Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 65
Filtrar
1.
Biology (Basel) ; 13(7)2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-39056666

RESUMO

This study evaluated the bone incorporation process of a screw-shaped internal fixation device made of poly (L-lactide-co-D, L-lactide) (PLDLLA). Thirty-two male Wistar rats received 32 fixation devices (2 mm × 6 mm) randomly assigned to either the right or left tibia and one implant in each animal. After 7, 14, 28, and 42 days, the rats were euthanized and the specimens were subjected to microtomographic computed tomography (microCT) and histomorphometric analyses to evaluate bone interface contact (BIC%) and new bone formation (NBF%) in cortical and cancellous bone areas. The animals euthanized on days 28 and 42 were treated with calcein and alizarin red, and confocal LASER microscopy was performed to determine the mineral apposition rate (MAR). Micro-CT revealed a higher percentage of bone volume (p < 0.006), trabecular separation (p < 0.001), and BIC in the cortical (p < 0.001) and cancellous (p = 0.003) areas at 28 and 42 days than at 7 and 14 days. The cortical NBF at 42 days was greater than that at 7 and 14 days (p = 0.022). No statistically significant differences were observed in cancellous NBF or MAR at 28 and 42 days. Based on these results, it can be seen that the PLDLLA internal fixation device is biocompatible and allows new bone formation around the screw thread.

2.
Biology (Basel) ; 13(7)2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39056725

RESUMO

(1) Objective: The aim of this study was to assess the biological behavior of bone tissue on a machined surface (MS) and modifications made by a laser beam (LS) and by a laser beam incorporated with hydroxyapatite (HA) using a biomimetic method without thermic treatment (LHS). (2) Methods: Scanning electron microscopy coupled with energy-dispersive X-ray spectrometry (SEM/EDX) was performed before and after installation in the rabbit tibiae. A total of 20 Albinus rabbits randomly received 30 implants of 3.75 × 10 mm in the right and left tibias, with two implants on each surface in each tibia. In the animals belonging to the 4-week euthanasia period group, intramuscular application of the fluorochromes calcein and alizarin was performed. In implants placed mesially in the tibiofemoral joint, biomechanical analysis was performed by means of a removal torque (N/cm). The tibias with the implants located distally to the joint were submitted for analysis by confocal laser microscopy (mineral apposition rate) and for histometric analysis by bone contact implant (%BIC) and newly formed bone area (%NBA). (3) Results: The SEM showed differences between the surfaces. The biomechanical analysis revealed significant differences in removal torque values between the MSs and LHSs over a 2-week period. Over a 4-week period, both the LSs and LHSs demonstrated removal torque values statistically higher than the MSs. BIC of the LHS implants were statistically superior to MS at the 2-week period and LHS and LS surfaces were statistically superior to MS at the 4-week period. Statistical analysis of the NBA of the implants showed difference between the LHS and MS in the period of 2 weeks. (4) Conclusions: The modifications of the LSs and LHSs provided important physicochemical modifications that favored the deposition of bone tissue on the surface of the implants.

3.
Dent J (Basel) ; 12(7)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39056987

RESUMO

Dental implant fractures pose a significant challenge to long-term treatment success. This systematic review aims to comprehensively examine the clinical factors influencing dental implant fractures (IFs). Furthermore, strategies to choose the right type of implant and prevent this complication are addressed. A systematic search was conducted across PubMed, Scopus, and Web of Science databases. Eligible studies included retrospective case-control, prospective cohort studies, and clinical trials. The initial search yielded 361 articles, of which 312 were excluded being these reviews, case reports, irrelevant, or written in languages other than English. This left 49 articles, with only 6 meeting the eligibility criteria for an in-depth review. These studies, all retrospective case-control, examine implant characteristics, patient demographics, surgical and prosthetic variables, biomechanical and functional factors, clinical and procedural variables, complications and maintenance issues. The risk of bias was assessed as low using the ROBINS-I tool. Key findings suggest a correlation between implant diameter and structural resistance, with wider implants demonstrating reduced fracture risk. Additionally, posterior regions, especially molars and premolars, exhibit higher susceptibility to IFs due to increased masticatory forces. Implant design and material may considerably influence fracture risk, with conical implants and screw-retained prostheses showing higher vulnerability. Biomechanical overload, particularly in patients with bruxism, emerges as a primary contributing factor to IFs. Prosthesis type significantly influences fracture incidence, with cantilever prostheses posing a higher risk due to increased stress. Peri-implant bone loss is strongly associated with IFs, emphasizing the need for meticulous preoperative assessments and individualized management strategies. Future research should prioritize larger and heterogeneous populations with long-term follow-up and standardized methodologies to enhance the generalizability and comparability of findings. Randomized controlled trials and biomechanical studies under controlled conditions are also essential to elucidate the complex interactions contributing to IFs and developing effective prevention strategies. Additionally, integrating patient-reported outcomes may offer a comprehensive understanding of the impact of IFs on quality of life.

4.
BMC Oral Health ; 24(1): 531, 2024 May 04.
Artigo em Inglês | MEDLINE | ID: mdl-38704566

RESUMO

BACKGROUND: Oral Health-Related Quality of Life (OHRQoL) is a comprehensive concept covering daily comfort, self-esteem, and satisfaction with oral health, including functional, psychological, and social aspects, as well as pain experiences. Despite abundant research on OHRQoL related to oral diseases and hygiene, there is limited data on how patients perceive changes after implant-prosthetic rehabilitation. This study aimed to evaluate OHRQoL and aesthetic perception using OHIP-14 and VAS scales respectively, before (baseline-TB), during (provisional prostheses-TP), and after (definitive prostheses-TD) implant-prosthetic rehabilitation. It also explored the impact of biological sex, substitution numbers, and aesthetic interventions on OHRQoL and VAS scores, along with changes in OHIP-14 domains. METHODS: A longitudinal prospective single-center observational cohort study was conducted with patients requiring implant-prosthetic rehabilitation. Quality of life relating to dental implants was assessed through the Italian version of Oral Health Impact Profile-14 (IOHIP-14), which has a summary score from 14 to 70. Patients' perceived aesthetic was analyzed through a VAS scale from 0 to 100. Generalized Linear Mixed Effect Models, Linear Mixed Effect Models, and Friedman test analyzed patient responses. RESULTS: 99 patients (35 males, 64 females) aged 61-74, receiving various prosthetic interventions, were enrolled. Both provisional and definitive prosthetic interventions significantly decreased the odds of a worse quality of life compared to baseline, with odds ratios of 0.04 and 0.01 respectively. VAS scores increased significantly after both interventions, with estimated increases of 30.44 and 51.97 points respectively. Patient-level variability was notable, with an Intraclass Correlation Coefficient (ICC) of 0.43. While biological sex, substitution numbers, and aesthetic interventions didn't significantly affect VAS scores, OHRQoL domains showed significant changes post-intervention. CONCLUSIONS: These findings support the effectiveness of implant-prosthetic interventions in improving the quality of life and perceived aesthetics of patients undergoing oral rehabilitation. They have important implications for clinical practice, highlighting the importance of individualized treatment approaches to optimize patient outcomes and satisfaction in oral health care.


Assuntos
Prótese Dentária Fixada por Implante , Estética Dentária , Saúde Bucal , Qualidade de Vida , Humanos , Masculino , Feminino , Estudos Prospectivos , Prótese Dentária Fixada por Implante/psicologia , Pessoa de Meia-Idade , Idoso , Estudos Longitudinais
5.
Clin Oral Implants Res ; 35(5): 547-559, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38372478

RESUMO

OBJECTIVES: The effect of the implant position within the prosthesis on bone remodeling is scarcely documented so far. Thus, the aim of the present study was to investigate whether central implants may suffer higher peri-implant marginal bone levels (MBL) compared to laterals in case of fixed splinted bridges supported by ≥ three implants. MATERIALS AND METHODS: Partially edentulous subjects rehabilitated with at least one fixed bridge supported by ≥ three dental implants were enrolled. MBL was assessed radiographically by means of intraoral radiographs acquired with phosphor plates and imported in a dedicated software. MBL was calculated as the distance between the implant platform level and the most coronal visible bone-to-implant contact. A three-level linear mixed effects model was used for investigating the fixed effect of patient-, prosthesis-, and implant-level variables on the MBL. RESULTS: Overall, 90 patients rehabilitated with 130 splinted fixed bridges supported by 412 implants were included. The median follow-up was 136 months. The mean peri-implant MBL resulted statistically significantly higher at central implants if compared to lateral implants (p < .01). The estimated MBL averages for central and external implants were 1.68 and 1.18 mm, respectively. The prosthesis-level variables suggested that a cement-retained bridge was prone to a significant 0.82 mm higher MBL than a screw-retained one. Implant surface showed an association with MBL changes, although less pronounced than implant retention. CONCLUSIONS: In case of ≥3 adjacent implants supporting splinted bridges, central implants were more predisposed to MBL compared to laterals. At the prosthesis level, implants supporting cement-retained bridges were statistically more susceptible to MBL compared to screw-retained ones. Surface characteristics can also influence MBL stability at the implant level.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Prótese Parcial Fixa , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Perda do Osso Alveolar/diagnóstico por imagem , Perda do Osso Alveolar/etiologia , Arcada Parcialmente Edêntula/cirurgia , Arcada Parcialmente Edêntula/reabilitação , Adulto
6.
Int J Periodontics Restorative Dent ; 0(0): 1-23, 2024 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-38363182

RESUMO

The present case series aims to investigate the use of polynucleotides mixed with hyaluronic acid (PNs-HA) in the form of gel to promote bone regeneration in horizontal alveolar defects. Overall, 6 adult patients underwent localized horizontal guided bone regeneration by means of xenogeneic bone substitute and a resorbable barrier with a staged approach. The graft consisted in a mixture of deproteinized bovine bone mineral (DBBM) particles and PNs-HA gel in a 3:1 ratio, respectively. The material was covered by a resorbable collagen membrane fixed with pins to the underlying bone. Implant placement was performed after 5 months. Healing proceeded uneventfully, and, upon re-entry, the graft appeared well vascularized and firmly attached to the recipient bone. Histologically, the regenerated bone appeared highly mineralized, well-organized in lamellae and totally embedding the residual granules of the biomaterial. Histomorphometric evaluations revealed that newly formed bone occupied on average 41.2% ± 12.4% of the analysed samples. Linear measurements performed on CBCT scans yielded an overall linear horizontal bone gain of 4.91 ± 0.88 mm. These data suggest that a mixture of DBBM and PNs-HA can be safely used to promote bone regeneration in case of horizontal alveolar defects.

7.
Dent J (Basel) ; 11(12)2023 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-38132418

RESUMO

AIM: Polydeoxyribonucleotide (PDRN) is a chain-like polymer derived from DNA. Recent in vitro and animal studies have showcased the beneficial impacts of PDRN on the process of bone mending, whether used on its own or in conjunction with other substances that aid in regeneration. This scoping review aims to synthesize the current understanding of how PDRNs influence bone healing. MATERIALS AND METHODS: The studies included in the screening procedure were randomized controlled clinical trials (RCTs), both retrospective and prospective case-control studies, as well as in vitro and in vivo investigations. Articles were sourced from PubMed (MEDLINE), Scopus, EMBASE, Web of Science, and Google Scholar electronic databases using the following MeSH terms: (polydeoxyribonucleotide) and (bone) and (regeneration). RESULTS: Initially, 228 articles were identified. Following the review process, a total of eight studies were ultimately examined. Among these, two were confined to laboratory studies, five were conducted on living organisms, and one encompassed both evaluations on living organisms and in vitro assessments. A descriptive qualitative approach was employed to present the data extracted from the studies that were included. CONCLUSIONS: PDRN has the potential to enhance the process of bone healing and the quantity of newly generated bone when combined with grafting materials. Future clinical studies are warranted to ascertain the appropriate clinical application of PDRN based on the dosage under consideration.

8.
Dent J (Basel) ; 11(11)2023 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-37999020

RESUMO

This technical note aims to present a recently developed computer-guided protocol characterized by titanium-reinforced stackable surgical guides during post-extractive implant placement and subsequent immediate loading. A full maxillary edentulism was rehabilitated with one-piece implants, starting from a pre-existing removable denture. 3D digital scans of the removable denture and upper and lower arches were performed. On this basis, a prototype with ideal esthetic and functional outcomes was realized and replicated into a custom-made radiological stent with markers. The superimposition of STL and DICOM files allowed virtual planning of one-piece implants in the ideal prosthetically driven position. The stackable guides, composed of a fixed base template and additional removable components, were then realized. The fixed template, initially secured with anchor pins to the bone, was no longer removed. The removable components, which were screwed to the base template, were used to perform implant surgery and immediate prosthetic loading. No surgical complications occurred, the implants achieved a minimum insertion torque of 35 Ncm, and immediate prosthetic loading was performed. The base template allowed for the maintenance of a fixed reference during the entire workflow, improving the transition between the digital project, the surgical procedure, and the prosthetic rehabilitation.

9.
J Funct Biomater ; 14(10)2023 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-37888194

RESUMO

The extraction of impacted third molars is a common but potentially complication-prone oral surgical procedure. Wound healing plays a vital role in preventing complications. This scoping review aimed to assess the clinical and microbiological aspects of various suture materials and cyanoacrylates. Unlike existing studies, we included more articles and comprehensively compared suture materials. Articles published in languages other than English; duplicate studies; studies deemed irrelevant for the specific research questions, including those analyzing different supplementary treatments or not corresponding to the abstract's content; ex vivo or experimental animal studies; studies lacking approval from an ethics committee; and narrative reviews, systematic reviews, or systematic and meta-analysis reviews were excluded. Thus, only 17 studies, published between 2000 and 2023, were included in the search. Suture techniques varied among surgeons, with debates on primary and secondary closure methods. A comparison of different suture materials and their effects on wound healing, infection rates, and other factors was described. Cyanoacrylate has also been used as an alternative to traditional sutures. Microbiological analysis showed varying bacterial adhesion based on the suture material, with silk sutures retaining more microbes than PTFE sutures. Clinical assessments have revealed differing inflammatory responses that affect wound healing and complications. Cyanoacrylate has emerged as a promising alternative to traditional sutures, owing to its rapid polymerization and early healing. However, the choice of suture material in impacted third molar surgery remains controversial, considering microbiological factors and clinical outcomes. More extensive randomized clinical trials are required to better understand the effect of suture materials on surgical outcomes and potential improvements. This study could enhance the safety and effectiveness of this common oral surgical procedure.

10.
J Clin Med ; 12(15)2023 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-37568499

RESUMO

The present pilot study was designed by hypothesizing a possible correlation between lack of accuracy in implant placement and peri-implant hard and soft tissue health. A total of five patients underwent computer-guided implant surgery and full-arch immediate loading between 2013 and 2014. They subsequently underwent postoperative cone-beam computed tomography (CBCT). After a follow-up of 5 years, all patients were recalled for a clinical-radiographic evaluation of peri-implant health status. The mean linear deviation was 0.5 ± 0.2 mm at the implant's head and 0.6 ± 0.2 mm at the implant's apex, while the mean angular deviation of the long axis was 2.8° ± 1.2°. A mean marginal bone loss (MBL) of 1.16 ± 0.94 mm and 2.01 ± 1.76 mm was observed after 1 and 5 years of follow-up, respectively. At 5 years, the mean peri-implant probing depth (PPD) was 4.09 ± 1.44 mm, 66.6% of the evaluated implants showed peri-implant bleeding on probing (BOP), keratinized mucosa (KM) was <2 mm in 48.4% of cases, and mucosal recession (REC) ≥ 1 mm was assessed in 45.4% of the included implants. A negative correlation was observed between bucco-palatal/lingual linear inaccuracy and MBL, PPD, BOP, and KM.

11.
J Prosthet Dent ; 2023 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-37423787

RESUMO

STATEMENT OF PROBLEM: Titanium has been considered the standard element in implant manufacturing. Recent studies have evaluated the role of titanium as a biological modulator of oral health. However, evidence regarding the association between the release of metal particles and peri-implantitis is lacking. PURPOSE: The purpose of this scoping review was to evaluate the literature regarding the release of metal particles in peri-implant tissues correlated with the methods of detection and the local and systemic implications. MATERIAL AND METHODS: The study was performed in adherence with the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines and was registered with the National Institute for Health Research PROSPERO (Submission No. 275576; ID: CRD42021275576). A systematic search was conducted in the Cochrane Central Register of Controlled Trials, EMBASE, MEDLINE via PubMed, Scopus, and Web of Science bibliographic databases, complemented by a manual evaluation. Only in vivo human studies written in the English language and published between January 2000 and June 2022 were included. RESULTS: In total, 10 studies were included according to eligibility criteria. Different tissues and analytic techniques were reported: the characterization technique most used was inductively coupled plasma mass spectrometry. All 10 studies analyzed the release of metal particles in patients with dental implants, continuously detecting titanium. None of the studies reported a significant association between metal particles and biological effects. CONCLUSIONS: Titanium is still considered the material of choice in implant dentistry, despite the detection of metal particles in peri-implant tissues. Further studies are necessary to evaluate the association between analytes and local health or inflammatory status.

12.
Int J Implant Dent ; 9(1): 10, 2023 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-37043147

RESUMO

PURPOSE: The aim of the present study was to evaluate the long-term effectiveness of a xenogeneic collagen matrix (CM) in pre-prosthetic augmentation of the keratinized mucosa width (KMW) at implant sites. METHODS: All of the patients with localized implant-supported rehabilitation previously treated with vestibuloplasty and KMW augmentation with a non-cross-linked porcine CM were recalled. KMW was measured clinically in an apico-coronal direction from the mucogingival junction to the mucosal margin at the prosthetic zenith of each crown. Measurements were performed clinically by means of a PCP-UNC15 periodontal probe and rounded to the nearest mm. KMW values recorded at 1 year, 5 and 10 years from the soft tissue augmentation procedure were compared using a one-way repeated-measures ANOVA with Bonferroni multiple comparison post-hoc analysis. The level of significance was set at 0.05. RESULTS: Measurements were conducted on 13 patients. All implants were in function with no signs of biological complications. All except one implant site showed KMW ≥ 2 mm. KMW decreased significantly from 1 year (3.33 ± 1.11 mm) to 5 years (2.77 ± 0.92 mm) (p = 0.001), and finally remained stable from 5 to 10 years (3.2 ± 0.99 mm) (p = 0.607). From a visual aspect, peri-implant soft tissues were characterized by a good texture and color blending compared to the adjacent teeth, highlighting good integration of the remodeled tissues and stability of the esthetic result. CONCLUSIONS: The use of a CM in pre-prosthetic soft tissue augmentation at implant sites has proven to be effective in obtaining and maintaining at least 2 mm of KMW around dental implants over a follow-up of 10 years.


Assuntos
Implantes Dentários , Animais , Suínos , Estudos Prospectivos , Seguimentos , Estética Dentária , Mucosa , Colágeno/uso terapêutico
13.
J Oral Implantol ; 2022 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-36473182

RESUMO

The aim of the present study was to analyze the survival and success rates of dental implants placed in atrophic alveolar ridges reconstructed with mandibular symphysis autogenous onlay bone grafts, with a 20-year follow-up. A sample of five patients referred to the authors' department between 2000 and 2001 seeking for an implant-supported fixed rehabilitation. Patients were treated by means of autogenous bone blocks grafted from the mandibular symphysis and covered with bone substitutes (DBB) and a resorbable membrane. Then delayed implants were placed and finally prosthetic restoration was performed. In total, 10 implants placed in 5 patients were evaluated with a follow-up of 20 years. Both implant survival and success rate were 100%. The mean marginal bone loss was 0.32  [[EQUATION]]  0.39 mm (range 0-1.3 mm). Considering the conditions of peri-implant hard and soft tissues, the diagnosis of peri-implant health was made for all the implants included. According to this study, implants placed in alveolar ridges augmented by means of autogenous chin bone grafts showed long-term survival and high success rates. A correct management of peri-implant soft tissues and an accurate prosthetic rehabilitation are also fundamental to obtain the durable success of the treatment.

14.
Materials (Basel) ; 15(13)2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35806496

RESUMO

(1) Background: This study evaluates the effects of photobiomodulation (PBM) therapy on the peri-implant bone healing of implants with a machined surface (MS) and treated surface (TS). (2) Methods: Topographic characterization of the surfaces (scanning electron microscopy [SEM]- energy dispersive X-ray spectroscopy [EDX]) was performed before and after implant removal. Twenty rabbits were randomly divided into four groups: MS and TS groups (without PBM therapy) and LMS and LTS groups (with PBM therapy). After implant placement, the stability coefficient (ISQ) was measured. In the periods of 21 and 42 days, the ISQ was measured again, followed by biomechanical analysis. (3) Results: The surfaces of the TS implants showed topographic differences compared with MS implants. The ISQ values of the LMS were statistically significant when compared with those of the MS at 42 days (p < 0.001). The removal torque values of the LMS were statistically significant when compared with those of the MS at 21 days (p = 0.023) and 42 days (p = 0.023). For SEM, in general, the LMS, TS and LTS presented high bone tissue coverage when compared to MS. (4) Conclusions: The PBM therapy modulated the osseointegration process and was evidenced mainly on the machined surface.

15.
Case Rep Dent ; 2022: 6210289, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35548385

RESUMO

Odontoma is the most common benign odontogenic tumor of epithelial and mesenchymal origin. The standard treatment involves a conservative approach. While this procedure is generally well accepted and tolerated, some difficulties may arise in case of odontomas associated with cystic lesions. In general, the expansive nature of cystic lesions requires their surgical excision, different from isolated nonsymptomatic odontomas that can be monitored radiographically. However, to the best of our knowledge, there is scarce evidence currently available reporting on the presence of odontoma-associated cystic lesions in the oral cavity. Therefore, the present case report is aimed at describing the diagnostic clinical, radiological, and histological features together with the surgical management of a dentigerous cyst associated with a compound odontoma. Following surgical removal of the lesion, no recurrence was observed after 12 months of follow-up.

16.
Int J Oral Maxillofac Implants ; 37(2): 250-269, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35476854

RESUMO

PURPOSE: The exposure of nonresorbable membranes following alveolar bone augmentation is one of the most frequently occurring complications. This review aimed to investigate the treatments that can be adopted to manage the exposure of polytetrafluoroethylene-based membranes (PTFE-ms) and titanium meshes (TMs) and their outcomes. MATERIALS AND METHODS: Two independent reviewers electronically and manually searched the EMBASE, PubMed/MEDLINE, Scopus, and Cochrane bibliographic databases to retrieve pertinent articles available between January 2000 and March 2021. Only human studies describing the type of treatment and the soft tissue outcome following exposure of PTFE-ms or TMs were included. RESULTS: Overall, 11 articles in the PTFE-ms group and 24 in the TM group were included for data analysis. Results indicated that, in both groups, two distinct therapeutic strategies are mostly applied in case of exposure, namely, pharmacologic and mechanical treatments. Other options have been identified seldomly. Statistically significant evidence of an association between the type of barrier membrane and the exposure rate (28.7% vs 38.5% for TMs and PTFE-ms, respectively; P = .019) and between the type of exposed device and the treatment outcome in terms of removal rate following therapy (11.9% and 44.4% for TMs and PTFE-ms, respectively; P < .001) was noted. CONCLUSION: In both groups, chlorhexidine applications and meticulous plaque control may lead to improved healing conditions after exposure. Surgical removal of the exposed portion can be considered to promote secondary intention healing. The beneficial effects of systemic antibiotics could not be demonstrated in the management of the exposure but should be evaluated in case of graft infection.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Aumento do Rebordo Alveolar/efeitos adversos , Aumento do Rebordo Alveolar/métodos , Regeneração Óssea , Humanos , Politetrafluoretileno , Telas Cirúrgicas/efeitos adversos , Titânio
17.
Materials (Basel) ; 15(3)2022 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-35161027

RESUMO

The success of surgical procedures is strictly related to the biomechanical properties of the suture. Mechanical comparisons are scarcely reported in the literature, so the purpose of the present study was to evaluate and compare the mechanical behavior of different sutures commonly used in oral surgery in terms of traction resistance. Sutures made of eight different materials were analyzed: silk (S), polyglycolide-co-caprolactone (PGCL), polypropylene (PP), rapid polyglycolide (rPGA), standard polyglycolide (PGA), polyamide (PA), polyester (PE), and polyvinylidene fluoride (PVDF). For each material, three different sizes were tested: 3-0, 4-0, and 5-0. The breaking force of each suture was assessed with a uniaxial testing machine after being immersed in artificial saliva at 37 °C. The outcomes analyzed were the breaking force, the needle-thread detachment breaking-point and the node response after forward-reverse-forward (FRF) tying when subjected to a tensile force. The 3-0 rPGA provided the maximum resistance, while the lowest value was recorded for the 5-0 PGCL. In general, 3-0 and 4-0 gauges showed non-statistically significant differences in terms of needle-thread detachment. The highest needle-thread detachment was found for the 3-0 PGA, whereas the lowest value was observed for the 5-0 PGCL. After tying the knot with an FRF configuration, the thread that showed the highest resistance to tension was the 3/0 silk, while the thread with the lowest resistance was the 5/0 silk. These data should be considered so that the operator is aware of as many aspects as possible on the behavior of various materials to ensure successful healing.

18.
J Oral Maxillofac Surg ; 80(1): 37.e1-37.e12, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34656515

RESUMO

PURPOSE: Laser light has biological effects that can modulate inflammatory processes. Thus, this study aimed to evaluate the effects of photobiomodulation (PBM) therapy on pain, edema, and trismus after the extraction of retained third molars. METHODS: A split-mouth, double-blind, randomized clinical trial (RCT) was conducted in 13 patients with similar bilateral third molars who received intraoral application PBM therapy at 4 points with a diode laser at 810 nm wavelength, 6 J (100 mW, 60 seconds/point) on 1 side (the PBM side); and laser irradiation simulation on the other side (SHAM side). The pain was assessed through visual analog scale (VAS) at 0, 12, 24, 48, and 72 hours, number of analgesic-relief (NAR), and mean time of first analgesic use; edema, through VAS, and linear facial measurements at 0, 24, 48, and 72 hours; and trismus, through the mouth opening measurements at 0, 24, 48, and 72 hours. The repeated-measures analysis was applied to assess the effect of the treatment, followed by Tukey's post hoc test for multiple comparisons (P < .05). RESULTS: Thirteen patients (61.77% male and 38.63% female) with age of 24.16 ± 2.06 participated in this research. VAS showed that PBM controlled pain better (7.56 ± 6.25) than SHAM (32.25 ± 22.78) at 24 hours (P < .001) and 48 hours (19.47 ± 9.27 and 39.87 ± 4.21, respectively) (P = .011). VAS also showed that PBM controlled edema better (19.7 ± 13.27) than SHAM (32.38 ± 15.28) at 24 hours (P = .037) and 48 hours (19.47 ± 13.11 and 39.87 ± 22.77, respectively) (P = .002). CONCLUSION: The PBM therapy in this study resulted in pain and edema reduction after third molar surgery and may be considered as adjuvant therapy after the surgical procedure.


Assuntos
Terapia com Luz de Baixa Intensidade , Dente Impactado , Método Duplo-Cego , Edema/etiologia , Edema/terapia , Feminino , Humanos , Masculino , Dente Serotino/cirurgia , Dor Pós-Operatória/terapia , Extração Dentária , Dente Impactado/cirurgia , Trismo/terapia
19.
Photodiagnosis Photodyn Ther ; 37: 102598, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34699984

RESUMO

BACKGROUND: Antimicrobial photodynamic therapy (aPDT) is used in endodontics to improve orthograde root canal disinfection as an adjunct to standard treatments. Conversely, evidence concerning the application of aPDT in retrograde endodontic surgery is limited. Thus, the aim of the present study was to provide additional data regarding the use of aPDT in the surgical endodontic treatment of periapical lesions. METHODS: A total of 25 consecutive patients presenting teeth with periapical radiolucency eventually associated with clinical signs and symptoms of apical periodontitis were included. Following access flap completion, osteotomy, mechanical debridement, root apical third resection, and preparation of the root-end cavity, aPDT was applied to decontaminate the surgical site using phenothiazine chloride dye at a concentration of 10 mg/mL and irradiation with a hand-held 100-mW diode laser with a wavelength of 660 ± 10 nm. At the latest follow-up visit, healing was evaluated as successful, uncertain, or failure according to well-established clinical and radiological criteria. RESULTS: Overall, 31 periapical lesions were treated with aPDT. Healing proceeded uneventfully. The mean follow-up time was 36.19 months, with times ranging from 12 to 85 months. A total of 25 (80.65%) cases were classified as successful, 5 (16.13%) as uncertain, and only one (3.22%) as failure. Irrespective of the treatment outcome, all treated teeth were still functional, with no symptoms reported by the patients. CONCLUSION: aPDT as an adjunctive treatment modality in the surgical endodontic treatment of periapical lesions showed promising medium-term results associated with preservation of all diseased teeth.


Assuntos
Anti-Infecciosos , Periodontite Periapical , Fotoquimioterapia , Antibacterianos/uso terapêutico , Anti-Infecciosos/uso terapêutico , Humanos , Periodontite Periapical/tratamento farmacológico , Periodontite Periapical/cirurgia , Fotoquimioterapia/métodos , Tratamento do Canal Radicular/métodos
20.
J Clin Med ; 10(23)2021 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-34884228

RESUMO

OBJECTIVES: A wide variety of approaches have been proposed to manage anticoagulant drugs in patients undergoing dental surgery; vitamin K antagonists and novel direct oral anticoagulants have been used. The present study aims to explore the existing evidence concerning the management of patients in anticoagulant therapy undergoing oral surgery procedures and to give suggestions related to peri- and post-operative measures. MATERIALS AND METHODS: A comprehensive search of databases was conducted to identify studies that evaluated the relationship between direct oral anticoagulants and dental procedures. The present scoping review was realized in adherence with the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) guidelines. The publications varied from randomized controlled trials (RCT) to cohort trials. Only articles written in English language and published between 2000 to 2020 were screened. The studies were included if discussing the management of a patient in anticoagulant therapy (warfarin or direct oral anticoagulants) scheduled for tooth extraction. RESULTS: 33 studies were selected and included in the qualitative review. Nineteen considered anticoagulant therapy with warfarin, six considered anticoagulant therapy with new oral anticoagulants and eight compared patients taking warfarin with patients taking direct oral anticoagulants. CONCLUSIONS: No case of extractive surgery should alter the posology of the drug: thromboembolic risks derived from discontinuation are heavier than hemorrhagic risks. CLINICAL RELEVANCE: direct oral anticoagulants are safer in terms of bleeding and manageability and bleeding episodes are manageable with local hemostatic measures.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA