Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Graefes Arch Clin Exp Ophthalmol ; 258(5): 1073-1079, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32036425

RESUMO

PURPOSE: This study evaluates the 6-month safety and efficacy of micropulse transscleral cyclophotocoagulation (MP-TSCPC) in cases of uncontrolled glaucoma/ocular hypertension using a reduced energy protocol. METHODS: Retrospective analysis of patients undergoing MP-TSCPC from January-April 2018 was carried out. Patients received up to 90 s of laser with settings of 2000 mW/Cm2 and a duty cycle of 31.3%. RESULTS: A total of 29 patients were included, with a mean age of 64.7 ± 15.1 years. The most common diagnosis was primary open angle glaucoma (41.4%) with a mean Logmar visual acuity of 1.5 ± 1.2. All subjects had either undergone intraocular surgery (58.6% filtration surgery) or continuous wave diode laser prior to micropulse treatment. Mean pre-laser IOP was 26.2 ± 11.1 mmHg. There was a significant reduction (p < 0.05) in IOP at 1 month to 15.8 ± 5.4 mmHg (39.7% reduction), at 3 months to 15.04 ± 5.25 mmHg (42.6% reduction) and at 6 months to 18.19 ± 7.47 mmHg (30.6% reduction). There was also a corresponding reduction (p < 0.05) in the number of topical agents required to control pressure from a baseline of 3.31 ± 0.97, to 2.72 ± 0.88 at 1 month, 2.76 ± 0.91 at 3 months and 2.90 ± 1.08 at 6 months. Requirements for oral acetazolamide reduced from 41.3% (1/29) at baseline to 3.4% (1/29) at 6 months. Success rates were 75.9% at 1 month, 79.3% at 3 months and 58.6% at 6 months. There was no drop in the visual acuity, no change in central retinal thickness and no cases of intraocular inflammation. CONCLUSIONS: MP-TSCPC at a decreased duration is effective at reducing intraocular pressure in ethnically diverse glaucoma patients refractory to previous glaucoma laser or surgeries at 6 months follow-up, with no significant complications. Further work is needed to confirm efficacy in the long term and to determine optimal settings.


Assuntos
Corpo Ciliar/cirurgia , Glaucoma de Ângulo Aberto/cirurgia , Fotocoagulação a Laser/métodos , Lasers Semicondutores/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Feminino , Glaucoma de Ângulo Aberto/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Hipertensão Ocular/cirurgia , Prognóstico , Estudos Retrospectivos , Esclera/cirurgia , Tonometria Ocular , Acuidade Visual/fisiologia
2.
Eye (Lond) ; 34(11): 2082-2088, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31996840

RESUMO

OBJECTIVE: To ascertain visual and refractive outcomes following toric intraocular lens (IOL) implantation in the UK National Health Service (NHS) without posterior corneal astigmatism calculation, with multiple surgeons of different grades, pooled input and output pathways and autorefraction as the refractive outcome measure. METHODS: Preoperative and 1-month post-operative data were analysed retrospectively in 114 eyes (95 patients) receiving a toric IOL between 2014 and 2016 at Imperial College NHS Trust. Preoperative keratometric astigmatism was ≥2 dioptres (D). RESULTS: Mean preoperative best-corrected visual acuity (BCVA) was 0.50 logMAR (±0.46), improving to a mean uncorrected VA (UCVA) of 0.35 logMAR (±0.36) postoperatively (p < 0.001) with 65% of eyes attaining a UCVA ≤ 0.30 logMAR. Excluding 33 eyes with pre-existing visual comorbidities and one targeting monovision, mean post-operative UCVA was 0.24 logMAR (±0.29) (p < 0.001), and 85% had UCVA ≤ 0.30 logMAR, 62% UCVA ≤ 0.20 logMAR. Mean refractive astigmatism improved from 3.04 D (±1.46) to 1.36 D (±1.13) (p < 0.001). In total, 52% of eyes had post-operative refractive astigmatism ≤1.00 D. The Alpins correction index was 1.05 (±0.22), indicating a tendency to overcorrect. Toric IOL misalignment was noted in two eyes, and two cases of posterior capsule rupture were converted to a non-toric IOL. CONCLUSIONS: Visual outcomes of toric IOL implantation in our pooled pathway are comparable to single-surgeon case series where posterior corneal astigmatism has not been accounted for. However, with 1-month post-operative autorefraction, only 52% of eyes had ≤1 D refractive astigmatism, which is lower than previously published series, but may be standard for 1-month autorefraction outcomes.


Assuntos
Astigmatismo , Lentes Intraoculares , Facoemulsificação , Astigmatismo/cirurgia , Humanos , Implante de Lente Intraocular , Refração Ocular , Estudos Retrospectivos , Medicina Estatal , Reino Unido , Acuidade Visual
3.
BMC Ophthalmol ; 18(Suppl 1): 219, 2018 Sep 14.
Artigo em Inglês | MEDLINE | ID: mdl-30255821

RESUMO

BACKGROUND: This case highlights the important sequelae that can occur following the inadvertent implantation of a single-piece intraocular lens into the ciliary sulcus during cataract surgery; secondary pigment dispersion glaucoma, recurrent anterior uveitis and macular oedema. CASE PRESENTATION: A 67-year-old lady underwent routine left cataract surgery in a separate unit but subsequently attended our eye casualty with recurrent hypertensive anterior uveitis. She was found to have secondary pigment dispersion glaucoma as the intraocular lens had been inadvertently placed into the ciliary sulcus. She underwent a trabeculectomy to control the intraocular pressure and initially settled well but 12 months later developed persistent anterior segment inflammation and macular oedema. She subsequently had the intraocular lens removed and the macular oedema was treated successfully with intravitreal Bevacizumab. CONCLUSIONS: We provide a summary of the evidence and a discussion over the management options available in managing such a difficult case.


Assuntos
Corpo Ciliar/lesões , Síndrome de Exfoliação/etiologia , Traumatismos Oculares/etiologia , Glaucoma de Ângulo Aberto/etiologia , Implante de Lente Intraocular/efeitos adversos , Edema Macular/etiologia , Uveíte Anterior/etiologia , Idoso , Inibidores da Angiogênese/uso terapêutico , Bevacizumab/uso terapêutico , Remoção de Dispositivo , Síndrome de Exfoliação/diagnóstico , Síndrome de Exfoliação/cirurgia , Feminino , Glaucoma de Ângulo Aberto/diagnóstico , Glaucoma de Ângulo Aberto/cirurgia , Humanos , Pressão Intraocular/fisiologia , Lentes Intraoculares , Edema Macular/diagnóstico , Edema Macular/tratamento farmacológico , Facoemulsificação , Recidiva , Tomografia de Coerência Óptica , Trabeculectomia , Uveíte Anterior/diagnóstico , Uveíte Anterior/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA