the trainees. Association for European Paediatric and Congenital Cardiology will provide basic teaching courses to supplement the training process.


Assuntos
Cardiologia , Cardiopatias Congênitas , Adolescente , Adulto , Criança , Humanos
9.
J Biomech ; 105: 109796, 2020 05 22.
Artigo em Inglês | MEDLINE | ID: mdl-32423542

RESUMO

Endovascular stenting has recently become a standard treatment for native coarctation of the aorta (CoA) in children and young adults, given the efficacy in relieving vessel obstruction with a low incidence of adverse events. Yet, despite the short-term success of the technique, late hypertension remains an endemic risk. To assess the impact of the percutaneous procedure on the aortic wall biomechanics, we designed a novel finite element (FE) protocol for the simulation of endovascular stenting in three patient-specific CoA anatomies, developing a remeshing procedure that allows for coping with different CoA severities. Our FE protocol was able to yield numerical results on stent distortions and stresses, as well as on changes in aortic wall stresses and distensibility. These results were consistent with intraprocedural in-vivo evidences and with previous findings from the literature, and they suggest that our numerical approach could be used to understand the role of patient specific anatomical features (CoA severity and arch type) on the post-stenting aortic biomechanics. If soundly validated on a vast cohort of patients, our approach could support patient selection for the procedure.


Assuntos
Coartação Aórtica , Stents , Aorta , Fenômenos Biomecânicos , Criança , Análise de Elementos Finitos , Humanos , Resultado do Tratamento , Adulto Jovem
10.
J Pediatr Surg ; 55(11): 2322-2328, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32200977

RESUMO

BACKGROUND/PURPOSE: The Spitz classification for esophageal atresia with/without tracheoesophageal fistula (EA/TEF) predicts mortality. This study evaluates the contemporary relevance of the Spitz classification and investigates predictors of morbidity. METHODS: EA/TEF patients born between 1995 and 2018 at two centers were retrospectively reviewed. Clinical variables including sex, prenatal diagnosis, birth weight, prematurity, major congenital heart disease (MCHD), and pre-operative mechanical ventilation (POMV) were collected. Index admission composite morbidity was considered positive if: length-of-stay >90th percentile (139 days), ventilation days >90th percentile (24 days), and/or gastrostomy was used for long-term feeding. Multivariable regression determined predictors of index admission mortality and composite morbidity. A composite morbidity predictive algorithm was created. ROC curves evaluated model discrimination. RESULTS: Of 253 patients, 13 (5.1%) experienced index admission mortality. Of the patients not suffering mortality, 74 (31.6%) experienced composite morbidity. Only MCHD predicted mortality (p = 0.001); birth weight did not (p = 0.173). There was no difference between the Spitz classification and MCHD alone in predicting mortality risk (p = 0.198); both demonstrated very good discrimination. Prenatal diagnosis, POMV, prematurity, and male sex predicted composite morbidity risk (p < 0.001; p = 0.008; p = 0.009; p = 0.05). An algorithm incorporating these predictors demonstrated good discrimination (AUC = 0.784; 95% CI: 0.724, 0.844). CONCLUSIONS: The Spitz classification maintains contemporary relevance for mortality risk, though birth weight can be de-emphasized. A new morbidity risk algorithm is proposed for early postnatal counseling. TYPE OF STUDY: Prognosis study. LEVEL OF EVIDENCE: Level IV.


Assuntos
Atresia Esofágica/diagnóstico , Atresia Esofágica/mortalidade , Fístula Traqueoesofágica , Feminino , Humanos , Recém-Nascido , Masculino , Morbidade , Gravidez , Estudos Retrospectivos , Índice de Gravidade de Doença , Fístula Traqueoesofágica/epidemiologia , Resultado do Tratamento
11.
Metab Syndr Relat Disord ; 18(2): 110-118, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31976814

RESUMO

Background: Different studies have indicated that thiazide diuretics can increase the risk of developing type 2 diabetes (T2D). Therefore, in this study, we investigated whether switching from hydrochlorothiazide (HCTZ) to amlodipine resulted in ameliorating different cardiovascular and metabolic measures in hypertensive patients with or without T2D. Methods: This study [Diuretics and Diabetes Control (DiaDiC)] was a 6-week, single-blind, single-center randomized controlled trial. The first 20 normal glucose-tolerant, 20 prediabetic, and 20 T2D consecutive patients were randomized to continue the previous antihypertensive treatment with HCTZ (12.5-25 mg/day) or to switch from HCTZ to amlodipine (2.5-10 mg/day). The primary endpoints were the absolute change in 7-day continuous subcutaneous glucose monitoring (CSGM) glycemia, serum uric acid concentrations, and endothelial function [measured as flow-mediated dilation (FMD)]. Other secondary endpoints were investigated, including changes in glycated hemoglobin (HbA1c), glycemic variability from 7-day CSGM, and the estimated glomerular filtration rate (eGFR). Results: Amlodipine treatment was associated with a significant reduction in HbA1c (P = 0.03) for both 7-day CSGM glycemia (P = 0.01) and glycemic variability (coefficient of variability %: HCTZ +3%, amlodipine -2.8%), and a reduction in uric acid concentrations (P < 0.001), especially in participants with T2D or prediabetes. Following amlodipine treatment, a significant increase in both eGFR (P = 0.01) and FMD (P = 0.02) was also observed. Conclusions: This study demonstrates that the replacement of HCTZ with amlodipine has several metabolic and cardiovascular beneficial effects. However, further intervention studies are necessary to confirm the clinical effects of thiazides, especially in diabetic people and in those at risk of diabetes.


Assuntos
Anlodipino/uso terapêutico , Anti-Hipertensivos/uso terapêutico , Pressão Sanguínea/efeitos dos fármacos , Bloqueadores dos Canais de Cálcio/uso terapêutico , Diabetes Mellitus Tipo 2 , Substituição de Medicamentos , Metabolismo Energético/efeitos dos fármacos , Hidroclorotiazida/uso terapêutico , Hipertensão/tratamento farmacológico , Inibidores de Simportadores de Cloreto de Sódio/uso terapêutico , Idoso , Anlodipino/efeitos adversos , Anti-Hipertensivos/efeitos adversos , Biomarcadores/sangue , Bloqueadores dos Canais de Cálcio/efeitos adversos , Diabetes Mellitus Tipo 2/diagnóstico , Feminino , Humanos , Hidroclorotiazida/efeitos adversos , Hipertensão/sangue , Hipertensão/diagnóstico , Hipertensão/fisiopatologia , Itália , Masculino , Pessoa de Meia-Idade , Método Simples-Cego , Inibidores de Simportadores de Cloreto de Sódio/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
12.
Magn Reson Imaging ; 68: 18-29, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-31981709

RESUMO

PURPOSE: We exploited 4-dimensional flow magnetic resonance imaging (4D Flow), combined with a standardized in vitro setting, to establish a comprehensive benchmark for the systematic hemodynamic comparison of surgical aortic bioprosthetic valves (BPVs). MATERIALS AND METHODS: 4D Flow analysis was performed on two small sizes of three commercialized pericardial BPVs (Trifecta™ GT, Carpentier-Edwards PERIMOUNT Magna and Crown PRT®). Each BPV was tested over a clinically pertinent range of continuous flow rates within an in vitro MRI-compatible system, equipped with pressure transducers. In-house 4D Flow post-processing of the post-valvular velocity field included the quantification of BPV effective orifice area (EOA), transvalvular pressure gradients (TPG), kinetic energy and viscous energy dissipation. RESULTS: The 4D Flow technique effectively captured the 3-dimensional flow pattern of each device. Trifecta exhibited the lowest range of velocity and kinetic energy, maximized EOA (p < 0.0001) and minimized TPGs (p ≤ 0.015) if compared with Magna and Crown, these reporting minor EOA difference s (p ≥ 0.042) and similar TPGs (p ≥ 0.25). 4D Flow TPGs estimations strongly correlated against ground-truth data from pressure transducers; viscous energy dissipation proved to be inversely proportional to the fluid jet penetration. CONCLUSION: The proposed 4D Flow analysis pinpointed consistent hemodynamic differences among BPVs, highlighting the not negligible effect of device size on the fluidynamic outcomes. The efficacy of non-invasive 4D Flow MRI protocol could shed light on how standardize the comparison among devices in relation to their actual hemodynamic performances and improve current criteria for their selection.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Benchmarking , Bioprótese/normas , Próteses Valvulares Cardíacas/normas , Imageamento por Ressonância Magnética , Desenho de Prótese/normas , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Hemodinâmica , Humanos , Imageamento Tridimensional , Técnicas In Vitro , Cinética
13.
Clin Chim Acta ; 501: 20-26, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31809746

RESUMO

BACKGROUND: The increased use of antidepressant treatment during pregnancy occurred without firm evidence on safety/efficacy. The present study investigated the correlation among S100B and paroxetine blood levels with the occurrence of short-term post-natal neurological abnormalities. METHODS: We conducted a cross-sectional study in 50 pregnant women using paroxetine because of depression and in 150 controls. Standard laboratory parameters and S100B were measured at seven monitoring time-points (maternal blood: T1, 16-20 wks; T2, 27-30 wks; T3, 35-40 wks; T4, at delivery; amniotic fluid, T5; venous and arterial cord blood, T6-T7). Paroxetine levels were measured at T1-T6. Neurological outcome was set at 7th day from birth. RESULTS: Higher S100B concentrations at T1-T7 were found in the paroxetine-treated group. S100B correlated with paroxetine blood levels. The paroxetine/S100B ratio cut-off of 1.31 at T2 achieved sensitivity 100%, specificity 96.5% and positive/negative predictive values 87.5-100, respectively, as a single marker to predict adverse neonatal neurological outcome. CONCLUSIONS: The present study offers additional support to the usefulness of longitudinal S100B and drug level monitoring in depressed pregnant women and in the early detection of cases at risk for short-term neurological abnormalities. Results open the way at further investigations correlating antidepressant drugs and neurobiomarkers in the maternal bloodstream.


Assuntos
Líquido Amniótico/química , Antidepressivos/farmacologia , Doenças do Sistema Nervoso Central/tratamento farmacológico , Relações Materno-Fetais/efeitos dos fármacos , Paroxetina/farmacologia , Subunidade beta da Proteína Ligante de Cálcio S100/sangue , Adulto , Biomarcadores/sangue , Doenças do Sistema Nervoso Central/sangue , Técnicas de Laboratório Clínico , Estudos Transversais , Relação Dose-Resposta a Droga , Feminino , Humanos , Gravidez
14.
Clin Chem Lab Med ; 58(4): 471-486, 2020 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-31851609

RESUMO

The early detection of perinatal brain damage in preterm and term newborns (i.e. intraventricular hemorrhage, periventricular leukomalacia and perinatal asphyxia) still constitute an unsolved issue. To date, despite technological improvement in standard perinatal monitoring procedures, decreasing the incidence of perinatal mortality, the perinatal morbidity pattern has a flat trend. Against this background, the measurement of brain constituents could be particularly useful in the early detection of cases at risk for short-/long-term brain injury. On this scenario, the main European and US international health-care institutions promoted perinatal clinical and experimental neuroprotection research projects aimed at validating and including a panel of biomarkers in the clinical guidelines. Although this is a promising attempt, there are several limitations that do not allow biomarkers to be included in standard monitoring procedures. The main limitations are: (i) the heterogeneity of neurological complications in the perinatal period, (ii) the small cohort sizes, (iii) the lack of multicenter investigations, (iv) the different techniques for neurobiomarkers assessment, (iv) the lack of consensus for the validation of assays in biological fluids such as urine and saliva, and (v), the lack of reference curves according to measurement technique and biological fluid. In the present review we offer an up-to-date overview of the most promising developments in the use of biomarkers in the perinatal period such as calcium binding proteins (S100B protein), vasoactive agents (adrenomedullin), brain biomarkers (activin A, neuron specific enolase, glial fibrillary acidic protein, ubiquitin carboxyl-terminal hydrolase-L1) and oxidative stress markers.


Assuntos
Biomarcadores/líquido cefalorraquidiano , Lesões Encefálicas/diagnóstico , Biomarcadores/sangue , Biomarcadores/urina , Feminino , Proteína Glial Fibrilar Ácida/sangue , Proteína Glial Fibrilar Ácida/líquido cefalorraquidiano , Proteína Glial Fibrilar Ácida/urina , Humanos , Assistência Perinatal , Gravidez , Subunidade beta da Proteína Ligante de Cálcio S100/sangue , Subunidade beta da Proteína Ligante de Cálcio S100/líquido cefalorraquidiano , Subunidade beta da Proteína Ligante de Cálcio S100/urina , Saliva/metabolismo , Ubiquitina Tiolesterase/sangue , Ubiquitina Tiolesterase/líquido cefalorraquidiano , Ubiquitina Tiolesterase/urina
15.
Int J Cardiol ; 309: 33-39, 2020 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-31839428

RESUMO

BACKGROUND: Identification of adequate landing zone for transcatheter pulmonary valve implantation (TPVI) is crucial to successfully treat an aneurysmatic native right ventricle outflow tract (RVOT); three-dimensional (3D) patient-tailored digital and physical printed models are available but their actual strengths and weaknesses still not well documented. The aim of the study was to tackle TPVI planning in the dysfunctional and borderline RVOT exploiting both digital and physical printed 3D patient-specific models. METHODS: Electrocardiographically gated computed tomography (CT) angiography was segmented and anatomical RVOT geometrical changes dynamically tracked throughout the cardiac cycle using in-house processing. A compliant 3D-printed model was manufactured from the diastolic rest phase to test in vitro the catheter-based procedure feasibility; results were compared against CT-derived in vivo measurements and the actual catheterization outcome. RESULTS: CT-gated analysis successfully quantified in vivo RVOT dynamic changes corroborating the feasibility of non-conventional pulmonary jailing percutaneous intervention. Clinicians used the 3D-printed model to test the steps of the jailing procedure; yet, the deformable 3D model printed at diastole underestimated the final implant dimensions obtained during cardiac catheterization by the same operators. CONCLUSIONS: Multidisciplinary synergy between CT-gated analysis and pre-procedural tests on 3D-printed phantoms can help the interventional team to tackle complex TPVI procedures. To fully exploit 3D-printed models, adequate selection of the still frame to print and tuning of printing material properties is crucial and can be aided by 3D dynamic virtual models.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento
16.
Diagnostics (Basel) ; 9(3)2019 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-31540197

RESUMO

BACKGROUND: Pediatric open-heart surgery with cardiopulmonary bypass (CPB) still remains a risky interventional procedure at high mortality/morbidity. To date, there are no clinical, laboratory, and/or monitoring parameters providing useful information on perioperative stress. We therefore investigated whether blood concentrations of glutathione (GSH), a powerful endogenous antioxidant, changed in the perioperative period. METHODS: We conducted an observational study in 35 congenital heart disease (CHD) children in whom perioperative standard laboratory and monitoring parameters and GSH blood levels were assessed at five monitoring time points. RESULTS: GSH showed a pattern characterized by a progressive increase from pre-surgery up to 24 h after surgery, reaching its highest peak at the end of CPB. GSH measured at the end of CPB correlated with CPB duration, cross-clamping, arterial oxygen partial pressure, and with body core temperature. CONCLUSIONS: The increase in GSH levels in the perioperative period suggests a compensatory mechanism to oxidative damage during surgical procedure. Caution is needed in controlling different CPB phases, especially systemic reoxygenation in a population that is per se more prone to oxidative stress/damage. The findings may point the way to detecting the optimal temperature and oxygenation target by biomarker monitoring.

17.
Molecules ; 24(18)2019 Sep 04.
Artigo em Inglês | MEDLINE | ID: mdl-31487945

RESUMO

Background: To evaluate the effectiveness/side-effects of osteopathic manipulation treatment (OMT) performed on the 7th post-natal day, on cerebro-splanchnic oximetry, tissue activation and hemodynamic redistribution in late preterm (LP) infants by using near infrared spectroscopy (NIRS). Methods: Observational pretest-test study consisting in a cohort of 18 LPs who received OMT on the 7th post-natal day. NIRS monitoring was performed at three different time-points: 30 min before (T0), (30 min during (T1) and 30 min after OMT (T2). We evaluated the effects of OMT on the following NIRS parameters: cerebral (c), splanchnic (s) regional oximetry (rSO2), cerebro-splanchnic fractional tissue oxygen extraction (FTOE) and hemodynamic redistribution (CSOR). Results: crSO2 and cFTOE significantly (P < 0.001) improved at T0-T2; srSO2 significantly (P < 0.001) decreased and sFTOE increased at T0-T1. Furthermore, srSO2 and sFTOE significantly improved at T1-T2. Finally, CSOR significantly (P < 0.05) increased at T0-T2. Conclusions: The present data show that OMT enhances cerebro-splanchnic oximetry, tissue activation and hemodynamic redistribution in the absence of any adverse clinical or laboratory pattern. The results indicate the usefulness of further randomized studies in wider populations comparing the effectiveness of OMT with standard rehabilitation programs.


Assuntos
Circulação Cerebrovascular , Osteopatia , Oximetria , Circulação Esplâncnica , Adulto , Gasometria , Feminino , Humanos , Recém-Nascido , Masculino , Osteopatia/métodos , Oximetria/métodos , Oxigênio/metabolismo , Espectroscopia de Luz Próxima ao Infravermelho
18.
J Biomech ; 94: 13-21, 2019 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-31326119

RESUMO

Severity of aortic coarctation (CoA) is currently assessed by estimating trans-coarctation pressure drops through cardiac catheterization or echocardiography. In principle, more detailed information could be obtained non-invasively based on space- and time-resolved magnetic resonance imaging (4D flow) data. Yet the limitations of this imaging technique require testing the accuracy of 4D flow-derived hemodynamic quantities against other methodologies. With the objective of assessing the feasibility and accuracy of this non-invasive method to support the clinical diagnosis of CoA, we developed an algorithm (4DF-FEPPE) to obtain relative pressure distributions from 4D flow data by solving the Poisson pressure equation. 4DF-FEPPE was tested against results from a patient-specific fluid-structure interaction (FSI) simulation, whose patient-specific boundary conditions were prescribed based on 4D flow data. Since numerical simulations provide noise-free pressure fields on fine spatial and temporal scales, our analysis allowed to assess the uncertainties related to 4D flow noise and limited resolution. 4DF-FEPPE and FSI results were compared on a series of cross-sections along the aorta. Bland-Altman analysis revealed very good agreement between the two methodologies in terms of instantaneous data at peak systole, end-diastole and time-averaged values: biases (means of differences) were +0.4 mmHg, -1.1 mmHg and +0.6 mmHg, respectively. Limits of agreement (2 SD) were ±0.978 mmHg, ±1.06 mmHg and ±1.97 mmHg, respectively. Peak-to-peak and maximum trans-coarctation pressure drops obtained with 4DF-FEPPE differed from FSI results by 0.75 mmHg and -1.34 mmHg respectively. The present study considers important validation aspects of non-invasive pressure difference estimation based on 4D flow MRI, showing the potential of this technology to be more broadly applied to the clinical practice.


Assuntos
Coartação Aórtica/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Modelos Cardiovasculares , Algoritmos , Aorta , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco , Estudos de Viabilidade , Análise de Elementos Finitos , Hemodinâmica , Humanos , Modelagem Computacional Específica para o Paciente , Pressão , Reprodutibilidade dos Testes
20.
Intern Emerg Med ; 14(7): 1091-1100, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30895427

RESUMO

Left ventricular ejection fraction (EF) is helpful to differentiate heart failure (HF) phenotype in clinical practice. The aim of the study was to identify simple echocardiographic predictors of post-discharge all-cause mortality in hospitalized HF patients. Patients with acute HF (75 ± 9.8 years), classified in preserved (≥ 50%) and reduced (< 50%) EF (HFpEF and HFrEF, respectively), were enrolled. The mean follow-up period was of 25.4 months. Patients definitively analyzed were 135. At multivariate Cox model, right ventricular diameter (RVd), inferior vena cava diameter (IVCd) and blood urea nitrogen (BUN) resulted to be significantly associated with all-cause mortality in HFpEF (HR 2.4, p = 0.04; HR 1.06, p = 0.02; HR 1.02, p = 0.01), whereas, left atrial volume (LAV) was significantly associated with mortality in HFrEF (HR 1.06, p = 0.006). Excluding LAV from the model, only COPD remained an independent predictor of all-cause mortality (HR 2.15, p = 0.04) in HFrEF. At Kaplan-Meier analysis, no differences of survival between HFrEF and HFpEF were found, however, significantly increased all-cause mortality for higher values of basal-RVd, BUN, and IVCd (log-rank p = 0.0065, 0.0063, 0.0005) in HFpEF, and for COPD and higher LAV (log-rank p = 0.0046, p = 0.033) in HFrEF. These data are indicative that in patients hospitalized with HF, EF is not a suitable predictor of long-term all-cause mortality, whereas, right ventricular volumetric remodeling and IVCd have a prognostic role in HFpEF as well as LAV in HFrEF. Our study suggests that besides EF, other echocardiographic parameters are helpful to optimize the phenotyping and prognostic stratification of HF.


Assuntos
Insuficiência Cardíaca/mortalidade , Ventrículos do Coração/patologia , Prognóstico , Volume Sistólico/fisiologia , Pesos e Medidas/instrumentação , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia/métodos , Ecocardiografia/estatística & dados numéricos , Feminino , Insuficiência Cardíaca/classificação , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/anormalidades , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Pesos e Medidas/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA