Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Eur Radiol Exp ; 8(1): 71, 2024 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-38880866

RESUMO

BACKGROUND: Radiomics is a quantitative approach that allows the extraction of mineable data from medical images. Despite the growing clinical interest, radiomics studies are affected by variability stemming from analysis choices. We aimed to investigate the agreement between two open-source radiomics software for both contrast-enhanced computed tomography (CT) and contrast-enhanced magnetic resonance imaging (MRI) of lung cancers and to preliminarily evaluate the existence of radiomic features stable for both techniques. METHODS: Contrast-enhanced CT and MRI images of 35 patients affected with non-small cell lung cancer (NSCLC) were manually segmented and preprocessed using three different methods. Sixty-six Image Biomarker Standardisation Initiative-compliant features common to the considered platforms, PyRadiomics and LIFEx, were extracted. The correlation among features with the same mathematical definition was analyzed by comparing PyRadiomics and LIFEx (at fixed imaging technique), and MRI with CT results (for the same software). RESULTS: When assessing the agreement between LIFEx and PyRadiomics across the considered resampling, the maximum statistically significant correlations were observed to be 94% for CT features and 95% for MRI ones. When examining the correlation between features extracted from contrast-enhanced CT and MRI using the same software, higher significant correspondences were identified in 11% of features for both software. CONCLUSIONS: Considering NSCLC, (i) for both imaging techniques, LIFEx and PyRadiomics agreed on average for 90% of features, with MRI being more affected by resampling and (ii) CT and MRI contained mostly non-redundant information, but there are shape features and, more importantly, texture features that can be singled out by both techniques. RELEVANCE STATEMENT: Identifying and selecting features that are stable cross-modalities may be one of the strategies to pave the way for radiomics clinical translation. KEY POINTS: • More than 90% of LIFEx and PyRadiomics features contain the same information. • Ten percent of features (shape, texture) are stable among contrast-enhanced CT and MRI. • Software compliance and cross-modalities stability features are impacted by the resampling method.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Imageamento por Ressonância Magnética , Software , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Meios de Contraste , Radiômica
2.
Sci Rep ; 14(1): 418, 2024 01 03.
Artigo em Inglês | MEDLINE | ID: mdl-38172585

RESUMO

Boron Neutron Capture Therapy (BNCT) is a radiotherapy technique based on the enrichment of tumour cells with suitable 10-boron concentration and on subsequent neutron irradiation. Low-energy neutron irradiation produces a localized deposition of radiation dose caused by boron neutron capture reactions. Boron is vehiculated into tumour cells via proper borated formulations, able to accumulate in the malignancy more than in normal tissues. The neutron capture releases two high-LET charged particles (i.e., an alpha particle and a lithium ion), losing their energy in a distance comparable to the average dimension of one cell. Thus BNCT is selective at the cell level and characterized by high biological effectiveness. As the radiation field is due to the interaction of neutrons with the components of biological tissues and with boron, the dosimetry requires a formalism to express the absorbed dose into photon-equivalent units. This work analyzes a clinical case of an adenoid cystic carcinoma treated with carbon-ion radiotherapy (CIRT), located close to optic nerve and deep-seated as a practical example of how to apply the formalism of BNCT photon isoeffective dose and how to evaluate the BNCT dose distribution against CIRT. The example allows presenting different dosimetrical and radiobiological quantities and drawing conclusions on the potential of BNCT stemming on the clinical result of the CIRT. The patient received CIRT with a dose constraint on the optic nerve, affecting the peripheral part of the Planning Target Volume (PTV). After the treatment, the tumour recurred in this low-dose region. BNCT was simulated for the primary tumour, with the goal to calculate the dose distribution in isoeffective units and a Tumour Control Probability (TCP) to be compared with the one of the original treatment. BNCT was then evaluated for the recurrence in the underdosed region which was not optimally covered by charged particles due to the proximity of the optic nerve. Finally, a combined treatment consisting in BNCT and carbon ion therapy was considered to show the consistency and the potential of the model. For the primary tumour, the photon isoeffective dose distribution due to BNCT was evaluated and the resulted TCP was higher than that obtained for the CIRT. The formalism produced values that are consistent with those of carbon-ion. For the recurrence, BNCT dosimetry produces a similar TCP than that of primary tumour. A combined treatment was finally simulated, showing a TCP comparable to the BNCT-alone with overall dosimetric advantage in the most peripheral parts of the treatment volume. Isoeffective dose formalism is a robust tool to analyze BNCT dosimetry and to compare it with the photon-equivalent dose calculated for carbon-ion treatment. This study introduces for the first time the possibility to combine the dosimetry obtained by two different treatment modalities, showing the potential of exploiting the cellular targeting of BNCT combined with the precision of charged particles in delivering an homogeneous dose distribution in deep-seated tumours.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço , Radioterapia com Íons Pesados , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Boro , Carbono , Nêutrons
3.
Eur Phys J Plus ; 138(4): 326, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064789

RESUMO

Computed tomography (CT) scans are used to evaluate the severity of lung involvement in patients affected by COVID-19 pneumonia. Here, we present an improved version of the LungQuant automatic segmentation software (LungQuant v2), which implements a cascade of three deep neural networks (DNNs) to segment the lungs and the lung lesions associated with COVID-19 pneumonia. The first network (BB-net) defines a bounding box enclosing the lungs, the second one (U-net 1 ) outputs the mask of the lungs, and the final one (U-net 2 ) generates the mask of the COVID-19 lesions. With respect to the previous version (LungQuant v1), three main improvements are introduced: the BB-net, a new term in the loss function in the U-net for lesion segmentation and a post-processing procedure to separate the right and left lungs. The three DNNs were optimized, trained and tested on publicly available CT scans. We evaluated the system segmentation capability on an independent test set consisting of ten fully annotated CT scans, the COVID-19-CT-Seg benchmark dataset. The test performances are reported by means of the volumetric dice similarity coefficient (vDSC) and the surface dice similarity coefficient (sDSC) between the reference and the segmented objects. LungQuant v2 achieves a vDSC (sDSC) equal to 0.96 ± 0.01 (0.97 ± 0.01) and 0.69 ± 0.08 (0.83 ± 0.07) for the lung and lesion segmentations, respectively. The output of the segmentation software was then used to assess the percentage of infected lungs, obtaining a Mean Absolute Error (MAE) equal to 2%.

4.
J Biomed Mater Res B Appl Biomater ; 111(8): 1571-1580, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37014107

RESUMO

Osteosarcoma is the most frequently primary malignant bone tumor characterized by infiltrative growth responsible for relapses and metastases. Treatment options are limited, and a new therapeutic option is required. Boron neutron capture therapy (BNCT) is an experimental alternative radiotherapy able to kill infiltrative tumor cells spearing surrounding healthy tissues. BNCT studies are performed on 2D in vitro models that are not able to reproduce pathological tumor tissue organization or on in vivo animal models that are expensive, time-consuming and must follow the 3R's principles. A 3D in vitro model is a solution to better recapitulate the complexity of solid tumors meanwhile limiting the animal's use. Objective of this study is to optimize the technical assessment for developing a 3D in vitro osteosarcoma model as a platform for BNCT studies: printing protocol, biomaterial selection, cell density, and crosslinking process. The best parameters that allow a fully colonized 3D bioprinted construct by rat osteosarcoma cell line UMR-106 are 6 × 106 cells/ml of hydrogel and 1% CaCl2 as a crosslinking agent. The proposed model could be an alternative or a parallel approach to 2D in vitro culture and in vivo animal models for BNCT experimental study.


Assuntos
Neoplasias Ósseas , Terapia por Captura de Nêutron de Boro , Osteossarcoma , Ratos , Animais , Compostos de Boro , Terapia por Captura de Nêutron de Boro/métodos , Osteossarcoma/radioterapia , Osteossarcoma/tratamento farmacológico , Linhagem Celular Tumoral , Neoplasias Ósseas/radioterapia , Neoplasias Ósseas/tratamento farmacológico
5.
Eur Radiol Exp ; 7(1): 18, 2023 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-37032383

RESUMO

BACKGROUND: The role of computed tomography (CT) in the diagnosis and characterization of coronavirus disease 2019 (COVID-19) pneumonia has been widely recognized. We evaluated the performance of a software for quantitative analysis of chest CT, the LungQuant system, by comparing its results with independent visual evaluations by a group of 14 clinical experts. The aim of this work is to evaluate the ability of the automated tool to extract quantitative information from lung CT, relevant for the design of a diagnosis support model. METHODS: LungQuant segments both the lungs and lesions associated with COVID-19 pneumonia (ground-glass opacities and consolidations) and computes derived quantities corresponding to qualitative characteristics used to clinically assess COVID-19 lesions. The comparison was carried out on 120 publicly available CT scans of patients affected by COVID-19 pneumonia. Scans were scored for four qualitative metrics: percentage of lung involvement, type of lesion, and two disease distribution scores. We evaluated the agreement between the LungQuant output and the visual assessments through receiver operating characteristics area under the curve (AUC) analysis and by fitting a nonlinear regression model. RESULTS: Despite the rather large heterogeneity in the qualitative labels assigned by the clinical experts for each metric, we found good agreement on the metrics compared to the LungQuant output. The AUC values obtained for the four qualitative metrics were 0.98, 0.85, 0.90, and 0.81. CONCLUSIONS: Visual clinical evaluation could be complemented and supported by computer-aided quantification, whose values match the average evaluation of several independent clinical experts. KEY POINTS: We conducted a multicenter evaluation of the deep learning-based LungQuant automated software. We translated qualitative assessments into quantifiable metrics to characterize coronavirus disease 2019 (COVID-19) pneumonia lesions. Comparing the software output to the clinical evaluations, results were satisfactory despite heterogeneity of the clinical evaluations. An automatic quantification tool may contribute to improve the clinical workflow of COVID-19 pneumonia.


Assuntos
COVID-19 , Aprendizado Profundo , Pneumonia , Humanos , SARS-CoV-2 , Pulmão/diagnóstico por imagem , Software
6.
Life (Basel) ; 13(2)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36836786

RESUMO

Inorganic nanoparticles of boron-rich compounds represent an attractive alternative to boron-containing molecules, such as boronophenylalanine or boranes, for BNCT applications. This work describes the synthesis and biological activity of multifunctional boron carbide nanoparticles stabilized with polyacrylic acid (PAA) and a gadolinium (Gd)-rich solid phase. A fluorophore (DiI) was included in the PAA functionalization, allowing the confocal microscopy imaging of the nanoparticles. Analysis of the interaction and activity of these fluorescent Gd-containing B4C nanoparticles (FGdBNPs) with cultured cells was appraised using an innovative correlative microscopy approach combining intracellular neutron autoradiography, confocal, and SEM imaging. This new approach allows visualizing the cells, the FGdBNP, and the events deriving from the nuclear process in the same image. Quantification of 10B by neutron autoradiography in cells treated with FGdBNPs confirmed a significant accumulation of NPs with low levels of cellular toxicity. These results suggest that these NPs might represent a valuable tool for achieving a high boron concentration in tumoral cells.

7.
Radiat Res ; 198(2): 134-144, 2022 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-35504003

RESUMO

Boron neutron capture therapy (BNCT) is a treatment modality for cancer that involves radiations of different qualities. A formalism that proved suitable to compute doses in photon-equivalent units is the photon isoeffective dose model. This study addresses the question whether considering in vitro or in vivo radiobiological studies to determine the parameters involved in photon isoeffective dose calculations affects the consistency of the model predictions. The analysis is focused on head and neck squamous cell carcinomas (HNSCC), a main target that proved to respond to BNCT. The photon isoeffective dose model for HNSCC with parameters from in vitro studies using the primary human cell line UT-SCC-16A was introduced and compared to the one previously reported with parameters from an in vivo oral cancer model in rodents. Both models were first compared in a simple scenario by means of tumor dose and control probability calculations. Then, the clinical impact of the different dose models was assessed from the analysis of a group of squamous cell carcinomas (SCC) patients treated with BNCT. Traditional dose calculations using the relative biological effectiveness factors derived from the SCC cell line were also analyzed. Predictions of tumor control from the evaluated models were compared to the patients' outcome. The quantification of the biological effectiveness of the different radiations revealed that relative biological effectiveness/compound biological effectiveness (RBE/CBE) factors for the SCC cell line are up to 20% higher than those assumed in clinical BNCT, highlighting the importance of using experimental data intimately linked to the tumor type to derive the model's parameters. The comparison of the different models showed that photon isoeffective doses based on in vitro data are generally greater than those from in vivo data (∼8-16% for total tumor absorbed doses of 10-15 Gy). However, the predictive power of the two models was not affected by these differences: both models fulfilled conditions to guarantee a good predictive performance and gave predictions statistically compatible with the clinical outcome. On the other hand, doses computed with the traditional model were substantially larger than those obtained with both photon isoeffective models. Moreover, the traditional model is statistically rejected, which reinforces the assertion that its inconsistencies are intrinsic and not due to the use of RBE/CBE factors obtained for a tumor type different from HN cancer. The results suggest that the nature of the radiobiological data would not affect the consistency of the photon isoeffective dose model in the studied cases of SCC head and neck cancer treated with BPA-based BNCT.


Assuntos
Terapia por Captura de Nêutron de Boro , Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Terapia por Captura de Nêutron de Boro/métodos , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/radioterapia , Humanos , Fótons/uso terapêutico , Eficiência Biológica Relativa , Carcinoma de Células Escamosas de Cabeça e Pescoço
8.
Phys Med ; 94: 75-84, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34999515

RESUMO

PURPOSE: One of the obstacles to the application of Boron Neutron Capture Therapy (BNCT) and Proton Boron Fusion Therapy (PBFT) concerns the measurement of borated carriers' biodistribution. The objective of the present study was to evaluate the in vitro internalization of the 19F-labelled p-boronophenylalanine (19F-BPA) in the human cancer pancreatic cell line (PANC-1) for the potential application of BNCT and PBFT in pancreatic cancer. The 19F-BPA carrier has the advantage that its bio-distribution may be monitored in vivo using 19F-Nuclear Magnetic Resonance (19F NMR). MATERIALS AND METHODS: The 19F-BPA internalization in PANC-1 cells was evaluated using three independent techniques on cellular samples left in contact with growing medium enriched with 13.6 mM 19F-BPA corresponding to a 11B concentration of 120 ppm: neutron autoradiography, which quantifies boron; liquid chromatography hyphenated to tandem mass spectrometry and UV-Diode Array Detection (UV-DAD), which quantifies 19F-BPA molecule; and 19F NMR spectroscopy, which detects fluorine nuclei. RESULTS: Our studies suggested that 19F-BPA is internalized by PANC-1 cells. The three methods provided consistent results of about 50% internalization fraction at 120 ppm of 11B. Small variations (less than 15%) in internalization fraction are mainly dependent on the proliferation state of the cells. CONCLUSIONS: The ability of 19F NMR spectroscopy to study 19F-BPA internalization was validated by well-established independent techniques. The multimodal approach we used suggests 19F-BPA as a promising BNCT/PBFT carrier for the treatment of pancreatic cancer. Since the quantification is performed at doses useful for BNCT/PBFT, 19F NMR can be envisaged to monitor 19F-BPA bio-distribution during the therapy.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias Pancreáticas , Terapia com Prótons , Boro , Compostos de Boro , Humanos , Neoplasias Pancreáticas/radioterapia , Distribuição Tecidual
9.
Int J Comput Assist Radiol Surg ; 17(2): 229-237, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34698988

RESUMO

PURPOSE: This study aims at exploiting artificial intelligence (AI) for the identification, segmentation and quantification of COVID-19 pulmonary lesions. The limited data availability and the annotation quality are relevant factors in training AI-methods. We investigated the effects of using multiple datasets, heterogeneously populated and annotated according to different criteria. METHODS: We developed an automated analysis pipeline, the LungQuant system, based on a cascade of two U-nets. The first one (U-net[Formula: see text]) is devoted to the identification of the lung parenchyma; the second one (U-net[Formula: see text]) acts on a bounding box enclosing the segmented lungs to identify the areas affected by COVID-19 lesions. Different public datasets were used to train the U-nets and to evaluate their segmentation performances, which have been quantified in terms of the Dice Similarity Coefficients. The accuracy in predicting the CT-Severity Score (CT-SS) of the LungQuant system has been also evaluated. RESULTS: Both the volumetric DSC (vDSC) and the accuracy showed a dependency on the annotation quality of the released data samples. On an independent dataset (COVID-19-CT-Seg), both the vDSC and the surface DSC (sDSC) were measured between the masks predicted by LungQuant system and the reference ones. The vDSC (sDSC) values of 0.95±0.01 and 0.66±0.13 (0.95±0.02 and 0.76±0.18, with 5 mm tolerance) were obtained for the segmentation of lungs and COVID-19 lesions, respectively. The system achieved an accuracy of 90% in CT-SS identification on this benchmark dataset. CONCLUSION: We analysed the impact of using data samples with different annotation criteria in training an AI-based quantification system for pulmonary involvement in COVID-19 pneumonia. In terms of vDSC measures, the U-net segmentation strongly depends on the quality of the lesion annotations. Nevertheless, the CT-SS can be accurately predicted on independent test sets, demonstrating the satisfactory generalization ability of the LungQuant.


Assuntos
Inteligência Artificial , COVID-19 , Humanos , Pulmão/diagnóstico por imagem , SARS-CoV-2 , Tórax
10.
Phys Med ; 89: 282-292, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34474326

RESUMO

PURPOSE: Boron Neutron Capture Therapy (BNCT) is a form of hadrontherapy based on the selective damage caused by the products of neutron capture in 10B to tumour cells. BNCT dosimetry strongly depends on the parameters of the dose calculation models derived from radiobiological experiments. This works aims at determining an adequate dosimetry for in-vitro experiments involving irradiation of monolayer-cultured cells with photons and BNCT and assessing its impact on clinical settings. M&M: Dose calculations for rat osteosarcoma UMR-106 and human metastatic melanoma Mel-J cell survival experiments were performed using MCNP, transporting uncharged particles for KERMA determinations, and secondary particles (electrons, protons, 14C, 4He and 7Li) to compute absorbed dose in cultures. Dose-survival curves were modified according to the dose correction factors determined from computational studies. New radiobiological parameters of the photon isoeffective dose models for osteosarcoma and metastatic melanoma tumours were obtained. Dosimetry implications considering cutaneous melanoma patients treated in Argentina with BNCT were assessed and discussed. RESULTS: KERMA values for the monolayer-cultured cells overestimate absorbed doses of radiation components of interest in BNCT. Detailed dose calculations for the osteosarcoma irradiation increased the relative biological effectiveness factor RBE1% of the neutron component in more than 30%. The analysis based on melanoma cases reveals that the use of survival curves based on KERMA leads to an underestimation of the tumour doses delivered to patients. CONCLUSIONS: Considering detailed dose calculation for in-vitro experiments significantly impact on the prediction of the tumor control in patients. Therefore, proposed methods are clinically relevant.


Assuntos
Terapia por Captura de Nêutron de Boro , Melanoma , Neoplasias Cutâneas , Animais , Humanos , Masculino , Melanoma/radioterapia , Radiometria , Ratos , Eficiência Biológica Relativa
11.
Biology (Basel) ; 10(3)2021 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-33652642

RESUMO

(1) Background:The quality of neutron beams for Boron Neutron Capture Therapy (BNCT) is currently defined by its physical characteristics in air. Recommendations exist to define whether a designed beam is useful for clinical treatment. This work presents a new way to evaluate neutron beams based on their clinical performance and on their safety, employing radiobiological quantities. (2) Methods: The case study is a neutron beam for deep-seated tumors from a 5 MeV proton beam coupled to a beryllium target. Physical Figures of Merit were used to design five beams; however, they did not allow a clear ranking of their quality in terms of therapeutic potential. The latter was then evaluated based on in-phantom dose distributions and on the calculation of the Uncomplicated Tumor Control Probability (UTCP). The safety of the beams was also evaluated calculating the in-patient out-of-beam dosimetry. (3) Results: All the beams ensured a UTCP comparable to the one of a clinical beam in phantom; the safety criterion allowed to choose the best candidate. When this was tested in the treatment planning of a real patient treated in Finland, the UTCP was still comparable to the one of the clinical beam. (4) Conclusions: Even when standard physical recommendations are not met, radiobiological and dosimetric criteria demonstrate to be a valid tool to select an effective and safe beam for patient treatment.

12.
Adv Healthc Mater ; 10(6): e2001632, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33369251

RESUMO

The combination of multiple functions in a single nanoparticle (NP) represents a key advantage of nanomedicine compared to traditional medical approaches. This is well represented by radiotherapy in which the dose of ionizing radiation should be calibrated on sensitizers biodistribution. Ideally, this is possible when the drug acts both as radiation enhancer and imaging contrast agent. Here, an easy, one-step, laser-assisted synthetic procedure is used to generate iron-boron (Fe-B) NPs featuring the set of functions required to assist neutron capture therapy (NCT) with magnetic resonance imaging. The Fe-B NPs exceed by three orders of magnitude the payload of boron isotopes contained in clinical sensitizers. The Fe-B NPs have magnetic properties of interest also for magnetophoretic accumulation in tissues and magnetic hyperthermia to assist drug permeation in tissues. Besides, Fe-B NPs are biocompatible and undergo slow degradation in the lysosomal environment that facilitates in vivo clearance through the liver-spleen-kidneys pathway. Overall, the Fe-B NPs represent a new promising tool for future exploitation in magnetic resonance imaging-guided boron NCT at higher levels of efficacy and tolerability.


Assuntos
Nanopartículas , Terapia por Captura de Nêutron , Boro , Ferro , Imageamento por Ressonância Magnética , Distribuição Tecidual
13.
Appl Radiat Isot ; 167: 109353, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33039761

RESUMO

In Boron Neutron Capture Therapy, the boronated drug plays a leading role in delivering a lethal dose to the tumour. The effectiveness depends on the boron macroscopic concentration and on its distribution at sub-cellular level. This work shows a way to colocalize alpha particles and lithium ions tracks with cells. A neutron autoradiography technique is used, which combines images of cells with images of tracks produced in a solid-state nuclear track detector.


Assuntos
Terapia por Captura de Nêutron de Boro/métodos , Radiometria/métodos , Autorradiografia , Linhagem Celular Tumoral , Relação Dose-Resposta à Radiação , Humanos
14.
Appl Radiat Isot ; 165: 109314, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32768928

RESUMO

Preliminary studies for the design of an accelerator-based BNCT clinical facility are presented. The Beam Shaping Assembly neutron activation was evaluated experimentally and with Monte Carlo simulations. The activations of patient, air and walls in the room, the absorbed doses by the patient and the in-air dose distributions were evaluated. Based on these calculations, different walls compositions were tested to optimize the environmental conditions. Borated concrete, advantageously reducing the thermal flux in the room, was proven the best choice.


Assuntos
Berílio/química , Terapia por Captura de Nêutron de Boro/métodos , Aceleradores de Partículas , Humanos , Método de Monte Carlo , Prótons
15.
Appl Radiat Isot ; 163: 109205, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32392166

RESUMO

The cold neutron beam at the PF1b line at the Institut Laue-Langevin (ILL), without fast neutrons and a low contribution of gamma rays, is a very suitable facility to measure cell damage following low-energy neutron irradiation. The biological damage associated with the thermal and the boron doses can be obtained in order to evaluate the relative biological effectiveness (RBE) for Boron Neutron Capture Therapy. Three different experiments were carried out on the A375 melanoma cell line: the first one in a hospital LINAC, to obtain the reference radiation data, and the other two at the ILL, in which the damage to cells with and without boron compounds added was measured.


Assuntos
Compostos de Boro/administração & dosagem , Melanoma/patologia , Terapia por Captura de Nêutron de Boro/métodos , Linhagem Celular Tumoral , Humanos , Nêutrons
16.
Radiat Environ Biophys ; 58(2): 237-245, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30689023

RESUMO

Osteosarcoma is the most common primary malignant tumour of bone in young patients. The survival of these patients has largely been improved due to adjuvant and neo-adjuvant chemotherapy in addition to surgery. Boron neutron capture therapy (BNCT) is proposed as a complementary therapy, due to its ability to inactivate tumour cells that may survive the standard treatment and that may be responsible for recurrences and/or metastases. BNCT is based on neutron irradiation of a tumour enriched in 10B with a boron-loaded drug. Low-energy neutron capture in 10B creates charged particles that impart a high dose to tumour cells, which can be calculated only knowing the boron concentration. Charged particle spectrometry is a method that can be used to quantify boron concentration. This method requires acquisition of the energy spectra of charged particles such as alpha particles produced by neutron capture reactions in thin tissue sections irradiated with low-energy neutrons. Boron concentration is then determined knowing the stopping power of the alpha particles in the sample material. This paper describes the adaptation of this method for bone, with emphasis on sample preparation, experimental set-up and stopping power assessment of the involved alpha particles. The knowledge of boron concentration in healthy bones is important, because it allows for any dose limitation that might be necessary to avoid adverse effects such as bone fragility. The measurement process was studied through Monte Carlo simulations and analytical calculations. Finally, the boron content of bone samples was measured by alpha spectrometry at the TRIGA reactor in Pavia, Italy, and compared to that obtained by neutron autoradiography. The agreement between the results obtained with these techniques confirms the suitability of alpha spectrometry to measure boron in bone.


Assuntos
Boro/análise , Fêmur/química , Adulto , Partículas alfa , Animais , Humanos , Método de Monte Carlo , Ovinos
17.
Chempluschem ; 84(4): 345-351, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-31939222

RESUMO

Boronated molecular systems can be applied to boron neutron capture therapy (BNCT). Among these systems, carborane-containing phthalocyanines (Pcs) are the most promising BNCT agents. Herein we report the new zinc (II) complex of the hexacationic Pc 6, which has been obtained as iodide salt through quaternization of the neutral precursor with methyl iodide. Compound 6 was synthesized over a sequence of four steps. The complex, and its precursors as well, were characterized by a combination of spectroscopic techniques, and their structures assessed by 1 H, 13 C, 11 B, and two-dimensional NMR spectroscopy experiments. Together with a marked tendency to aggregate, 6 showed appreciable solubility in water. Singlet oxygen quantum yield (ΦΔ ) of 0.38, and fluorescence quantum yield (ΦF ) of 0.13 were obtained for 6 in a DMF solution. The complex proved to be very effective in enriching UMR-106 cells with 10 B, showing very good performance even in case of very low concentrations exposure, i. e. 1 ppm, that moreover resulted in a mild cytotoxic effect. Such a feature can be related to the polycationic nature of the complex, and hence to the well-known propensity of positively charged species to enter the cellular membrane or to adhere to its external surface.


Assuntos
Boranos/farmacologia , Terapia por Captura de Nêutron de Boro , Indóis/farmacologia , Animais , Boranos/química , Sobrevivência Celular/efeitos dos fármacos , Relação Dose-Resposta a Droga , Indóis/síntese química , Indóis/química , Isoindóis , Estrutura Molecular , Ratos , Relação Estrutura-Atividade , Células Tumorais Cultivadas , Zinco/química
18.
Appl Radiat Isot ; 137: 62-67, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29587160

RESUMO

The neutron autoradiography technique using polycarbonate nuclear track detectors (NTD) has been extended to quantify the boron concentration in hard tissues, an application of special interest in Boron Neutron Capture Therapy (BNCT). Chemical and mechanical processing methods to prepare thin tissue sections as required by this technique have been explored. Four different decalcification methods governed by slow and fast kinetics were tested in boron-loaded bones. Due to the significant loss of the boron content, this technique was discarded. On the contrary, mechanical manipulation to obtain bone powder and tissue sections of tens of microns thick proved reproducible and suitable, ensuring a proper conservation of the boron content in the samples. A calibration curve that relates the 10B concentration of a bone sample and the track density in a Lexan NTD is presented. Bone powder embedded in boric acid solution with known boron concentrations between 0 and 100 ppm was used as a standard material. The samples, contained in slim Lexan cases, were exposed to a neutron fluence of 1012 cm-2 at the thermal column central facility of the RA-3 reactor (Argentina). The revealed tracks in the NTD were counted with an image processing software. The effect of track overlapping was studied and corresponding corrections were implemented in the presented calibration curve. Stochastic simulations of the track densities produced by the products of the 10B thermal neutron capture reaction for different boron concentrations in bone were performed and compared with the experimental results. The remarkable agreement between the two curves suggested the suitability of the obtained experimental calibration curve. This neutron autoradiography technique was finally applied to determine the boron concentration in pulverized and compact bone samples coming from a sheep experimental model. The obtained results for both type of samples agreed with boron measurements carried out by ICP-OES within experimental uncertainties. The fact that the histological structure of bone sections remains preserved allows for future boron microdistribution analysis.


Assuntos
Autorradiografia/métodos , Boro/análise , Nêutrons , Animais , Autorradiografia/normas , Osso e Ossos/química , Boro/normas , Terapia por Captura de Nêutron de Boro , Calibragem , Simulação por Computador , Modelos Animais , Radiometria/métodos , Radiometria/normas , Ovinos , Processos Estocásticos , Distribuição Tecidual
19.
Radiat Oncol ; 12(1): 130, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28806981

RESUMO

BACKGROUND: Osteosarcoma is the most frequent primary malignant bone tumour, and its incidence is higher in children and adolescents, for whom it represents more than 10% of solid cancers. Despite the introduction of adjuvant and neo-adjuvant chemotherapy that markedly increased the success rate in the treatment, aggressive surgery is still needed and a considerable percentage of patients do not survive due to recurrences or early metastases. Boron Neutron Capture Therapy (BNCT), an experimental radiotherapy, was investigated as a treatment that could allow a less aggressive surgery by killing infiltrated tumour cells in the surrounding healthy tissues. BNCT requires an intense neutron beam to ensure irradiation times of the order of 1 h. In Italy, a Radio Frequency Quadrupole (RFQ) proton accelerator has been designed and constructed for BNCT, and a suitable neutron spectrum was tailored by means of Monte Carlo calculations. This paper explores the feasibility of BNCT to treat osteosarcoma using this neutron source based on accelerator. METHODS: The therapeutic efficacy of BNCT was analysed evaluating the dose distribution obtained in a clinical case of femur osteosarcoma. Mixed field dosimetry was assessed with two different formalisms whose parameters were specifically derived from radiobiological experiments involving in vitro UMR-106 osteosarcoma cell survival assays and boron concentration assessments in an animal model of osteosarcoma. A clinical case of skull osteosarcoma treated with BNCT in Japan was re-evaluated from the point of view of dose calculation and used as a reference for comparison. RESULTS: The results in the case of femur osteosarcoma show that the RFQ beam would ensure a suitable tumour dose painting in a total irradiation time of less than an hour. Comparing the dosimetry between the analysed case and the treated patient in Japan it turns out that doses obtained in the femur tumour are at least as good as the ones delivered in the skull osteosarcoma. The same is concluded when the comparison is carried out taking into account osteosarcoma irradiations with photon radiation therapy. CONCLUSIONS: The possibility to apply BNCT to osteosarcoma would allow a multimodal treatment consisting in neo-adjuvant chemotherapy, high-LET selective radiation treatment and a more conservative surgery.


Assuntos
Neoplasias Ósseas/radioterapia , Terapia por Captura de Nêutron de Boro/métodos , Osteossarcoma/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Adolescente , Animais , Humanos , Masculino , Radiometria , Ratos
20.
Rep Pract Oncol Radiother ; 21(2): 123-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26933395

RESUMO

AIM: Boron Neutron Capture Therapy (BNCT) is a binary hadrontherapy which exploits the neutron capture reaction in boron, together with a selective uptake of boronated substances by the neoplastic tissue. There is increasing evidence that future improvements in clinical BNCT will be triggered by the discovery of new boronated compounds, with higher selectivity for the tumor with respect to clinically used sodium borocaptate (BSH) and boronophenylalanine (BPA). BACKGROUND: Therefore, a (10)B quantification technique for biological samples is needed in order to evaluate the performance of new boronated formulations. MATERIALS AND METHODS: This article describes an improved neutron autoradiography set-up employing radiation sensitive films where the latent tracks are made visible by proper etching conditions. RESULTS: Calibration curves for both liquid and tissue samples were obtained. CONCLUSIONS: The obtained calibration curves were adopted to set-up a mechanism to point out boron concentration in the whole sample.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA